• Title/Summary/Keyword: 316 Stainless Steel

Search Result 458, Processing Time 0.028 seconds

Uncertainty evaluation in electrochemical noise resistance measurement (전기화학적 노이즈 저항 측정에서의 불확도 평가)

  • Kim, Jong Jip;Kang, Su Yeon
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

A study for biocompatibility of acupuncture's metal material - Focused on chemical composition and mechanical character - (침 금속재료에 대한 생체적합성 연구 - 화학적 조성 및 기계적 특성을 중심으로 -)

  • Baek, Yong-hyeon;Chung, In-tae;Lee, Sang-hun;Lee, Jae-dong;Choi, Do-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.159-176
    • /
    • 2004
  • Objective : To present a criteria for acupuncture standardization, which will improve quality of acupuncture and secure safety, through studies of the biocompatibility of acupuncture. Methods : The acupunctures distributed in Korea were studied. The chemical composition, elasticity, and the solidity of the acupuncture's metal material was analyzed. Results & Conclusions : 1) The acupunctures distributed in Korea were all produced with ST304. Because acupuncture is used on a living body, the corrosion resistance, allergy proof and magnetism of the metal material should be considered. In this point, STS316 stainless steel would be more suitable than ST304. 2) The elasticity and solidity of the acupuncture's metal material distributed in Korea meet the medical instrument standards of the Korea Food and Drug Administration. But since the standards are only roughly outlined, the criteria should be realized and standardized.

  • PDF

Creep-Fatigue Crack Growth Behavior of a Structure with Crack Like Defects at the Welds

  • Lee, Hyeong-Yeon;Kim, Seok-Hoon;Lee, Jae-Han;Kim, Byung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2136-2146
    • /
    • 2006
  • A study on a creep-fatigue crack growth behavior has been carried out for a cylindrical structure with weldments by using a structural test and an evaluation according to the assessment procedures. The creep-fatigue crack growth behavior following the creep-fatigue crack initiation has been assessed by using the French A16 procedure and the conservatism for the present structural test has been examined. The structural specimen is a welded cylindrical shell made of 316 L stainless steel (SS) for one half of the cylinder and 304 SS for the other half. In the creep-fatigue test, the hold time under a tensile load which produces the primary nominal stress of 45 MPa was one hour at $600^{\circ}C$ and creep-fatigue loads of 600 cycles were applied. The evaluation results for the creep-fatigue crack propagation were compared with those of the observed images from the structural test. The assessment results for the creep-fatigue crack behavior according to the French Al6 procedure showed that the Al6 is overly conservative for the creep-fatigue crack propagation in the present case with a short hold time of one hour.

A Study on the Erosion Behavior of the Ceramic Sprayed Coating Layer in the Molten 55% Al-Zn (용융 55%Al-Zn 중에서 세라믹 용사 피막의 침식 거동에 관한 연구)

  • 강태영;임병문;최장현;김영식
    • Journal of Welding and Joining
    • /
    • v.18 no.3
    • /
    • pp.51-59
    • /
    • 2000
  • Sink roll has been used in molten 55%Al-Zn alloy bath of continuous galvanizing line for sinking and stabilizing working steel strip in molten metal bath. In the process, the sink roll body inevitably build up dross compounds and pitting on the sink roll surface during 55%Al-Zn alloy coated strip production, and the life time of the sink roll is shorten by build up dross compounds and pitting. The present study examined the application of thermally sprayed ceramic coatings method on sink roll body for improving erosion resistance at molten 55% Al-Zn pool. In this experiment, the stainless steels such as STS 316L and STS 430F were used as the substrate materials. The CoNiCr and WE-Co powder were selected as bond coating materials. Moreover $Al_2O_3-ZrO_2-SiO_2 and ZrO_2-SiO_2$ powders selected as the top coating materials. Appearances of the specimens before and after dipping to molten 55%Al-Zn pool were compared and analyzed. As a result of this study, STS430F of substrate, WC-Co of bond spray coatings, $ZrO_2-SiO_2$ power of top spray coatings is the best quality in erosion resistance test at molten 55%Al-Zn pool

  • PDF

Performance Tests and Development of the Cyclic Load Device Using a Bellows (벨로우즈를 이용한 반복 하중부과장치의 개발 및 성능시험)

  • Choi, Myoung-Hwan;Cho, Man-Soon;Park, Sung-Jae;Kim, Bong-Goo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.9
    • /
    • pp.903-909
    • /
    • 2007
  • A fatigue capsule is one of the special capsules to investigate the fatigue characteristics of the nuclear materials during an irradiation test in a research reactor, HANARO. In this study, the performance test and the preliminary fatigue test results by using a cyclic load device newly developed for a fatigue capsule are described. In order to obtain the characteristics such as a realization and a controllability of the periodic wave shape and the relationship between the pressure and the load, a spring and rigid bar specimens are used. The fatigue test for the 316L stainless steel specimen with 1.8mm in diameter and 12.5mm in gage length is also performed under the same conditions as the temperature($550^{\circ}C$) of the specimen during irradiation tests. As a result of the test, the fracture of the specimen occurs at a total of 70,120 cycles(about 12 days), and the displacement in this case is 2.02 mm. It is expected that these results will be used for determining test conditions and a comparison of the in-pile fatigue test results.

Post-buckling analysis of Timoshenko beams with temperature-dependent physical properties under uniform thermal loading

  • Akbas, Seref Doguscan;Kocaturk, Turgut
    • Structural Engineering and Mechanics
    • /
    • v.44 no.1
    • /
    • pp.109-125
    • /
    • 2012
  • Post-buckling behavior of Timoshenko beams subjected to uniform temperature rising with temperature dependent physical properties are studied in this paper by using the total Lagrangian Timoshenko beam element approximation. The beam is clamped at both ends. In the case of beams with immovable ends, temperature rise causes compressible forces end therefore buckling and post-buckling phenomena occurs. It is known that post-buckling problems are geometrically nonlinear problems. Also, the material properties (Young's modulus, coefficient of thermal expansion, yield stress) are temperature dependent: That is the coefficients of the governing equations are not constant in this study. This situation suggests the physical nonlinearity of the problem. Hence, the considered problem is both geometrically and physically nonlinear. The considered highly non-linear problem is solved considering full geometric non-linearity by using incremental displacement-based finite element method in conjunction with Newton-Raphson iteration method. The beams considered in numerical examples are made of Austenitic Stainless Steel (316). The convergence studies are made. In this study, the difference between temperature dependent and independent physical properties are investigated in detail in post-buckling case. The relationships between deflections, thermal post-buckling configuration, critical buckling temperature, maximum stresses of the beams and temperature rising are illustrated in detail in post-buckling case.

Structural Analysis of 1000A Butterfly Valve Components (1000A용 버터플라이 밸브 주요부품의 구조해석)

  • Kong, Yu-Sik;Kim, Seon-Jin;Jung, Min-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.140-145
    • /
    • 2009
  • This paper deals with a stability evaluation of a butterfly valve using the body and disc of a valve seat. The experimental results of a strength evaluation are shown using STS316 stainless steel and spheroidal graphite cast iron (GCD450). The disc material was made from GCD450. The results of the strength analysis are as follows: Ultimate tensile strength 485MPa, Yield strength 370 MPa, Young's modulus $1.1{\times}10^5$, and Poisson's ratio v = 0.28. For the results of the disc analysis, the safety factor was about 4. This shows that a design was derived that satisfied the requirements of structural safety. However, some problems, such as the deflection and deformation of the disc, may occur when the sea water has back flow with a high pressure.

Development of Small Size Coriolis Mass Flowmeter (소형 코리올리 질량 유량계의 개발)

  • Lim Ki-Won;Ji Jueng-Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.6 s.249
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

고체원소 이온주입 공정으로 제조된 NbN 박막의 내마모 특성 평가

  • Park, Won-Ung;Choe, Jin-Yeong;Jeon, Jun-Hong;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.62-62
    • /
    • 2010
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등에 의한 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공대용물로써 최근 인구의 고령화와 질병, 사고의 증가에 따라 그 수요가 급격히 증가하는 추세를 보이고 있다. 인공관절의 소재로는 현재 metal-on-polymer(MOP) 소재가 가장 많이 사용되고 있는데, metal 소재로서는 Co-Cr계 합금이, polymer 소재로서는 초고분자량 폴리에틸렌 (ultra high molecular weight polyethylene) 이 주로 사용되고 있다. MOP 소재의 경우 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인해 관절이 느슨해지는 문제점이 발생하여 재시술의 주요 원인이 되고 있다. 또한 metal 소재로 주로 사용되고 있는 Co-Cr계 합금의 경우 인공관절의 마모, 부식 현상에 의해 Co, Cr등이 체내에 용출되어 세포독성의 문제를 일으킬 수 있다는 단점을 가지고 있다. 본 연구에서는 고체원소 이온주입 기술을 이용하여 316L stainless steel 기판에 niobium을 이온 주입 한 후 niobium nitride (NbN) 박막을 증착하여 counterpart 소재인 초고분자량 폴리에틸렌(UHMWPE) 의 마모를 줄이는 실험을 진행하였다. Pin-on-disk tribometer를 통해 마모 테스트를 진행하여 NbN 박막의 내마모특성을 평가하였으며, 박막의 결정구조 및 화학적 특성을 평가하기 위해 XRD, AES 분석을 수행하였다. 또한 박막의 경도와 표면조도를 측정하기 위해 micro hardness tester, AFM을 이용하였다.

  • PDF

Electrical Properties and Synthsis of Large Area Conductive Nano Carbon Films by Linear Ion Beam Source

  • Yeo, Gi-Ho;Sin, Ui-Cheol;Yu, Jae-Mu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.220.1-220.1
    • /
    • 2014
  • 본 연구에서는 PECVD 공법 중에 이온화 에너지가 높은 선형이온빔 소스를 이용하여 고온에서 전도성 카본박막을 코팅하였다. 카본 박막 코팅을 위한 Precursor는 $C_2H_2$ gas를 이용하였으며, 온도에 따른 카본 박막의 전기적 특성 및 두께에 따른 카본 박막 성장 구조를 분석하였다. 카본 박막의 전기적 특성은 Interfacial contact resistance (ICR) 방법으로 측정하였으며, 접촉 저항 측정을 위한 모재는 SUS316L stainless steel을 사용하였고 카본 박막 성장 구조 분석을 위해서는 폴리싱된 Si-wafer를 사용하였다. 선형이온빔 소스를 이용하여 상온에서 증착한 카본 코팅의 접촉저항 값은 50 nm 코팅 두께에서 $660m{\Omega}cm^2@10kgf/cm^2$으로 비정질상의 특성을 나타냈으며, 고온에서는 $14.8m{\Omega}cm^2@10kgf/cm^2$으로 온도가 증가함에 따라 비정질상의 카본 박막이 전도성을 가지는 카본박막으로의 성장을 확인할 수 있었다. 또한 전도성 카본 박막의 성장 구조 분석은 FE-SEM 및 Raman spectrum 분석을 통해 확인하였으며, 그 결과 코팅 두께가 증가할수록 카본 입자들은 수nm에서 약 150 nm의 카본 cluster를 형성하며 성장하였다. 이때 전도성 카본 박막의 두께에 따른 접촉저항의 값은 고온 조건에서 카본 박막의 두께가 약 100 nm일 때, $12.1m{\Omega}cm^2@10kgf/cm^2$의 가장 낮은 값을 가졌다. 위의 결과를 경제성이 아주 우수한 대면적 전도성 나노 카본 박막의 상용화 가능성이 높아질 것으로 기대된다.

  • PDF