• 제목/요약/키워드: 3-way stopcock

검색결과 5건 처리시간 0.02초

정맥내 주사요법시 수액세트에 연결된 3 way-stopcock의 오염정도에 관한 실태조사 (Degree of contamination in 3-way stopcock connected to infusion set on the intravenous therapy)

  • 홍해숙;김윤경;나연경;이경란;곽경숙
    • Journal of Korean Biological Nursing Science
    • /
    • 제4권2호
    • /
    • pp.113-125
    • /
    • 2002
  • This study is to evaluate contamination of the 3-way stopcocks connected to infusion set, which is used to the patients admitted to emergency room in a general hospital in D city. The data were collected from Oct. 1, 2001 to Feb. 25, 2002. First of all, in order to select microorganisms, From the 50 patients were randomized, Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus, Pseudomonas aeruginosa, Acinetobacter detected. Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus were determined to be evaluated in this study. As a result, 8 of the patients were Coagulase Negative Staphylococcus positive(>15 colonies), 4 were Staphylococcus aureus positive(>15 colonies). 1 was micrococcus positive(>15 colonies). Among the patients who were Coagulase Negative Staphylococcus positive 112(average) colonies were detected on the first day, 429 were on the second day, and 563 were on the third day. In case of patients of Staphylococcus aureus positive, 85(average) colonies were detected on the first day, 151 were on the second day, and the 203 were on the third day. CNS was cultured using API kit for the 8 patients who were in CNS positive. One case was detected Staphylococcus capitis, another one case was Staphylococcus chromogenes. Two cases were Staphylococcus xylosus, another two were Staphylococcus hominis, and the remainer were Staphylococcus epidermidis. As a result, the API codes of two Staphylococcus epidermidis had shown the same pattern, and the resistance patterns of the them were the same, too. As a result of resistance test among 5 patients who have shown that the same resistance pattern in 02SAK1, 02SAK5, 02SAK2, 02SAK4. As a result of this study, aseptic technique of 3-way stopcock intravenous therapy can protect infections, and it is needed the sterilization of the 3-way stopcock just before injection using disinfectants. It needs to improve the 3 way stopcock change intervals from 48 hours.

  • PDF

소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구 (Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants)

  • 박정균;차재훈;김광현;안종기;홍다영;성효진
    • 핵의학기술
    • /
    • 제20권2호
    • /
    • pp.27-31
    • /
    • 2016
  • DMSA 방사성의약품은 몸쪽 세뇨관과 주위 콩팥겉질 세포에 섭취되어 콩팥 겉질의 평가 및 영상화에 유용하게 사용되는 의약품으로 신우신염의 진단에 매우 예민도가 높은 검사여서 소아에게 많이 사용되고 있는 검사이다. 소아에게 투여되는 방사성 동위원소의 양은 미량이 되고 소아의 신체가 Field of View (FOV)에 대부분이 포함이 되는 만큼 방광에 소변이 차있게 된다면 그만큼 콩팥을 영상화하는데 영향을 미치게 됨을 연구를 통해 확인하고자 하였다. 본 연구에서는 총 계수 설정법과 시간 설정법 중에 시간 설정법으로 연구를 진행하였다. 2015년 10월에서 12월까지 요로감염 및 신우신염이 의심되어 본원을 내원 및 입원하여 시행한 생후 1개월부터 12개월까지의 소아 34명을 대상으로 하였으며 환자에게는 동일한 선량 18.5 MBq (0.5 mCi)를 각각의 환자에게 동일한 양을 주입 후 2~3시간 후 검사를 진행하였다. 이때 사용된 장비는 Siemens사의 Symiba E (Siemens Medical solution USA, Inc.) 장비를 사용하였고 영상의 분석하기 위하여 Syngo MI Applications VA60C 소프트웨어를 사용하였다. 통계학적 분석은 IBM SPSS Statistics Ver. 21를 이용하여 분석하였으며 Paired t-test를 이용하여 비교 분석하였다. 검사는 한번의 검사에 7분의 시간으로 후면상을 획득하였으며 이후 자체 제작된 납을 이용하여 방광을 가린 후 추가로 동일한 시간으로 영상을 획득하였다. 영상 분석 시에 동일한 크기의 (가로 55.2 mm ${\times}$ 세로 70.0 mm)의 ROI (Region of Interest)를 설정하여 분석하였다. 콩팥의 계수는 (Lt. Kidney counts + Rt. Kidney counts) / Total counts의 백분율로 나타내어 계산하여 평가하였고. Background 수치는 같은 영상을 비교하기에 배제하고 연구를 진행하였다. 방광을 차폐시킨 후의 콩팥 계수는 $79.40{\pm}5.19%$ 방광을 차폐시키기 전의 콩팥 계수는 $70.87{\pm}3.18%$으로 나타났으며 (차폐시킨 후 - 차폐 전)의 콩팥 계수는 $8.52{\pm}3.29%$로 차폐시킨 후와 차폐시키기 전을 비교 분석하였을 때 유의한 것으로 나타났다. 주사 방법 중 3way stopcock를 이용하여 주사하였을 경우 차폐 후 콩팥 계수는 $78.10{\pm}4.61%$ 차폐 전 콩팥계수는 $68.92{\pm}2.80%$로 (차폐시킨 후 - 차폐 전)의 콩팥 계수는 $9.18{\pm}3.53%$로 나타났으며 Heparin cap을 이용하였을 경우 차폐 후 $79.84{\pm}3.26%$, 차폐 전 $71.33{\pm}5.14%$로 (차폐시킨 후 - 차폐 전)의 콩팥 계수는 $8.51{\pm}2.92%$로 나타났으며 마지막으로 직접 주사했을 경우 차폐 후 콩팥 계수는 $82.07{\pm}2.35%$, 차폐 전 콩팥 계수는 $75.11{\pm}4.30%$로 (차폐시킨 후 - 차폐 전)의 콩팥 계수는 $6.96{\pm}2.78%$로 세 가지 방법 모두 차폐시킨 후와 차폐시키기 전을 비교 분석하였을 때 유의한 것으로 나타났다. 그리고 직접 주사, Heparin cap, 3way stopcock 순의 콩팥 계수율을 보임을 확인 할 수 있었다. 소아의 Renal DMSA scan검사 시에 방광의 방사능을 제거하여 방광을 차폐하였을 때 차폐하지 않았을 때보다 개선된 콩팥섭취율을 보였고 소아의 경우에 혈관 확보에 어려움이 있지만 직접 주입하거나 환자의 몸에 근접하도록 방사성 동위원소를 주입한다면 더 나은 영상 획득에 도움이 될 것이다.

  • PDF

부분최소자승법을 이용한 혈압 측정에 관한 연구 (A Study on Measurement of Blood Pressure by Partial Least Square Method)

  • 김용주;남은혜;최창현;김종덕
    • Journal of Biosystems Engineering
    • /
    • 제33권6호
    • /
    • pp.438-445
    • /
    • 2008
  • The purpose of this study was to develop a measurement model based on PLS (Partial least square) method for blood pressures. Measurement system for blood pressure signals consisted of pressure sensor, va interface and embedded module. A mercury sphygmomanometer was connected with the measurement system through 3-way stopcock and used as reference of blood pressures. The blood pressure signals of 20 subjects were measured and tests were repeated 5 times per each subject. Total of 100 data were divided into a calibration set and a prediction set. The PLS models were developed to determine the systolic and the diastolic blood pressures. The PLS models were evaluated by the standard methods of the British Hypertension Society (BHS) protocol and the American Association for the Advancement of Medical Instrumentation (AAMI). The results of the PLS models were compared with those of MAA (maximum amplitude algorithm). The measured blood pressures with PLS method were highly correlated to those with a mercury sphygmomanometer in the systolic ($R^2=0.85$) and the diastolic blood pressure ($R^2=0.84$). The results showed that the PLS models were the effective tools for blood pressure measurements with high accuracy, and satisfied the standards of the BHS protocol and the AAMI.

New economical and simple device for intraoperative expansion on small and medium sized soft tissue defects

  • Lee, Jun Won;Park, Seong Hoon;Lee, Seong Joo;Kim, Seong Hwan;Jeong, Hii Sun;Suh, In Suck
    • 대한두개안면성형외과학회지
    • /
    • 제19권3호
    • /
    • pp.235-239
    • /
    • 2018
  • Intraoperative expansion has been used to cover small to large defects without disadvantages of the conventional tissue expanders. Various materials, for example, expanders and Foley catheters are being used. We introduce a new, convenient and economical device immediately available in the operating room, according to the defect size for intraoperative expansion, with latex gloves or balloons. The retrospective study was done with 20 patients who presented with skin and soft tissue defects. During the operation, expansion was done with latex gloves or balloons inflated with saline through an intravenous line and a three-way stopcock. After the inflation, the glove was removed and skin was covered with expanded tissue. A careful decision was made regarding the inflation volume and placement of the expander according to the defect size. There were no postoperative complications. The skin contracture and tension was minimal with a texture similar to the adjacent tissue. The new intraoperative expansion devices with latex gloves and balloons were cheap and made easily right in the operation room. The reconstruction of small to large sized skin defects can be done successfully, functionally and aesthetically without using expensive commercial materials.

방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단 (An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical)

  • 지용기;김동일;김시활;원문희;최성욱;최춘기;석재동
    • 핵의학기술
    • /
    • 제16권2호
    • /
    • pp.126-130
    • /
    • 2012
  • 방사성의약품 제조 시 휘발성 기체의 경우에 완전 차폐가 되지 않고, Hot cell 외부로 그리고 배기덕트를 통해 작업자에게 외부피폭은 물론 호흡을 통해 내부피폭을 가져오게 한다. 처음에는 Hot cell 자체의 배출구를 막아서 방사성기체를 차단하려하였으나 장치에 맞는 기체 밀폐형 댐퍼의 제작이 어렵고, 크기가 맞지 않아서 설치 후에 여전히 문제점이 개선되지 않았다. 그러나 Tedlar gas sampling bag의 사용으로 합성 장치의 가스 배출구를 연결하여 방사성 기체를 저장하고 10반감기가 지난 후에 배출함으로써 작업자의 피폭을 확연히 줄이게 되었으며 $^{18}F$ 방사성 기체는 Hot cell 배출구에 활성탄 필터를 연결하고 최종 배출구에 2차 활성탄 필터를 사용함으로써 배출되는 방사능 농도를 90% 이상 줄여주었다. 단 반감기의 핵종인 경우는 위와 같은 경우를 이용하여 다음날 작업을 할 수 있지만 반감기가 긴 핵종들 같은 경우는 다음날 처리 할 수 없는 문제점들이 발생한다. Decay tank의 추가적인 문제점들을 보완하거나 기체상의 여러 방사성 입자들을 포집 할 수 있는 물질들이 만들어져야 할 것이다. 현재 우리나라는 최종 배출 공기 중 방사능 농도만을 규제하고 있으나 유럽 같은 경우 일일 배출 양과 연간 배출도 규제를 하고 있다. 방사성의약품 합성 시 발생하는 많은 방사성 물질들을 보다 효과적으로 친환경적으로 처리할 수 있는 여러 연구들이 이루어져야 할 것이다.

  • PDF