Degree of contamination in 3-way stopcock connected to infusion set on the intravenous therapy (정맥내 주사요법시 수액세트에 연결된 3 way-stopcock의 오염정도에 관한 실태조사)

  • Hong, Hae-Sook;Kim, Yun-Kyung;Na, Yeon-Kyung;Lee, Gyeung-Ran;Kwak, Kyung-Suk
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.2
    • /
    • pp.113-125
    • /
    • 2002
  • This study is to evaluate contamination of the 3-way stopcocks connected to infusion set, which is used to the patients admitted to emergency room in a general hospital in D city. The data were collected from Oct. 1, 2001 to Feb. 25, 2002. First of all, in order to select microorganisms, From the 50 patients were randomized, Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus, Pseudomonas aeruginosa, Acinetobacter detected. Coagulase Negative Staphylococcus, Staphylococcus aureus, micrococcus were determined to be evaluated in this study. As a result, 8 of the patients were Coagulase Negative Staphylococcus positive(>15 colonies), 4 were Staphylococcus aureus positive(>15 colonies). 1 was micrococcus positive(>15 colonies). Among the patients who were Coagulase Negative Staphylococcus positive 112(average) colonies were detected on the first day, 429 were on the second day, and 563 were on the third day. In case of patients of Staphylococcus aureus positive, 85(average) colonies were detected on the first day, 151 were on the second day, and the 203 were on the third day. CNS was cultured using API kit for the 8 patients who were in CNS positive. One case was detected Staphylococcus capitis, another one case was Staphylococcus chromogenes. Two cases were Staphylococcus xylosus, another two were Staphylococcus hominis, and the remainer were Staphylococcus epidermidis. As a result, the API codes of two Staphylococcus epidermidis had shown the same pattern, and the resistance patterns of the them were the same, too. As a result of resistance test among 5 patients who have shown that the same resistance pattern in 02SAK1, 02SAK5, 02SAK2, 02SAK4. As a result of this study, aseptic technique of 3-way stopcock intravenous therapy can protect infections, and it is needed the sterilization of the 3-way stopcock just before injection using disinfectants. It needs to improve the 3 way stopcock change intervals from 48 hours.

  • PDF

Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in 99mTc-DMSA Renal Scan for Infants (소아 99mTc-DMSA renal scan에서 방광차폐유무와 방사성동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구)

  • Park, Jeong Kyun;Cha, Jae Hoon;Kim, Kwang Hyun;An, Jong Ki;Hong, Da Young;Seong, Hyo Jin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.27-31
    • /
    • 2016
  • Purpose $^{99m}Tc-DMSA$ renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a $^{99m}Tc-DMSA$ renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of $70.9{\pm}3.18%$ while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of $79.4{\pm}5.19%$, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of $68.9{\pm}2.80%$ prior to the shielding and a deviation of $78.1{\pm}5.14%$ after the shielding were displayed. In the method of using a Heparin cap, a deviation of $71.3{\pm}5.14%$ prior to the shielding and a deviation of $79.8{\pm}3.26%$ after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of $75.1{\pm}4.30%$ prior to the shielding and a deviation of $82.1{\pm}2.35%$ after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

  • PDF

A Study on Measurement of Blood Pressure by Partial Least Square Method (부분최소자승법을 이용한 혈압 측정에 관한 연구)

  • Kim, Yong-Joo;Nam, Eun-Hye;Choi, Chang-Hyun;Kim, Jong-Deok
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.438-445
    • /
    • 2008
  • The purpose of this study was to develop a measurement model based on PLS (Partial least square) method for blood pressures. Measurement system for blood pressure signals consisted of pressure sensor, va interface and embedded module. A mercury sphygmomanometer was connected with the measurement system through 3-way stopcock and used as reference of blood pressures. The blood pressure signals of 20 subjects were measured and tests were repeated 5 times per each subject. Total of 100 data were divided into a calibration set and a prediction set. The PLS models were developed to determine the systolic and the diastolic blood pressures. The PLS models were evaluated by the standard methods of the British Hypertension Society (BHS) protocol and the American Association for the Advancement of Medical Instrumentation (AAMI). The results of the PLS models were compared with those of MAA (maximum amplitude algorithm). The measured blood pressures with PLS method were highly correlated to those with a mercury sphygmomanometer in the systolic ($R^2=0.85$) and the diastolic blood pressure ($R^2=0.84$). The results showed that the PLS models were the effective tools for blood pressure measurements with high accuracy, and satisfied the standards of the BHS protocol and the AAMI.

New economical and simple device for intraoperative expansion on small and medium sized soft tissue defects

  • Lee, Jun Won;Park, Seong Hoon;Lee, Seong Joo;Kim, Seong Hwan;Jeong, Hii Sun;Suh, In Suck
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.235-239
    • /
    • 2018
  • Intraoperative expansion has been used to cover small to large defects without disadvantages of the conventional tissue expanders. Various materials, for example, expanders and Foley catheters are being used. We introduce a new, convenient and economical device immediately available in the operating room, according to the defect size for intraoperative expansion, with latex gloves or balloons. The retrospective study was done with 20 patients who presented with skin and soft tissue defects. During the operation, expansion was done with latex gloves or balloons inflated with saline through an intravenous line and a three-way stopcock. After the inflation, the glove was removed and skin was covered with expanded tissue. A careful decision was made regarding the inflation volume and placement of the expander according to the defect size. There were no postoperative complications. The skin contracture and tension was minimal with a texture similar to the adjacent tissue. The new intraoperative expansion devices with latex gloves and balloons were cheap and made easily right in the operation room. The reconstruction of small to large sized skin defects can be done successfully, functionally and aesthetically without using expensive commercial materials.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF