• Title/Summary/Keyword: 3-dimensional analysis method

Search Result 2,741, Processing Time 0.029 seconds

Analysis of golf swing motion for specific properties of club shaft (클럽 샤프트(Club Shaft) 특성에 따른 골프 스윙(Golf Swing)동작 분석)

  • Kim, Sung-Il;Kim, Ky-Hyoung;Kim, Hyung-Soo;Lee, Hyun-Seob;Kim, Jin-Uk;Ahn, Chan-Gyu;Kim, Hee-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.17-32
    • /
    • 2002
  • The purpose of this study was to find the rational method to analyze golf swing with specific property of club shaft. Three subjects were filmed by two high speed digital cameras with 500 fps. The phase analyzed was downswing of each subject. The three-dimensional coordinates of the anatomical landmarks were obtained with motion analysis system Kwon3d 3.0 version and smoothed by lowpass digital filter with cutoff frequency 6Hz. From these data, kinematic and kinetic variables were calculated using Matlab(ver 5.0) The variables for this study were angular velocity and accelerations, which were calculated and following conclusions have been made : 1) Golf swing time of stiff club is faster than that of regular club. 2) In shoulder joint motion of swing with the stiff club, x-stiff showed mort rapid negative acceleration than that of regular club. 3) In regular club, the velocity of club head would be more effective velocity, which was increasing, than those of other clubs before impact. 4) In wrist joint motion of swing with stiff club, x-stiff club showed faster than regular club in the downswing and impact more rapid negative acceleration.

The Effect of Exercise Intensity on Muscle Activity and Kinematic Variables of the Lower Extremity during Squat

  • Jung, Jae-Hu;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.197-203
    • /
    • 2017
  • Objective: The purpose of this study was to determine how exercise intensity affects muscle activity and kinematic variables during squat. Method: Fifteen trainers with >5 years of experience were recruited. For the electromyography (EMG) measurements, four surface electrodes were attached to both sides of the lower extremity to monitor the rectus femoris (RF) and biceps femoris. Three digital camcorders were used to obtain three-dimensional kinematics of the body. Each subject performed a squat in different conditions (40% one-repetition maximum [40%1RM], 60%1RM, and 80%1RM). For each trial being analyzed, three critical instants and two phases were identified from the video recording. For each dependent variable, one-way analysis of variance with repeated measures was used to determine whether there were significant differences among the three different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: The results showed that the average integrated EMG values of the RF were significantly greater in 80%1RM than in 40%1RM during the extension phase. The temporal parameter was significantly longer in 80%1RM than in 40%1RM and 60%1RM during the extension phase. The joint angle of the knee was significantly greater in 80%1RM than in 40%1RM at flexion. The range of motion of the knee was significantly less in 80%1RM than in 40%1RM and 60%1RM during the flexion phase and the extension phase. The angular velocity was significantly less in 80%1RM than in 40%1RM and 60%1RM during the extension phase. Conclusion: Generally, the increase of muscle strength decreases the pace of motion based on the relation between the strength and speed of muscle. In this study, we also found that the increase of exercise intensity may contribute to the increase of the muscle activity of the RF and the running time in the extension phase during squat motion. We observed that increased exercise intensity may hinder the regulation of the range of motion and joint angle. It is suitable to perform consistent movements while controlling the proper range of motion to maximize the benefit of resistance training.

Noninvasive Evaluation of Coronary Artery Bypass Graft Patency by Electron Beam Tomography (전자선 단층 촬영을 이용한 관상동맥 우회로 개존의 비침습적 평가)

  • 최규옥;김호석;조범구
    • Journal of Chest Surgery
    • /
    • v.32 no.8
    • /
    • pp.693-701
    • /
    • 1999
  • Recently non-invasive diagnostic imaging replaced the invasive catheter angiography in the diagnosis of vascular disease. Catheter methods are now almost confined to the purpose of intervention. Coronary artery or coronary artery bypass graft still needs catheter technique because of small diameter and the cardiac motion. The last challenge for radiologists in this domain is to obtain a non-invasive imaging. Electron beam tomography(EBT) for high temporal resolution is able to obtain a coronary arteriogram or coronary artery bypass graft (CABG), of which CABG imaging is quite useful for the evaluation of patency. In our experience as well as others, the accuracy of EBT angiogram in evaluating CABG patency revealed that the accuracy of patency of saphenous vein grafts(SVG) is high due to relatively wide lumen, short and straight course and less influence from cardiac motion. The sensitivity and specificity of patency of SVGs were 92%, 97% respectively in the prospective evaluat on and 100% each in the retrospective evaluation. A false positive and a false negative case are rudimentary errors in the initial learing period. In contrast the analysis of left internal mammary artery(LIMA) graft was difficult due to the inherent small size and the adjacent surgical clips provoking beam-hardening artifact; therefore, the method of combining 3 dimensional reconstruction and flow mode study was important in improving the accuracy of LIMA patency. The sensitivity and specificity of LIMA patency were 100% and 80% in both prospective and retrospective evaluation. Therefore, EBT angiography is an accurate non-invasive diagnostic modality for evaluating the patency of CABG, particularly in SVGs. The accuracy can be improved with the improvement of the EBT and the development of the image reconstruction software.

  • PDF

An Analysis on Response Characteristics of a Dual Neutron Logging using Monte Carlo Simulation (Monte Carlo 모델링을 이용한 이중 중성자검층 반응 특성 분석)

  • Won, Byeongho;Hwang, Seho;Shin, Jehyun
    • The Journal of Engineering Geology
    • /
    • v.27 no.4
    • /
    • pp.429-438
    • /
    • 2017
  • Monte Carlo N-Particle (MCNP) modeling algorithm based on the Monte Carlo method was used to perform the simulation of neutron logging in order to increase the reliability and utilization of neutron logs applied in geological and resource engineering fields. To perform the simulation using MCNP, we used a realistic three-dimensional configuration of neutron sonde and formation. Validation of the modeling was confirmed by comparing the calibration curves of sonde manufacture with those calculated by MCNP modeling. After the validation, lithology effects, pore fluid effects, borehole diameter change, casing effect, and effects of borehole water level were investigated through modeling experiments. Numerical tests indicate that changes in neutron count ratio according to the lithology were quantitatively understood. In case of a borehole with a diameter of 3 inches, ratio of counting rates was higher than expected to be interpreted as borehole fluid has small effects on neutron logging. Effect of casing was also small in general, particular when porosity increases. Since modeling results above the groundwater level showed a tendency opposite to those below the groundwater level, neutron logs can be used to detect groundwater level. The modeling results simulated in this study for various borehole environments are expected to be used for data processing and interpretation of neutron log.

A FINITE ELEMENT ANALYSIS OF THE STRESS DISTRIBUTION AND DISPLACEMENT OF an in-vitro HUMAN MANDIBLE TO THE ORTHOPEDIC FORCE (정형력(整形力)에 대(對)한 하악골내(下顎骨?)의 응력분산(應力分散)과 변위(變位)에 관(關)한 유한요소법적(有限要素法的) 분석(分析))

  • Choue, Ho Koo
    • The korean journal of orthodontics
    • /
    • v.14 no.1
    • /
    • pp.75-92
    • /
    • 1984
  • This study attempted to analyze the distribution of stress, to examine the bending effect in the mandible according to the pulling directions and determine on which pulling directions are adequate when an orthopedic force was applied to the mandible. An orthopedic force, 500gm, was applied to the gnathion, one point of the chin area, in three directions. The three directions were ; high puli' from gnathion to the center of condyle head, and vertical pull, from gnathion to a parallel line with the posterior border of the ramus, and medium pull, from the gnathion to a parallel line with the lower border of mandible. The distribution of principal stress, bending moment and amount of displacement within the mandible was analyzed by a 3-dimensional finite element method and that of the various portions of mandible were computed and compared according to the pulling directions. The results were as follows : 1. The bending moment of each part of a mandible has been found to be markedly larger in case of vertical pull than in case of either high pull or medium pull. In vertical pull the bending moment turned out to largest at the condyle head and neck portion, the gonial angle portion, the coronoid portion and the ascending ramus portion, respectively, while comparatively large at the cuspid and bicuspid portion and the first molar portion. In case of high pull it was largest at the gonial angle portion and becoming smaller at the coronoid portion, the ascending ramus portion, the condyle head and neck portion, and the cuspid and bicuspid portion, in that order. In case of medium pull, however, the bending moment was largest at the condyle head and neck portion, becoming smaller at the first molar portion, the ascending ramus portion, the coronoid portion, the cuspid and bicuspid portion, and gonial angle portion, in that order. 2. As for the bending effect it was calculated to be mostly oriented downward at the mandibular body and backward at the mandibular ramus in both high pull and vertical pull. In case of medium pull it was oriented upward at the mandibular body and forward at the mandibular ramus. 3. The bending effect also turned out to be mostly oriented outward in case of high pull and medium pull, and inward in vertical pull. 4. At the mandibular body and ramus, the bending effect in the upward-downward direction and that in the forward-backward direction were found to be larger than in the inward-outward direction. 5. If and when we expect any correcting effect on the mandibular protrusion by means of the chin cup appliance, we can say sure as conclusion that high pull and vertical pull are more effective than medium pull.

  • PDF

A Study of Issues Related to Self-Directed Learning Screening(SDLS) in Science Specialized High School (과학고 자기주도학습전형 쟁점 연구)

  • Jung, Youn-Hong;Choe, Ho-Seong
    • Journal of The Korean Association For Science Education
    • /
    • v.35 no.3
    • /
    • pp.343-352
    • /
    • 2015
  • This study is to discover the diverse issues related to Self-Directed Learning Screening (SDLS) and draw implications by analyzing its critical points. Using content analysis and interviews with admission officers, tentative issues were finalized and reviewed by researchers and educators. A Survey was developed based on the 96 issues after having evidence of content validity using the Delphi method. To conduct survey, e-mails were sent to admissions officers in twenty science specialized high schools. They were asked to response to questions about perceptions of critical issues and if there are any issues in their schools. Using mean scores of two factors based on its critical issues and frequencies, a two-dimensional classification table for each type was presented. Four critical issues for each type were discovered. The first type indicates minor issues that include 28 items that were less than the overall mean scores in terms of critical issues and its frequencies. The second type indicates tentative issues that include 29 items that were greater than the mean score in critical issues but less in its frequencies. The third type indicates general issues that include 17 items that were less than the mean score in critical issues but greater in its frequencies. The last type indicates critical issues that include 22 items that were greater than the mean scores in two factors. The discovered results of critical issues and its types in this study can be considered a core part of the screening process in schools, especially, critical issues should play an important role in the process of admission screening planning.

Postoperative Left Ventricular Dynsfunction in Adult PDA (성인 동맥관 개존증 수술 후 좌심실 기능 저하의 위험 인자 분석)

  • 윤태진
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.785-791
    • /
    • 2000
  • Left ventricular dysfuction is common in immediate postoperative periods after surgical correction of heart diseases with chronic left ventricular volume overload. We speculated postoperative changes of left ventricular volume and unction in patients with patent ductus osus(PDA) who had underwent surgical repair at ages older than 16 years. Factors influencing postoperative left ventricular volume and function were also analyzed. Material and Method: From August 1989 to August 1999 thirty-siz adult patients with PDA 28 females and 8 males. were enrolled in this study. Their age ranged from 16 years to 57 years(mean :32 years). Types of surgical repair were division with primary closure in 22, division with patch closure in 6, internal obliteration using cardiopulmonary bypass in 4 and ligation in 4. Aortic clamping was combined during surgical repair in 22(61%) and cardiopulmonary bypass was used in 8(22%) Two-dimensional echocardiography studies were performed in 34(94%) preoperatively and in 25(66%) immediate postoperatively to assess postoperative changes of left ventricular internal dimensions. left ventricular volume and ejection fraction. Duration of postoperative follow-up ranged from 1 month to 99 months (mean:22 months) and 10 patients underwent 16 echocardiographic evaluation during this period Result : Preoperative and postoperative left ventricular systolic dimensions(LVIDs) were 42$\pm$8.0mm and 42$\pm$8.3mm left ventricular diastolic dimensions(LVIDd) were 64$\pm$10.0mm and 56$\pm$7.4mm left ventricular end systolic volumes(LVESV) were 62$\pm$19cc (z=1.87$\pm$0.06) and 59$\pm$24cc(z=1.78$\pm$0.08) left ventricular end diastolic volumes(LVEDL) were 169$\pm$40cc(z-1.17$\pm$0.1) and 112$\pm$29cc(z=0.85$\pm$0.1) and ejection fractions(EF) were 66$\pm$6.7% and 48$\pm$12.6% respectively. There were statistically significant differences between preoperative and postoperative values in LVDIDd(p=0.001) LVEDV(p=0.001) and EF(p=0.0001) while no significant difference is LVIDs and LVESV. Postoperative depression of ejcection fraction was significantly related with z-score of preoperative LVESV and LVEDV by univariateanalysis while LVEDV only was significant risk factor for postoperative LV dysfunction by multiple regressioin analysis ($\Delta$LVEF=-13.3-4.62$\times$LVEDV(z), p=0.001) During the follow-up periods ejection fractions become normalized in all except one patients. Conclusion ; Left ventricular function is usually deteriorated after the surgical correction of PDA in adult age and preoperative LVEDV is a major determinant of postoperative LV function.

  • PDF

Numerical Study for Flow Uniformity in Selective Catalytic Reduction(SCR) Process (SCR 공정에서 반응기 내부의 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4666-4672
    • /
    • 2011
  • Performance of NOx removal in SCR(Selective Catalytic Reduction) process depends on such various factors as catalyst factors (catalyst composition, catalyst form, space velocity, etc.), temperature of exhaust gas, and velocity distribution of exhaust gas. Especially the flow uniformity of gas stream flowing into the catalyst layer is believed to be the most important factor to influence the performance. In this research, the flow characteristics of a SCR process at design stage was simulated, using 3-dimensional numerical analysis method, to confirm the uniformity of the gas stream. In addition, the effects of guide vanes, baffles, and perforated plates on the flow uniformity for the inside and catalyst layer of the reactor were studied in order to optimize the flow uniformity inside the SCR reactor. It was found that the installation of a guide vane at the inlet duct L-tube part and the installation of a baffle at the upper part is very effective in avoiding chaneling inside the reactor. It was also found that additional installation of a perforated plate at the lower part of the potential catalyst layer buffers once more the flow for very uniform distribution of the gas stream.

Geostatistical Approach to Integrated Modeling of Iron Mine for Evaluation of Ore Body (철광산의 광체 평가를 위한 지구통계학적 복합 모델링)

  • Ahn, Taegyu;Oh, Seokhoon;Kim, Kiyeon;Suh, Baeksoo
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.177-189
    • /
    • 2012
  • Evaluation of three-dimensional ore body modeling has been performed by applying the geostatistical integration technique to multiple geophysical (electrical resistivity, MT) and geological (borehole data, physical properties of core) information. It was available to analyze the resistivity range in borehole and other area through multiple geophysical data. A correlation between resistivity and density from physical properties test of core was also analyzed. In the case study results, the resistivity value of ore body is decreased contrast to increase of the density, which seems to be related to a reason that the ore body (magnetite) includes heavy conductive component (Fe) in itself. Based on the lab test of physical properties in iron mine region, various geophysical, geological and borehole data were used to provide ore body modeling, that is electrical resistivity, MT, physical properties data, borehole data and grade data obtained from borehole data. Of the various geostatistical techniques for the integrated data analysis, in this study, the SGS (sequential Gaussian simulation) method was applied to describe the varying non-homogeneity depending on region through the realization that maintains the mean and variance. With the geostatistical simulation results of geophysical, geological and grade data, the location of residual ore body and ore body which is previously reported was confirmed. In addition, another highly probable region of iron ore bodies was estimated deeper depth in study area through integrated modeling.

Thermal Energy Balance Analysis of a Packed Bed for Rock Cavern Thermal Energy Storage (충전층을 이용한 암반공동 열에너지저장시스템의 열에너지 수지 분석)

  • Park, Jung-Wook;Ryu, Dongwoo;Park, Dohyun;Choi, Byung-Hee;Synn, Joong-Ho;Sunwoo, Choon
    • Tunnel and Underground Space
    • /
    • v.23 no.3
    • /
    • pp.241-259
    • /
    • 2013
  • A packed bed thermal energy storage (TES) consisting of solid storage medium of rock or concrete through which the heat transfer fluid is circulated is considered as an attractive alternative for high temperature sensible heat storage, because of the economical viability and chemical stability of storage medium and the simplicity of operation. This study introduces the technologies of packed bed thermal energy storage, and presents a numerical model to analyze the thermal energy balance and the performance efficiency of the storage system. In this model, one dimensional transient heat transfer problem in the storage tank is solved using finite difference method, and temperature distribution in a storage tank and thermal energy loss from the tank wall can be calculated during the repeated thermal charging and discharging modes. In this study, a high temperature thermal energy storage connected with AA-CAES (advanced adiabatic compressed air energy storage) was modeled and analyzed for the temperature and the energy balance in the storage tank. Rock cavern type TES and above-ground type TES were both simulated and their results were compared in terms of the discharging efficiency and heat loss ratio.