• Title/Summary/Keyword: 3-axis

Search Result 4,819, Processing Time 0.03 seconds

Design of a Novel Polishing Tool Mechanism with 3-axis Compliance

  • Gi-Seong Kim;Han Sung Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_1
    • /
    • pp.993-999
    • /
    • 2023
  • In this paper, a novel polishing tool mechanism with 3-axis compliance is presented, which consists of 2-axis rotational and 1-axis linear compliances in series. The 2-axis rotational compliance mechanism is made up of four cantilever beams for adjusting rotational stiffness and one flexure universal joint at the center for constraining the z-axis deflection. The 2-axis rotational compliance can mechanically adjust the polishing tool to machined surfaces. The polishing press force can be simply controlled by using a linear spring along the z-axis. The 2-axis rotational and 1-axis linear compliance design is decoupled. The stiffness analysis of the 2-axis compliance mechanism was performed based on link compliance matrix and rigid body transformation. A 3-axis polishing tool was designed by configuring the 2-axis compliance mechanism and one linear spring.

Development of the Intelligent Gripper Using Two 3-axis Force Sensor (3 축 힘센서를 이용한 지능형 그리퍼 개발)

  • Kim, Gab-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.3 s.192
    • /
    • pp.47-54
    • /
    • 2007
  • This paper describes the development of the intelligent gripper with two 3-axis force sensor that can measure forces Fx, Fy, Fz simultaneously, for stably grasping an unknown object. In order to grasp an unknown object using an intelligent gripper softly, it should measure the force in the gripping direction and the force in the gravity direction, and perform the force control using the measured farces. Thus, the intelligent gripper should be composed of 3-axis force sensor that can measure forces Fx, Fy, Fz at the same time. In this paper, the intelligent gripper with two 3-axis force sensor was manufactured and its characteristic test was carried out. The fabricated gripper could grasp an unknown object stably. Also, the sensing element of 3-axis force sensor was modeled and designed with five parallel-plate beams, and 3-axis force sensor for the intelligent gripper was fabricated. The characteristic test of the made sensor was carried out.

Development of 3-axis finger force sensor for an intelligent robot's hand (로봇의 지능형 손을 위한 3축 손가락 힘센서 개발)

  • Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.411-416
    • /
    • 2006
  • This paper describes the development of a 3-axis finger force sensor to grasp an unknown object safely in an intelligent robot's hand. In order to safely grasp an unknown object, robot's hand should measure the weight of an object and the force of grasping direction simultaneous. But, in the published papers, the grippers and hands equippd with the force sensor that could only measure the force of grasping direction, and grasped objects using their sensors. These grippers and hands can't safely grasp unknown objects, because they can't measure the weight of it. Thus, it is necessary to develop 3-axis force sensor that can measure the weight of an object and the force of grasping direction for an intelligent gripper. In this paper, 3-axis finger force sensor to grasp an unknown object safely in an intelligent robot's hand was developed. In order to fabricate a 3-axis finger force sensor, the sensing elements were modeled using parallel plate beams, and the theoretical analysis was performed to determine the size of sensing elements, then the 3-axis finger force sensor was fabricated. Also, the characteristic test of the developed 3-axis finger force sensor was performed.

A Study of the Hinge Axis Point (Hinge Axis Point에 관한 연구)

  • Jung, Kum-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.72-78
    • /
    • 1984
  • The notion that the axis of the shaft of the articulator must coincide the patient's mandibular transverse axis tells us the importance of locating the axis precisely. When using kinematic axis to transfer a cast to an articulator, the anatomic asymmetry of the contralateral points will result in certain distortion when the axis transferred to an articulator where the mechanical axis produces symmetry. In this study, after locating the true hinge axis point with Denar hinge axis locator, the discrepancies between true hinge axis point and arbitrary hinge axis point that was 13mm anterior from the posterior margin of center of trangus to the outer canthus of eye were measured. And the discrepancies between left and right true hinge axis point in the superoinferior and anteroposterior directions were measured. For this study, 20 dental students who have no missing teeth and no difficulties of mandibular movement were selected. Upper and lower cast of subjects were mounted on Denar Mark II articulator uisng Denar Slidematic face-bow and centric relation record for the measurement of discrepancies between left and right true hinge axis points. The results obtained as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right: horizontal distance; 1.99mm, vertical distance; 2.12mm, linear distance; 3.36 mm. Left: horizontal distance; 1.39mm, vertical distance; 2.06mm, linear distance; 2.09mm. Total: horizontal distance; 1.69mm, vertical distance; 2.09mm linear distance; 3.06 mm. 2. The 87.5% of true hinge axis points were within 5mm of the arbitrary hinge axis point. 3. The mean discrepancies between the right and left hinge axis point were 2.92mm in superoinferior direction and 4.74mm in anteroposterior direction. 4. When transferring the axis to the articulator, anatomic asymmetry between right: and left axis point produces in dislocation of cast on the articulator, and undesirable shift in esthetic tooth position will be resulted.

  • PDF

AN EXPERIMENTAL STUDY ON THE HINGE AXIS POINT (Hinge Axis Point에 관(關)한 실험적(實驗的) 연구(硏究))

  • Jo, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.11-16
    • /
    • 1976
  • Casts are often transferred to the articulator by arbitrary means, because the method of locating the true hinge axis point thought to be a complicated and time consuming procedure, and because the importance and significance of the true hinge axis in the construction of dental prosthesis is not sufficiently understood. In this report, the author constructed the hinge axis locator and determined the variations in location of the true hinge axis points from the location of the hinge axis point determined by arbitrary means. For this report, the procedure was followed on 50 persons with normal occlusion and sound T.M.J. function, so 100 true hinge axis points were recorded and compared with the arbitrary hinge axis point. The results obtained were as follows. 1. The mean distance from the arbitrary hinge axis point to the true hinge axis point was as follows. Right; (O)5.17mm., (V)3.44mm., (H)3.55mm.. Left; (O)5.63mm., (V)3.95mm., (H)3.51mm.. 2. The percentage of true hinge axis points classified at intervals of 2mm was as follows. 0-2mm; 4%, 2-4mm; 21%, 4-6mm; 37%, 6-8mm; 26%, 8-10mm; 10%, Over 10mm; 2%. And only 50% of the 100 true hinge axis points were located within a 5mm. radius of the arbitrary hinge axis point. 3. Instead of transferring the casts to the articulator by arbitrary means, the careful location of the true hinge axis points is recommended to avoid potential sources of error in mounting casts.

  • PDF

Three Axis Isotropic Field Strength Measuring Antenna (3축 등방성 전계강도 측정 안테나)

  • Choi, Suk-Hwan;Kim, Dong-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.9
    • /
    • pp.879-885
    • /
    • 2014
  • In this paper, we designed and fabricated wideband 3-axis isotropic antenna for the Electro-Magnetic Fields(EMFs) measurement. Each part of proposed 3-axis antenna has isotropic characteristics and arbitrary axis of proposed 3-axis antenna could be selectable using RF switch. Also, a resistor was inserted in each axis of proposed 3-axis antenna for improving antenna gain and noise suppression characteristics, and port impedance of each dipole antenna were matched by balun. For the performance verification of antenna, GTEM Cell which generates standard electromagnetic field was used for the derivation of antenna factor and receiver sensitivity. As a result, fabricated 3-axis isotropic antenna has receiver sensitivity of 0.12~4.2 mV/m and typical VSWR of 3.3:1 within a wide operation frequency range from 0.03 MHz to 3 GHz.

Steering Axis Analysis of Multi-link Suspensions with Bushing Compliance (컴플라이언스 특성을 고려한 멀티링크 현가장치의 조향축 해석)

  • Kim, Sang Sup;Kim, Seong Hun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.194-202
    • /
    • 2014
  • Steering axis of suspensions is an important factor that affects ride and handling quality in the vehicle chassis development. Macpherson strut and double wishbone's steering axis are defined geometrically, but multi-link suspensions can not be geometrically analyzed. In this case instant axis theory is commonly used to find a steering axis. Since the steering axis is moving with varying caster and kingpin inclination angle, this method approximately corresponds with exact solution. In this paper, we propose a velocity analysis method to find a pure rotational axis of the wheel relative to suspension arms, that is exact solution of the steering axis. This paper extends the method to analyze the steering axis of multi-link suspensions with bushing compliance. The analysis results applied to double wishbone and multi-link suspensions demonstrate validity and accuracy of the proposed method.

The properties of$Y_1Ba_2Cu_3O_{7-x}$ superconducting thin films deposited by 'off-axis' pulsed laser deposition (Off-axis'레이저 기법에 의한 고온 초전도 $Y_1Ba_2Cu_3O_{7-x}$박막의 특성)

  • 문병무
    • Electrical & Electronic Materials
    • /
    • v.8 no.3
    • /
    • pp.285-290
    • /
    • 1995
  • High quality $Y_{1}$Ba$_{2}$Cu$_{3}$$O_{7-x}$ thin films have been fabricated by pulsed Nd:YAG laser deposition using an unusual 'off-axis' target-substrate geometry. Various properties of superconducting $Y_{1}$Ba$_{2}$Cu$_{3}$$O_{7-x}$ thin films have been studied systematically as a function of oxygen pressure during the deposition, in both 'on-axis' and the unusual 'off-axis' target substrate geometries. In the 'off-axis' geometry, one can completely eliminate the so-called 'laser droplets' from the film surface and thus obtain smooth high quality films. It is found that films with optimum structural and electrical properties are obtained at a lower oxygen pressure range during the 'off-axis' deposition when compared with that required in the 'on-axis' deposition geometry.

  • PDF

Development and Performance Evaluation of an Ultra-Compact CT with Auto Calibration of Detector Center Axis (검출기 중심축을 자동 보정하는 초소형 CT 개발 및 성능평가)

  • Byeong-Woo Kwak;Keun-Ho Rew
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.651-662
    • /
    • 2023
  • In this study, we designed and fabricated an ultra-compact CT that automatically calibrates the detector's center axis and verified its performance. The three-dimensional reconstruction performance was evaluated using 3D CAD data and X-ray data acquired by manually calibrating the center axis of the CT detector. The results showed that tilting the center axis by more than 0.25° causes circle break phenomenon, which rapidly degrades the quality of the 3D reconstructed image. By applying the automatic calibration device of a detector center axis, the 3D reconstruction performance was enhanced by calibrating the detector center axis to match the specimen rotation axis.

TEM study on a-axis outgrowth formation in c-axis oriented YBa$_2$Cu$_3$O$_{7-{\delta}}$ thin films

  • Hahn, T.S.;Hong, K.S.;Kim, C.H.
    • 한국초전도학회:학술대회논문집
    • /
    • v.10
    • /
    • pp.51-55
    • /
    • 2000
  • Using modified melt-textured grown targets, YBa$_2$Cu$_3$O$_{7-{\delta}}$ thin films were prepared by pulsed laser deposition technique at the laser energy density from 1 J/cm$_2$ to 4 J/cm$_2$. All the films showed c-axis preferred orientations, however, a-axis outgrowths on the film surface were considerably increased with an increase of the laser energy density. To examine the origin of the a-axis outgrowth formation, the microstructures of films deposited at 2 J/cm$_2$ and 4 J/cm$_2$ were investigated using X-ray diffraction, transmission electron microscopy, and high-resolution electron microscopy. It was shown that a significant number of Y$_2$O$_3$ inclusions were formed during the growth of c-axis oriented films at 4 J/cm$_2$. These inclusions formed nucleation sites for the a-axis outgrowths. It is considered that, due to the unstable growth conditions with a high flux density of incident vapor species and the strain induced by the surrounding c-axis films, the Y$_2$O$_3$ inclusions would prefer the nucleation of α-axis grains.

  • PDF