• 제목/요약/키워드: 3-arm type

검색결과 258건 처리시간 0.028초

상완 신경총 손상에서 Steindler 주관절 굴곡 성형술 (Steindler Flexoplasty of Elbow in Brachial Plexus Injuries)

  • 한정수;정덕환;정비오;이경원
    • Archives of Reconstructive Microsurgery
    • /
    • 제14권1호
    • /
    • pp.63-69
    • /
    • 2005
  • Purpose: The purpose of this study was to analyze the clinical results after Steindler flexoplasty. Materials and Methods: We analyzed 6 cases who had nearly normal finger and wrist joint flexion function, but could not flex elbow joint actively because of upper arm type brachial plexus injury. We performed operation during the period from February 1997 to July 2003. There were 5 males and 1 female with mean age of 28 years (range: $19{\sim}51$ years) when Steindler flexoplasty was done. The average follow-up period was 3 years 11 months (range: 12 months${\sim}$7 years 4 months). We assessed active range of motion of elbow joint, muscle power and elbow function by Mayer & Green grade scale at last follow-up. We assessed how much they were favorable for Steindler flexoplasty and had improvement of upper extremity function and correction of deformity. Results: Postoperative, flexion range of elbow joint improved to average $111.7^{\circ}$ (range: $90{\sim}130^{\circ}$). $25.8^{\circ}$ (range: $15{\sim}45^{\circ}$) in flexion contracture and $16.6^{\circ}$ (range: $10{\sim}35^{\circ}$) in pronation contracture were remained. Range of motion of elbow joint improved to average $85.3^{\circ}$ (range: $45{\sim}105^{\circ}$). Flexion power of elbow joint improved to Grade 5 in all cases. Postoperatively on Mayer & Green grade scale, there were excellent in 3 cases(50%), good in 2 cases(33.3%), fair in 1 case(16.7%). On patient's own assessment of functional improvement, there were excellent in 4 cases(66.6%), good in 1 case(16.7%) and fair in 1 case(l6.7%). Conclusion: Steindler flexoplasty can reserve good clinical results with being improved to active flexion of elbow joint in cases who have functional hand and wrist, but paralysis upper arm muscle in brachial plexus injury.

  • PDF

홈 서비스 로봇을 위한 전용 머니퓰레이터의 구현에 관한 연구 (A Study on Implementation of Special-Purpose Manipulator for Home Service Robot)

  • 김승우;김하이준
    • 한국산학기술학회논문지
    • /
    • 제12권11호
    • /
    • pp.5219-5226
    • /
    • 2011
  • 본 논문에서는 홈서비스 로봇인 맥봇 II(McBot II)의 빌트인(Built-in) 로봇 팔과 핸드를 설계한다. 이 빌트인 타입의 로봇 머니퓰레이터는 각각 3 DOF(Degree-of-Freedoms)의 로봇팔과 3 DOF의 로봇핸드로 구성되어 진다. 제한된 공간에서 인간과 함께 생활하는 홈서비스 로봇에 탑재되는 머니퓰레이터는 최소의 로봇 크기와 최대의 작업 공간이라는 상반된 설계 스펙이 요구되어 진다. 즉, 최소의 질량과 팔 길이에도 불구하고 효율적 작업을 위한 공간 확보가 필요한 것이다. 본 논문에서는 이와 같은 상반된 문제를 해결하기 위하여 수직 방향으로 움직이는 로봇 허리 구조와 수평방향의 전후방으로 이동할 수 있는 어깨 관절을 이용한 태스크 기반의 설계 방법을 제안한다. 또한, 양손 협업시스템인 로봇 핸드도 4절 링크 핑거를 이용한 작업 기반 설계를 시도한다. 끝으로 본 논문에서는 구현된 빌트인 머니퓰레이터의 실제 동작 실험을 통하여 그 성능을 확인한다.

대동맥 축착증 수술 1례 (A Case of Coarctation of the Aorta)

  • 노중기
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.321-325
    • /
    • 1978
  • Coarctation of the aorta was rare condition among the congenital cardiovascular defects in Korea. We experienced a case of coarctatlon of the aorta [postductal type], which was successfully corrected by resection and end to end anastomosis. This patient, 21 years male patient, was admitted to the medical department for evaluation of hypertension, headache and exertional dyspnea during 4 years, and transferred to the department of chest surgery for operation. On physical examination, blood pressures were measured on both extremity, measuring 190/100mmHg on the arm and 100/80mmHg on the leg. Systolic murmur was heard on 2nd to 3rd left intercostal space and left sternal border. On simple chest x-ray, rib notching was seer/on low border of right 3rd and left 4th rib. Final preoperative diagnosis was made by the retrograde aortic catheterization and aortography, which showed the typical configuration of postductal type of coarctation with poststenotic dilatation of the aorta. On 20th, July, 1978, under the general anesthesia with endotracheal intubation, resection of coarctation of the aorta and end to end anastomosis was performed. During clamp for resection, blood pressure of upper extremity was elevated to 200/140mmHg, and controlled by Arfornad. During recovery, blood pressure over 160ramrig in systole was controlled by Reserpine for 8days postoperatively. At discharge, postoperative 8th day, brachial and femoral artery pressure was 145/85 mmHg and 135/80mmHg. After discharge, there was no evidence of specific symptoms and hypertension without antihypertensive drug.

  • PDF

경사지 트랙터용 차체 수평제어 시스템 개발 - 유압시스템의 수평제어 성능 - (Development of Leveling Control System for a Slope Land Tractor - Performance of leveling control by hydraulic system -)

  • 이상식;오기석;이재용;황헌
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.203-210
    • /
    • 2002
  • In this study, the leveling control system for a tractor has been developed. The experimental model showed that the implementation of the proposed hydraulic control system fur the prototype design of a slope land tractor was feasible. The front axle was designed as a center pin type and the rear axle was designed as a trailing arm type. The leveling control of the body on the slope land was accomplished by controlling the height of the right and left trailing arms using the electronic controlled hydraulic cylinder. The maximum leveling control angles were ${\pm}$15$^{\circ}$ for roll angle and 7$^{\circ}$far pitch angle. The front and rear wheel drives were transmitted by gears from the main shaft to the final drive. The adaptability of the hydraulic control system was tested and investigated by analyzing the system response in time and frequency domain. The hydraulic control system on a step input showed a linearly increasing trend without any overshoot state. The hydraulic control system on a frequency input showed a little phase differences and gain drops within the range of 0.3Hz.

평판 디스플레이용 유리의 평탄도 및 두께 측정을 위한 레이저 센서의 비교 분석 (A comparison and analysis of laser sensors for measuring the flatness and thickness of flat display glass)

  • 김순철;한창호;오춘석
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.71-79
    • /
    • 2008
  • 본 논문에서는 평판 디스플레이용 유리의 평탄 도와 두께를 측정하기 위한 검사시스템을 구성한다. 유리 계측에 필요한 레이저센서와 로봇 암의 성능을 분석 및 해석한다. 3가지 레이저 센서를 사용하여 비교 분석하였고, 로봇암은 볼 스크루 타입을 사용하여 유리 계측 방법을 논하고, 문제점을 찾아내어 해결책을 제시한다. 유리의 평탄도와 두께 측정에 있어 스테이지와 로봇암에 의한 오차를 최소화하기 위해서 기구적 오차를 고려한 계측을 통해 성능을 개선한다.

  • PDF

여대생의 체형별 신체만족도와 의복이미지 연구 (Body Cathexis and Clothing Image of Female Collegians by Somatotype)

  • 이미진;김양원
    • 한국지역사회생활과학회지
    • /
    • 제23권3호
    • /
    • pp.221-231
    • /
    • 2012
  • To find the differences between the real somatotype and the ideal somatotype, WHR(Waist to Hip Ratio), WCR(Waist to Chest Ratio), and body cathexis were analysed by using ANOVA test, Duncan's multiple range test, and $x^2$ test. Fashion image sought by female collegians was surveyed, too. The results were as follows. WHRs in slim, usual, fat body type were 0.75, 0.76, and 0.83 and WCRs were 0.77, 0.81, 0.80. The respondents who considered themselves to be overweight recognized themselves to be fatter than their real weight. They were not satisfied with their bust girth in slim body type, thighs and calves in usual body type, and all parts except for foot length, hand length and arm length in fat body type. 60% of the thin people considered their body hourglass shape, 30.4% of regular people recognized their body triangle type, 43.8% of fat people thought their body was round form. They thought current ideal body size was bigger in height and bust girth and smaller in waist girth and hip girth, and weight than real body size. Also they responded ideal body shape was an hourglass type independent of somatotype. The pursuit of clothing image was that 45.5% of female collegians were fashionable and raffine and 10.4% of female collegians was elegant and graceful. Among the body area, body parts that may have an effect on body image were body length in 13.1% of the respondents, waist girth in 10.7% of the respondents, and hip girth in 10.0% of the respondents.

Strawberry Harvesting Robot for Bench-type Cultivation

  • Han, Kil-Su;Kim, Si-Chan;Lee, Young-Bum;Kim, Sang-Chul;Im, Dong-Hyuk;Choi, Hong-Ki;Hwang, Heon
    • Journal of Biosystems Engineering
    • /
    • 제37권1호
    • /
    • pp.65-74
    • /
    • 2012
  • Purpose: An autonomous robot was developed for harvesting strawberries cultivated in bench-type systems. Methods: The harvest robot consisted of four main components: an autonomous vehicle, a manipulator with four degrees of freedom (DOF), an end effector with two DOFs, and a color computer vision system. Strawberry detection was performed based on 3D image and distance information obtained from a stereo CCD color camera and a laser device, respectively. Results: In this work, a Cartesian type manipulator system was designed, including an intermediate revolute axis and a double driven arm-based joint axis, so that it could generate collision-free motions during harvesting. A DC servomotor-driven end-effector, consisting of a gripper and a cutter, was designed for gripping and cutting the strawberry stem without damaging the strawberry itself. Real-time position tracking algorithms were developed to detect, recognize, trace, and approach strawberries under natural light conditions. Conclusion: The developed robot system could harvest a strawberry within 7 seconds without damage.

Enhanced Stability of Tyrosine Phenol-Lyase from Symbiobacterium toebii by DNA Shuffling

  • Kim, Jin-Ho;Song, Jae-Jun;Kim, Bong-Gyun;Sung, Moon-Hee;Lee, Sang-Chul
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권1호
    • /
    • pp.153-157
    • /
    • 2004
  • Tyrosine phenol-lyase (TPL) is a useful enzyme for the synthesis of pharmaceutical aromatic amino acids. In the current study, sequential DNA shuffling and screening were used to enhance the stability of TPL. Twenty-thousand mutants were screened, and several improved variants were isolated. One variant named A13V, in which the $13^{th}$ amino acid alanine was substituted by valine, exhibited a higher temperature and denaturant stability than the wild-type TPL. The purified mutant TPL, A13V, retained about 60% of its activity at $76^\circ{C}$, whereas the activity of the wild-type TPL decreased to less than 20% at the same temperature. Plus, A13V exhibited about 50% activity with 3 M urea, while the wild-type TPL lost almost all its catalytic activity, indicating an increased denaturant tolerance in the mutant A13V. It is speculated that the substitution of Val for the Ala in the $\beta$-strand of the N-terminal arm was responsible for the heightened stabilization, and that the current results will contribute to further research on the structural stability of TPL.

적외선 체열촬영을 이용한 배변습관과 하복 및 수족 냉증의 관련성 고찰 (Clinical Research about the Correlation between Defecation Type and Cold Hypersensitivity of Lower Abdomen, Hand and Foot)

  • 윤성우;하지연;이경섭
    • 대한한방체열의학회지
    • /
    • 제3권1호
    • /
    • pp.36-42
    • /
    • 2004
  • Cold hypersensitivity is the condition with unusual cold sensitivity at temperature when others don't feel so. It is not disease in itself, but is known as having relationship with infertility, dysmenorrhea, anemia and endocrine disorder. The symptoms of cold hypersensitivity appear on limbs and abdomen especially, and may affect bowel movement such as constipation or diarrhea. We made a research of 86 healthy young girls who took medical examination and examined subjective bowel habit. The patients were divided into three group by defecation type, constipation(42), diarrhea(14) and normal group(30). Temperature differences$({\Delta}Ts)$ measured by DITI on upper and lower abdomen of each group had not statistically significance. Otherwise ${\Delta}Ts$ between upper arm and palm and between upper leg and foot were statistically signigicant. The severity of cold hypersensitivity on hands was in order constipation, normal and diarrhea group, and same as feet. The diarrhea patients had more severe cold hypersensitivity as compared with constipation patients. Correlation between ${\Delta}Ts$ on abdomen and hands or feet didn't exist. ${\Delta}Ts$ on hands and feet, however, had positive relationship. This research showed cold hypersensitivity could be related with diarrhea.

  • PDF

학령후기 여아의 상반신 체형 연구 (A Study on the Upper Body Shapes of Late Elementary Schoolgirls)

  • 장정아
    • 한국의류산업학회지
    • /
    • 제8권1호
    • /
    • pp.107-112
    • /
    • 2006
  • This study is done to classify the upper body shapes for late elementary schoolgirls. The sampling was done for 11~12 years-old-girls resident in Busan and Kyungnam. Based on the somatometric charateristics of them, 33 anthropometic and 7 photogrphic measurment data were acquired from every girl. These data are statistically analyzed with the following methods; Factor Analysis, Cluster Analysis, and Discriminant Analysis. Resulting from the factor analysis, it is shown that 79.95% of the whole variances can be explained with 8 factors. Through the cluster analysis, 3 types of upper body shapes can be categorized as follows: Type I has average horizontal size, big vertical size and lots of protruded chest ; Type III has big horizontal size, the mean vertical size, and big upper angle of the back ; Type II has small horizontal and vertical size and long surface length of the upper body. Through the discriminant analysis, the high discriminative items in discriminant function are follows: Upper chest circumference, arm length and waist front length of discriminant function I and waist depth, front length, back breadth, nipple to nipple breadth and upper chest circumference of discriminant function II have large coefficient values.