• 제목/요약/키워드: 3-Mass System

검색결과 2,648건 처리시간 0.03초

Distribution of Baryonic Matter in Dark Matter Halos: Effect of Dynamical Friction

  • 배영복;이형목
    • 천문학회보
    • /
    • 제36권1호
    • /
    • pp.47.1-47.1
    • /
    • 2011
  • We studied the evolution of the two mass components system with NFW initial density distribution by direct integration of the Fokker-Planck equations. The low mass component is regarded the dark matter particles while the high mass component is assumed to be conglomerates of baryonic matter in order to depict the 'stars'. While the true mass ratio between these two types of particles should be extremely large, our adopted mass ratio is about 1000 beyond which the dynamical evolution and density distribution tend to converge. Since the dynamical evolution is dominated by the dynamical friction, the high mass component slowly moves toward the central part, and eventually undergoes the core collapse. The system reaches the core-collapse at about $7.1{\times}10^{-3}$ $t_{fh}$ in NFW models, where $t_{fh}$is the dynamical friction time at half-mass radius. The distribution of the high mass component is well fitted by the Sersic profiles or modified Hubble profile when the mass segregation is established. From these results, the surface brightness of elliptical galaxies may be explained by the high mass component experiencing dynamical friction by the dark matter particles. In order for the mass segregation to be effective within Hubble time, the mass of the luminous component should be greater than $10^5M_{\bigodot}$.

  • PDF

디지털 영상 시스템을 이용한 알루미늄 당량화상에 의한 골량 측정에 관한 연구 (A study on assessment of bone mass from aluminum-equivalent image by digital imaging system)

  • 김진수;최의환;김재덕
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.87-97
    • /
    • 1997
  • The purpose of this study was to evaluate the method for quantitative assessment of bone mass from aluminum-equivalent value of hydroxyapatite by using digital imaging system consisted of Power Macintosh 7200/120, 15-inch color monitor, and GT-9000 scanner with transparency unit. After aluminum-equivalent image made from correlation between aluminum thickness and grey scale, the accuracy of conversion to mass from aluminum-equivalent value was evaluated. Measured bone mass was compared with converted bone mass from aluminum-equivalent value of hydroxyapatite block by correlation formula between aluminum-equivalent value of hydroxyapatite block and hydroxyapatite mass. The results of this study were as follow; 1. Correlation between aluminum thickness and grey level for obtaining aluminum-equivalent image was high positively associated(r²=0.99). Converted masses from aluminum-equivalent value were very similar to measured masses. There was, statistically, no significant difference(P<0.05) between them 2. Correlation between hydroxyapatite aluminum-equivalent and hydroxyapatite mass was shown to linear relation (r²=0.95). 3. Converted masses from aluminum-equivalent value of 3 dry mandible segments were similar to measured masses. The difference between the exposure directions was not significantly different(P<0.05).

  • PDF

On the eigenvalues of a uniform rectangular plate carrying any number of spring-damper-mass systems

  • Chen, Der-Wei
    • Structural Engineering and Mechanics
    • /
    • 제16권3호
    • /
    • pp.341-360
    • /
    • 2003
  • The goal of this paper is to determine the eigenvalues of a uniform rectangular plate carrying any number of spring-damper-mass systems using an analytical-and-numerical-combined method (ANCM). To this end, a technique was presented to replace each "spring-damper-mass" system by a massless equivalent "spring-damper" system with the specified effective spring constant and effective damping coefficient. Then, the mode superposition approach was used to transform the partial differential equation of motion into the matrix equation, and the eigenvalues of the complete system were determined from the associated characteristic equation. To verify the reliability of the presented theory, all numerical results obtained from the ANCM were compared with those obtained from the conventional finite element method (FEM) and good agreement was achieved. Since the order of the property matrices for the equation of motion obtained from the ANCM is much lower than that obtained from the FEM, the CPU time required by the ANCM is much less than that by the FEM.

탄성 지지된 밸브 배관계의 안정성에 미치는 크랙의 영향 (Crack Effects on Dynamic Stability of Elastically Restrained Valve-pipe System)

  • 허관도;손인수
    • 한국기계가공학회지
    • /
    • 제10권3호
    • /
    • pp.79-86
    • /
    • 2011
  • The dynamic instability and natural frequency of elastically restrained pipe conveying fluid with the attached mass and crack are investigated. The pipe system with a crack is modeled by using extended Hamilton's Principle with consideration of bending energy. The crack on the pipe system is represented by a local flexibility matrix and two undamaged beam segments are connected. In this paper, the influence of attached mass, its position and crack on the dynamic stability of a elastically restrained pipe system is presented. Also, the critical flow velocity for the flutter and divergence due to the variation in the position and stiffness of supported spring is studied. Finally, the critical flow velocities and stability maps of the pipe conveying fluid with the attached mass are obtained by the changing parameters.

수치적 방법에 의한 승용차 동적해석 (Dynamic analysis of vehicle system using numerical method)

  • 이종원;박윤식;조영호
    • 오토저널
    • /
    • 제5권3호
    • /
    • pp.45-55
    • /
    • 1983
  • This paper discussed about Application Technique of Numerical Methods for large structure. The dynamic behaviours of a vehicle were investigated through finite element modelling. After dividing a vehicle body into three substructures, Basic Mass System was composed of 60 flexual modes which was obtained from the dynamic characteristics of each substructure using Modal Synthesis Method. Engine, transmission and rear axle, etc. were added to Basic Mass Model, consequently Full Mass System was constructed by 72 degree of freedoms. Full Mass System was analyzed over the frequency range 0.5-50.0 Hz under the loading conditions which were Stationary Gaussian Random Process. Results and discussions provided the guidelines to eliminate resonances among the parts and to improve the Ride Quality. The Absorbed Power was used as a standard to determine the Ride Quality. The RMS value of driver's vertical acceleration was obtained 0.423g from the basic model and 0.415g from the modified model.

  • PDF

Adaptive mass flow method 유압압하식 자동 두께제어 장치에 관한 연구 (A Study on the Hydraulic Automatic Gauge Control System of Adaptive Mass Flow Method)

  • 윤순현;김문경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권4호
    • /
    • pp.101-107
    • /
    • 1996
  • This test was performed on the hydraulic automatic gauge control(AGC) system of adaptive mass flow method. Fundamental purpose of this study are performance evaluation of this AGC system under the actual rolling condition. It was concluded that the response of AGC system depends on the dynamic characteristics of a reel motor or roll position. The test results are as follows : 1) The control method of reel motor current is better than than of the roll position as AGC system. 2) The more steel strip thickness of delivery side is thick, the larger the gauge deviation is large, and the more it is thin, the larger the gauge deviation rate is large. 3) Because the gauge deviation is large at acceleration and deceleration speed than steady speed, so AGC system is better to adopt over 50m/min. By applying this AGC system, not only the accurary in strip thickness were improved but also productivity was improved dramatically.

  • PDF

간접촬영기의 디지털 영상 변환 장치 적용에 대한 연구 (A study on the digital image transfer application mass chest X-ray system up-grade)

  • 김선칠;박종삼;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제26권3호
    • /
    • pp.13-17
    • /
    • 2003
  • 현대 병원들은 보다 나은 의료서비스를 위해 디지털 시스템을 갖추고자 노력하고 있다. 하지만, 아직도 많은 부분은 아날로그 시스템과 Film 출력에 의존하고 있다. 본 연구는 차량 이동형 흉부 전용 간접 촬영기에 디지털 영상 변환 장치와 이에 연동되는 X-ray 발생장치의 제어 시스템, 출력 시스템을 디지털시스템으로 변환, 연동시켰으며, 획득한 영상을 간접 촬영 전용프로그램에서 편리하게 판독 할 수 있도록 설계하여 임상에 적용시켰다. 이러한 과정에서 발생되는 문제점을 현실적으로 해결하였으며, 방사선사 입장에서 업무의 효율성을 높이고자 몇 가지 프로그램을 개발 적용하였다. 향후 미래지향적인 디지털의료 영상 시스템을 갖추기 위해 각종 프로그램과 시스템과도 연동이 되도록 설계하여 임상에 적용하여 우수성을 입증하였다.

  • PDF

7RT급 암모니아 흡수식 냉온수기의 냉방성능 특성 (The Characteristics of Cooling Performance on 7RT Ammonia Absorption System)

  • 이호생;진병주;윤정인;황준현;진심원;경익수
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.433-438
    • /
    • 2009
  • Experimental results for performance characteristics of small $NH_3$ absorption chiller/ heater are presented. The apparatus consists of 7RT water-cooled absorption system, solution pump, boiler, cooling tower and peripheral devices. The effect of experimental parameters, such as refrigerant mass flow rate, solution mass flow rate and cooling water temperature have been investigated in view of the system performance. The capacity of each heat exchanger increased as refrigerant mass flow rate increased in cooling mode. Also, a cooling capacity increased as a strong solution mass flow rate increased. The cooling and heating COP show 0.5, 1.5 regardless of refrigerant mass flow rate, respectively. The results focus on the evaluation for performance characteristics of system with respect to variation of refrigerant mass flow rate under standard design conditions.

암반 사면에 대한 새로운 암반 분류안의 적용 (Applicaton of a Geomechanical Classification for Rock Slope)

  • 김대복
    • 터널과지하공간
    • /
    • 제4권3호
    • /
    • pp.215-227
    • /
    • 1994
  • Rock Mass classifications have been developed in many European countries. The most widely used classification methods are the Rock Mass Rating (RMR) system proposed by Bieniawski(1973) and the Q-system developed By Barton et al. (1974). These methods are also adopted at many mountain tunnels and subway sites in our country. Here, a geomechanical classification for slopeds in rock, the "Slope Mass Rating"(SMR) is presented for the preliminary assessment of slope stabiliyt. This method can be applied to excavation and support design in the front part of tunnel and cutting area as a guide line and recommendation on support methods which allow a systemmetic use of geomechanical classification for rock slopes.

  • PDF

친환경차 확산전략에 대한 시스템다이내믹스 접근과 인과지도 분석 (System Dynamics Approaches on Green Car Diffusion Strategies and the Causal Diagram Analysis)

  • 박경배
    • 한국시스템다이내믹스연구
    • /
    • 제13권4호
    • /
    • pp.33-55
    • /
    • 2012
  • The research is to identify important diffusion factors and their effects on green car diffusion process using system dynamics perspectives and a causal-loop analysis. Through a deep review on previous research, we have found the important factors of green car diffusion process. Price, driving range, network effect, recharge system, fuel cost had important facilitation on consumer attraction and green car diffusion. Based on the review, we have constructed a causal loop diagram explaining hybrid car diffusion process. We have found 3 important reinforcing loops in the causal loop diagram. Loop for learning & economies of scale(supply side), loop for network effect(consumer side), and loop for battery development(technology side) had most significant roles in the whole diffusion process. Through a deliberate analysis on the 3 causal loops, we have found meaningful results. First, there seems to exist a critical mass in the diffusion. Second, of the 3 loops, the battery technology had most significant role. Third, not consumer installed base but sales must be a standard to decide whether the critical mass is achieved or not. Based on these findings, several meaningful implications are suggested for the government and corporations related to the green car industries.

  • PDF