방사선수술을 위한 3차원 정위 시스템 및 방사선량 측정 시스템 개발 (Development of 3-D Stereotactic Localization System and Radiation Measurement for Stereotactic Radiosurgery)

  • 서태석;서덕영;박승훈;장홍석;최보영;윤세철;신경섭;박용휘;김일환;강위생;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.25-36
    • /
    • 1995
  • The purpose of this research is to develop stereotactic localization and radiation measurement system for the efficient and precise radiosurgery. The algorithm to obtain a 3-D stereotactic coordinates of the target has been developed using a Fisher CT or angio localization. The procedure of stereotactic localization was programmed with PC computer, and consists of three steps: (1) transferring patient images into PC; (2) marking the position of target and reference points of the localizer from the patient image; (3) computing the stereotactic 3-D coordinates of target associated with position information of localizer. Coordinate transformation was quickly done on a real time base. The difference of coordinates computed from between Angio and CT localization method was within 2 mm, which could be generally accepted for the reliability of the localization system developed. We measured dose distribution in small fields of NEC 6 MVX linear accelerator using various detector; ion chamber, film, diode. Specific quantities measured include output factor, percent depth dose (PDD), tissue maximum ratio (TMR), off-axis ratio (OAR). There was small variation of measured data according to the different kinds of detectors used. The overall trends of measured beam data were similar enough to rely on our measurement. The measurement was performed with the use of hand-made spherical water phantom and film for standard arc set-up. We obtained the dose distribution as we expected. In conclusion, PC-based 3-D stereotactic localization system was developed to determine the stereotactic coordinate of the target. A convenient technique for the small field measurement was demonstrated. Those methods will be much helpful for the stereotactic radiosurgery.

  • PDF

QA용 두부 팬톰을 이용한 Hitchcoke CT 및 혈관조영 정위적 시스템에 대한 정확도 평가 (Evaluation of Accuracy on Hitchcoke CT/angio localization system using QA head phantom)

  • 김성현;서태석;윤세철;손병철;김문찬;신경섭
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.1-9
    • /
    • 1998
  • 정위적 방사선 수술과 신경외과적 수술분야 에서는 상호보완적인 영상정보를 얻기 위하여 컴퓨터 단층촬영 (CT), 자기공명영상 (MRI) 그리고 혈관조영촬영이 사용된다. 본 연구의 목적은 여러 영상장치와 다목적 QA(Quality Control) 팬톰을 이용하면서, 정위적 방사선수술 및 신경외과적 수술분 야에서 두경부내의 병소에 대한 모양, 크기, 위치를 정확하게 결정하기 위한 3 차원 정위 시스템을 개발하는 것이다. 목표물의 정확한 위치를 정의하기 위하여, Hitchcoke 정위 프레임과 컴퓨터 단층 촬영 (CT)/혈관 조영촬영용 위치측정 보조기구들을 3차원 공간상에 9개의 목표물을 가진 팬톰에 고정하였다. 컴퓨터 단층촬영과 혈관 조영촬영을 이용하여 얻은 기하학적 팬톰의 영상들을 이용하여, 목표물의 3차원 정위좌표를 얻기위한 알고리즘이 개발되었다. 개발된 알고리즘에 의해 계산된 목표물들의 위치는 팬톰의 절대 좌표와 비교 되었고, 각 CT 영상에서의 목표물들은 뇌혈관촬영 영상위에 상호 중첩될 수 있도록 개발 되었다. 512$\times$512 메트릭스와 2mm 슬라이스 두께를 가진 컴퓨터 단층촬영에 있어서는 1.02$\pm$0.17 mm의 평균거리오차를 보였고, 혈관 조영촬영인 경우에는 0.41$\pm$0.05mm 의 평균거리오차를 보였다. 목표물의 위치를 결정하는데 있어서 결과로 나온 정확도는 개발된 시스템이 정위적 방사선수술과 신경외과적수술을 위해 충분히 신뢰성이 있음을 확인해주었다.

  • PDF

컴퓨터 단층촬영, 자기공명영상, 뇌혈관촬영을 이용한 정위적 수술시스템의 개발 (Development of Stereotactic Surgery system with CT, MR Imaging, and Angiography)

  • 김성현;서태석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.117-118
    • /
    • 1998
  • The aim of this work is to develop 3-D stereotactic localization system in order to determine the precise shape, size and location of the lesion in the brain in the field of Stereotactic Radiosurgery(SRS) and neurosurgery using CT/MRI/angiography and multi-purpose QA phantom. The algorithms to obtain a 3-D stereotactic coordinates of the target have been developed, and targets on each CT image were superimposed each other on MR/angiography images without distortion corretion. This system was implented in Visual C++ as a PC-based application program.

  • PDF

IBM Personal Computer를 이용한 3차원적 뇌정위 방사선 수술계획 시스템의 개발 (Development of 3-D Radiosurgery Planning System Using IBM Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생;박승훈;윤세철
    • Radiation Oncology Journal
    • /
    • 제11권1호
    • /
    • pp.167-174
    • /
    • 1993
  • Recently, stereotactic radiosurgery plan is required with the information of 3-D image and dose distribution. A project has been doing if developing LINAC based stereotactic radiosurgery since April 1991. The purpose of this research is to develop 3-D radiosurgery planning system using personal computer. The procedure of this research is based on two steps. The first step is to develop 3-D localization system, which input the image information of the patient, coordinate transformation, the position and shape of target, and patient contour into computer system using CT image and stereotactic frame. The second step is to develop 3-D dose planning system, which compute dose distribution on image plane, display on high resolution monitor both isodose distribution and patient image simultaneously and develop menu-driven planning system. This prototype of radiosurgery planning system was applied recently for several clinical cases. It was shown that our planning system is fast, accurate and efficient while making it possible to handle various kinds of image modalities such as angiography, CT and MRI. It makes it possible to develop general 3-D planning system using beam's eye view or CT simulation in radiation therapy in future.

  • PDF

A Study for Optimal Dose Planning in Stereotactic Radiosurgery

  • Suh, Tae-suk
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.23-29
    • /
    • 1990
  • In order to explane the stereotactic procedure, the three steps of the procedure (target localization, dose planning, and radiation treatment) must be examined separately. The ultimate accuracy of the full procedure is dependent on each of these steps and on the consistancy of the approach The concern in this article was about dose planning, which is a important factor to the success of radiation treatment. The major factor in dose planning is a dosimetry system to evaluate the dose delivered to the target and normal tissues in the patient, while it generates an optimal dose distribution that will satisfy a set of clinical criteria for the patient. A three-dimensional treatment planning program is a prerequisite for treatment plan optimization. It must cover 3-D methods for representing the patient, the dose distributions, and beam settings. The major problems and possible modelings about 3-D factors and optimization technique were discussed to simplify and solve the problems associatied with 3-D optimization, with relative ease and efficiency. These modification can simplify the optimization problem while saving time, and can be used to develop reference dose planning system to prepare standard guideline for the selection of optimum beam parameters, such as the target position, collimator size, arc spacing, the variation in arc length and weight. The method yields good results which can then be simulated and tailored to the individual case. The procedure needed for dose planning in stereotactic radiosurgery is shown in figure 1.

  • PDF

Personal Computer를 이용한 3차원적 뇌정위적 방사선 치료계획 (3-D Radiosurgery Planning Using Personal Computer)

  • 서태석;서덕영;박찬일;하성환;강위생
    • 한국의학물리학회지:의학물리
    • /
    • 제3권1호
    • /
    • pp.63-69
    • /
    • 1992
  • 최근 3차원적인 영상 데이타 및 방사선량 분포에 대한 정보를 필요로하는 뇌정위적 방사선 치료계획이 절실히 요구되고 있다. 본 연구의 목적은 personal computer를 이용하여 3차원적인 환자영상 데이터 및 선량분포를 함께 처리할 수 있는 치료계획 시스템을 개발하는 데 있다. 본 연구를 위한 처리 과정은 크게 3단계로 나누어 수행된다. 첫째, 환자영상 데이타 입력과정으로서, CT, MRI 등 단층촬영영상을 on-line 및 digitizer 방식을 통하여 personal computer에 입력시킨다 병소위치 및 모양도 Angio 및 CT localization 방법을 이용하여 함께 입력시킨다. 둘째, 선량계산 단계로서, stereotactic frame 좌표로 변환된 영상내에서 선량 분포를 계산하고 환자영상 데이타 및 치료기의 조사조건등에 따라 최적 선량분포를 얻는다. 셋째, display 과정으로서, 임의의 단층영상 및 재구성 영상내에서 환자영상과 방사선량에 대한 영상을 합성하여 computer monitor를 통하여 단일 영상내에 동시에 묘출할 수 있도록 처리한다. 본 연구의 치료계획 시스템을 응용한 바 치료계획을 신속하고 정확하게 처리할 수 있었으며, Angio, CT 혹은 MRI와 같은 여러형태의 영상내에서 선량분포를 동시에 묘출함으로써 능률적인 치료계획을 세울 수 있었다. 이와같은 치료계획의 자동화 시스템은 지금까지 어려웠던 3차원적인 뇌정위적 방사선치료계획을 가능케 하며, 추후 beam's eye view나 CT simulation을 통한 일반적인 3차원 방사선 치료계획에도 크게 이바지할 것으로 기대된다.

  • PDF

자기공명영상을 이용한 두개부내 표적의 3차원적 위치결정 (Determination of Stereotactic Target Position with MR Localizer)

  • 최태진;김옥배;주양구;서수지;손은익
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.67-77
    • /
    • 1996
  • 목적 : 전신자기공명영상장치의 두개부코일링에 삽입할 수 있는 뇌정위표적기를 제작하고, 횡단면, 시상면 및 관상면에서 표적의 입체적 위치를 결정하여 비교하였다. 방법 : 고강도 합성수지를 이용하여 1.5T 의 전신자기공명 영상장치에서 뇌정위시술용 두 개 부고정환에 부착하여 두개부내 표적위치를 결정할 수 있는 뇌정위표적기를 시험제작하였다. 본 연구에서 시험제작된 뇌정위표적기는 자기공명장치 Magnetom 1.5T(Siemens사, 독일)의 두부코일(외경이 260mm) 내에 설치할 수 있도록 하였으며, 횡단면이나 시상면 또는 관상면에서 표적의 위치를 3차원적으로 결정할 수 있게 하여 각 단면에서 결정된 가상표적의 위치를 비 교하였다. 결과 : 위치가 서로 다른 2개의 가상표적에 대한 모의실험 결과, 횡단면에서 x축의 최대오차는 -1.4mm, y축 -0.7mm, z축 1.lmm를 얻었으며, 시상면에서는 X축 1.3, Y축 1.0mm, Z축 1.lmm, 관상면에서는 X축 -1.4mm, Y축 1.1mm, Z축 -1.5mm로 나타나 횡단면, 시상면 및 관상면에서 구한 표적값이 실험오차범위에서 거의 일치하였다. 결론 : 고강도 합성수지를 이용하여 시험제작한 자기공명영상용 뇌정위표적기를 이용하여 두개부내 표적에 대한 모의실험결과 횡단면, 시상면 및 관상면에서 구해진 표적의 위치가 2mm의 오차범위내에서 실제값에 거의 일치함을 얻었다.

  • PDF

동적 팬톰을 이용한 사이버나이프 호흡동기 추적장치의 위치 정확성 평가 (Estimation of CyberKnife Respiratory Tracking System Using Moving Phantom)

  • 서재혁;강영남;장지선;신헌주;정지영;최병옥;최일봉;이동준;권수일;임종수
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.324-330
    • /
    • 2009
  • 본 연구에서는 정위방사선수술시 움직이는 목표점에 대한 사이버나이프 호흡동기추적장치의 위치 정확성 및 유용성을 평가하고자 한다. 본 연구를 위해 움직이는 목표점을 재현할 수 있는 동적팬톰을 사용하였으며 움직이는 목표점 추적을 위하여 사이버나이프의 호흡동기추적장치인 $Synchrony^{TM}$ 시스템을 사용하였다. 움직이는 목표점의 치료계획을 위하여 4D CT를 이용한 영상획득을 하였고 움직이는 목표점에서의 선량분포와 점선량 측정을 위하여 gafchromic EBT 필름과 0.62 cc 이온 전리함을 사용하였다. 호흡동기추적장치의 정확성을 평가하기 위하여 팬톰의 목표점을 움직였을 때와 정지 상태일 때 목표점에서의 선량분포(처방선량기준 선량분포의 80%)를 비교하였으며 목표점에서의 점선량을 측정하였다. 위치추적장치와 호흡동기추적장치 상호간의 동기화에 의한 정확성은 동기화 되지 않을 경우 평균 $11.5{\pm}3.09\;mm$였으며 동기화 되었을 경우 $0.14{\pm}0.08\;mm$의 차이를 나타내었다. 목표점 정지상태시의 영상과 4D CT를 이용한 움직이는 목표점에 대한 영상을 이용하여 치료계획상의 정확성은 평균 $0.18{\pm}0.06\;mm$의 차이를 나타내었다. 또한 호흡동기추적장치의 정확성은 1 mm 이하로 나타났다. 호흡동기추적장치의 유효성을 확인하기 위하여 움직이는 목표점에 대하여 호흡동기추적장치를 중지하여 측정한 결과 평균 $17.39{\pm}0.14\;mm$였으며 가동하였을 때 $1.37{\pm}0.11\;mm$로 나타났다. 목표점에서의 선량값을 비교한 결과 목표점이 정지상태일 때 $0.68{\pm}0.38%$, 호흡동기추적장치를 이용한 움직이는 목표점에서는 $1.31{\pm}0.81%$의 차이를 나타내었다. 위치추적장치와 호흡동기추적장치 상호간의 동기화에 의한 정확성 확인에서 장치사이에서 동기화가 매우 정확하게 수행됨을 확인하였다. 본 연구의 결과 움직이는 목표점에 대한 정위방사선수술시 호흡동기추적장치를 필수적으로 사용해야하며 본 연구에서 사용된 사이버나이프의 호흡동기추적장치인 Synchrony 시스템의 유용성과 정확성을 평가한 결과 매우 정확함을 확인하였다.

  • PDF