• Title/Summary/Keyword: 3-D position

Search Result 2,275, Processing Time 0.038 seconds

Coordinate Determination for Texture Mapping using Camera Calibration Method (카메라 보정을 이용한 텍스쳐 좌표 결정에 관한 연구)

  • Jeong K. W.;Lee Y.Y.;Ha S.;Park S.H.;Kim J. J.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.4
    • /
    • pp.397-405
    • /
    • 2004
  • Texture mapping is the process of covering 3D models with texture images in order to increase the visual realism of the models. For proper mapping the coordinates of texture images need to coincide with those of the 3D models. When projective images from the camera are used as texture images, the texture image coordinates are defined by a camera calibration method. The texture image coordinates are determined by the relation between the coordinate systems of the camera image and the 3D object. With the projective camera images, the distortion effect caused by the camera lenses should be compensated in order to get accurate texture coordinates. The distortion effect problem has been dealt with iterative methods, where the camera calibration coefficients are computed first without considering the distortion effect and then modified properly. The methods not only cause to change the position of the camera perspective line in the image plane, but also require more control points. In this paper, a new iterative method is suggested for reducing the error by fixing the principal points in the image plane. The method considers the image distortion effect independently and fixes the values of correction coefficients, with which the distortion coefficients can be computed with fewer control points. It is shown that the camera distortion effects are compensated with fewer numbers of control points than the previous methods and the projective texture mapping results in more realistic image.

Mixed-reality simulation for orthognathic surgery

  • Fushima, Kenji;Kobayashi, Masaru
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.13.1-13.12
    • /
    • 2016
  • Background: Mandibular motion tracking system (ManMoS) has been developed for orthognathic surgery. This article aimed to introduce the ManMoS and to examine the accuracy of this system. Methods: Skeletal and dental models are reconstructed in a virtual space from the DICOM data of three-dimensional computed tomography (3D-CT) recording and the STL data of 3D scanning, respectively. The ManMoS uniquely integrates the virtual dento-skeletal model with the real motion of the dental cast mounted on the simulator, using the reference splint. Positional change of the dental cast is tracked by using the 3D motion tracking equipment and reflects on the jaw position of the virtual model in real time, generating the mixed-reality surgical simulation. ManMoS was applied for two clinical cases having a facial asymmetry. In order to assess the accuracy of the ManMoS, the positional change of the lower dental arch was compared between the virtual and real models. Results: With the measurement data of the real lower dental cast as a reference, measurement error for the whole simulation system was less than 0.32 mm. In ManMoS, the skeletal and dental asymmetries were adequately diagnosed in three dimensions. Jaw repositioning was simulated with priority given to the skeletal correction rather than the occlusal correction. In two cases, facial asymmetry was successfully improved while a normal occlusal relationship was reconstructed. Positional change measured in the virtual model did not differ significantly from that in the real model. Conclusions: It was suggested that the accuracy of the ManMoS was good enough for a clinical use. This surgical simulation system appears to meet clinical demands well and is an important facilitator of communication between orthodontists and surgeons.

Motion Plane Estimation for Real-Time Hand Motion Recognition (실시간 손동작 인식을 위한 동작 평면 추정)

  • Jeong, Seung-Dae;Jang, Kyung-Ho;Jung, Soon-Ki
    • The KIPS Transactions:PartB
    • /
    • v.16B no.5
    • /
    • pp.347-358
    • /
    • 2009
  • In this thesis, we develop a vision based hand motion recognition system using a camera with two rotational motors. Existing systems were implemented using a range camera or multiple cameras and have a limited working area. In contrast, we use an uncalibrated camera and get more wide working area by pan-tilt motion. Given an image sequence provided by the pan-tilt camera, color and pattern information are integrated into a tracking system in order to find the 2D position and direction of the hand. With these pose information, we estimate 3D motion plane on which the gesture motion trajectory from approximately forms. The 3D trajectory of the moving finger tip is projected into the motion plane, so that the resolving power of the linear gesture patterns is enhanced. We have tested the proposed approach in terms of the accuracy of trace angle and the dimension of the working volume.

A Comparative Study on Virtual Try-on Systems using Body Measurement Input

  • Lim, Ho-Sun;Istook, Cynthia
    • The International Journal of Costume Culture
    • /
    • v.13 no.2
    • /
    • pp.118-129
    • /
    • 2010
  • Digital technology introduced into the clothing and fashion industry is evolving to digital virtual fashions and consumer-centered mass-customized production systems. Today the application of such 3D virtual try-on systems is being expanded gradually in the clothing industry. This study purposed to make virtual avatars and virtual garments using OptiTex and V-stitcher virtual software and compared the appearance of the virtual garments put on the virtual avatars. For this, we created virtual avatars and virtual garments using body measurements obtained from jive subjects of top jive body shapes, respectively, using $[TC]^2$ body scanner. According to the results of comparing the outcomes of the two different virtual software systems, virtual avatar II of V-Stitcher tended to have a more round and lifted hip and the waist line at a higher position. In addition, the body curves and shapes of a virtual avatar affect the appearance of virtual garments. This study applied the same body measurements to virtual avatars and the same pattern to virtual garments, but when different kinds of virtual software were used, the virtual avatars and virtual garments showed different appearance and fit. This result may mean that when customers buy apparel products using different kinds of virtual try-on systems, their evaluation of appearance can vary depending on the virtual try-on system. Therefore, research needs to be made actively for the development and use of linkage programs that can reflect actual body measurements between virtual software systems and 3D body scanning systems.

  • PDF

Analysis of Neck Fit-zone according to Body Type for Females in Their 60s (60대 여성 체형별 목 부위 피트존 분석)

  • Park, Sunhee;Hong, Kyunghi;Lee, Yejin
    • Fashion & Textile Research Journal
    • /
    • v.20 no.4
    • /
    • pp.429-438
    • /
    • 2018
  • This study analyzed the fit-zone of the neck for females in their 60s. We considered the standard body types of females in their 60s and the four body types from the sixth Size Korea. The results of the study were as follows. We could not determine a pattern formula for the neck based on the changes in the body type of females in their 60s. However, the position of the lateral neck point generally showed a significant difference from that of females in their 20s. In the case of the shoulder angle, the point of the shoulder was angled slightly towards the back in all body types. It was also found that the curve of the neck circumference for both the collar and the bodice should have been smoother than what was shown on the 3D shape. The larger the height difference between the point of the back of the neck and the lateral neck point in the 3D shape, the smoother the design should be at the curve of the circumference at the front of the neck. A larger curvature in the front radius of the 3D shape increased the difference in the shape of the curve between the collar and the basic pattern of the bodice. Hence, a more careful design is required for these parts of the pattern. In addition, the more the front neck is bent, the smoother the circumference curve should be in the pattern design at the front of the neck and the collar.

3D Shape Reconstruction of Non-Lambertian Surface (Non-Lambertian면의 형상복원)

  • 김태은;이말례
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.1
    • /
    • pp.26-36
    • /
    • 1998
  • It is very important study field in computer vision 'How we obtain 3D information from 2D image'. For this purpose, we must know position of camera, direction of light source, and surface reflectance property before we take the image, which are intrinsic information of the object in the scene. Among them, surface reflectance property presents very important clues. Most previous researches assume that objects have only Lambertian reflectance, but many real world objects have Non-Lambertian reflectance property. In this paper the new method for analyzing the properties of surface reflectance and reconstructing the shape of object through estimation of reflectance parameters is proposed. We have interest in Non-Lambertian reflectance surface that has specular reflection and diffuse reflection which can be explained by Torrance-Sparrow model. Photometric matching method proposed in this paper is robust method because it match reference image and object image considering the neighbor brightness distribution. Also in this thesis, the neural network based shaped reconstruction method is proposed, which can be performed in the absence of reflectance information. When brightness obtained by each light is inputted, neural network is trained by surface normal and can determine the surface shape of object.

  • PDF

Planning of Multiple Tooth Implant Placement Using the Standardized Data in Teeth Size and Position (표준 치아 크기 및 배열 정보를 이용한 다중 치아 임플란트 식립계획 방안)

  • Park, Hyung-Wook;Park, Sang-Jin;Park, Hyungjun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.20 no.4
    • /
    • pp.348-356
    • /
    • 2015
  • It is important to devise methods for assisting dentists to consistently determine implant positions and directions and to accurately perform drilling tasks during dental implant surgery. In this paper, we propose a novel approach to tooth implant placement planning which deals with the determination of the positions and directions of multiple implant fixtures for a set of missing mandibular teeth and suggests the selection of the sizes and types of the implant fixtures. We combine Korean standard data in the sizes and positions of human teeth with the patient specific 3D models of mandibular jawbones, nerve curves, and neighboring teeth around the missing teeth in order to determine the positions and directions of the implant fixtures for the missing teeth. Using the geometric and spatial information of the jawbones, the teeth and the implant fixtures, we can construct the 3D models of surgical guide stents which are crucial to perform drilling tasks with ease and accuracy. Adopted in 3D simulation of dental implant placement, the approach can provide surgeon students with good educational contents. We also expect that, with further work, the approach can be used as a useful tool to plan for dental implant surgery.

Detection of N-Acetyltranylcypromine and Glucuronide of Phenyl-Hydroxylated N-Acetyltranlcypromine from Tranylcypromine-Dosed Rat Urine : Pharmacological Implications

  • Kang, Gun-Il;Choi, Hee-Kyung
    • Archives of Pharmacal Research
    • /
    • v.9 no.2
    • /
    • pp.99-110
    • /
    • 1986
  • In order to use for metabolic studies of tranylcypromine (TCP), TCP-phenyl-$d_{5}$ was synthesized via the intermediates, 3-benzoylpropionic acid-$d_{5}$ and trans-2-phenylcyclopropanecarboxylic acid-$d_{5}$ -TCP(0.22 mmole/kg) and its deuterated analog were administered s. c. to the rats and GC/MS analyses of the urines led to the detection of N-acetyltranylcypromine (ATCP) and glucuronide conjugate of phenyl-hydroxylated ATCP. MAO activities in rat brain were measured using serotonin as the substrate. In vitro $IC_{50}$ of ATCP was determined to be $10^{-3}M$. The inhibitions by ATCP were not dependent on the preincubation time and were reversed by washing sedimented mitochondrial pellets after the preincubation. In vivo MAO inhibitions at various times of 0.5, 1.5, 3, 6, 12, and 23 hr after the administration of 0.4 mmole/kg (i. p. ) of ATCP were found to be 0.13, 73, 90, 89, and 74 %, respectively. Similarly, the inhibition percents by 0.015 mmole/kg (i. p. ) of TCP were 94, 99, 95, 91, 71 and 49%. The results strongly suggest that deacetylated product of ATCP may account for its in vivo MAO inhibition. The relationship between the metabolism via phenyl-hydroxylation and the in vivo potency of TCP was examined by QSAR study and it was found that groupings discriminating between the compounds with p-substituents and those without them only ensure high correlations, suggesting that ring-hydroxylation which occurs at the para position in most of the compounds is a determining factor to the potency of TCP.

  • PDF

A Study on the Performance Variation of a Three-Dimensional Hydrofoil Using Jet Flow

  • Eom, Myeong-Jin;Paik, Kwang-Jun;Lee, Ju-Han;Kang, Shin-Min;Kim, Dong-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.24-37
    • /
    • 2021
  • As one of the development directions of high-performance ships to reduce greenhouse gas emissions, there is research on high-performance propellers. However, in the case of conventional screw propellers, as they have been studied for a long time, there is a limit to improving efficiency only by depending on the conventional design and analysis methods. In this study, we tried to solve the problems using the Coanda effect by spraying a jet on the surface of the hydrofoil. The Coanda hydrofoil consists of a tunnel and jet slit to make jet flow. The computation was performed for each tunnel and slit position, and the efficiency according to the geometry of the hydrofoil was analyzed. In addition, a study on the 3D geometry change was conducted to analyze the performance according to the span direction spraying range and hydrofoil shape. As the height of the slit and the diameter of the tip were lower, when the slit is located in the center of the hydrofoil, the lift force increased and the drag force decreased. The increase rate of lift-to-drag ratio was different according to the shape of the hydrofoil, and the efficiency of the spraying condition of 0.1S-0.5S, which had the least effect on the vortex at the tip of the blade, was high for all 3D hydrofoils. When the geometry of the slit was optimized, and also the shape and spray range of the hydrofoil in 3D was considered, the efficiency of the jet sprayed hydrofoil was increased.

A Study on the Design of Small SMT Platform for Education (교육용 소형 SMT 플랫폼 설계에 관한 연구)

  • Park, Se-Jun
    • Journal of Platform Technology
    • /
    • v.8 no.1
    • /
    • pp.24-32
    • /
    • 2020
  • This paper designed and manufactured a chip mounter based on 3D printer technology that can be used for educational research or sample production to disseminate chip mounter, a core technology of SMT line. A stepper motor with open loop control is used for low cost drive design. The shortcomings of the motor's vibration and disassembly caused by the use of the step motor were compensated by the Micro-Step control method. In the chip mounter experiment, the gerber file was generated on the small chip mounter, printed at the actual size, and the solder cream was printed on the HASL-treated PCB in the same manner as the sample board fabrication. As a result of the experiment, unlike the 2012 micro components, parts such as SOIC and TQFP that require correction are twice as long as the component mounting time, but it can be confirmed that they are mounted relatively accurately. In addition, as a result of repeatedly measuring the error of the initial position 10 times, it was confirmed that a relatively small error of about 0.110mm occurs.

  • PDF