• Title/Summary/Keyword: 3-D dose distribution

Search Result 188, Processing Time 0.026 seconds

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

Useful evaluation of 3D target location correction by using Xsight spine tracking system in CyberKnife (사이버나이프에서 Xsight spine tracking system을 이용한 3D 표적위치보정의 유용성 평가)

  • Jeong, Young-Joon;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.1
    • /
    • pp.331-339
    • /
    • 2015
  • The purpose of this study is to evaluate utility of rotating adjustment using Xsight spine tracking system in 3D DOF location adjusting method, to minimize error between 6D DOF and 3D DOF in fiducial tracking system. In this study, the result of 6D DOF target location error is $0.124{\pm}0.058mm$, using fiducial inside tumor 3D DOF $0.673{\pm}0.142mm$, outside tumor $1.126{\pm}0.253mm$, apply with Xsight spine tracking system 3D DOF $0.542{\pm}0.103mm$. As the experiment shows, it was demonstrated that rotating adjustment through Xsight spine tracking system is valuable in case of treatment in 3D DOF location error that makes increasing accuracy and dose distribution each approximately 48% and 3%. In accordance with result of this study is useful rotation.

USEFULNESS OF SIMPLE SHIELDING TECHNIQUE USING MULTILEAF COLLIMATOR IN BREAST RADIATION THERAPY

  • Lee, Kyu Chan;Lee, Seok Ho;Lee, Seung Heon;Sung, Kihoon;Ahn, So Hyun;Choi, Jinho;Dong, Kap Sang;Kim, Hyo Jin;Chun, Yong Seon;Park, Heung Kyu
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.4
    • /
    • pp.168-175
    • /
    • 2014
  • This study was designed to assess whether the conventional tangential technique, using a multileaf collimator (MLC), allows a reduced dose to the organs at risk (OAR) in breast radiation therapy. A total of forty right and left 20 for each breast cancer patients that underwent radiation therapy after breast conserving surgery were included in this study. For each patient, the planning target volume (PTV) and OAR (heart, left anterior descending artery (LAD), liver and lung) were defined and dose distribution were produced for conventional tangential beams using 6 MV photons. The treatment plans were made using the following two techniques for all patients. For the first plan (P1), MLC was designed to shield as much of OAR as possible without compromising the coverage of PTV. In the second plan (P2), the treatment plan was created without using MLC. Dose-volume histograms for OARs were calculated for all plans. For left breast cancer, the percentage of maximum dose ($D_{max%}$) and mean dose ($D_{mean%}$) of OARs (heart and LAD) were calculated, and for right breast cancer, the percentage of the mean dose ($D_{mean%}$) of the liver was calculated. The $D_{mean%}$ of the lung was calculated in all patients. The mean values of $D_{max%}$ of the heart ($86.9{\pm}19.5%$ range, 35.1-100.6%) in P1 were significantly lower than in P2 ($98.3{\pm}3.4%$ range, 91.7-105.2%) (p=0.001). The mean values of $D_{max%}$ of LAD ($78.4{\pm}22.5%$ range, 26.5-99.7%) in P1 was significantly lower than in P2 ($93.3{\pm}8.1%$ range, 67.9-102.1%) (p<0.001). In P1, the mean values of $D_{mean%}$ of the liver ($4.8{\pm}2.0%$) were significantly lower than in P2 ($6.2{\pm}2.5%$) (p<0.001). The mean values of $D_{mean%}$ of the lung were significantly lower in P1 ($9.3{\pm}2.3%$) than in P2 ($9.7{\pm}2.4%$) (p<0.001). P1, by using MLC, allows a significantly reduced dose to OAR compared with P2. We can suggest that it is reasonable to routinely use MLC in the conventional tangential technique for breast radiation therapy considering the primary tumor location.

A Study on Prospective Plan Comparison using DVH-index in Tomotherapy Planning (토모 테라피 치료 시 선량 체적 히스토그램 표지자를 이용한 치료계획 비교에 관한 연구)

  • Kim, Joo-Ho;Cho, Jeong-Hee;Lee, Sang-Kyoo;Jeon, Byeong-Chul;Yoon, Jong-Won;Kim, Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.113-122
    • /
    • 2007
  • Purpose: We proposed the method using dose-volume Histogram index to compare prospective plan trials in tomotherapy planning optimization. Materials and Methods: For 3 patients in cranial region, thorax and abdominal region, we acquired computed tomography images with PQ 5000 in each case. Then we delineated target structure and normal organ contour with pinnacle Ver 7.6c, after transferred each data to tomotherapy planning system (hi-art system Ver 2.0), we optimized 3 plan trials in each case that used differ from beam width, pitch, importance. We analyzed 3 plan trials in each region with isodose distribution, dose-volume histogram and dose statistics. Also we verified 3 plan trials with specialized DVH-indexes that is dose homogeneity index in target organ, conformity index around target structure and dose gradient index in non-target structures. Results: We compared with the similarity of results that the one is decide the best plan trial using isodose distribution, dose volume histogram and dose statistics, and the another is using DVH-indexes. They all decided the same plan trial to better result in each case. Conclusion: In some of case, it was appeared a little difference of results that used to DVH-index for comparison of plan trial in tomotherapy by special goal in it. But because DVH-index represented both dose distribution in target structure and high dose risk about normal tissue, it will be reasonable method for comparison of many plan trials before the tomotherapy treatments.

  • PDF

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

A Study of Al(III) Hydrolysis Species Characterization under Various Coagulation Condition (응집 pH와 응집제 종류에 따른 Al(III)가수분해종 특성변화에 대한 연구)

  • Song, Yu-Kyung;Jung, Chul-Woo;Sohn, In-Shik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.5
    • /
    • pp.958-967
    • /
    • 2006
  • The overall objective of this research was to find out the role of rapid mixing conditions in the species of hydrolyzed Al(III) formed by Al(III) coagulants and to evaluate the distribution of hydrolyzed Al(III) species by coagulant dose and coagulation pH. When an Al(III) salt was added to water, monomers, polymers and solid precipitates may form. Different Al(III) coagulants (alum and PSOM) show to have different Al(III) species distribution over a rapid mixing condition. During the rapid mixing period, for alum, formation of dissolved AI(III) (monomer and polymer) increases, but for PSOM, precipitates of $Al(OH)_{3(S)}$ increases rapidly. During the rapid mixing period, for high coagulant dose, Al-ferron reaction increases rapidly. The kinetic constants, Ka and Kb, derived from AI-ferron reaction. The kinetic constants followed very well the defined tendencies for coagulation condition. For pure water, when the rapid mixing time increased, the kinetic constants, Ka and Kb showed lower values. Also, for raw water, when the rapid mixing time increased, the kinetic constants, Ka and Kb showed lower values. At A/D(Adsorption and Destabilization) and sweep condition, both $Al(OH)_{3(S)}$ and dissolved Al(III) (monomer and polymer) exist, concurrent reactions by both mechanism appear to cause simultaneous precipitation.

Evaluation of accuracy in the ExacTrac 6D image induced radiotherapy using CBCT (CBCT을 이용한 ExacTrac 6D 영상유도방사선치료법의 정확도 평가)

  • Park, Ho Chun;Kim, Hyo Jung;Kim, Jong Deok;Ji, Dong Hwa;Song, Ju Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.109-121
    • /
    • 2016
  • To verify the accuracy of the image guided radiotherapy using ExacTrac 6D couch, the error values in six directions are randomly assigned and corrected and then the corrected values were compared with CBCT image to check the accurateness of ExacTrac. The therapy coordination values in the Rando head Phantom were moved in the directions of X, Y and Z as the translation group and they were moved in the directions of pitch, roll and yaw as the rotation group. The corrected values were moved in 6 directions with the combined and mutual reactions. The Z corrected value ranges from 1mm to 23mm. In the analysis of errors between CBCT image of the phantom which is corrected with therapy coordinate and 3D/3D matching error value, the rotation group showed higher error value than the translation group. In the distribution of dose for the error value of the therapy coordinate corrected with CBCT, the restricted value of dosage for the normal organs in two groups meet the prescription dose. In terms of PHI and PCI values which are the dose homogeneity of the cancerous tissue, the rotation group showed a little higher in the low dose distribution range. This study is designed to verify the accuracy of ExacTrac 6D couch using CBCT. It showed that in terms of the error value in the simple movement, it showed the comparatively accurate correction capability but in the movement when the angle is put in the couch, it showed the inaccurate correction values. So, if the body of the patient is likely to have a lot of changes in the direction of rotation or there is a lot of errors in the pitch, roll and yaw in ExacTrac correction, it is better to conduct the CBCT guided image to correct the therapy coordinate in order to minimize any side effects.

  • PDF

The Dosimetric Data of 10 MV Linear Accelerator Photon Beam for Total Body Irradiation (전신 방사선조사를 위한 10MV 선형가속기의 선량측정)

  • Ahn Sung Ja;Kang Wee-Saing;Park Seung Jin;Nam Taek Keun;Chung Woong Ki;Nah Byung Sik
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1994
  • Purpose : This study was to obtain the basic dosimetric data using the 10 MV X-ray for the total body irradiation. Materials and Methods : A linear accelerator photon beam is planned to be used as a radiation source for total body irradiation (TBI) in Chonnam University Hospital. The planned distance from the target to the midplane of a patient is 360cm and the maximum geometric field size is 144cm x 144cm. Polystyrene phantom sized $30{\times}30{\times}30.2cm^3$ and consisted of several sheets with various thickness, and a parallel plate ionization chamber were used to measure surface dose and percent depth dose (PDD) at 345cm SSD, and dose profiles. To evaluate whether a beam modifier is necessary for TBI, dosimetry in build up region was made first with no modifier and next with an 1cm thick acryl plate 20cm far from the polystyrene phantom surface. For a fixed sourec-chamber distance, output factors were measured for various depth. Results : As any beam modifier was not on the way of radiation of 10MV X-ray, the $d_{max}$ and surface dose was 1.8cm and $61\%$, respectively, for 345cm SSD. When an 1cm thick acryl plate was put 20cm far from polystyrene phantom for the SSD, the $d_{max}$ and surface dose were 0.8cm and $94\%$, respectively. With acryl as a beam spoiler, the PDD at 10cm depth was $78.4\%$ and exit dose was a little higher than expected dose at interface of exit surface. For two-opposing fields for a 30cm phantom thick phantom, the surface dose and maximum dose relative to mid-depth dose in our experiments were $102.5\%$ and $106.3\%$, respectively. The off-axis distance of that point of $95\%$ of beam axis dose were 70cm on principal axis and 80cm on diagonal axis. Conclusion: 1. To increase surface dose for TBI by 10MV X-ray at 360cm SAD, 1cm thick acrylic spoiler was sufficient when distance from phantom surface to spoiler was 20cm. 2. At 345cm SSD, 10MV X-ray beam of full field produced a satisfiable dose uniformity for TBI within $7\%$ in the phantom of 30cm thickness by two-opposing irradiation technique. 3. The uniform dose distribution region was 67cm on principal axis of the beam and 80cm on diagonal axis from beam axis. 4. The output factors at mid-point of various thickness revealed linear relation with depth, and it could be applicable to practical TBI.

  • PDF

Impact of Adaptive Radiotherapy on Locally Advanced Head and Neck Cancer - A Dosimetric and Volumetric Study

  • Dewan, Abhinav;Sharma, SK;Dewan, AK.;Srivastava, Himanshu;Rawat, Sheh;Kakria, Anjali;Mishra, Maninder;Suresh, T;Mehrotra, Krati
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.985-992
    • /
    • 2016
  • Objective of the study is to evaluate volumetric and dosimetric alterations taking place during radiotherapy for locally advanced head and neck cancer (LAHNC) and to assess benefit of replanning in them. Materials and Methods: Thirty patients with LAHNC fulfilling the inclusion and exclusion criteria were enrolled in a prospective study. Planning scans were acquired both pre-treatment and after 20 fractions (mid-course) of radiotherapy. Single plan (OPLAN) based on initial CT scan was generated and executed for entire treatment course. Beam configuration of OPLAN was applied to anatomy of interim scan and a hybrid plan (HPLAN30) was generated. Adaptive replanning (RPLAN30) for remaining fractions was done and dose distribution with and without replanning compared for remaining fractions. Results: Substantial shrinkage of target volume (TV) and parotids after 4 weeks of radiotherapy was reported (p<0.05). No significant difference between planned and delivered doses was seen for remaining fractions. Hybrid plans showed increase in delivered dose to spinal cord and parotids for remaining fractions. Interim replanning improved homogeneity of treatment plan and significantly reduced doses to cord (Dmax, D2% and D1%) and ipsilateral parotid (D33%, D50% and D66%) (p<0.05). Conclusions: Use of one or two mid-treatment CT scans and replanning provides greater normal tissue sparing along with improved TV coverage.