• Title/Summary/Keyword: 3-D CT image

Search Result 432, Processing Time 0.031 seconds

Analysis of the image composition speed of RT and TPSM algorithms (RT과 TPSM 알고리즘의 영상구성 속도 분석)

  • Jin-Seob Shin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.6
    • /
    • pp.139-143
    • /
    • 2023
  • In this paper, compared to the RT algorithm that constitutes CT images, the TPSM algorithm available in the conical CB-CT system was applied to enable 3D CT image configuration faster than the existing RT, and the image speeds of the two algorithms were compared and analyzed. To this end, the TPSM algorithm available in the conical CB-CT system was applied to enable real-time processing in 3D CT image composition. As a result of the experiment, it was found that the cross-sectional image constructed using TPSM decreases the quality of the image slightly by empty pixels as the distance from the center point increases, but in the case of TPSM rotation-based methods, the image composition speed is far superior to that of the RT algorithm.

Comparison of 64 Channel 3 Dimensional Volume CT with Conventional 3D CT in the Diagnosis and Treatment of Facial Bone Fractures (얼굴뼈 골절의 진단과 치료에 64채널 3D VCT와 Conventional 3D CT의 비교)

  • Jung, Jong Myung;Kim, Jong Whan;Hong, In Pyo;Choi, Chi Hoon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.605-610
    • /
    • 2007
  • Purpose: Facial trauma is increasing along with increasing popularity in sports, and increasing exposure to crimes or traffic accidents. Compared to the 3D CT of 1990s, the latest CT has made significant improvement thus resulting in higher accuracy of diagnosis. The objective of this study is to compare 64 channel 3 dimensional volume CT(3D VCT) with conventional 3D CT in the diagnosis and treatment of facial bone fractures. Methods: 45 patients with facial trauma were examined by 3D VCT from Jan. 2006 to Feb. 2007. 64 channel 3D VCT which consists of 64 detectors produce axial images of 0.625 mm slice and it scans 175 mm per second. These images are transformed into 3 dimensional image using software Rapidia 2.8. The axial image is reconstructed into 3 dimensional image by volume rendering method. The image is also reconstructed into coronal or sagittal image by multiplanar reformatting method. Results: Contrasting to the previous 3D CT which formulates 3D images by taking axial images of 1-2 mm, 64 channel 3D VCT takes 0.625 mm thin axial images to obtain full images without definite step ladder appearance. 64 channel 3D VCT is effective in diagnosis of thin linear bone fracture, depth and degree of fracture deviation. Conclusion: In its expense and speed, 3D VCT is superior to conventional 3D CT. Owing to its ability to reconstruct full images regardless of the direction using 2 times higher resolution power and 4 times higher speed of the previous 3D CT, 3D VCT allows for accurate evaluation of the exact site and deviation of fine fractures.

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull (전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교)

  • Kang Bok-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

A Study on Automated 3-D Reconstruction Based on 2-D CT Image of Lumber Spine (요추의 2차원 CT 영상을 이용한 3차원 형상모델링의 자동화 연구)

  • 김성민;김성재;서성영;탁계례
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.5
    • /
    • pp.581-586
    • /
    • 1999
  • 척추의 생체역학적 해석을 위한 유한요소기법을 이용한 컴퓨터 시뮬레이션은 척추의 손상에 대한 발생원인과 기전을 이해하고 치료의 효과를 예측하는 유용한 수단으로 기대되고 있다. 본 논문에서는 요추의 2차원 CT 영상을 이용하여 유한요소해석을 위한 척추의 3차원 모델링에 소비되는 많은 시간을 줄일 수 있도록 3차원 형상모델을 CT 형상 데이터와 형상변수를 이용, 각각 구현하는 과정을 자동화하여 이를 비교하였다.

  • PDF

Three-Dimensional Image Registration using a Locally Weighted-3D Distance Map (지역적 가중치 거리맵을 이용한 3차원 영상 정합)

  • Lee, Ho;Hong, Helen;Shin, Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.31 no.7
    • /
    • pp.939-948
    • /
    • 2004
  • In this paper. we Propose a robust and fast image registration technique for motion correction in brain CT-CT angiography obtained from same patient to be taken at different time. First, the feature points of two images are respectively extracted by 3D edge detection technique, and they are converted to locally weighted 3D distance map in reference image. Second, we search the optimal location whore the cross-correlation of two edges is maximized while floating image is transformed rigidly to reference image. This optimal location is determined when the maximum value of cross-correlation does't change any more and iterates over constant number. Finally, two images are registered at optimal location by transforming floating image. In the experiment, we evaluate an accuracy and robustness using artificial image and give a visual inspection using clinical brain CT-CT angiography dataset. Our proposed method shows that two images can be registered at optimal location without converging at local maximum location robustly and rapidly by using locally weighted 3D distance map, even though we use a few number of feature points in those images.

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

초음파 영상 진단장치

  • 이민화
    • 전기의세계
    • /
    • v.38 no.8
    • /
    • pp.9-18
    • /
    • 1989
  • 초음파 CT는 시기적으로 가장 빨리 X-ray CT와 함께 연구되어 왔으나 인체내의 투과성, 난반사, 긴파장등에 의해 실용화가 아직은 요원하다. 초음파 CT는 크게 Time of flight (TOF)CT, Attenuation CT, Reflection CT, Diffraction CT등으로 나눌수 있다. 초기에는 TOF CT, Attenuation CT의 연구가 주로 이루어 졌으나 투과의 문제로 인하여 실제로는 유방의 진단에 국한되고 있다. Reflection CT는 초음파의 특성상 실용화가 가장 쉬우나 Transducer 크기등의 문제로 연구가 지연되고 있다. Diffraction CT는 모든 초음파 CT의 특성을 갖고 있으며 현재에 실용화는 요원한 실정이다. KAIST에서는 TOF CT와 Reflection CT의 특징을 결합한 초음파 CT를 연구 발표한 바 있다. 3-D Image은 지금까지의 초음파진단장치에서 표시하는 2-D Image가 갖고 있는 제반의 문제들을 극복하기 위해 현재 KAIST에서 활발히 연구가 진행중에 있다.

  • PDF

3D CT Image Processing for 3D Printed Auricular Reconstruction of Unilateral Microtia Patient

  • Roh, Tae Suk;Yun, In Sik
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.2
    • /
    • pp.80-82
    • /
    • 2014
  • Purpose Microtia is congenital anomaly of external ear and the reconstruction method for the external ear of microtia patient was based on autogenous costal cartilage framework. The application of 3D printing technique in medical science has made more possibility of human tissue restoration, and we tried to apply this technique in auricular reconstruction field. Materials and Methods As for unilateral microtia patient, the contralateral side ear is normal and reconstructive surgeon tried to mimic it for reconstruction of affected ear. So, we obtained facial CT scan of microtia patient and made mirror image of normal side ear. Moreover, to make the 3D scaffold based on the mirror image of normal ear and to apply this scaffold for the auricular reconstruction surgery, we included auriculocephalic sulcus and anterior fixation part. Results We could successfully obtain mirror image of normal ear, auriculocephalic sulcus and anterior fixation part for 3D scaffold printing. Conclusions Using this CT image processing and 3D printing technique, we will be able to make the scaffold for auricular reconstruction of unilateral microtia patient, and perform auricular reconstruction in near future.