• Title/Summary/Keyword: 3 phase

Search Result 20,969, Processing Time 0.048 seconds

Effect of Light on Developmental Changes and Activities of Microbody in the Cotyledons of Radish Seedlings (발아중 빛에 의한 무 유식물의 자엽 Microbody의 활성 변화)

  • 박민철
    • Journal of Plant Biology
    • /
    • v.29 no.4
    • /
    • pp.243-254
    • /
    • 1986
  • The enzyme patterns and the food storage changes in radish (Raphanus sativus L. cv. Taewang) cotyledons during seedling development were studied. The radish seeds were germinated for 8 days at $25^{\circ}C$ under light (7, 000 lux) or dark condition. The lipid and protein contents per seed were 4.3 mg and 2.85 mg respectively. In 8-day-old light-grown seedling, the lipid and protein contents per cotyledon pair were 1.5 mg and 2.08 mg; in 8-day-old dark-grown seedling, they were 0.8 mg and 1.24 mg respectively. The heterotrophic phase of seedlings continued for 3 days after sowing and followed by autotrophic phase (3~6 day) and senescence phase (6~8 day). The food storage function decreased in response to time course. During heterotrophic phase, the activities of glyoxysomal enzymes (malate synthetase, isocitrate lyase, and catalase) were high at 2~3 day. Those patterns were somewhat more prominent in darkness. During the autotrophic phase, the activities of peroxysomal enzymes (glycolate oxidase and catalase) increased at 4~5 day.

  • PDF

Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter (단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선)

  • 최세완;양승욱
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.21-26
    • /
    • 2001
  • This paper proposes a new double-connected 3-phase voltage source inverter with improved output voltage waveform. An auxiliary single-phase inverter injects a ripple voltage into the double-connected inverter to converter 12-step operation to 36-step operation. The KVA rating of the output phase-shifting transformer is reduced by employing a harmonic canceling reactor. The whole rectifier-inverter system including the proposed technique is introduced, and the experimental results are provided.

  • PDF

3-Phase Pseudo-Random Carrier Modulation Technique for the Acoustic Noise Reduction of the 3-Phase Multi-Level Inverter Based Motor (3상 멀티 레벨 인버터 구동 유도 전동기의 소음저감을 위한 3상 준 랜덤 캐리어 변조기법)

  • Park, J.K.;Kim, J.N.;Jung, Y.G.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.742-745
    • /
    • 2005
  • This paper describes a simple pseudo-random carrier modulation technique for the acoustic noise reduction of the three phase multi-level inverter based motor drives. The proposed method generates a new pseudo-random carrier by randomly synthesizing a carrier with fixed frequency and a carrier with opposition phase. To confirm the validity of the proposed method, a 130v three-phase multi-level inverter was Implemented and tested. The experimental results show that the output line voltage and acoustic noise harmonics spectra of an inverter have broadening effect of harmonics, as only simple synthesis of fixed frequency carries.

  • PDF

A Study on the PR shaped SQAM error rate with carrier phase error (PR Shape된 SQAM의 오율에 반송파위상오차가 미치는 영향에 대한 연구)

  • 박용우;이형재
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.9 no.1
    • /
    • pp.11-17
    • /
    • 1984
  • A study is presented showing the effect of carrier phase error on the error-rate of a (Class I, II, IV)PR shaped SQAM digital communication system. A simple upper bound on the probabilty of error as a function of phase error is derived and compared to one another. The results show that the three system can be used appropriately if carrier phase error is less than 3$^{\circ}$. However, if phase error is larger than 3, the PR class I is the best choice.

  • PDF

Multi-level Inverter Using 3-Phase isolated Transformers (3상 절연형 변압기를 이용한 다중레벨)

  • Lee, Hwa-Chun;Song, Sung-Gun;Park, Sung-Jun;Kim, Kwang-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1134-1135
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

  • PDF

Removal Efficiencies Estimation of Air Pollutants at Wet Scrubber Using Activated Carbon (활성탄 사용에 따른 습식세정시설에서의 대기오염물질 제거효율 평가)

  • 신찬기;권명희;전종주;신대윤
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.2
    • /
    • pp.87-93
    • /
    • 2003
  • This study carried out to recommend adaptable technologies and countermeasures for performance improvement of Wet Scrubber(WS) in industrial waste incinerator. When not using the Activated Carbon(AC), the removal efficiency of dust and HCl is 73%, 92%. And particulate phase and gaseous phase dioxins removal efficiency was evaluated up to 31% and 12%. In this case, dioxins enrichment was not revealed in WS. When using the AC mixing with scrubbing water, the case of 1,000ppm, removal efficiency of particulate phase dioxins was about 51%, and gaseous phase dioxins was about 96%. The case of 2,000ppm, removal efficiency of particulate phase dioxins was about 55%, and gaseous phase dioxins was about 97%. And the case of 3,500ppm, the removal efficiency of particulate phase dioxins was about 35%, and gaseous phase dioxins was about 96% respectively. By this study, using the AC was more useful to remove the gaseous phase dioxins, and needed to use proper concentration of the AC, that in case of 3,500ppm, the particulate phase dioxins removal efficiency was more lower than other cases.

A Comparative Study on Power Generation Characteristics of Permanent Magnet Synchronous Generators for Green Ship

  • Kato, Shinji;Cho, Gyeong-Rae;Michihira, Masakazu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.3
    • /
    • pp.378-386
    • /
    • 2012
  • For reduction of the amount of CO2 emitted from ships, power generation characteristics of two power generation systems consisting of a high-efficiency permanent magnet synchronous generator and diode bridge rictifiers are discussed in this paper. One of the discussed systems has three-phase stator windings, and the other has two sets of three-phase (six-phase) stator windings to reduce pulsation in the electromagnetic torque and DC current. Experimental results reveal that the power generation efficiency of the system having six-phase stator windings is higher than that of the system having three-phase stator windings for a light load. The maximum power generation efficiency of the system having six-phase stator windings is almost the same as that of the system having three-phase stator windings. For the electromagnetic torque of the system having six-phase stator windings, the width of pulsation is about one-fifth compared to the system having three-phase stator windings.

Static VAR Compensator-Based Voltage Regulation for Variable-Speed Prime Mover Coupled Single- Phase Self-Excited Induction Generator

  • Ahmed, Tarek;Noro, Osamu;Sato, Shinji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.185-196
    • /
    • 2003
  • In this paper, the single-phase static VAR compensator (SVC) is applied to regulate and stabilize the generated terminal voltage of the single-phase self-excited induction generator (single-phase SEIG) driven by a variable-speed prime mover (VSPM) under the conditions of the independent inductive load variations and the prime mover speed changes The conventional fixed gain PI controller-based feedback control scheme is employed to adjust the equivalent capacitance of the single-phase SVC composed of the fixed excitation capacitor FC in parallel with the thyristor switched capacitor TSC and the thyristor controlled reactor TCR The feedback closed-loop terminal voltage responses in the single-phase SEIG coupled by a VSPM with different inductive passive load disturbances using the single-phase SVC with the PI controller are considered and discussed herem. A VSPM coupled the single-phase SEIG prototype setup is established. Its experimental results are illustrated as compared with its simulation ones and give good agreements with the digital simulation results for the single-phase SEIG driven by a VSPM, which is based on the SVC voltage regulation feedback control scheme.

A Study on the Comparision of Performance between Three-phase Full-wave and Single-phase Full-wave X-ray Generators (삼상(三相)12펄스 전파정류장치(全波整流裝置)와 단상(單相) 전파정류장치(全波整流裝置)의 성능(性能) 비교(比較))

  • Kim, Young-Ill;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.81-86
    • /
    • 1980
  • To compare three-phase 12-pulse full-wave X-ray generators with single-phase full-wave X-ray generators on their performance of outputs, authors studied the generating X-ray by means of exposure dose and radiographic density. The results were as follows; 1. The exposure doses of three-phase full-wave X-ray generators showed a 30%-60% increase as compared against of single-phase full-wave generators. 2. The transmitted doses of three-phase full-wave generators were more increased than single-phase full-wave X-ray generators. 3. To obtain the same density, 60kVp in three-phase full-wave generators were equivalent to $60{\sim}65kVp$ in single-phase full-wave generators, and 100kVp in those generators were equivalent to $100{\sim}125kVp$ in these generators.

  • PDF

A Low COST SOFT-SWITCHED AC-TO-TC CONVERTER

  • 최주엽;목형수;김택용
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.135-140
    • /
    • 1997
  • A highly efficient single-phase/three-phase compatible ac-to-dc converter is proposed and analyzed, which includes three identical single-phase both soft-switched dc-to-dc converter with boost converter as a pre-regulator for input power factor correction (PFC). The proposed converter structure provides a cost reduction and easy implementation of compatibility between single-phase 220V and three-phase 220V/380V with their inputs in delta or wye connections.

  • PDF