• 제목/요약/키워드: 3 mm Wave Length

검색결과 98건 처리시간 0.028초

연속파 파이버 레이저를 이용한 SS400의 절단 특성에 관한 연구 (A Study on SS400 Cutting Characteristics using Continuous Wave Fiber Laser)

  • 오용석;이가람;박은경;유영태
    • 한국생산제조학회지
    • /
    • 제21권4호
    • /
    • pp.644-650
    • /
    • 2012
  • This paper show the 2kW fiber laser cutting properties of SS400. The study was comparison of traditional 4kW $CO_2$ Laser cutting and 2kW Fiber laser cutting characteristics for the application of Industrial 2D Laser Cutting Machine. The laser used in this investigation was an IPG YLU-2000 multi-mode Ytterbium Fiber machine with a maximum power of 2000W and a wave length of 1070 nm. The laser was used in its Continuous Wave (CW) mode with an approximately top hat beam intensity distribution. Fiber laser high quality cuts at a large range of speeds (ranging from 2000 to 3800 mm/min) which has been obtained for the 2.3mm Sheet of SS400. 2kW power Fiber laser cut was able to max. 20mm sheets of SS400 (speed range from 650 to 850 mm/min). Fiber laser cutting used in conventional hole nozzle could cut 12mm SS400 but used in special dual cutting nozzle could cut 20mm SS400.

Plasma Jet의 동축평행자계에 의한 영향에 관한 연구 2 (A Study on the Influence Coaxial Parallel Magnetic Field upon Plasma Jet (II))

  • 전춘생
    • 전기의세계
    • /
    • 제22권5호
    • /
    • pp.19-32
    • /
    • 1973
  • This paper treats with some of plasma jet behaviors under magnetic field for the purpose of controlling important characteristics of plasma jet in the practices of material manufacturings. Under the existence and non-existence of magnetic field, the pressure distribution, flame length, stability and noise of plasma jet are comparatively evaluated in respect of such parameters as are current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle. The results are as follows: 1) the pressure, the length and the noise of plasma jet rise gradually with the increase of are current, and have high values under identical arc current as the diameter of nozzle increases, but reverse phenomenon tends to appear in the noise. 2) The pressure, the flame length and the noise increase with the increased quantity of argon flow, and the rising slope of noise is particularly steep. Under magnetic field, the quantity of argon flow in respect of flame length has the critical value of 80(cfh). 3) The pressure and length of flame decrease with small gradient value as the length of gap increases, but the noise tends to grow according to the increase of nozzle diameter. 4) The pressure and the length of jet flame decrease inversly with the increase of magnetic flux density, which have one critical value in the 100 amps of arc current and two values in 50 amps. The pressure of jet flame can be below atomospher pressure in strong magnetic field. 5) "The constriction length of nozzle has respectively the critical value of 6(mm) for pressure and 23(mm) for the length of flame. 6) Fluctuations in the wave form of voltage become greater with the increase of argon flow and magnetic flux density, but tends to decrease as arc current increases, having the frequency range of 3-8KHz. The wave form of noise changes almost in parallel with that of voltage and its changing value increases with argon flow, arc current and magnetic flux density, having the freuqency range of 6-8KHz. The fluctuation of jet presurre is reduced with the increase of argon flow and magnetic flux density and grows with arc current.rent.

  • PDF

개방 근첨 치아의 근관 충전방법에 따른 치근단 폐쇄효과에 관한 연구 (THE SEALING ABILITY OF OBTURATION TECHNIQUES IN OPEN APEX)

  • 소현;최호영;최경규;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제25권3호
    • /
    • pp.435-445
    • /
    • 2000
  • The purpose of this study was to compare the leakage of four different obturation techniques in conjunction with immediate apical barrier of ${\beta}$-tricalcium phosphate(TCP) in teeth with open apex. Eighty single-rooted human premolar teeth were prepared and sectioned horizontally, so maximum diameter in apex was 4mm. Apical defects that were similar to open apex, were created with #1/2 round bur and SF104R bur. The apical foramen were opened to a size 80 file extended 3mm beyond the apex. The teeth were placed into the oasis block soaked saline to simulate periapical tissue often associated with pulpless teeth and received apical barriers consisting of TCP followed by obturation using lateral condensation technique, vertical condensation technique, continuous wave technique and thermoplasticized gutta-percha injection technique. Two unobturated teeth served as positive and negative controls. Teeth were immersed in resorcinol-formaldehyde resin for S days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were then sectioned horizontally at 1.5mm(level 1), 2.5mm(level 2) and 3.5mm(level 3) from the apex, and examined under a stereomicroscope at ${\times}40$ magnification. The photographs were taken at ${\times}40$ magnification of the filling in each level and scanned. The leakage length in tooth/resin interface was measured at each of the three levels. Each ratio of leakage was obtained by calculating the ratio of the leakage length of canal wall infiltrated with resin to the total length of the canal and was analyzed statistically(One-way ANOVA and Scheffe test). The result were as follows : 1. At the level 1, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there was statistically significant(p<0.05). 2. At the level 2, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), and the most leakage in the continuous wave technique group(group 3). There was statistically significant difference between the thermoplasticized gutta-percha injection technique group and the continuous wave technique group(p<0.05). 3. At the level 3, there was the least leakage in the thermoplasticized gutta-percha injection technique group(group 4), but there were no statistically significant differences between other groups(p>0.05). These results suggest that thermoplasticized gutta-percha injection technique which had 1mm apical gutta-percha matrix after the formation of TCP apical barrier, can demonstrate favorable apical sealing.

  • PDF

A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals

  • Yoo, Young-Sil;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • 제37권4호
    • /
    • pp.220-227
    • /
    • 2012
  • Objectives: The study was to compare the shaping ability of Reciproc (VDW) and WaveOne (Dentsply Maillefer) instruments compared with ProTaper, Profile and hand instrument during the preparation of simulated root canals. Materials and Methods: Five groups (n = 5) were established. Reciproc, WaveOne, ProTaper, Profile and K file (K-flexo file) were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a microscope and superimposed in 2 different layers. The amount of resin removed from both the inner and the outer sides of the canal was measured to the level of 10 mm from the apical tip, with a 1 mm increment. Results: The mean of resin removal from the inner canal wall was not different from the outer canal wall for Reciproc and WaveOne groups at apical third (1 - 3 mm level). There was no difference in the change of working length and maintenance of canal curvature. NiTi instruments are superior to stainless-steel K file in their shaping ability. Conclusions: Within the limitation of this present study, Reciproc and WaveOne instruments maintained the original canal curvature in curved canals better than ProTaper and Profile, which tend to transport towards the outer canal wall of the curve in the apical part of the canal.

식약처에서 허가된 집속형 ESWT 치료기의 음향 출력 분석 (Inspection on the acoustic output of the focused extracorporeal focused shock wave therapeutic devices approved by MFDS)

  • 최민주;전성중;권오빈;이민영;조진식;김한수;맹은호
    • 한국음향학회지
    • /
    • 제39권4호
    • /
    • pp.303-317
    • /
    • 2020
  • 체외충격파치료술(Extracorporeal Shock Wave Therapy, ESWT)은 보존적인 치료가 어려운 근골격계 난치성 통증 치료 뿐 아니라 심혈관계 질환까지 적용 분야가 확대되고 있는 혁신적인 치료술이다. 본 연구에서는 국내에서 사용되는 집속형 ESWT 치료기의 성능을 결정하는 충격파 음향 출력의 분포를 조사했다. 분석에 사용된 데이터는 식약처에 등록된 30개 기술 문서를 통해 수집했다. 조사 결과, ESWT 치료기 충격파의 집속 특성은, 초점 거리가 5 mm ~ 65 mm, 초점 폭이 3 mm ~ 30 mm, 초점 깊이가 4 mm ~ 108 mm 범위에서 변화하고 있다. 충격파의 최대 양압(P+)는 7 MPa ~ 280 MPa, 초점에서 에너지 밀도 Energy Flux Density(EFD)는 0.0035 mJ/㎟ ~ 35 mJ/㎟, 펄스당 에너지(E)는 0.737 mJ ~ 80.86 mJ로 매우 넓은 범위에서 분포하고 있다. P+ 및 EFD 상관성 분석에 포함된 모든 국내산 PE 방식 제품(5개) 및 1개의 EM 방식 국산 치료기는 P+ 및 EFD가 통상적인 범위를 크게 벗어나고 있으며, 예상되는 상관성을 따르지 않고 있어, 데이터의 신뢰성을 인정하기 어려운 상태이다. 음향 출력의 값에 신뢰성을 부여하기 어려운 경우, 식약처에서 인정하는 시험 검사 기관을 통해 사후 시험 검사 및 관리가 요구된다. 충격파 음향 출력에 대한 통과 기준이 치료기의 적응증에 대한 임상 시험 결과를 근거로 설정될 수 있도록 식약처의 규정 및 가이드라인 개선이 필요하다.

Development of Ultrasonic Wave Propagation Imaging System

  • Chia, Chen-Ciang;Lee, Jung-Ryul;Kim, Jong-Heon
    • 비파괴검사학회지
    • /
    • 제29권4호
    • /
    • pp.283-292
    • /
    • 2009
  • Laser-based ultrasonic sensing requires the probe with fixed fecal length, but this requirement is not essential in laser-based ultrasonic generation. Based on this fact, we designed a pulsed laser-based ultrasonic wave propagation imaging (UWPI) system with a tilting mirror system for rapid scanning of target, and an in-line band-pass filtering capable of ultrasoaic mode selection. 1D-temporal averaging, 2D-spatial averaging, and 3D-data structure building algorithms were developed far clearer results allowing fur higher damage detectability. The imaging results on a flat stainless steel plate were presented in movie and snapshot formats which showed the propagation of ultrasound visible as a concentric wavefield emerging from the location of an ultrasonic sensor. A hole in the plate with a diameter of 1 mm was indicated by the scattering wavefields. The results showed that this robust UWPI system is independent of focal length and reference data requirements.

Studies of MIMIC Power amplifier for millimeter-waves

  • Rhee, Eung-Ho;Yoon, Jin-seub;Cho, Seung-ki;Yoon, Jin-seub
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 ITC-CSCC -2
    • /
    • pp.1009-1012
    • /
    • 2000
  • In this paper, we have designed and fabricated power PHEMT’s with an unit gate width of 80$\mu\textrm{m}$ and 4 fingers, and MIMIC power amplifiers using the PHEMT’s as well. The PHEMT’s have a 0.2$\mu\textrm{m}$ gate length and source to drain spacing of 3$\mu\textrm{m}$. The characteristics of the fabricated PHEMT’s are 4.08dB of S$\sub$21/ gain at the 35GHz and 317mS/mm of gm, and 62GHz of f$\sub$T/ and 120GHz of f$\sub$max/. The designed and fabricated MIMIC’s power amplifiers with 6 PHEMT’s and MIN capacitors were fully passivated by 1000 Α of Si$_3$N$_4$ film for higher performance and surface protects. The chips were processed using the MINT processes, and size was 3.25 ${\times}$ 1.8$\textrm{mm}^2$. The fabricated MIMIC power amplifiers have RF characteristics such as 11.25dB of S$\sub$21/ gain, 11.37dB of input return-loss and 12.69dB of output return-loss at the 34.55GHz.

  • PDF

Simulated resin root canal에서 엔진 구동형 Ni-Ti 파일로 근관성형 후 Buchanan plugger의 근관 내 삽입깊이에 대한 비교 연구 (A STUDY OF INSERTION DEPTH OF BUCHANAN PLUGGER AFTER SHAPING USING NI-TI ROTARY FILES IN SIMULATED RESIN ROOT CANALS)

  • 박연식;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제31권2호
    • /
    • pp.125-132
    • /
    • 2006
  • 본 연구는 레진 블록에서 엔진구동형 Ni-Ti기구를 이용하여 근관성형 후 Buchanan plugger의 삽입 깊이에 대한 비교를 통해 임상적 상황에서 Ni-Ti 파일로 근관 성형 후 Continuous wave of condensation technique을 이용한 근관 충전시 적절한 크기의 Buchanan plugger 선택에 지침을 제공하기 위해 시행되었다. 만곡근관과 직선근관을 가진 레진 블록에서 ProTaper와 ProFile을 이용하여 근관 성형을 하였다. 성형 후 근관에 Buchanan plugger가 근관벽과 처음으로 접촉하는 부위까지 삽입한 후 그 상태에서 스캐너를 이용하여 이미지를 얻었다. 이미지 분석 프로그램을 이용해 근첨에서 plugger 첨부까지의 거리를 얻었다. 각 기구에 대한 plugger 삽입깊이에 대한 유의성을 검정하기 위해 one-way ANOVA를 시행하였고, 사후검정을 위해 Scheffe's test를 시행하였다. 본 연구의 결과 만곡되고 좁은 근관에서, ProTaper F2와 F3로 마무리 성형한 근관에서 F, FM크기의 plugger를 사용할 경우 Continuous wane of condensation technique으로 적절한 근관충전이 가능함을 시사하였다.

20GHz 이상 대역에서의 국내 고정 무선중계 시스템의 최적 경로길이 설계 (Design of Optimal Hop Length for Fixed Radio Relay Links above 20GHz in Korea)

  • 이형수;김혁제;신동근
    • 한국전자파학회논문지
    • /
    • 제7권3호
    • /
    • pp.263-271
    • /
    • 1996
  • 20GHz 이상 주파수대역은 아직까지 사용하고 있지 않는 넓은 대역의 전파자원이지만 대기에 의한 전파감쇠가 심해 중계거리에 제약을 받게 되므로 단거리통신에 사용되고 있다. 그러나 현재 국내에서는 20 GHz 이상의 주파수대역에서 어느정도의 거리에서 무선시스템의 선뢰도를보장할수있는지 연구된 적이 없는 실정이다. 본 논문은 20GHz 이상 대역에서 대가중의 전파특성을 분석하고 그 중 무선 경로 길이에 가장 많은 영향을 미치는 강우감쇠를 추정할 수 있는 계산식을 분석하였다. 그리고, 강우감쇠 계산에 가장 기본적인 요소인 강우강도를 국내 측후소에서 측정된 강우 자료를 이용하여 서울등 대 도시에서의 시간별 강우강도 데이터로 제시하고 이를 기 본 데이터로 하여 대도시에서의 무선 중계시스템의 최적 중계거리를 제시하였다.

  • PDF

마이크로파 특성에 따른 진행파형 전계흡수 변조기의 비선형 모델 (Novel Model for Nonlinearity of Traveling-Wave Electroabsorption Modulator according to Microwave Characteristics)

  • 윤영설;이정훈;최영완
    • 대한전자공학회논문지SD
    • /
    • 제40권8호
    • /
    • pp.580-587
    • /
    • 2003
  • 본 논문에서는 진행파형 전계흡수 변조기 (TW-EAM: traveling-wave electroabsorption modulator)의 선형성을 분석하기 위한 새로운 모델을 제시한다. TW-EAM은 소자의 길이, 마이크로파 손실 (microwave loss, ML), 그리고 임피던스 부정합에 의한 내부반사(internal reflection, IR) 등이 소자의 선형성에 영향을 미친다. 소자의 길이의 증가는 혼변조 왜곡 (intermodulation distortion, IMD)이 최소가 되는 전원전압의 크기를 감소시킨다. ML의 증가는 3차 혼변조 왜곡 (third-order IMD, IMD3)의 감소와 동시에 출력신호의 전력도 감소시킨다. IR은 입력주파수의 파장과 소자의 길이에 따라 각기 다른 IMD 특성을 나타낸다. ML 또는 IR에 의한 SFDR (spurious-free dynamic-range)의 변화는 거의 없었으며, TW-EAM의 IR을 이용하면 ML에 의한 신호 전력의 감쇄를 보상해 줄 수 있음도 알 수 있었다. 결과적으로 50 GHz 대역의 RF-광통신용 TW-EAM은 길이가 0.8 mm이고 출력단의 임피던스 부정합을 이용하면서 최소의 손실을 가지는 구조가 적당함을 알 수 있었다.