• Title/Summary/Keyword: 3 inch

Search Result 551, Processing Time 0.035 seconds

Experiment and Flow Analysis of the Flow Coefficient Cv of a 1 inch Ball Valve for a Thermal Power Plant (화력발전소용 1인치 볼 밸브 유량계수 Cv에 관한 유동해석 및 실험에 관한 연구)

  • Kang, Chang-Won;Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.109-115
    • /
    • 2019
  • The purpose of this study was to analyze and test the flow rate of a 1-inch ball valve used in a thermal power plant. To identify the flow-rate characteristics, numerical analysis was conducted and an experimental apparatus of the valve flow rate coefficient was used to compare the flow coefficient Cv values. To determine the internal pressure distribution, the sites of opening ball valves and flow fields were investigated. In particular, a smaller the valve opening resulted in a more complicated the flow field of the ball. The valve flow characteristic test showed that the Cv value and flow rate increased with increasing valve-opening rate and the secondary function was performed. The pressure drop increased as the valve opening rate decreased. In addition, the experimental results for the flow analysis are similar to the numerical analysis results.

Comparison of three different orthodontic wires for bonded lingual retainer fabrication

  • Baysal, Asli;Uysal, Tancan;Gul, Nisa;Alan, Melike Busra;Ramoglu, Sabri Ilhan
    • The korean journal of orthodontics
    • /
    • v.42 no.1
    • /
    • pp.39-46
    • /
    • 2012
  • Objective: We evaluated the detachment force, amount of deformation, fracture mode, and pull-out force of 3 different wires used for bonded lingual retainer fabrication. Methods: We tested 0.0215-inch five-stranded wire (PentaOne, Masel; group I), $0.016{\times}0.022$-inch dead-soft eight-braided wire (Bond-A-Braid, Reliance; group II), and 0.0195-inch dead-soft coaxial wire (Respond, Ormco; group III). To test detachment force, deformation, and fracture mode, we embedded 94 lower incisor teeth in acrylic blocks in pairs. Retainer wires were bonded to the teeth and vertically directed force was applied to the wire. To test pull-out force, wires were embedded in composite that was placed in a hole at the center of an acrylic block. Tensile force was applied along the long axis of the wire. Results: Detachment force and mode of fracture were not different between groups. Deformation was significantly higher in groups II and III than in group I (p < 0.001). Mean pull-out force was significantly higher for group I compared to groups II and III (p < 0.001). Conclusions: Detachment force and fracture mode were similar for all wires, but greater deformations were seen in dead-soft wires. Wire pull-out force was significantly higher for five-stranded coaxial wire than for the other wires tested. Five-stranded coaxial wires are suggested for use in bonded lingual retainers.

A Study of Transient Liquid Phase Bonding with Ni-foam/Sn-3.0Ag-0.5Cu Composite Solder for EV Power Module Package Application (Ni-foam/Sn-3.0Ag-0.5Cu 복합 솔더 소재를 이용한 EV 파워 모듈 패키지용 천이 액상 확산 접합 연구)

  • Young-Jin Seo;Min-Haeng Heo;Jeong-Won Yoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.30 no.1
    • /
    • pp.55-62
    • /
    • 2023
  • In this study, Sn-3.0Ag-0.5Cu (wt.%, SAC305) solder dipping process was performed between Ni-foam skeleton with different pore per inch (PPI) to fabricate Ni-foam/SAC305 composite solder, and then applied to the transient liquid phase (TLP) bonding process to evaluate the microstructure and mechanical properties of the bonded joint. The Ni-foam/SAC305 composite solder preform consisted of Ni-foam and SAC305, and an intermetallic compound (IMC) having a (Ni,Cu)3Sn4 composition was formed at the Ni-foam interface. During TLP bonding process, the IMC at the Ni-foam interface was converted to (Ni,Cu)3Sn4+Au, and as the bonding time increased, the Ni-foam and SAC305 continuously reacted, and the bonded joint was converted into an IMC. And it was confirmed that the 130 PPI Ni-foam/SAC305 composite solder joint was converted into an IMC at the fastest rate. As a result of performing a shear test to confirm the effect of Ni-foam on mechanical properties, solder joints under all conditions exhibited excellent mechanical properties of 50 MPa or more in the early stages of the TLP bonding process, and the shear strength tends to increase as the bonding time increases.

Auto-stereoscopic 60 view 3D using slanted Lenticular lens array

  • Im, Hee-Jin;Lee, Byung-Joo;Hong, Hyung-Ki;Shin, Hyun-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1500-1503
    • /
    • 2007
  • Auto-stereoscopic 3D of 60-view number is made using slanted lenticular lens array and LCD of 15.1 inch diagonal size and 3200 by 2400 pixel numbers. Due to its large view number, smooth motion parallax is observed and the visual fatigue is reduced.

  • PDF

100W On-Board Power Supply Using Flat Transformer (Flat Transformer를 이용한 100W급 On-Board Power Supply)

  • 황치면;송두익;조정구;정창용;홍승대;하태복
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.577-580
    • /
    • 1999
  • High power density on-board power supply is implemented by using flat transformer. In the high frequency switching converters, large leakage inductance increases the switching stress and duty cycle loss, which sometimes limits maximum switching frequency. The flat transformer is designed by using special core structure, which has very low profile and low temperature rise since the thermal loading is spread evenly over a larger area. 100W, 3.3V output on board supply is built and tested and 50.7W/$\textrm{inch}^{3}$ power density is achieved.

  • PDF

Environmental Assessment of Chemically Strengthened Glass for Touch Screen Panel by Material Life Cycle Assessment (물질전과정평가를 이용한 터치스크린패널용 화학강화유리에 대한 환경성 평가)

  • Lee, Na-Ri;Lee, Soo-Sun;Kim, Kyeong-Il;Hong, Tae-Whan
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.301-306
    • /
    • 2012
  • Rapidly growing mobile machines such as tablet PC and smart phone are equipped with touch screen panel using a sturdy material for products surface protection. Therefore, surge of chemically strengthened glass was increased and the amount of waste matter is proportional to demand. The purpose of this study is environmental impact assessment on touch screen panel of chemically strengthened glass by material life cycle assessment (MLCA). We used CES of Granta, SimaPro and Gabi software for MLCA. Chemically strengthened glass (2.7, 5.7 and 10.3 inch) was calculated to environmental impact assessment by Granta software under two cases. One case is Landfill and the other case is Reuse. As a result, in case of reuse, energy values of 2.7, 5.7 and 10.3 inches were reduced by an average of 51.4%, $CO_2$ values were reduced by an average of 46.6% than Landfill case, respectively. We assessed impact categories of 11 types using SimaPro software. As a result, the contents of fossil fuels, inorganics and climate change have a huge impact than the other impact categories. And the main cause of environmental impact is antimony and hydrogen fluoride in Gabi results.

INTERRELATIONSHIP BETWEEN MANDIBULAR CONDYLAR HEAD POSITION IN TRANSCRANIAL VIEW AND ARTICULAR DISC POSITION (경두개방사선사진에서의 하악과두 위치와 관절원판 위치간의 상호관계)

  • Ko Jae-Hee;Choi Soon-Chul;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.319-330
    • /
    • 1995
  • This study was designed to evaluate the interrelationship between the condylar head position in transcranial view and the articular disc position in the arthrography. The condylar positions were assessed by subjective method and linear measurement method on the transcranial view. The subjects for this study consisted of 24 symptomatic joints with normal disc position, 37 joints with anterior disc displacement with reduction and 44 joints with anterior disc displacement without reduction that were classified by arthrotomography under the fluoroscopic guidance. The interrelationship between the condylar head position in transcranial view and the articular disc position in the arthrography was evaluated by Chi square test. The obtained results were as follows : 1. There was no significant interrelationship between the position of condylar head in closed mouth state on transcraniaJ view and articular disc position in the arthrography (p>0.05). 2. There was no significant interrelationship between the changes of interarticular distance in 1 inch opening state and articular disc position in the arthrography (p>0.05). 3. There was no significant interrelationship between the position of condylar head related to the apex of articular eminence in 1 inch opening state and articular disc position in the arthrography(p>0.05). 4. There was significant interrelationship between the changes of interarticular distance that is assessed by linear measurement method in maximum opening state and articular disc position in the arthrography(p<0.05), but there was no significant interrelationship when the condylar head position was assessed by subjective method(p>0.05). 5. There was significant interrelationship between the degree of condylar translation in maximum opening state and articular disc position in the arthrography(p<0.05). 6. The correlation coefficient between two methods to assess the position of condylar head were 0.7989: the condylar head position in articular fossa in closed state, 0.6847: interarticular space in 1 inch opening state, 0.8965: the degree of condylar translation in 1 inch opening state, 0.5944: the changes of interarticular space in maximum opening state, 0.9215: the degree of condylar translation in maximum opening state.

  • PDF

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Physico-chemical Meat Quality Properties and Nutritional Composition of Hanwoo Steer Beef with 1++ Quality Grade (1++ 등급 거세한우의 부위별 이화학적 육질특성 및 영양성분조성)

  • Cho, S.H.;Kim, J.H.;Seong, P.N.;Cho, Y.M.;Chung, W.T.;Park, B.Y.;Chung, M.O.;Kim, D.H.;Lee, J.M.;Ahn, C.N.
    • Food Science of Animal Resources
    • /
    • v.28 no.4
    • /
    • pp.422-430
    • /
    • 2008
  • This study was conducted to investigate the nutritional composition and meat quality properties of Hanwoo steer beef by different cut. Ten cuts [Abjin (short plate), Bosup (top sirloin), Cheggt (striploin), Dngsim (loin), Guri (chuck tender), Hongduke (eye of round), Moksim (chuck roll), Sulgit (bottom round), Udoon (top round), Yanaji (brisket)] prepared from 10 Hanwoo steers (28-30 months old) were used for this experiment. The range of pH was 5.46-5.64. In the chemical analysis, Hongduke contained highest protein contents (21.15%) and Dngsim had lowest protein contents (16.94%) (p<0.05). Fat contents were higher in Dngsim whereas those of Guri, Hongduke and Udoon were significantly lower when compared to the other cuts (p<0.05). There were not significantly different in meat color (L, a and b values) properties only except that L values were significantly higher in Dngsim among 10 cuts (p<0.05). Cooking loss (%) was higher in Guri, Hongduke, Udoon and Yangji whereas it was significantly love. in Cheggt (p<0.05). Warner-Bratzler shear force (WBS) was significantly higher in Abjin $(6.24inch^2/kg)$, whereas Dngsim $(3.45inch^2/kg)$ and Cheggt $(3.50inch^2/kg)$ were significantly lower than the other cuts (p<0.05). There was no significant difference in water-holding capacity (WHC) among 10 cuts (p>0.05). Total amino acid contents were significantly higher in Hongduke (p<0.05). Hongduke was highest in most kinds of amino acids, however, Udoon had the highest methionine and histidine contents among 10 cuts (p<0.05). Glutamate contents were high in all cuts and followed by aspartate, leucine and lysin. With regard to mineral contents, Ca was ranged from 47.63-70.69 mg/kg and Fe was ranged from 15.09-26.68 mg/kg in 10 cuts. Zn was highly contained in Guri (50.56 mg/kg) when compared to the other cuts (p<0.05).

A TOMOGRAPHIC STUDY OF CONDYLAR POSITION IN ASYMPTOMATIC SUBJECTS WITH MALOCCLUSION (부정교합자의 하악과두 위치에 관한 단층방사선학적 연구)

  • Kim Young Ju;Ko Kwang Jun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.19 no.1
    • /
    • pp.105-121
    • /
    • 1989
  • The author analysed tomograms and submento-vertex radiograms of 90 temporomandibular joints from 45 asymptomatic young adults. 15 had Angle class Ⅰ malocclusion, 15 classⅡ and 15 class Ⅲ. Corrected lateral tomograms were obtained in three condylar positions; centric occlusion, centric relation and 1 inch mouth opening. The condylar angulation, depth of cut, joint spaces were analysed in each radiogram. The obtained results were as follows; 1. The mean condylar angulation in Angle class Ⅰ, Ⅱ, Ⅲ group was 17.55±5.51° 13.33±8.85° 16.25±6.60° respectively, and there was no significant difference in each group. The mean condylar angulation of right side (16.62±7.23°) was larger than left side (14.80±7.33°). 2. The mean depth of cut in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.13±1.61㎝, 3.05±3.80㎝, 7.75±2.19㎝, respectively. Angle class Ⅰ and class Ⅱ group revealed significant difference in measurement (p<0.0l). 3. The mean height of articular fossa in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.67±3.06㎜, 9.61±2.57㎜, 8.93±2.83㎜, respectively. And the mean width of articular fossa was 19.90±2.80㎜, 19.48±3.83㎜, 20.36±4.82㎜, respectively. 4. The mean height and width of condylar head was 5.11±1.16㎜, 11.20±2.26㎜, respectively. 5. In centric occlusion, the superior joint space was the largest (3.42±1.42㎜), followed by anterior joint space (2.94±1.95㎜) and the posterior joint space (2.64±1.19㎜. In centric relation, the anterior joint space was the largest (3.86±2.17㎜), followed by the superior joint space (3.64±3.68㎜) and the posterior joint space (1.18±0.77㎜). 6. The displaced measurement from centric relation to centric occlusion was 1.10±1.04㎜ anteriorly and 0.24±0.97㎜ inferiorly. In 1 inch mouth opening state, the condylar head displaced posteroinferiorly (2.49±2.49㎜ posteriorly, 1.17±1.34㎜ inferiorly) from the apex of articular eminence. And Angle class Ⅰ and Ⅱ group, Angle class Ⅱ and Ⅲ group revealed significant difference in posterior measurement, respectively (p<0.01).

  • PDF