13 Tesla급 초전도 마그네트의 개발 (Development of 13 Tesla Superconducting Magnet)

  • 조전욱;이언용;진홍범;권영길;하동우;오봉환;나완수;오상수;류강식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.195-198
    • /
    • 1994
  • The design and construction of a 13 Tesla / 46 mm bore superconducting magnet is presented. The system consists of an 5 Tesla outer NbTi coil with a bore I.D. of 144m, a winding O. D. of 208mm and the length of 200mm which is connected in series with a 200mm long insert coil constructed of multi filamentary $Nb_3Sn$. The insert coil was reacted after winding. Also, epoxy impregnation is accomplished at $Nb_3Sn$ coil using a low viscosity crack resistant epoxy which is forced into the coil with a series of vacuum and over atmosphere pressure cycle.

  • PDF

3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상 (High-resolution Spiral-scan Imaging at 3 Tesla MRI)

  • 김판기;임종우;강승원;조상흠;전수열;임헌진;박호종;오승준;이흥규;안창범
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.108-116
    • /
    • 2006
  • 목적 : 3.0 Tesla 고 자장에서 고 해상도 나선주사영상을 수행하였다. 나선주사영상은 초고속 영상기법의 하나로서, Echo Planar Imaging(EPI)에 비하여 eddy current 가 작게 발생하고, 경사자계 파형의 기울기가 완만하여 상대적으로 낮은 slew rate 를 가진 경사자계시스템으로 구현이 가능한 장점이 있다. 또한 고 자장 영상에서 고속스핀에코(Fast Spin Echo: FSE) 등의 rf 에코 기반의 고속영상방법에서 심각하게 대두되는 SAR 문제가 근원적으로 발생하지 않는 장점이 있어 고 자장에서의 초고속영상방법으로 주목을 받고 있다. 본 연구에서는 3.0 Tesla 에서 나선주사방식으로 고 해상도 영상을 얻어 고 자장 MRI에서 나선주사영상기법의 다양한 응용 가능성을 살펴보고자 한다. 대상 및 방법 : 3 Tesla 전신 자기 공명 영상 시스템에서 다양한 해상도의 나선주사영상 방법을 개발하였다. 고차(higher-order) shimming 을 통하여 영상의 화질을 개선하였고, 해상도에 맞게 interleaves 수를 조절하였다. 스핀에코 와 gradient에코 기반 나선주사영상방법을 구현하였고, 에코 time 과 repetition time, rf 회전 각도를 조절하여 영상의 대조도(contrast)와 신호대잡음비를 조절하였다. 결과 : 3 Tesla 전신 자기 공명 영상 시스템에서 나선 주사 방법을 이용하여 다양한 해상도의 영상을 얻었다. 고 자장에서 주 자장의 불균일도(inhomogeneity) 의 절대 크기가 커지기 때문에 이를 줄이기 위한 shimming 이 더욱 중요해진다. 한번의 스캔으로 axial, sagittal, coronal 방향의 불균일도 map을 구하여 spherical harmonics 분석으로 고차 shimming을 하였다. 팬텀과 in-vivo 두부 영상에서 single shot 나선주사 영상으로 $100{\times}100$ 정도의 영상과 6-12 정도의 interleaves 를 적용하여 $256{\times}256$ 의 고 해상도 영상을 얻을 수 있었다. 결론 : 신호대잡음비의 향상과 스펙트럼의 분리, 뇌기능영상에서 BOLD 효과 향상 등으로 고자장 영상에 대한 관심이 높아지고 있다. 그러나 고 자장 영상에서의 rf field 에 의한 SAR 증가는 중요한 제한 요소로 부각되고 있다. 나선주사영상은 SAR 문제가 근원적으로 발생하지 않고, EPI에 비하여 하드웨어 요구 조건이 낮아 고 자장에서의 고속영상방법으로 적합하다. 본 논문에서는 고차 shimming 을 통하여 불균일도를 개선하고, single shot 과 interleaving 을 적용한 multi-shot 나선주사영상 기법으로 $100{\times}100$에서 $256{\times}256$의 고해상도 영상을 얻어 고 자장에서 초고속영상기법으로 다양한 적용 가능성을 보였다.

  • PDF

3.0-Tesla 자기공명 영상장치용 TX/RX L-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.175-175
    • /
    • 2001
  • 목적: 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type T/L-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다. 3.0 Tesla 자기공명 영상장치에 사용을 위한 Quadrature type의 L-spine TX/RX RF 코일을 개발하여 고자장 자기공명 영상장치에서의 임상진단 활용범위의 확대를 목적으로 한다.

  • PDF

3.0-Tesla 자기공명 영상장치용 TX/RX L-spine RF Coil의 개발

  • 류연철;류승학;최보영;오창현
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.145-145
    • /
    • 2001
  • 목적 현재 3.0T MRI system은 세계적으로 개발이 진행되고 있는 가운데, 3.0T에서 사용 할 수 있는 RF coil의 개발이 시급한 상황이다. 1.0T 및 1.5T MRI 와는 달리 3.0T에서 사용할 수 있는 Body coil 및 그에 따른 High power RF amplifier 제작에 많은 제약이 있다. 작은 용량의 RF amplifier를 이용하여 신체의 부분을 촬영 하고자 한다면, Tx/Rx 가능한 coil을 이용하면 가능할 것이다. 이러한 이유로 본 연구에서는 Tx/Rx 가능한 Quadrature type Th-spine RF coil을 설계, 제작하여 3.0T 고자장 자기공명 영상장치에서의 임상진단 활용범위를 확대하였다. 3.0 Tesla 자기공명 영상장치에 사용을 위한 Quadrature type의 L-spine TX/RX RF 코일을 개발하여 고자장 자기공명 영상장치에서의 임상진단 활용범위의 확대를 목적으로 한다.

  • PDF

강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교 (Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T.)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제12권2호
    • /
    • pp.193-199
    • /
    • 2018
  • 본 연구는 총 15명의 정상인 지원자를 대상으로 1.5T와 3.0T의 자기공명영상기기(Philips, Medical System, Achieva)를 이용하여 강자성 인공물을 최소화하기 위한 최적의 Tesla를 알아보고자 하였다. 평가는 신호대 잡음비 평가, 강자성 인공물이 형성된 부위의 길이와 Histogram을 평가하였다. 분석방법으로는 T1, T2 sagittal 영상의 Background의 4 부위에 관심영역을 설정하고 L3, L4, L5의 각 추체부에 관심영역을 설정한 후 신호대잡음비 값을 측정하였고, 인공물이 형성된 3 부위에 관심영역을 설정하고 길이 값을 측정하였고, Image J 프로그램을 이용해 인공물 영역의 히스토그램 분포 값을 측정하였다. 본 실험에 대한 결과로 신호대 잡음비 평가에서 L3에서는 1.5T와 3.0T 사이에 별 차이가 없는 것으로 나타났고, L4, L5에서는 큰 차이가 있는 것으로 나타났다(p<0.05). 강자성 인공물이 형성된 3 부위의 길이는 3.0T에 비해 1.5T가 더 짧아 주변조직에 대한 진단적 정보를 더 얻을 수 있는 것으로 나타났다(p<0.05). Histogram평가에서는 3.0T보다 1.5T가 Count값이 높게 나타났다(p<0.05). 결론적으로 1.5T와 3.0T의 신호대 잡음비, 강자성 인공물의 길이, Histogram을 비교 평가해 봤을 때, Spine MRI 검사 시에 PLIF 등 디스크 수술을 받은 환자에게는 Low Tesla로 검사가 최적의 영상정보를 얻을 수 있었다.

Accuracy Analysis of Magnetic Resonance Angiography and Computed Tomography Angiography Using a Flow Experimental Model

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Park, Cheol-Soo;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • 제20권1호
    • /
    • pp.40-46
    • /
    • 2015
  • This study investigated the accuracy of magnetic resonance angiography (MRA) and computed tomography angiography (CTA) in terms of reflecting the actual vascular length. Three-dimensional time of flight (3D TOF) MRA, 3D contrast-enhanced (CE) MRA, volume-rendering after CTA and maximum intensity projection were investigated using a flow model phantom with a diameter of 2.11 mm and area of $0.26cm^2$. 1.5 and 3.0 Tesla devices were used for 3D TOF MRA and 3D CE MRA. CTA was investigated using 16 and 64 channel CT scanners, and the images were transmitted and reconstructed by volume-rendering and maximum intensity projection, followed by conduit length measurement as described above. The smallest 3D TOF MRA measure was $2.51{\pm}0.12mm$ with a flow velocity of 40 cm/s using the 3.0 Tesla apparatus, and $2.57{\pm}0.07mm$ with a velocity of 71.5 cm/s using the 1.5 Tesla apparatus; both images were magnified from the actual measurement of 2.11 mm. The measurement with the 16 channel CT scanner was smaller ($3.83{\pm}0.37mm$) than the reconstructed image on maximum intensity projection. The images from CTA from examination apparatus and reconstruction technique were all larger than the actual measurement.

Brain MRI 검사 시 치아 임플란트 시술유무와 RF Pulse 세기에 따른 인체 영향에 관한 연구: XFDTD 프로그램을 이용 (Study on the Human Influence according to RF Pulse Intensity by use Dental Implant on BRAIN MRI: Using the XFDTD Program)

  • 최대연;김동현
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.361-370
    • /
    • 2017
  • Brain MRI 검사에서는 영상을 얻기 위해 RF Pulse를 인체에 조사하게 되는데 이때 조사된 RF Pulse 에너지의 상당 부분은 우리 몸에 그대로 흡수되게 되고 이로 인해 인체 온도가 상승하게 되는데 노출 정도에 따라 인체에 영향을 주게 된다. 이러한 RF Pulse 에너지는 MRI 장비의 발전으로 인해 자기장의 세기가 1.5 Tesla에서 3 Tesla, 3 Tesla에서 7 Tesla로 높아지는 시점에서 자기장의 세기 변화에 따른 두부 전체의 SAR와 온도의 변화를 알아보고 위의 결과가 치아 임플란트 사용 여부에 따른 결과의 차이를 알아보기 위해 연구를 시작하게 되었다. 실험은 인체 두부 모델에 1.5 Tesla MRI 장비에서 발생되는 64 MHz RF Pulse 주파수, 3.0 Tesla MRI 장비에서 발생되는 128 MHz RF Pulse 주파수, 7 Tesla MRI 장비에서 발생되는 298 MHz RF Pulse 주파수를 조사하고 위의 실험을 치아 임플란트를 사용하였을 때와 사용하지 않았을 때로 나누어 XFDTD 프로그램을 사용하여 머리 주변의 SAR와 체온의 변화를 각각 실험하였다. 치아 임플란트를 하지 않았을 때보다 치아 임플란트를 하였을 때 SAR값은 7T의 RF Pulse 주파수 256MHz에서 최대 약 5800배의 차이를 나타냈으며 주파수가 증가할수록 치아 임플란트 사용으로 인한 SAR값의 차이는 크게 나타났다. 치아 임플란트를 하지 않았을 때보다 치아 임플란트를 하였을 때 두부전체의 온도변화는 2배에서 최대 4배 가까운 온도 상승을 나타내었다. 또한 RF Pulse 주파수가 증가할수록 SAR값은 증가하지만, 두부 전체의 온도는 감소하였는데 이는 주파수가 증가할수록 파장이 작을수록 인체표면에 흡수되는 양이 많아지기 때문이다. 향후 치아 임플란트 유무와 RF Pulse 주파수의 세기 변화로 인한 이상 반응 요인에 대한 연구를 통해 인체의 생리적 연구와 생화학적 연구 등 인체에 대한 영향과 관련하여 연구가 필요하다고 하겠다.

Depiction of Acute Stroke Using 3-Tesla Clinical Amide Proton Transfer Imaging: Saturation Time Optimization Using an in vivo Rat Stroke Model, and a Preliminary Study in Human

  • Park, Ji Eun;Kim, Ho Sung;Jung, Seung Chai;Keupp, Jochen;Jeong, Ha-Kyu;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제21권2호
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. Materials and Methods: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a $B_{1,rms}$ amplitude of $1.2{\mu}T$ using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. Results: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at $1.2{\mu}T$ power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. Conclusion: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the $1.2{\mu}T$ power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.

Study on the Surface Magnetic Domain Structure of Thin-Gauged 3% Si-Fe Strips using Scanning Electron Microscopy with Polarization Analysis

  • Chai, K.H.;Heo, N.-H.;Na, J.g.;Lee, S.R.;Woo, j.s.
    • Journal of Magnetics
    • /
    • 제3권2호
    • /
    • pp.44-48
    • /
    • 1998
  • Scanning Electron Microscopy with Polarization Analysis (SEMPA) was used to image the surface magnetic domain structure of the 100 ${\mu}{\textrm}{m}$ thick 3% Si-Fe sheet. The thin-gauged 3% Si-Fe strips with magnetic induction ($B_{10}$) from 1.98 to 1.57 Tesla were prepared via conventional metallurgical processes including melting, hot-and cold-rolling, intermediate annealing and final annealing. Using SEMPA, it was observed that the $B_{10}$ (1.98 T) Tesla sample was almost composed of 180$^{\circ}$ stripe domains which are parallel to rolling direction. On the other hand the 3% Si-Fe sheet with $B_{10}$ (1.57 T) Tesla was composed of large 180$^{\circ}$stripe domains that are slanted about 30$^{\circ}$to the rolling direction and complex magnetic domain structures like tree and zigzag pattern. The 180$^{\circ}$stripe domains, which covered a major part of the sample, had (110)<001> Goss texture parallel to the rolling direction. The domain walls between 180$^{\circ}$stripe domains were the conventional Bloch type walls. On the other hand, the 90$^{\circ}$domains, which covered minor part on edge of the sample, were observed in (200) grains. The domain walls between 90$^{\circ}$domains were the Neel type walls. In high magnification, the elliptical singularity at the Neel walls was clearly observed.

  • PDF