• Title/Summary/Keyword: 3축성

Search Result 94, Processing Time 0.022 seconds

A reevaluation of the castles and palaces of Goryeo Gangdo (江都) using GIS (고려 강도(江都)의 성곽과 궁궐 재고찰)

  • KANG, Dongseok
    • Korean Journal of Heritage: History & Science
    • /
    • v.54 no.4
    • /
    • pp.174-191
    • /
    • 2021
  • Gangdo (江都), a reproduction of Gaegyeong, was the capital of Goryeo for 39 years. However, due to the urgent wartime situation of the Mongol invasion and the geographical features of Ganghwa Island, the castle system and palace layout were somewhat different from those of Gaegyeong. Gangdo's castle can be understood as a triple castle system consisting of outer castle, middle castle, and inner castle. First, the outer castle was the first to be completed, and it was built at the forefront to prevent the Mongol army from invading in the first place. It is presumed that the section was between Huamdon and Hwadodon in the outer castle during the Joseon Dynasty. The middle castle can be seen as the present 'Middle Castle', a castle built of earth on the outskirts of the Ganghwa-mountain Castle. Considering the sophistication and robustness of the construction method confirmed in the archaeological research, this castle is thought to have been built under a meticulous plan. In other words, as the capital city, it was completed 'at last' as recorded in the Koryo History, after a long 18-year construction process to protect palaces, government offices, and private houses. The inner castle was a castle with the character of a palace. This corresponds to the Old Castle of Ganghwabu (江華府) during the Joseon Dynasty, and it almost coincided with the scale of the composition of Gaegyeong's palace castle. It was a complex functional space, featuring the integration of the palace and the imperial castle, where the main government offices and ancillary facilities, including the palace, were located. Based on the documentary record that these palaces were similar to Gaegyeong's palace, the palace map was overlapped with that of Gaegyeong. The central axis of the building from Seungpyeongmun (昇平門) to Seongyeongjeon (宣慶殿) coincided with Kim Sangyongsunjeol Monument in Ganghwa- Goryeo Palace. Therefore, it seems that the palace of Gangdo had the same basic structure as that of Gaegyeong. However, the inner palace and annexed buildings must have been arranged in consideration of the topographical conditions of Ganghwa, and this is estimated to be the Gunggol area in Gwancheong-ri.

The Effect of Physic Function and Quality of Life in Patient with Amyotrophic Lateral Sclerosis through Physical Therapy and Occupational Therapy: A Case Study (물리치료와 작업치료가 근위축성측삭경화증 환자의 신체적 기능과 삶의 질에 미치는 영향: 사례연구)

  • Lee, Tae-Sik;Kim, Hwan-Hee
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.5
    • /
    • pp.77-85
    • /
    • 2007
  • Purpose: This study was to investigated the effect of physical function and quality of life through physical therapy and occupational therapy by Bobath approach to patient with ALS. Methods: The data of 1 patient with ALS, who visited D hospital in Busan, was collected from June 5, 2006 to August 19, 2007. To determine the physical function and quality of life, Berg Balance Scale (BBS), Gait, Skate. Purdue Pegboard, WHOQOL-BREF, COPM were used. Results: BBS score was increased 0 to 33 in the pre and post test. Gait distance was increased 0m to 500m in pre and post test. Skate score was increased 13 to 22 in the pre and post test, Purdue Pegboard score was increased 0 to 3 in the pre and post test, WHOQOL-BREF was increased 1.92 to 2.46 in the pre and post test. Average COPM score of performance and satisfaction grade of pre test score was 1 then Post test score of performance score increased to 5.7 and satisfaction increased to 4. Conclusion: Physical therapy and Occupational therapy increase physical function and quality of life in ALS patients. Physical therapy and occupational therapy should study more about patients with ALS.

  • PDF

Amyotrophic lateral sclerosis combined with Hashimoto's thyroiditis : A case report (하시모토 갑상선염을 동반한 근위축성 측삭경화증 1예)

  • Ko, Yung-Chai;Kang, Sung-Soo;Lee, Young-Bae;Park, Hyeon-Mi;Shin, Dong-Jin
    • Annals of Clinical Neurophysiology
    • /
    • v.3 no.1
    • /
    • pp.37-39
    • /
    • 2001
  • Although the etiology and pathogenesis of amyotrophic lateral sclerosis(ALS) is unknown, increasing evidence supports a role for autoimmune mechanisms in motor neuron degeneration. The coexistence of immune disease in ALS supports that an altered immune system may contribute to disease pathogenesis. A 55-year-old woman was admitted to our department due to dysarthria and gait disturbance. On physical and neurologic examination, she showed thyroid enlargement, tongue atrophy, muscle weakness, fasciculation, and increased deep tendon reflex. The electrophysiological studies are compatible with motor neuron disease. Cytological findings of thyroid were compatible with Hashimoto's thyroiditis. Thus, we report a case of ALS combined with Hashimoto's thyroiditis. And the simultaneous presentation with ALS and Hashimoto's thyroiditis led us to consider whether this was simply a chance association or not.

  • PDF

Ductility Degradation Assessment of Baffle Former Assembly Considering the Stress Triaxiality Effect (응력 삼축성을 고려한 원자로 내부구조물 배플포머 집합체의 연성저하 평가)

  • Kim, Jong-Sung;Park, Jeong Soon;Kang, Sung-Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.2
    • /
    • pp.50-57
    • /
    • 2016
  • The study presents structural integrity assessment of ductility degradation of a baffle former assembly by performing finite element analysis considering real loading conditions and stress triaxiality. Variations of fracture strain curves of type 304 austenitic stainless steel with stress triaxiality are derived based on the previous study results. Temperature distributions during normal operation such as heat-up, steady state, and cool-down are calculated via finite element temperature analysis considering gamma heating and heat convection with reactor coolant. Variations of stress and strain state during long operation period are also calculated by performing sequentially coupled temperature-stress analysis. Fracture strain is derived by using the fracture curve and the stress triaxility. Finally, variations of ductility degradation damage indicator with the fracture strain and the equivalent inelastic strain are investigated. It is found that maximum value of the ductility degradation damage index continuously increases and becomes 0.4877 at 40 EFPYs. Also, the maximum value occurs at top and middle inner parts of the baffle former assembly before and after 20 EFPYs, respectively.

Fatigue Crack Initiation around a Hole under Out-of-phase Biaxial Loading (이상 이축 하중 하에서 구멍 주위에서의 피로 균열 발생)

  • Huh, Yong-Hak;Park, Pi-Lip;Kim, Dong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1695-1702
    • /
    • 2003
  • Fatigue crack initiation around a hole subjected to biaxial fatigue loads with a phase difference was investigated. Axial and torsional biaxial fatigue loads with different phase differences and biaxiality of 1/√3 were applied to thin-walled tubular specimens. Five phase differences of 0, 45, 90, 145 and 180 degrees were selected. Directions of the fatigue crack initiation around the hole were found to approach to the circumferential direction of the specimen with increment of the phase difference for fatigue tests with phase differences less than 90$^{\circ}$. Whereas directions for tests with phase differences greater than 90$^{\circ}$ got away from the circumferential direction and those were symmetric to the directions for tests with phase difference less than 90. . Furthermore, it was shown that the fatigue initiation life decreased with increment of phase difference for fatigue tests with phase differences less than 90$^{\circ}$, but it increased for tests with phase difference greater than 90$^{\circ}$. The crack initiation direction can be successfully explained by using the direction of the maximum tangential stress range obtained around the hole and at far-field.

The study on the color change according to zirconia core thickness, and build-up technique using spectrophotometer (Spectrophotometer를 이용한 지르코니아 코어의 두께 및 도재축성법에 따른 색조의 변화에 대한 연구)

  • Huh, Sung-Yoon;Kim, Jae-Hong;Son, Ho-Jung
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.313-321
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color parameters of different fabrication method of Lava ceram powder, Lava DVS blocks, IPS e.max ceram and IPS e.max zirpress. Methods: The three available shades(A1, A2, A3.5) of Lava & Kavo zirconia blocks were examined. For each of three colors, three different thickness were tested, 5 times of measurement frequency. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: Lava build-up group and Lava DVS group showed clinically perceived color difference, on the other hand IPS e.max build-up group and IPS e.max zirpress group did not show clinically perceived color difference to shade allowed on core. When the thickness of porcelain veneer increased from Lava and IPS e.max groups, color differences(${\Delta}E$) were decreased. Conclusion: All-ceramic system has color characteristics that clinicians have to consider when selecting materials. Also, manufacturers of different porcelain systems must make every effort to achieve color reproducibility.

Amyotrophic Lateral Sclerosis Combined with Abnormal Sensory Nerve Conduction (감각신경전도 이상을 동반한 근위축성측색경화증)

  • Seo, Sang Hyuk;An, Jae Young;Lee, Taek-Jun;Suh, Yeon-Lim;Shin, Kyong Jin;Kim, Byoung Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.7 no.2
    • /
    • pp.133-137
    • /
    • 2005
  • Underlying neuropathies combined with amyotrophic lateral sclerosis (ALS) cast doubt on the diagnosis of ALS when present. Abnormal sural nerve conductions were found in 3 patients with clinically definite ALS. Pathologically demyelinating, axonal, or vasculitic neuropathy was suggested respectively. High dose oral corticosteroid had no effect and clinical courses were deteriorating in all the patients. The causes of combined neuropathies were unclear. Possibility of direct consequence of ALS, concomitant neuropathies, or rare variants of ALS should be considered in these cases.

  • PDF

Numerical Analysis on the Flow Field and Heat Transfer Characteristics of Longitudinal Vortices in Turbulent Boundary Layer - On the Common Flow Down - (3차원 난류경계층 내에 존재하는 종방향 와동의 유동장 및 열전달 특성에 관한 수치해석(I) - Common Flow Down에 관하여 -)

  • Yang Jang-Sik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.789-798
    • /
    • 2005
  • This paper is a numerical study concerning how the interactions between a pair of the vortices effect flow field and heat transfer. The flow field (common flow down) behind a vortex generator is modeled by the information that is available from studies on a half-delta winglet. Also, the energy equation and the Reynolds-averaged Wavier-Stokes equation for three-dimensional turbulent flows, together with a two-layer turbulence model to resolve the near-wall flow, are solved by the method of AF-ADI. The present results predict that the boundary layer is thinned in the regions where the secondary flow is directed toward the wall and thickened where it Is directed away from the wall. Although some discrepancies are observed near the center of the vortex core, the overall performance of the computational model is found to be satisfactory.

A Study on the Architectural Characteristic Jang-Dae of Castle in the Joseon Dynasty (조선시대 성곽 장대의 건축특성에 관한 연구)

  • Kim, Ki-hyeon;Chang, Hun-duck
    • Korean Journal of Heritage: History & Science
    • /
    • v.48 no.2
    • /
    • pp.120-141
    • /
    • 2015
  • This paper is a preliminary study of architectural characteristics of Jangdae (general's podium), which shows one of the technical changes in fortification of Joseon Dynasty. As a facility for commands of generals and training for officers and men, it was located inside a fortress. Although it is not certain when the first Jangdae was built, the number of them dramatically increased around 18th century. Since the top priority function of the Jangdae was the prospect, it was installed at the hilly spot with open architecture. In addition, the open structure of Eupseong fortress towers on the riverside banks could simultaneously offer the functions as viewing around and Jangdae. Since Jangdae was also a place for military drills and reviews of soldiers, a wide podium was positioned at the front to muster the soldiers. This feature was standardized in the space organization of Jangdae in Joseon, and a mere podium was installed unless the topographic restrictions allows enough space. On the other hand, as a place for a commander, the hierarchy of the Jangdae was revealed through a variety of architectural characteristics. The hierarchy was assigned to the commander's space through the altitude difference, and diverse ornaments were added to show a sense of class. The floor plan of the Jangdae building can be largely categorized into rectangle and square, and the typical sizes of the former are $5{\times}4$ Kans (traditional measuring unit between two columns) and $3{\times}2$ Kans. Out of these two types, buildings of $5{\times}4$ Kans were found in flat land and eupseong fortresses with large space, and the relatively smaller ones of $3{\times}2$ Kans in mountain fortresses. All buildings of square floor plan had $3{\times}3$ Kans style, and the center Kan was twice wider than the side Kan to make the central space wide. It seems that the purpose was to secure the interior space of the upper story because the center Kan accounts for the floor area of the upper story. Some Jangdae's had internal story to form overhead space. The multi-roofed tower style with eaves attached to the upper and lower story is found exclusively in Jangdae. The buildings shows the Onkanmulim style which extends Naejinju (inner column) of the lower story to be the Byeonju (outer column) of the upper story, and the log-framed floor in the upper floor was structured by inserting the Changbang (connecting beam) between the Naejinju's and joining the log frames. In addition, the towers in eupseong fortresses had log-framed floor in the upper floor by setting up the high Nuhaju (column underneath a roof) and joining Cheongbang to the upper part of the column while it cannot be regarded as multi-roofed because only the upper part has a roof.

CT Evaluation of Long-Term Changes in Common Bile Duct Diameter after Cholecystectomy (담낭 절제술 후 총담관 직경의 장기 변화에 대한 CT 평가)

  • Sung Hee Ahn;Chansik An;Seung-seob Kim;Sumi Park
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.581-595
    • /
    • 2024
  • Purpose The present study aimed to investigate the frequency and extent of compensatory common bile duct (CBD) dilatation after cholecystectomy, assess the time between cholecystectomy and CBD dilatation, and identify potentially useful CT findings suggestive of obstructive CBD dilatation. Materials and Methods This retrospective study included 121 patients without biliary obstruction who underwent multiple CT scans before and after cholecystectomy at a single center between 2009 and 2011. The maximum short-axis diameters of the CBD and intrahepatic duct (IHD) were measured on each CT scan. In addition, the clinical and CT findings of 11 patients who were initially excluded from the study because of CBD stones or periampullary tumors were examined to identify distinguishing features between obstructive and non-obstructive CBD dilatation after cholecystectomy. Results The mean (standard deviation) short-axis maximum CBD diameter of 121 patients was 5.6 (± 1.9) mm in the axial plane before cholecystectomy but increased to 7.9 (± 2.6) mm after cholecystectomy (p < 0.001). Of the 106 patients with a pre-cholecystectomy axial CBD diameter of < 8 mm, 39 (36.8%) showed CBD dilatation of ≥ 8 mm after cholecystectomy. Six of the 17 patients with long-term (> 2 years) serial follow-up CT scans (35.3%) eventually showed a significant (> 1.5-fold) increase in the axial CBD diameter, all within two years after cholecystectomy. Of the 121 patients without obstruction or related symptoms, only one patient (0.1%) showed IHD dilatation > 3 mm after cholecystectomy. In contrast, all 11 patients with CBD obstruction had abdominal pain and abnormal laboratory indices, and 81.8% (9/11) had significant dilatation of the IHD and CBD. Conclusion Compensatory non-obstructive CBD dilatation commonly occurs after cholecystectomy to a similar extent as obstructive dilatation. However, the presence of relevant symptoms, significant IHD dilatation, or further CBD dilatation 2-3 years after cholecystectomy should raise suspicion of CBD obstruction.