• Title/Summary/Keyword: 3차원 측정치

Search Result 217, Processing Time 0.026 seconds

Performance Analysis of the Soft Ice-cream Maker Having Two Evaporators Operating at Different Temperatures (두개의 증발기가 장착된 소프트 아이스크림 제조기의 성능 해석)

  • Kim, Jeong-Sik;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.2
    • /
    • pp.517-522
    • /
    • 2013
  • Small size ice-cream maker has two evaporators having different evaporating temperatures of $4^{\circ}C$ and $-8^{\circ}C$. In such case, ice-cream maker system design becomes complicated because multiple capillary tubes affects one another. In this study, performance analysis was conducted for the soft ice-cream maker having two evaporators operating at different temperatures. The compressor was analyzed using efficiency models, the capillary tube was modeled assuming one-dimensional flow, the condenser and the evaporators were modeld based on UA-LMTD method. The refrigeration cycle simulation program was developed applying the enthalpy, pressure and mass balance on each component. Comparison of the test data with the simulated results for R404A revealed that evaporator temperatures of refrigerator and freezer agreed within $3^{\circ}C$.

Contextual Factors and Rating Behavior in the Peer Evaluation System (동료평가 시스템에서의 상황맥락 요인과 평가행동)

  • Park, Jong-Hyuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.175-183
    • /
    • 2012
  • The study investigates peer rating, one of the most commonly used sources of performance rating other than those of supervisors. On the whole, both field and laboratory studies indicate that peer assessment is a valid and reliable evaluation procedure, but on average, peer rating is not usually accurate. The aim of the investigation is to explore the relationship of beliefs and attitude about the performance appraisal system as well as a dispositional characteristic as self-monitoring with rating behavior. In particular, the study tests whether the relationship between rating context variables-appraisal self efficacy and appraisal validity- and rating behavior depends in part on the personality of the rater. Data from 445 undergraduate students are analyzed for hypotheses testing. The study finds evidences that the high on appraisal self efficacy and appraisal validity are more likely to affect discriminating rating tendency and to reduce rating level. Results also show that self-monitoring make the moderating effects between contextual factors and rating behaviors. Some implications, future research directions, and limitations are discussed.

전자부품의 냉각을 위한 자연대류 상관 관계식의 평가

  • 이재헌
    • Journal of the KSME
    • /
    • v.27 no.6
    • /
    • pp.504-514
    • /
    • 1987
  • 복잡한 전자부품의 조립시에 필요한 열적 디자인에 관한 정보는 오래전부터 실험을 통하여 얻어지고 있다. 실험적 데이터를 이용하여 무차원 파라미터로 표시된 실험결과는 꼭 같지는 않지만 현상적으로는 비슷한 상황에 응용될 수 있다. 여기서는 학술문헌에 나타나 있는 자연대류에 관한 실험적인 상관관계식들과 프레임에 수직으로 꽂혀있는 균일가열 전자회로기판의 모델에서 얻어진 무차원 자료들을 비교하고자 한다. 대부분의 자료들은 수정채널 Rayleigh수(Ra")가 15~100범위에 속하며, 이러한 범위는 부품이 조밀하게 배치된 기관이 서로 좁은 채널을 이루고 있으며, 동시에 상당한 전력을 소비하고 있는 경우에 해당한다. Wirt와 Stutzman, Bar-Cohen과 Rohsenow의 일반상관관계식은 AT'||'&'||'T Bell 연구소에서 개발된 전자기기를 이용하여 수집한 실험데이터를 잘 표현하고 있으며 10 < Ra" <1,000범위에서 추천될 수 있다. 두개의 유사한 상관관계식과 비교할 때 상당히 좋은 예측을 보였으며 또한 Sparrow와 Gregg의 연구결과와도 잘 일치하므로 Ra" < 10인 경우에 Aung의 완전발달층류의 채널유동방식, Ra" > 1,000인 경우에는 Aung등의 단일 수직평판 근사식이 추천될 수 있다. Coyne의 알고리즘에 의한 계산치는 10

  • PDF

A New Height Estimation Scheme Using Geometric Information of Stereo Camera based on Pan/tilt control (팬/틸트 제어기반의 스데레오 카메라의 기하학적 정보를 이용한 새로운 높이 추정기법)

  • Ko Jung-Hwan;Kim Eun-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.156-165
    • /
    • 2006
  • In this paper, a new intelligent moving target tracking and surveillance system basing on the pan/tilt-embedded stereo camera system is suggested and implemented. In the proposed system, once the face area of a target is detected from the input stereo image by using a YCbCr color model and phase-type correlation scheme and then, using this data as well as the geometric information of the tracking system, the distance and 3D information of the target are effectively extracted in real-time. Basing on these extracted data the pan/tilted-imbedded stereo camera system is adaptively controlled and as a result, the proposed system can track the target adaptively under the various circumstance of the target. From some experiments using 480 frames of the test input stereo image, it is analyzed that a standard variation between the measured and computed the estimated target's height and an error ratio between the measured and computed 3D coordinate values of the target is also kept to be very low value of 1.03 and 1.18$\%$ on average, respectively. From these good experimental results a possibility of implementing a new real-time intelligent stereo target tracking and surveillance system using the proposed scheme is finally suggested.

Accuracy Evaluation of Tumor Therapy during Respiratory Gated Radiation Therapy (호흡동조방사선 치료 시 종양 치료의 정확도 평가)

  • Jang, Eun-Sung;Kang, Soo-Man;Lee, Chol-Soo;Kang, Se-Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.113-122
    • /
    • 2010
  • Purpose: To evaluate the accuracy of a target position at static and dynamic state by using Dynamic phantom for the difference between tumor's actual movement during respiratory gated radiation therapy and skin movement measured by RPM (Real-time Position Management). Materials and Methods: It self-produced Dynamic phantom that moves two-dimensionally to measure a tumor moved by breath. After putting marker block on dynamic phantom, it analyzed the amplitude and status change depending on respiratory time setup in advance by using RPM. It places marker block on dynamic phantom based on this result, inserts Gafchromic EBT film into the target, and investigates 5 Gy respectively at static and dynamic state. And it scanned investigated Gafchromic EBT film and analyzed dose distribution by using automatic calculation. Results: As a result of an analysis of Gafchromic EBT film's radiation amount at static and dynamic state, it could be known that dose distribution involving 90% is distributed within margin of error of 3 mm. Conclusion: As a result of an analysis of dose distribution's change depending on patient's respiratory cycle during respiratory gated radiation therapy, it is expected that the treatment would be possible within recommended margin of error at ICRP 60.

  • PDF

A Study on the Clinical Characteristics of Burning Mouth Syndrome (구강내 작열감 증후군의 임상적 특징에 관한 연구)

  • Jin-Woo Chung;Ki-Yong Hyun;Sung-Woo Lee
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.2
    • /
    • pp.7-23
    • /
    • 1994
  • 구강내 작열감 증후군은 객관적 징후없이 구강점막에 작열감을 나타내는 만성동통장애이다. 다양한 원인요소들이 제시되어 있지만, 이러한 요소들의 관련성에 대해서는 아직 분명하지 않은 실정이다. 그러므로, 이러한 구강내 기능이상의 근본적이고 효과적인 치료를 위해서는 다양한 임상적 관찰과 원인요소의 분석등이 계속 연구 조사되어져야 할 것이다. 저자는 구강내 작열감 증후군의 증상을 호소하는 112명의 환자의 임상적 특징에 대해 조사하고자, 환자군과 대조군에 대해 구강내 작열감 증후군에 관한 설문조사 및 구강검사와 혈액학적 검사를 시행하였으며, 점도계를 사용하여 구강내 작열감 증후군 환자의 자극이 전타액의 점도를 측정하였다. 또한, 환자의 심리적 요인을 파악하고자 간이정신진단검사를 실시한 결과 다음과 같은 결론을 얻었다. 1. 구강내 작열감 증후군은 주로 페경기 전후의 여성에서 많이 나타났으며, 호발부위는 혀, 치주 및 치조점막, 구개, 협점막의 순이었다. 2. 구강내 작열감 증후군 환자에게서 대조군 비해 구강건조감, 미각 및 수면장애, 빈혈, 소화기 장애, 두통과 기타 다른 신체불편감의 호소 등이 더 많이 나타났다. 3. 혈액학적 검사결과, 구강내 작열감 증후군 환자중의 26%와 12%에서 각각 혈중 엽산농도와 철분농도의 저하를 나타냇다. 4. 자극시 분비된 전타액의 점도는 40대와 50대이상의 연령군에서 구강내 작열감 증후군 환자가 정상인에 비해 높았다.(p<0.01). 5. 구강내 작열감 증후군 환자군의 간이정신진단검사의 각 증상차원 및 전체지표의 T점수의 평균치는 정상범위내에 있었으며, 신체화(SOD)와 우울 (DEP)차원의 평균치가 가장 높았다.

  • PDF

Peripheral Dose Distributions of Clinical Photon Beams (광자선에 의한 민조사면 경계영역의 선량분포)

  • 김진기;김정수;권형철
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The region, near the edge of a radiation beam, where the dose changes rapidly according to the distance from the beam axis is known as the penumbra. There is a sharp dose gradient zone even in megavoltage photon beams due to source size, collimator, lead alloy block, other accessories, and internal scatter ray. We investigate dosimetric characteristics on penumbra regions of a standard collimator and compare to those of theoritical model for the optimal use of the system in radiotherapy. Peripheral dose distribution of 6 W Photon beams represents penumbral forming function as the depth. Also we have discussed that the peripheral dose distribution of clinical photon beams, differences between calculation dose use of emperical penumbral forming function and measurements in penumbral region. Predictions by emperical penumbral forming functions are compared with measurements in 3-dimensional water phantom and it is shown that the method is capable of reproduceing the measured peripheral dose values usually to within the statistical uncertainties of the data. The semiconductor detector and ion chamber were positioned at a dmax depth, 5cm depth, 10cm depth, and its specific ratio was determined using a scanning data. The effective penumbra, the distance from 80% to 20% isodose lines were analyzed as a function of the distance. The extent of penumbra will also expand with depth increase. Difference of measurement value and model functions value according to character of the detector show small error in dose distribution of the peripheral dose.

  • PDF

A three-dimensional finite element analysis of obturator prosthesis for edentulous maxilla (무치악 구개결손 환자를 위한 폐쇄장치의 삼차원 유한요소 분석)

  • Song, Woo-Seok;Kim, Myung-Joo;Lim, Young-Jun;Kwon, Ho-Beom
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.222-228
    • /
    • 2011
  • Purpose: The purposes of this study were to evaluate the stress distributions and the displacements of obturator for edentulous maxillectomy patients and to compare them with those of complete denture using three-dimensional finite element analysis. Materials and methods: Based on the CT image of edentulous patient, three-dimensional finite element model of edentulous maxillae was constructed. Three-dimensional finite element model of edentulous maxillae with palatal defect was also fabricated. On each model, complete denture and obturator prosthesis were created. Vertical static force of 200 N was applied on the left maxillary premolar and molar region. The von Mises stress values and the displacements of models were analyzed using three-dimensional finite element analysis. Results: Maximum von Mises stress values were recorded in the cortical bones of both models. The von Mises stress value in the complete denture model was 2.73 MPa and 2.69 MPa in the obturator model. High von Mises stress values were also observed on the tissue surface of prosthesis. The maximum value of the displacement in the obturator was higher than that of complete denture. Conclusion: The obturator showed a worse result in terms of stress distribution and displacement than complete denture. In the prosthodontic rehabilitation of edentulous maxillectomy patient accurate impression procedure based on patients'anatomy and application of prosthodontic principle should be considered.

Prediction of Target Motion Using Neural Network for 4-dimensional Radiation Therapy (신경회로망을 이용한 4차원 방사선치료에서의 조사 표적 움직임 예측)

  • Lee, Sang-Kyung;Kim, Yong-Nam;Park, Kyung-Ran;Jeong, Kyeong-Keun;Lee, Chang-Geol;Lee, Ik-Jae;Seong, Jin-Sil;Choi, Won-Hoon;Chung, Yoon-Sun;Park, Sung-Ho
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.132-138
    • /
    • 2009
  • Studies on target motion in 4-dimensional radiotherapy are being world-widely conducted to enhance treatment record and protection of normal organs. Prediction of tumor motion might be very useful and/or essential for especially free-breathing system during radiation delivery such as respiratory gating system and tumor tracking system. Neural network is powerful to express a time series with nonlinearity because its prediction algorithm is not governed by statistic formula but finds a rule of data expression. This study intended to assess applicability of neural network method to predict tumor motion in 4-dimensional radiotherapy. Scaled Conjugate Gradient algorithm was employed as a learning algorithm. Considering reparation data for 10 patients, prediction by the neural network algorithms was compared with the measurement by the real-time position management (RPM) system. The results showed that the neural network algorithm has the excellent accuracy of maximum absolute error smaller than 3 mm, except for the cases in which the maximum amplitude of respiration is over the range of respiration used in the learning process of neural network. It indicates the insufficient learning of the neural network for extrapolation. The problem could be solved by acquiring a full range of respiration before learning procedure. Further works are programmed to verify a feasibility of practical application for 4-dimensional treatment system, including prediction performance according to various system latency and irregular patterns of respiration.

  • PDF

Analysis of Lower Somatotype on Adult Women and Appearance Analysis of Flare Skirts by using the Image Processing (성인 여성의 하반신 체형분석과 염상처리를 이용한 플레어 스커트의 외관분석)

  • Lee, Soo-Jung;Hong, Jeong-Min
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.252-258
    • /
    • 1999
  • The aims of this study is to classify the lower somatotype of adult women and appearance analysis on the shape of flare skirts by using the image processing. Also We have made skirts in order to analyze the various types of appearance of flare skirts by using the image processing. The subjects for our wear test lower somatotype, who were controlled in their waist, abdomen and hip shapes. The flare skirts used for wear test were 112 types(combinated 14 fabric type and 8 lower somatotype). The effect of lower somatotype on the shape of flare skirts was determined by the horizontally hem line section shape and the silhouette of flare skirts with image processing. The data were analyzed by using analysis of variance and Turkey, Duncan multiple range test. The results obtained are summarized as follows: It is shown that the fabric weight elongation differs in fabrics properties, in direction of textures. The shape horizontal section of flare skirt hem line has differed with the number of nodes, wave-height of nodes and breadth of silhouette by fabrics properties and lower somatotype. It is noticed that the breadth of flare skirts by the silhouette has high correlation with the drape ability of fabrics and lower somatotype. Results for our flare skirts show changes in amplitude and mean with fabrics, somatotype. Therefore we can say that gray-level histograms are correlated with changes in appearance, differences in drape spacing and related fabric properties and their somatotype.

  • PDF