• Title/Summary/Keyword: 3차원 전자장 해석

Search Result 45, Processing Time 0.026 seconds

An Anisotropic Perfectly Matched Layer(APML) for Mesh Truncation in The Finite Difference Time Domain Method (유한차분시간영역(FDTD)법에 있어 Mesh Truncation을 위한 비등방성 완전정합층에 관한 연구)

  • 박동희;김정기
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.5
    • /
    • pp.678-686
    • /
    • 1998
  • This paper describes an anisotropic perfectly matched layer (APML) for mesh truncation of the Finite Difference Time Domain(FDTD) method. The APML method can classified by a split type and an unsplit type, in case of the split type be made up 12 equations or 8 equations largely, and in case of the unsplit type be made of 6 equations. Therefore the latter is more simple as compare with the former. For the APML method presented in this paper is the latter, is directly derived from the time domain equations of Maxwell and extend to the three dimensional problem for the method suggested by Chen. Especially, in the edge and corner parts except the planes, the APML method effectively treated as compound with the Chen's method and Gedney's method newly. The results of the numerical method in this paper show the radiation patterns and the time responses of electromagnetic fields of the wire antennas according to wavelengths and the APML results are compared with Mur's first order absorbing boundary condition and Kraus's analytical results. Eventually, Mur's first order condition have many errors at the edge and corner. On the other hand, in comparison with Kraus's analytical results, it is quite good agreement, and the validity of present method is confirmed.

  • PDF

Simulation of the High Frequency Hyperthermia for Tumor Treatment (종양치료용 고주파 열치료 인체적용 시뮬레이션)

  • Lee, Kang-Yeon;Jung, Byung-Geun;Kim, Ji-won;Park, Jeong-Suk;Jeong, Byeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.257-263
    • /
    • 2018
  • Hyperthermia supplies RF high-frequency energy above 1MHz to the tumor tissue through the electrodes. And the temperature of the tumor tissue is increased to $42^{\circ}C$ or more to cause thermal necrosis. A mathematical model can be derived a human body model for absorption and transmission of electromagnetic energy in the human model and It is possible to evaluate the distribution of temperature fields in biological tissues. In this paper, we build the human model based on the adult standard model of the geometric shape of the 3D model and use the FVM code. It is assumed that Joule heat is supplied to the anatomical model to simulate the magnetic field induced by the external electrode and the temperature distribution was analyzed for 0-1,200 seconds. As a result of the simulation, it was confirmed that the transferred energy progressively penetrates from the edge of the electrode to the pulmonary tumors and from the skin surface to the subcutaneous layer.

History and Archives : Colleagues or Strangers? (역사학과 기록학 학문의 인연, 학제의 괴리)

  • OH, Hang-Nyeong
    • The Korean Journal of Archival Studies
    • /
    • no.54
    • /
    • pp.179-210
    • /
    • 2017
  • By redefining the concept of history, my colleagues and I have reformed our department in terms of curriculum and faculty members. This paper is a report of some of the conclusions that we have obtained from this procedure. Despite a long relationship, two disciplines do not seem to match or complement each other in the Korean education system. We believe that this is due to the fact that the Department of Korean History has focused on "national history (NH)." By conferring a privilege on NH, persons, families, societies, regions, and others were removed from NH. To make matters worse, a biased view that history is just an interpretation has prevailed, and the empiricism of history was weakened, which brought about an indifference in keeping records and archives. In East Asia, "history" means both modern history and archives. The concern about the authenticity of records did not come from H. Jenkinson or L. Duranti, and not even from the electronic environment or the Public Records Act of 1998. Key concepts such as records, documents-archives, manuscripts, authenticity, compilation-appraisal, arrangement, and description are different from their signifiant but are same or similar to their $signifi{\acute{e}}$. In case of "provenance" and "original order," they are used in education and practice in the traditional archives. History includes the recording, archiving, and the story or historiography of an event. In this context, the Department of Korean History should contain a more archives-oriented curriculum and select an archival-trained faculty. On the other hand, the department has accumulated long-term experience with appraisal and description of records; thus, archival science should absorb the criticism of the material. History will be shaken without the help of archives, while archives will lose their root without history. We are at the point in which we need to be reminded why we want to be a historian or an archivist, and for this, the more colleagues, the better.

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

Dosimetry of the Low Fluence Fast Neutron Beams for Boron Neutron Capture Therapy (붕소-중성자 포획치료를 위한 미세 속중성자 선량 특성 연구)

  • Lee, Dong-Han;Ji, Young-Hoon;Lee, Dong-Hoon;Park, Hyun-Joo;Lee, Suk;Lee, Kyung-Hoo;Suh, So-Heigh;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Yu, Hyung-Jun;Gwak, Ho-Shin;Rhee, Chang-Hun
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.66-73
    • /
    • 2001
  • Purpose : For the research of Boron Neutron Capture Therapy (BNCT), fast neutrons generated from the MC-50 cyclotron with maximum energy of 34.4 MeV in Korea Cancer Center Hospital were moderated by 70 cm paraffin and then the dose characteristics were investigated. Using these results, we hope to establish the protocol about dose measurement of epi-thermal neutron, to make a basis of dose characteristic of epi-thermal neutron emitted from nuclear reactor, and to find feasibility about accelerator-based BNCT. Method and Materials : For measuring the absorbed dose and dose distribution of fast neutron beams, we used Unidos 10005 (PTW, Germany) electrometer and IC-17 (Far West, USA), IC-18, ElC-1 ion chambers manufactured by A-150 plastic and used IC-l7M ion chamber manufactured by magnesium for gamma dose. There chambers were flushed with tissue equivalent gas and argon gas and then the flow rate was S co per minute. Using Monte Carlo N-Particle (MCNP) code, transport program in mixed field with neutron, photon, electron, two dimensional dose and energy fluence distribution was calculated and there results were compared with measured results. Results : The absorbed dose of fast neutron beams was $6.47\times10^{-3}$ cGy per 1 MU at the 4 cm depth of the water phantom, which is assumed to be effective depth for BNCT. The magnitude of gamma contamination intermingled with fast neutron beams was $65.2{\pm}0.9\%$ at the same depth. In the dose distribution according to the depth of water, the neutron dose decreased linearly and the gamma dose decreased exponentially as the depth was deepened. The factor expressed energy level, $D_{20}/D_{10}$, of the total dose was 0.718. Conclusion : Through the direct measurement using the two ion chambers, which is made different wall materials, and computer calculation of isodose distribution using MCNP simulation method, we have found the dose characteristics of low fluence fast neutron beams. If the power supply and the target material, which generate high voltage and current, will be developed and gamma contamination was reduced by lead or bismuth, we think, it may be possible to accelerator-based BNCT.

  • PDF