• Title/Summary/Keyword: 3차원 인체 측정

Search Result 118, Processing Time 0.024 seconds

Preliminary Test of 3D Printed Plastic Scintillators for Proton Beam (3D 프린팅 플라스틱 섬광체의 양성자 빔에 대한 적용)

  • Sung-Hwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.681-686
    • /
    • 2022
  • In this study, a scintillation resin for 3D printing was fabricated with 1.0 wt% of PPO organic scintillator, 5.0 wt% of MMA, and commercial acrylic resin. Using the scintillation resin, 3D-shaped plastic scintillator radiation sensors were successfully fabricated quickly and inexpensively with a commercial 3D DLP printer. The 3D printed plastic scintillator has a good dose-output linearity of R-square 0.998 was obtained in the range of 1 to 10 nA of beam current of the 45 MeV proton beam. The developed 3D plastic scintillator has low light output, so there is a limit to its use in low-dose-rate gamma-ray or X-ray dosimetry. However, it was confirmed that the tissue equivalent material could be usefully used for measuring high energy or high dose rates radiation, such as proton beams and ultra-high dose rate beams.

The Study on an Using Effect of Head Mounted Display to the Body in Virtual Environments (가상환경에서의 HMD사용이 인체에 미치는 영향에 관한 연구)

  • 이창민;정진희
    • Journal of Korea Multimedia Society
    • /
    • v.3 no.4
    • /
    • pp.389-398
    • /
    • 2000
  • The focus of this study is to investigate how personal display system - Head Mounted Display(HMD) and VDU-affect to the body in virtual environments. This prediction was tested by a comparing of playing 3D games while wearing a HMD and monitoring a VDU for an hour. As quantitative measuring and analyzing tools, SSQ, RSSQ, pre and post posture stability test and vision test are used. The results showed that SSQ and RSSQ total score (TS) are related with the results of pre and post posture stability test and SSQ and RSSQ TS of HMD is higher than TS of VDU by one point five times. Especially, TS of MRG3C, having large field of view, has a possibility by two times of simulator sickness (SS). And in order to investigate the degree of SS regarding to the simulator control condition, two conditions, subjective-passive and subjective-active environments were compared. However, there was no significant difference between two environments. The repetition of the same environment has no effect to reduce the SS. Disorientation and oculomotor scores of the SSQ and RSSQ are higher than that of another symptoms. In addition, RSSQ score of strain/confusion is higher than that of nausea. Therefore, we assume that personal fear could possibly increase the simulator sickness in virtual environments.

  • PDF

Pyroelectric Infrared Microsensors Made for Human Body Detection (인체 감지용 강유전체 박막 초전형 적외선 센서의 제작)

  • Choi, Jun-Rim
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.103-110
    • /
    • 1998
  • Pyroelectric infrared detectors based on La-modified $PbTiO_{3}$ (PLT) thin films have been fabricated by RF magnetron sputtering and rnicrornachining technology. The detectors form $Pb_{l-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.05) thin film ferroelectric capacitors epitaxially grown by RF magnetron sputtering on Pt/MgO (100) substrate. The sputtered PLT thin film exhibits highly c-axis oriented crystal structure that no poling treatment for sensing applications is required. This is an essential factor to increase the yield for realization of an infrared image sensor. Micromachining technology is used to lower the thermal mass of the detector by giving maximum sensor efficiency. Polymide is coated on top of the sensing elements to support the fragile structure and the backside of the MgO substrate is selectively etched to reduce the heat loss. The sensing element exhibited a very high detectivity D* of $8.5{\times}10^{8}cm{\cdot}\sqrt{Hz}/W$ at room temperature and it is about 100 times higher than the case of micromachining technology is not used. A sensing system that detects the position as well as the existence of a human body is realized using the array sensor.

  • PDF

Brassiere Pattern Development Based on 3D Measurements of Upper Body - Focused on Women in Their 30's - (3차원 인체 계측 방법에 의한 상반신 체형을 고려한 브래지어 패턴 설계 - 30대를 대상으로 -)

  • Cho, Shin-Hyun;Kim, Mi-Sook
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.3
    • /
    • pp.488-501
    • /
    • 2008
  • The purpose of this study presents bra pattern using the 3D measurements of the upper body subject to women in their 30's. Brassieres available in the market are mostly designed for straight body shape and many women seem to have experienced bearing discomfort in a great extent as they grow older. Brassieres should be designed to cover diverse body types and the accurate measurement of body type and breast shape is needed to accomplish that. As for the study method, 3D human body types were analyzed with RapidForm 2006, and the upper-body types and breast shapes were statistically classified through technical statistics analysis, cluster analysis, t-test, variance analysis, and cross analysis. The wearing tests went through the comparison of the brassieres of three makers in the market and the experiment brassieres(first and second) and then the evaluations were made by the subjects, the outer appearance assessment by experts, and 3D measurements. The results of this study showed that the evaluation of experiment brassieres was excellent in every item, and the significant difference was found out particularly in the items of pressure, rear center, front center, breast underneath, adequate level by wing, and adequate level by armhole. According to the results of 3D evaluation, experiment brassieres had a highest point in fitness with no physical pressure at the wing part and no overall deviation at the cup part.

  • PDF

Scintillation Properties of Acrylate Based Plastic Scintillator by Photoploymerization Method (아크릴레이트 기반 광중합 플라스틱 섬광체의 섬광 특성)

  • Kim, Sunghwan;Lee, JoonIl
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.637-642
    • /
    • 2016
  • In this study, we prepared and characterized a acrylate based UV-curable plastic scintillator. It was used co-polymers TMPTA, DHPA and Ultima $Gold^{TM}$ LLT organic scintillator. The emission spectrum of the plastic scintillator was located in the range of 380~520 nm, peaking at 423 nm. And the scintillator is more than 50% transparent in the range of 400~800 nm. The emission spectrum is well match to the quantum efficiency of photo-multiplier tube and the fast decay time of the scintillation is 12 ns, approximately. This scintillation material provides the possibility of combining 3D printing technology, and then the applications of the plastic scintillator may be expected in human dosimetry etc.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

A Study on the Body Characteristics of High School Boys According to Their Drop Types (남자 고등학생의 드롭별 인체 특성에 관한 연구)

  • Hyun, Eun-Kyong;Nam, Yun-Ja
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.8
    • /
    • pp.1233-1241
    • /
    • 2010
  • This study analyzes the body characteristics of high school boys according to 3 different body types in order to improve the fit of upper garments. First, among the lateral body types, the straight body type was selected from the SizeKorea 3D scanned data and 2D measurement data. Second, high school boys (classified as straight lateral body type) were grouped into type B, A, and Y drop groups. The percentages of type B, type A, type Y are 17.8%, 48.1%, 32.1% respectively. The characteristics of the body types were analyzed. While the bust circumference were the same among the three body types (chest width, back width, back across shoulder, and bust width did not show a significant difference); however, waist and hip measurements showed a significant difference among the three body types. Third, the height of the high school boys ranged between 165cm and 180cm and the bust circumference between 85cm and 97cm. For the bust size categories, type B and type Y are distributed similarly; however, type A is distributed in the smaller bust size categories.

An Exploratory Study of Searching Human Body Segments for Motion Sensors of Smart Sportswear: Focusing on Rowing Motion (동작에 따른 피부변화 분석을 통한 동작센서 부착의 최적위치 탐색: 조정 동작을 중심으로)

  • Han, Bo-Ram;Park, Seonhyung;Cho, Hyun-Seung;Kang, Bokku;Kim, Jin-Sun;Lee, Joohyeon;Kim, Han Sung;Lee, Hae-Dong
    • Science of Emotion and Sensibility
    • /
    • v.20 no.1
    • /
    • pp.17-30
    • /
    • 2017
  • Lots of interdisciplinary studies for fusion of high technologes and the other areas of research had been tried in these days. In sports training area, high technologies like a vital sign sensor or an accelerometer were adopted as training tools to improve the performance of the sports players. The purpose of this study is finding the proper locations on the human body for attaching the motion sensors in order to develop a smart sportswear which could be helpful in training players. The rowing was selected as a subject sport as lots of movements of the joint on human body could be seen in rowing motions. The players of rowing could be devided into two weight divisions, the lightweight and the heavyweight. In this study, the change rates of distance between markers on human skin as the players moved were took on the back, the elbow, the hip and the knee area on human body by 3D motion capturing system. The distances between markers and the differences between the lightweight and heavyweight were analyzed. Finally, this study provided the guide lines for designing a motion sensing smart sportswear.

A Study on the Application of 3D Virtual Human in the prior stage of Design Works - With the emphasis on the determining design layout of a forklift truck (디자인 초기단계에서의 3차원 가상인간(Virtual Human) 활용에 관한 연구 - 지게차 레이아웃 결정 단계를 중심으로)

  • 김관명
    • Archives of design research
    • /
    • v.12 no.4
    • /
    • pp.294-303
    • /
    • 1999
  • With the breakthrough development of computing environment, the design phases have been changed a lot nowadays. In the case of prior phases of transportation design such as cars and forklift-trucks design, designers have depended on surveys and 2D line drawings for fixing a product layout and extracting ergonomic data. In this method, designers don't meet only the problem of reliability of measuring data but also, the problems of unknown situation of operators' fatigue and comfort in work situation. In these methods, it has much less creditability to have a 2D human model to check the real world motion due to the limitation of the 3 Dimension. Even though with a 2D human model, perfect layout is determined, it is still difficult to measure about comfort and fatigue for a user because it measuring an analysing method is static. The development of computer hardware and software have not only changed the flow in the social-wide range but also immerged design into Virtual Environment. In conventional design method, visualization and data transferring have been the main issues but, in virtual environment, determining of design layout and analysing ergonomic data with sophisticated feeling about comfort and fatigue are possible by using 3D virtual human. In this study, the general characteristics of virtual environment was discussed and the possibility of digital process of design was treated. For these studies, layout design for forklift-trucks was tested. Eventually, the merits of each design phase applied virtual environment are discussed.

  • PDF

Geometry and Property Database for Korean Spine Research (한국인 척추 연구를 위한 형상 / 물성 정보 구축)

  • Lee, Seung-Bock;Lee, Sang-Ho;Han, Seung-Ho;Kwak, Dai-Soon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.10
    • /
    • pp.488-493
    • /
    • 2011
  • The Korean spine geometry and property data for researchers were made by KISTI and Catholic Institute for Applied Anatomy. We took whole spine CT, X-Ray, BMD scan for making high resolution cross-sectional spine images using more 20 donated cadavers(60 - 80 years). Then we constructed 3-dimensional volume model using serial CT images by Mimics software. The major morphometric parameters of vertebrae were measured. Mechanical motion and property data were obtained by the same cadavers using the DEXA for BMD and the spine simulator. The Korean spine geometry and property data could be used for research and development of medical device.