• Title/Summary/Keyword: 3차원 인체측정

Search Result 118, Processing Time 0.024 seconds

The Classification of Elderly Men's Feet - With the Three-dimensional Body Scanner Data of Size Korea - (노년 남성의 발 유형 분류 -Size Korea의 3차원 측정 데이터를 이용하여-)

  • Seok, Hye-Jung;Park, Ji-Eun
    • Journal of the Korean Society of Costume
    • /
    • v.57 no.10
    • /
    • pp.50-59
    • /
    • 2007
  • This study has been conducted to classify elderly men's feet with the three-dimensional body scanner data of Size Korea. It was intended to assist the manufacturing of the shoes that can appropriately perform the functions of feet, by providing the specific information about the shapes of elderly men's feet that are altered as a result of aging and shoe-wearing for a long time. The findings are as follows. 1. The investigations into the average and standard deviation of the measurements and index values for the elderly men's feet showed a large personal difference in the items of length and circumference. 2. The factors constituting the elderly men's feet were observed to be the size of foot width(Factor 1), the central angle of feet and the extension of toes(Factor 2), the size of ankle(Factor 3), the positions of lateral malleolus and pternion(Factor 4), and the position and size of medial malleolus(Factor 5). 3. The cluster analysis for the classification of elderly men's feet produced three types of them.

An Efficient Method for Modeling a Standard Tooth (표준 치아를 모델링하기 위한 효율적인 방법)

  • Jang, Jin-Ho;Kim, Byung-Oh;Yoo, Kwan-Hee
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.1221-1224
    • /
    • 2001
  • 최근 몇 년간 의학 분야에서는 인체의 해부학적 조직을 컴퓨터 그래픽스 기술을 이용해 재구성하는데 관심이 증대되어 왔다. 치과 치료분야에서도 컴퓨터 그래픽스 기술에 대한 관심이 증대되고 있고, 이를 이용한 다양한 치료법들이 개발되고 있다. 자료를 측정한다거나, 시각적으로 3차원의 영상을 보여 줄 수도 있다 또한, CAD-CAM 기술을 이용하여 의치의 틀이나 금형 등을 직접 제작할 수도 있다. 본 논문에서는, 이러한 컴퓨터 그래픽스 기술을 이용한 치과 치료에 기념이라 할 수 있는 표준 치아에 대한 모델링 데이터를 만들고자한다. 그러기 위해 표준치아의 실제 모델을 3차원 스캐너로 입력받는다. 그리고 입력받는 과정에서 발생하는 오류를 수정하여, 정확한 표준 치아 모델을 모델링한다.

  • PDF

A numerical study on dimple shapes over a circular cylinder (원형 실린더 표면의 딤플 형상에 대한 수치 해석적 연구)

  • Lee, Hyeok;Kim, Ik-Hyeon;Sa, Jeong-Hwan;Park, Su-Hyeong;Byeon, Yeong-Hwan
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.585-590
    • /
    • 2014
  • Chowdbury. H.는 인체를 다수의 원형 실린더로 단순화하여 스키점프와 사이클 운동복의 항력계수를 각각 측정하였다. 이처럼 원형 실린더에 스피드 스케이팅 운동복을 씌운 모습과 골프공에서 사용하는 딤플의 2차원 형상이 서로 유사한 모양임을 착안하여, 2차원 원형 실린더 표면의 딤플이 유동 현상에 어떤 효과를 일으키는지 살펴보았다. 본 연구에서는 초기 형상을 토대로 3가지 딤플 형상 변수에 대한 매개변수 설정을 통해 항력계수를 비교하였다. 또한 3가지 딤플 형상 중 가장 낮은 항력계수를 갖는 딤플 형상에 대해서 요철 높이에 따른 항력계수를 비교하였다. 이를 통하여 딤플 형상이 각진 모양보다 둥근 모양일수록 항력계수가 작은 것을 확인하였으며, 요철 높이를 제외한 모든 조건이 동일할 때 최적의 요철 높이가 존재할 수 있음을 확인하였다.

  • PDF

Registration System of 3D Footwear data by Foot Movements (발의 움직임 추적에 의한 3차원 신발모델 정합 시스템)

  • Jung, Da-Un;Seo, Yung-Ho;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.6
    • /
    • pp.24-34
    • /
    • 2007
  • Application systems that easy to access a information have been developed by IT growth and a human life variation. In this paper, we propose a application system to register a 3D footwear model using a monocular camera. In General, a human motion analysis research to body movement. However, this system research a new method to use a foot movement. This paper present a system process and show experiment results. For projection to 2D foot plane from 3D shoe model data, we construct processes that a foot tracking, a projection expression and pose estimation process. This system divide from a 2D image analysis and a 3D pose estimation. First, for a foot tracking, we propose a method that find fixing point by a foot characteristic, and propose a geometric expression to relate 2D coordinate and 3D coordinate to use a monocular camera without a camera calibration. We make a application system, and measure distance error. Then, we confirmed a registration very well.

The Verification of Accuracy of 3D Body Scan Data - Focused on the Cyberware WB4 Whole Body Scanner - (3차원 인체 스캔 데이터의 정확도 검증에 관한 연구 - Cyberware의 WB4 스캐너를 중심으로 -)

  • Park, Sun-Mi;Nam, Yun-Ja
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.14 no.1
    • /
    • pp.81-96
    • /
    • 2012
  • The purpose of this study is to provide fundamental information for standardization of 3D body measurement. This research analyzes errors occurring in the process of extracting body size from 3D body scan data. First, as a result of analyzing basic state of the 3D body scanner's calibration, the point number of each section was almost the same, while the right and left as well as the front and back coordinates of the center of gravity are not, showing unstable data. Nevertheless, the latter does not influence on the size of cylinder such as width and circumference. Next, we analyzed point coordinates variations of scan data on a mannequin nude by life casting. The result was great deflection in case of complicated or horizontal sections including the reference point beyond proper distance from centers of four cameras. In case of the mannequin's size, accuracy proves comparatively high in that measurement errors in height, width, depth, and length dimension occurred all within allowable errors, only except chest depth, while there were a lot of measurement errors in a circumference dimension. Secondly, analysis of accuracy of automatic extraction identification program algorithm presented that a semi-automatic measurement program is better than an automatic measurement program. While both of them ate very acute in parts related to crotch, they are not in armpit related parts. Therefore, in extracting of human body size from 3D scan data, what really matters seems to parts related to armpits.

  • PDF

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Classification of Middle Aged Women's Breast Shapes Using 3D Body Measurement Data (3차원 인체 측정치들을 이용한 중년 여성의 유방 형태에 따른 유형)

  • Lee, Hyun-Young;Hong, Kyung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.3
    • /
    • pp.385-392
    • /
    • 2010
  • The breast types of middle-aged women of 80A (formerly 80B) size were classified through a 3D scanned nude body. Thirty seven measurements including the radius of curvature, surface area, volume, surface length, and breast displacements were used as input variables. We extracted five main factors through the factor analysis of the measurements and classified 36 subjects into 3 clusters through the cluster analysis. As a result of the factor analysis, the size of the breast, breast sag, the curvature of the inner and the outer breast curve, the width of the breast, and the nipple direction were found as the main factors. For the results of the classification of breast types, Cluster 1 was characterized by narrow breast width and unsymmetrical under the breast curve, whereas Cluster 2 was a wide and sagged shape. Cluster 3 was classified into big breast volume and symmetrical under-breast curve. The results are useful to the product development of high quality brassieres which reflect the 3D characteristics of breast types of middle-aged women.

Body Size Changes Characteristics of Elementary School Girls Using 3D Body Scan Data (3차원 인체형상을 이용한 학령기 여아의 신체 치수 변화 특성)

  • Jang, Ja-Moon
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.13 no.4
    • /
    • pp.79-91
    • /
    • 2011
  • This study divided school age by considering a change in the stage of body growth by age in elementary schoolgirls with the use of body scan data, and considered by comparing body size characteristics by school age. Elementary schoolgirls' body shape cannot be divided clearly. However, ages 7-10 were bound into the same group for the majority of girth, width, and thickness items. 7-8 years old, 9-10 years old, and 11-12 years old were bound into the same group in most items except ages 9 and 10 for the height item. Thus, significant difference was indicated between groups. Accordingly, this study divided the school age into three periods such as early stage(ages 7-8), middle stage(ages 9-10), and late stage(ages 11-12) in consideration of the stages for elementary schoolgirls' body-shape growth. As a result of analyzing body size according to division of school age, the higher school age leads to continuous growth. The notable growth was indicated especially in the middle stage and late stage. Examining centering on typical items related to the clothing construction, there was notable increase in waist thickness and hip thickness between early and middle stages and in height, weight, breast girth, waist circumference, back length, breast width, and waist width between middle and late stages. On the other hand, hip circumference, hip width, breast thickness, and length between shoulder edges were indicated to grow relatively and evenly among early, middle, and late stages. The lateral form was shown a clear difference in the forms of early, middle, and late stages in height and length of the whole body shape and in side thickness. The early and middle stages belong to body shape that abdomen is projected to be curved. The late stage showed right body shape which is straight and stable form in posture.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

3-Amino Propane Phosphoric Acid (3-APPA) : A Novel Anti-Aging Substance (3-Amino Propane Phosphoric Acid (3-APPA) : 새로운 피부 노화 억제 물질)

  • 조윤기;변영훈;선보경;황재성;이보섭;김종일
    • Proceedings of the SCSK Conference
    • /
    • 1996.07a
    • /
    • pp.52-67
    • /
    • 1996
  • 새로운 노화방지 물질로 개발한 3-APPA가 노화에 의해 야기되는 여러 변화들, 특히 세포 증식, 유전자 수준 및 단백질 수준에서의 collagen의 생합성 변화, 면역조직화학염색을 이용한 collagen 생합성의 변화등을 세포배양 및 동물실험을 통하여 측정하였다. MTT assay를 이용한 인체 피부 섬유아세포의 증식 실험에서 3-APPA는 무처치군에 비교해서 최고 2배의 섬유아세포 증식 효능을 나타내었으며, $^3$[H]-proline incorporation 방법을 이용한 단층세포 배양 및 3차원 dermal equivalent 섬유아세포 배양에서 무처치군 및 vitamin C 처리군에 비해 최고 1.5배의 collagen 생합성 증가를 나타내었다. 그러나 type I alpha-procollagen mRNA expression에는 영향을 미치지 않는 것으로 나타났다. H&E 염색을 이용한 hairless mice의 피부에 대한 형태학적 변화 및 type I pM procollagen antibody를 이용한 면역조직화학염색에서, 3-APPA는 collagen 생합성을 증가시키는 것으로 나타났다. 이상의 결과에서 3-APPA는 섬유아세포 배양 및 hairless mouse를 이용한 실험에서 피부 섬유아세포 증식을 촉진시키며 collagen 생합성을 증가시켜 피부노화를 억제 할 수 있는 물질임을 밝혔다.

  • PDF