• Title/Summary/Keyword: 3차원 인체측정

검색결과 118건 처리시간 0.029초

직접측정과 3차원 측정에 따른 인체치수 및 의복 착장 비교분석 (Comparative Analysis of Body Measurement and Fit Evaluation between 2D Direct Body Measuring and 3D Body Scan Measuring)

  • ;임호선;천종숙
    • 복식문화연구
    • /
    • 제19권6호
    • /
    • pp.1347-1358
    • /
    • 2011
  • This study purposed to analyze differences in body measurement between the 2D direct body measuring method and the 3D body scan measuring method and to perform the appearance evaluation and cross-sectional evaluation of the fit of pants to which body measurements obtained by each measuring method were applied. Body measuring was conducted in 10 women in their 20s-30s using 2D direct body measuring and 3D automatic measuring with Hamamatsu body scanner. Among the 10 women, 3 participated in experimental garment wearing. Experimental pants were made using their 2D direct body measurements and 3D automatic measurements, and wearing tests were performed through expert evaluation and cross-sectional evaluation. The results of the experiment were as follows. According to the results of comparative analysis on differences between 2D direct body measurements and 3D scan measurements, 3D automatic measurements were significantly larger in bust circumference, ankle circumference, armscye circumference, shoulder length, scye depth, and arm length. As circumferences measured with the 3D body scanner were somewhat larger than directly measured ones, it is suggested to adjust ease when using existing pattern making methods. We prepared experimental garments by the same pattern making method through applying body measurements obtained with the two measuring methods, and assessed the fit of the garment comparatively through expert evaluation and 3D scan cross-sectional evaluation. According to the results, 2D-pants using 2D direct body measurements was slightly tighter than 3D-pants using 3D measurements in waist circumference, hip circumference, and abdominal circumference. In the results of comparing appearance in terms of the fit of the experimental garment in each subject, significant difference was observed in most of the compared items. This result suggests that 3D automatic body measuring data may show different accuracy according to body shape and therefore it is necessary to examine difference between 2D direct body measurements and 3D automatic measurements according to body shape.

인체동작 인식을 위한 마커리스 트래킹 시스템 (Makerless Tracking System for Motion Capture of Human Organism)

  • 안세종;신성욱;이현숙;임창주;박영진;정성택
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 추계학술논문집 1부
    • /
    • pp.241-243
    • /
    • 2011
  • 인체동작 인식에 대한 연구는 재활치료, 운동선수의 동작 교정 및 모니터링, 3차원 애니메이션 제작등 많은 분야에서 필요로 하고 있다. 동작 인식에 대한 일반적인 방법으로는 반사 마커를 부착하여 여러 대의 적외선 카메라로 관절 운동을 관찰하는 방식이였다. 이러한 방식은 여러 개의 마커를 사용자들이 옷을 벗고 몸에 붙이거나 특수 복장을 착용해야 하는 불편함이 있을 뿐만 아니라 초기 위치 보정에도 많은 시간이 소모된다. 이와 같은 문제점을 해결하기 위하여 본 연구에서는 어떠한 특수 장비를 착용하거나 몸에 부착하지 않고 즉각적으로 인체의 움직임을 트래킹 할 수 있는 마커리스 트래킹시스템을 개발하였다. 이 시스템은 사람의 동작 분석을 하는데 있어 빠르게 측정 및 분석이 가능하고 특수 장비를 착용하지 않아도 됨으로 인해 동작에 방해를 받지 않아서 3차원 영상을 즉각적으로 확인할 수 있는 편리성을 갖추고 있다.

  • PDF

인체팬톰을 이용한 2D-3D 정합시 타켓위치의 정확성 평가 (Evaluation of Target Position's Accuracy in 2D-3D Matching using Rando Phantom)

  • 장은성;강수만;이철수
    • 대한방사선치료학회지
    • /
    • 제21권1호
    • /
    • pp.33-39
    • /
    • 2009
  • 목 적: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하면 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. Detected offsets은 실제로 적용된 인체팬톰(Rando phantom) 위치의 오차와 비교되어 진다. 이후, 인체 팬톰은 detected 오차에 근거하여 couch를 움직여 위치선정 되었다. 또한 인체팬톰 위치 결정의 실측값과 이론값 오차값들을 비교하였으며, OBI를 사용하고 있는 KV X선영상의 2D와 CBCT의 3D 타켓 위치 정확성 평가하고자 한다. 대상 및 방법: 신체 내부 구조가 모사된 팬톰(The Rando Phantom, Alderson Resarch Laboratories Inc. Stamford. CT, USA)을 사용하여 실제방사선 치료와 동일한 과정을 따라 모의치료(SIMULATION) 및 치료계획(RTP)을 시행한 후 치료 데이블 위에 인체 팬톰을 셋업한다. 정확히 위치가 재현된다고 가정되는 인체팬톰에 대해 3가지 방법으로 실험을 했는데 X, Y, Z축의 변화에 따라 셋업 오차를 측정했고 각각의 실험은 10회씩 반복되어 오차의 표준 편차를 구했다. DigiPas DWL-80G는 기울기의 각을 결정하기 위해 사용하였으며, 2D/2D 및 3D/3D정합의 실측치와 측정치를 비교 분석 하였다. 결 과: 온보드 영상장치로 획득한 정면 및 측면 kv x선 영상과 모의치료시 디지털 재구성 기준영상과의 2차원/2차원 정합시, 팬톰의 X, Y, Z 편차 평균값은 lat 0.12 cm, long -0.66 cm, vert 0.07 cm이며, 각도의 변화를 주었을 때 편차의 평균값은 lat -0.5 cm, long -0.3 cm, 팬톰의 몸을 약간 튼 상태에서의 편차 평균값은 각각 lat -0.5 cm, long 0.2 cm, vert -0.6 cm으로 나타났다. 또한 콘빔CT로 획득한 영상과 모의치료 시 획득한 CT영상을 비교하는 3차원/3차원 정합에서 팬톰의 3가지 방법에서 편차의 평균 detection error와 표준편차는 lateral $0.5{\pm}0.4\;mm$, longitudinal $0.8{\pm}0.5\;mm$, vertical $0.4{\pm}0.3\;mm$로 각각 0-10 mm의 범위이다. Residual error에 해당되는 positioning couch shift 변수는 $0.6{\pm}0.3\;mm$, $0.5{\pm}0.3\;mm$, $0.3{\pm}0.1\;mm$이다. 20-50 mm까지 longitudinal shift에 의한 평균 detection error는 각각 lateral $0.4{\pm}0.2\;mm$, longitudinal $0.3{\pm}0.2\;mm$, vertical $0.3{\pm}0.3\;mm$이다. Residual error는 $0.6{\pm}0.3\;mm$, $0.6{\pm}0.2\;mm$, $0.4{\pm}0.1\;mm$이다. Detection error는 모두 0.0~0.6 mm 범위이다. Residual error는 0.3~0.9 mm 범위로 나타났다. 결 론: 온보드 영상장치(OBI) 및 콘빔 CT (CBCT)를 이용하여 표적위치의 정확성을 평가하였다. 치료실에 위치한 환자의 자세 및 위치와 모의치료(SIMULATION) 시점의 환자의 자세 및 위치를 비교할 수 있다. 그러므로 OBI 및 CBCT를 이용한 2D/2D 및 3D/3D 정합은 모의 치료 시와 환자 치료 시 정확한 정합을 함으로써 error를 최소화 할 것으로 평가된다.

  • PDF

단일 카메라를 이용한 동역학 기반의 보행 동작 추적 (Tracking a Walking Motion Based on Dynamics Using a Monocular Camera)

  • 유태근;최재림;김덕원
    • 전자공학회논문지SC
    • /
    • 제49권1호
    • /
    • pp.20-28
    • /
    • 2012
  • 보행을 관찰하고 객관적인 정보를 추출하여 그 기능을 평가하는 것을 보행 분석이라고 한다. 최근 사용되는 보행 측정 장비들은 다수의 카메라, 지면 반력 측정 장치로 구성되어 고가이며, 이를 설치할 넓은 장소를 필요로 한다는 단점이 있다. 본 연구에서는 이러한 문제점을 해결하기 위해 단일 카메라를 통해 얻은 영상에서 마커 없이 인체의 3차원 보행 동작을 측정하는 기법을 제안한다. 파티클 필터를 사용하여 훈련 데이터와 보행에 관한 사전 정보 없이 사람의 동작을 추적한다. 인체와 지면에 관한 동역학을 통해 물리적으로 합당한 인체의 동작들을 생성하였다. 보행 영상에서 계산한 모든 관절의 평균 에러는 제안한 방법에서 $12.4^{\circ}$로, 기존 파티클 필터의 에러 $34.6^{\circ}$보다 작았다. 이러한 결과를 바탕으로 단일 카메라만으로 보행을 정량적으로 측정하여 기존 복잡한 장비를 대체할 수 있는 가능성을 제시하였다.

인체형상 측정을 위한 가상격자 영사식 무아레 방법에 관한 연구 (A Study on the Virtual Grating Projection Moire Topography for the Shape Measurement of Human Face)

  • 유원재;최정표;안중근;강영준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2001
  • Moire topography method is a well-known non-contacting 3-D measurement method. Recently, the automatic 3-D measurement by moire topography has been required since the method was frequently applied to the engineering and medical fields. 3-D measurement using projection moire topogrphy is very attractive because of it s high measuring speed and high sensitivity. In this paper, using two-wavelength method of projection moire topography tested to measuring object with the $2\pi$-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding absolute fringe orders, so that the $2\pi$-ambiguity problem can be effectively overcome so as to treat large step discontinuities in measured objects.

  • PDF

3차원 인체 측정을 이용한 청소년기 여성의 유방 발육 변화 추이 및 특성 연구 - 만 13~18세를 중심으로 - (A study on the variation trends and characteristics of the adolescent girls' breast growth based on 3D body measurements - Focused on the ages from 13 to 18 -)

  • 최소영;천종숙
    • 복식문화연구
    • /
    • 제22권6호
    • /
    • pp.943-954
    • /
    • 2014
  • The purpose of this study was to analyze the breast growth variation trends and characteristics of Korean adolescent girls based on 3D body measurements. Subjects were 174 girls aged between 13 and 18. 3D body scanning data were collected and the data were measured by Geomagic Design X program. The total of 18 anthropometric measurements and 4 index items were analyzed. The main results of this study are as follows: 1) Overall, the breast growth of adolescent girls got out of children's body shapes at the age of 14 and the adult's body shapes appeared remarkably at the age of 18. Before the age of 15, the adolescent girls' breast enlarged. 2) The surface lengths of upper body, which means the breast volume, showed significant growth above B cup groups rather than under A cup groups. The demand of B cup size (32.2%) was higher than A cup size (25.9%). And 35.6% of subjects' brassiere band size was 70. 3) The thorax grew evenly in the circumference, depth and breadth. The thoracic development related to the breast volume as well as the whole upper body's development. These results reveal that it is necessary to develop adolescent girls' brassiere reflecting on adolescent girls' breast growth variation trends and characteristics by age, breast size and thoracic development.

보행의 운동학적 데이터를 이용한 지면반발력 계산 (Computation of Ground Reaction Forces During Gait using Kinematic Data)

  • 송성재;김세윤;김영태;이상돈
    • 대한기계학회논문집A
    • /
    • 제34권4호
    • /
    • pp.431-437
    • /
    • 2010
  • 본 연구의 목적은 편마비 환자와 같이 정상 보행이 아닌 경우의 보행 실험에서 힘측정판을 이용한 지면반발력의 측정이 매우 어려웠던 경험에서 출발하여 힘측정판을 사용하지 않고 운동학적 데이터만으로 보행 중 발생하는 지면반발력을 계산하는 것이다. 3차원 동작분석 시스템과 동기화된 힘측정판을 이용하여 보행실험을 실시하여 3차원 동작분석 시스템으로부터 보행의 운동학적 데이터를 추출하였고 이로부터 보행주기를 검출하였다. 인체를 13개의 체절로 모델링하고 각 체절의 거동이 추출한 운동학적 데이터를 따르도록 하였다. 각 체절의 질량과 질량 중심은 인체측정학의 자료를 이용하였다. 보행실험에서 측정한 지면반발력과 운동학적 데이터만을 이용한 계산 결과의 비교에서 크기가 가장 큰 수직방향은 잘 일치하였고 전후방향이나 횡방향도 유사한 경향을 보였다. 본 계산 결과는 보행에 관한 역동역학 해석의 기본 자료로 활용할 수 있다.

치아의 기하학적 특성 찾기 (Finding the Geometric Features of a Tooth)

  • 장진호;김병오;유관희
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2001년도 봄 학술발표논문집 Vol.28 No.1 (B)
    • /
    • pp.619-621
    • /
    • 2001
  • 최근 몇 년간 의학 분야에서는 인체의 해부학적 구조를 컴퓨터 그래픽스 기술을 통해 컴퓨터로 재구성하려는 시도에 많은 관심을 쏟아졌다. 이러한 관심은 치과 치료분야에서도 이루어져 왔는데, 컴퓨터 그래픽스르 이용한 치과 치료에도 많은 응용 분야가 있다. 자료를 측정한다거나, 시각적으로 3차원의 영상을 보여준다거나, CAD-CAM 기술을 이용하여 의치의 틀이나 금형등을 제작할 수도 있다. 본 논문은 이러한 다양한 응용에 기반 기술이 될 수 있는 치아의 기하학적 특성을 정의 하고, 이것을 찾기 위한 여러 가지 방법을 실험해보고, 더 나은 방법을 제시하고자 한다.

  • PDF

2.5D 전자선 선량계산 알고리즘 개발 (Development of 2.5D Electron Dose Calculation Algorithm)

  • 조병철;고영은;오도훈;배훈식
    • 한국의학물리학회지:의학물리
    • /
    • 제10권3호
    • /
    • pp.133-140
    • /
    • 1999
  • 본 연구에서는 외부조사 전자선에 대한 3 차원 선량계산 알고리즘 모델을 개발하기 위한 기초연구로서 기존의 2D 펜실빔 알고리즘을 확장시켜 3 차원 geometry를 적절히 고려할 수 있는 선량계산 모델을 개발하고자 한다. 선량계산 모듈은 IDL5.2(Reseach Systems Inc. 미국)를 사용하여 프로그램하였으며, Hogstrom의 펜실빔 모델에 의한 선량계산에 필요한 중심축 상의 깊이선량분포는 Siemens M6740의 12MeV 전자선에 대한 측정치를 사용하였고, 전자선의 공기 및 불에서의 선형저지능 (linear stopping power), 선형산란능 (linear scattering power) 은 ICRU 보고서 35로부터 인용하여 사용하였다. 선량계산의 정확도를 확인하기 위하여 정형 조사면에 대한 선량분포 공기 간격 효과 인체 외곽 보정에 대해 전리함, 필름 등을 사용하여 얻은 측정값과 비교, 분석하였다. PC(Pentium III 450MHz) 상에서 프로그램 실행 결과 단일 조사 빔에 대한 선량계산에 약 120초가 소요되어, 선량계산 알고리즘의 최적화를 통한 선량계산 시간 단축이 필요하다 하겠다. 선량 평가에 대한 비교 결과, 정형 및 비정형 조사변에 대한 선량분포는 선량변화가 급격한 반음영 (penumbra) 영역에서 $\pm$3mm 이내의 오차를 보였으며, 측방 선량분포에 따른 비교 결과, 측정치와 5% 이내에서 일치하였다. 또한 공기 간격 및 인체 외곽선 보정의 경우, $\pm$10% 내외에서 측정값과 일치하였다. 결론적으로, 전자선에 대한 2 차원 펜실빔 모델을 확장하여 3 차원 치료계획에 적합하게 3 차원상의 임의의 단변 선량계산이 가능하도록 구현되었다. 또한 비정형 조사변에 대한 선량계산 뿐만 아니라, 인체외곽 및 공기 간격 등과 같이 3 차원적 geometry에 대한 보정이 필요한 경우에 대하여도 이를 선량계산 시 적절히 고려함을 확인할 수 있었다. 추후, CT를 통한 비균질 보정방식을 구현할 계획이며, 이들 선량계산 모듈은 교육 및 연구용으로 적절히 활용할 수 있을 것으로 기대된다.

  • PDF

장갑의 적합성 향상을 위한 손부위 2차원 계측정보 DB구축에 관한 연구 -성인 남.녀 만 18세에서 만 64세를 중심으로- (The Database Development of 2-D Hands Measurement for Improving Fitness of gloves -focused on the ages from 18 to 64 of male & female adults-)

  • 최혜선;김은경
    • 한국의류학회지
    • /
    • 제28권3_4호
    • /
    • pp.509-520
    • /
    • 2004
  • The aim of this study was to provide the basic 2-dimensional statistics requisite in the siting system and design of gloves. The 64 static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. Subjects were divided into four age groups: 18 to 29, 30 to 39, 40 to 49, and 50 to 64, and separated according to sex. Statistical tests such as Descriptive Analysis, and Anova were conducted to analyze the data and ascertain the differences among the ages. The disparities between sex groups were compared by T-test. In addition, correlation among the 57 measurements was analyzed and the results were compared to the data from Japanese and other studies. The results indicated that all the measurements were significantly larger in the male group. There were significant differences among age groups for most hand circumferences, breadths and thickness items. As the age increased, the hand circumferences, breadths and thickness items became wider and thicker. In addition, as the age increased, the mean measurement value of the length items decreased, so that it became shorter. Hand length was highly correlated with finger length, palm length and height. Maximum hand circumference II was highly correlated with hand circumferences, hand breadth and weight.