In the present study, the analysis on heat and fluid flow in the single screw extruder is carried out by simultaneously considering the metering section and the die. The finite difference method and the finite volume method are applied to the metering section and the die, respectively. The zonal method is used to couple the metering section and the die. To investigate the effect of die on the characteristics of heat and fluid flow in the single screw extruder, the pressure back flow is included in the analysis. The screw-tip rotation is also considered by employing the quasi 3-dimensional die model. The present results are compared with the numerical and experimental data available in the literatures.
Journal of the Korean Society of Propulsion Engineers
/
v.19
no.1
/
pp.9-17
/
2015
The basic flow configuration is composed of a plane, double shear layer where relatively thin mid gas layer is sandwiched between air and fuel stream. The present study describes numerical investigations concerning the combustion enhancement according to a variation of mid layer thickness. In this case, the effect of heat release in turbulent mixing layers is important. For the numerical solution, a fully conservative unsteady $2^{nd}$ order time accurate sub-iteration method and $2^{nd}$ order TVD scheme are used with the finite volume method including k-${\omega}$ SST model. The results consists of three categories; single shear layer consists of fuel and air, inert gas sandwiched between fuel and air, cold fuel gas sandwiched between fuel and air. The numerical calculations has been carried out in case of 1, 2, 4 mm of mid layer thickness. The height of total gas stream is 4 cm. The combustion region is broadened in case of inert gas layer of 2, 4 mm thickness and cold fuel layer of 4 mm thickness compared with single shear layer.
Park, Ji-Young;Suh, Ji-Hyun;Kim, Sung-Hee;Kim, Myoung-Hee
한국HCI학회:학술대회논문집
/
2008.02a
/
pp.813-816
/
2008
In this research we present a method to reconstruct the casting flow simulation result as a 3D model and visualize it on a VR display. First, numerical analysis of heat flow is performed using an existing commercial CAE simulation software. In this process the shape of the original design model is approximated to a regular rectangular grid. The filling ratio and temperature of each voxel are recorded iteratively by predefined number of steps starting from pouring the melted metal into a mold until it is entirely filled. Next we reconstruct the casting by voxels using the simulation result as an input. The color of voxel is determined by mapping the colors to temperature and filling ratio at each step as the flow proceeds. The reconstructed model is visualized on the Projection Table which is one of horizontal-type VR display. It provides active stereoscopic images.
Transactions of the Korean Society of Mechanical Engineers B
/
v.37
no.10
/
pp.941-951
/
2013
A three dimensional numerical simulation of laminar flow and heat transfer in fully developed curved pipe flow has been performed to study the effects of Dean number and pipe curvature on the flow and temperature fields under the thermal boundary condition of axially uniform wall heat flux. The Reynolds number under consideration ranges from 100 to 4000, and the Prandtl number is 0.71. The curvature ratios are 0.01, 0.025, 0.05 and 0.1. The axial velocity and temperature profiles and the local Nusselt number obtained from the present study are in good agreement with the previous numerical and experimental results currently available. To show the effects of pipe curvature on the flow and heat transfer, the resistance coefficients and heat transfer coefficients are computed and compared with the results of the previous theoretical and experimental studies. The averaged Nusselt number is correlated with Dean and Prandtl numbers. Furthermore, the critical Reynolds number for transition to turbulent flow is observed to depend upon the curvature ratio.
Transactions of the Korean Society of Mechanical Engineers B
/
v.24
no.8
/
pp.1046-1055
/
2000
The flow and thermal phenomena in flat tubes of radiator are analyzed numerically. To predict the characteristics of heat transfer and pressure drop, the flow analysis program for three-dimensional complex geometry is developed, which adopted an non-staggered grid system and Cartesian velocities as dependent variables of the momentum equations. Using the developed program, the effect of tube specifications on the heat transfer characteristics is investigated for various flat tubes. From this study, the following results are obtained; (1) For the same hydraulic diameter($D_h{\doteq}5.2$mm), the Nusselt numbers of three basic modeis(D, J, and H-model) are 8.71, 8.92, and 10.58, respectively, and the pressure drops of D-, J-, and H-model are predicted as $-3.08{\times}10^{-2}\;Pa,\;-3.12{\times}10^{-2}\;Pa,\;and\; -3.98{\times}10^{-2}$ Pa, (2) In case of the same flat tube specification, the fins must be brazed at upper tube surface because the heat is more vividly transferred. Therefore, it is found that the H- model is the most effective tube as a heat exchanger and these results are used as a fundamental data for the design of tube.
Journal of the Korea Academia-Industrial cooperation Society
/
v.16
no.11
/
pp.7667-7671
/
2015
Recently, Zinc coating is often used with environment friendly features and high performance. Generally The coating temperature is one of main factors for determining coating thickness and coating ability, so the optimal coating temperature is strongly required. In this paper, the thermo-flow simulation considering the air flow inside the coating rooms for analyzing the temperature distributions of Zinc spray coating room was performed. Two spray coating rooms, preheating room and drying room were all modeled by SolidWorks program and the temperature distributions were analyzed by Flow simulation program. The analysis results were verified with the measured data by thermal image camera. The characteristics of temperature distributions of the first spray room and the second spray room were understood and the results showed that the temperatures of two spray coating room were low compared with the target temperature $25^{\circ}C$. To the exclusion of heater addition, the simulation with all the same conditions exclusive the exhaust fan was performed, which showed that the temperatures of the first and the second spray rooms increased by $6.2^{\circ}C$ and $5.8^{\circ}C$. This analysis can be applicable for designing a new spray coating room for improving performance.
Journal of the Korean Society for Aeronautical & Space Sciences
/
v.33
no.8
/
pp.111-121
/
2005
A 100kW class gas turbine combustor was developed and tested for PPU(Primary Power Unit) of ground vehicle. The combustor which employed annular-reverse type and pressure swirl atomizer was designed through 1-D analysis, 3-D thermal flow analysis and combustor performance was experimentally investigated on the combustor test rig. The test result was satisfactory. The developed combustor was also tested for environmental and endurance specification under engine adopted conditions and the application of a state-of-the-art gas turbine combustor to ground vehicle PPU turned out to be successful.
Hwang, Byeong Jo;Kim, Seon Ho;Joo, Won Gu;Cho, Hyung Hee
Journal of the Korean Society of Propulsion Engineers
/
v.21
no.2
/
pp.83-93
/
2017
A numerical analysis is made of the fluid flow and heat transfer characteristics in the corrugated structure that traps the spent air in the corrugations between impinging jets to reduce crossflow effects on downstream jets in the array. All computations are performed by considering three-dimensional, steady state, and incompressible flow by using the ANSYS-CFX 15.0 code. Averaged jet Reynolds number is 10,000. The oblique angles of impingement jets on the spanwise section are $70^{\circ}$, $80^{\circ}$, $90^{\circ}$, and the oblique angles of impingement jets on the streamwise section are $70^{\circ}$, $90^{\circ}$, $110^{\circ}$. The investigation focuses on the oblique angle influence of impinging jet array on the fluid flow and heat transfer characteristics of a corrugated structure.
Proceedings of the Korea Water Resources Association Conference
/
2012.05a
/
pp.205-205
/
2012
국내에서 새로운 댐 저수지 건설을 통한 수자원의 안정적인 확보는 어려운 여건에 있다. 따라서 수자원의 효율적인 확보, 댐 하류하천의 수질 개선, 신규댐 건설 대체 효과를 기대하기 위해 기존 댐 저수지의 연계운영이 중요하게 인식되고 있다. 본 연구에서는 다수의 댐 저수지 수체를 연계하여 모델을 통해 해석하고자 안동-임하호를 연결한 2차원 모델(CE-QUAL-W2)을 구축하고, 2002년과 2006년 수문사상을 재현하였으며, 수리해석을 실시하였다. 안동호의 좌안인 임동면 마리와 임하호의 우안인 망천리를 연결하고, EL. 140 m 위치에 길이 2 km, 직경 5.5 m로 콘크리트 터널을 연결하는 것으로 가정하였다. 관내 바닥 마찰계수와 미소 마찰손실 값은 0.05를 입력하였다. 저수지 실측수위와 모의수위를 시계열로 비교한 결과, 2002년과 2006년 안동호와 임하호에서 여름철 유입량 증가에 따른 수위 상승을 잘 반영하였고, 결정계수값($R^2$)이 모두 0.9953 이상으로 나타나 모델은 두 저수지 물수지 계산에 있어서 높은 신뢰도를 보였다. 2006년을 대상으로 안동호와 임하호의 댐 앞에서 수심별 수온의 실측값과 모의값을 비교한 결과, 안동호는 4월부터 성층이 진행되어 5월에 수온약층이 EL. 130 m에 형성되었다. 7월 홍수가 중층 밀도류를 형성하여 수온 성층구조를 교란하였고, 기존의 수온약층이 EL. 120 m 로 하강하였으며, 표층 EL. 145 m에 새로운 수온약층이 형성되는 2단 성층 구조를 보였다. 여름철 동안 이러한 현상은 지속되었고, 10월부터 대기기온 강하와 함께 수직혼합이 시작되었다. 수온예측 오차는 AME $0.336{\sim}1.806^{\circ}C$, RMSE $0.415{\sim}2.271^{\circ}C$의 범위로 실측값을 잘 반영하는 것으로 나타났다. 임하호도 안동호와 유사한 경향을 보였고, 모델은 두 저수지에서 전 기간에 걸쳐 모두 안정적으로 저수지 수온 성층현상을 모의하였다. 2002년 수문사상에서 안동-임하 연계 운영시 안동호의 평균 수위는 1.38 m 상승하였고, 임하호는 3.75 m 낮아지는 것으로 모의되었다. 수위변동에 따른 유동 유량은 임하호에서 안동호로 3억 6천 4백만 톤, 안동호에서 임하호로 2억 9천 1백만 톤으로 임하호에서 안동호로 유동한 유량이 높게 나타났다. 유역면적에 비해 저수용량이 작은 임하호의 경우 두 저수지간 유량의 이동에 따라서 저수용량의 증가로 인한 홍수 저감 효과가 있을 것으로 판단된다. 반면, 안동-임하 연계 운영시 임하호의 차가운 물이 안동호로 유입되는 경우, 안동호의 수온 성층구조에 영향을 주었다. 안동호의 경우는 단독운영시보다 높은 위치에 수온약층(EL. 140 m)이 형성되었으며, 임하호는 반대로 저수위가 낮아지면서 단독운영시보다 수온약층의 위치가 약간 낮아졌다. 이러한 결과는 두 저수지 연결시 안동호의 탁수와 수질 환경에 변화가 있을 수 있음을 시사한다.
Park Sunghan;Lee Sangyeon;Park Jongkyoo;Kim Wonhoon;Moon Soonil
Journal of the Korean Society of Propulsion Engineers
/
v.9
no.3
/
pp.18-24
/
2005
To evaluate structural safety factor of the jet vane for the thrust deflection system under the dynamic pressure and very high temperature(2700$^{\circ}C$ ) of the combustion gas flow, the high temperature tension tests of refractory metals and 3-D nonlinear numerical simulations are performed. Through the analysis of high temperature structure behavior for jet vane, the structure safety of jet vane is evaluated, and numerical results are compared with static ground tests of jet vanes. It has been found that most of structural and thermal loading is concentrated on the vane shaft which worked as safe under 1400$^{\circ}C$. From the comparison of static ground tests and numerical results, the evaluation criterion using the vane load and shaft displacement is more useful to estimate the structural safety than using the equivalent stress.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.