• Title/Summary/Keyword: 2nd harmonic

Search Result 168, Processing Time 0.025 seconds

A Linearity Improved Power Amplifier using Bandpass Filter Based on Composite Right-/Left-Handed Structure (CRLH 구조의 대역통과여파기를 이용한 전력증폭기의 선형성 개선에 관한 연구)

  • Kim, Hyoung-Jun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, we present a bandpass filter (BPF) based on composite right-/left-handed (CRLH) structure for improving the linearity of the power amplifier. The proposed BPF consist of the inter-digit signal line on the top plane and the complementary split ring resonator (CSRR) on the bottom plane, respectively. The insertion loss is minimized at operation frequency and the 2nd harmonic is suppressed by the bandpass filter using the CRLH structure, respectively. The output power of 33 dBm, the 2nd harmonic of -53.527 dBc, 3rd inter-modulation distortion of -36.16 dBc was obtained at 2.14 GHz, respectively. Compared with the reference power amplifier, the 2nd harmonic of 16 dB and 3rd inter-modulation distortion of 12 dB have been improved at 2.14 GHz, respectively.

Characteristics of a third-harmonic mode-locked Nd:YLF laser (3차 조화 모드록킹 Nd:YLF 레이저의 특성 연구)

  • 성재희;유태준;남창희
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.44-45
    • /
    • 2000
  • GHz 급의 아주 높은 반복율을 가지면서, 피코초 단위의 펄스 열을 발진시키는 레이저를 만들기 위해 능동형 모드록킹 방법을 이용하였다. 이 방법은 공진기안에 광 변조기를 삽입하고, RF 신호를 가하여 시간적으로 공진기내에서의 손실을 변화시키는 방법이다.$^{(1)}$ 공진기 길이를 충분히 길게 하면서도 고 반복율을 가지는 레이저를 만들기 위해 조화 모드록킹 방법을 사용했는데, 이는 레이저 펄스의 반복율을 공진기 길이에 의한 기본 반복율의 정수배가 되도록 하는 방법이다.$^{(2),(3)}$ 3차 조화 모드록킹 방법을 이용한 Nd:YLF 레이저 시스템을 그림 1에서 나타내었다. (중략)

  • PDF

Self-Oscillating, Third-Harmonic Mode-Locked l-GHz Nd:YLF Laser

  • Yu, Tae-Jun;Sung, Jai-Hee;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.3 no.2
    • /
    • pp.51-54
    • /
    • 1999
  • A Nd:YLF laser has been actively mode-locked at the third-order harmonic cavity frequency using a lithium niobate phase modulator. Self-oscillating pulses of 14 ps duration, 1 GHz repetition rate, and 10mV average power at 1053 nm wavelength have been obtained. A 1GHz rf signal to drive a phase modulator was obtained by using 1GHz pulse train without rf synthesizer as a driver of an active mode locker.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

An Experimental Study on the 2nd,3rd Harmonic Characteristic for open-tube-type and close-tube-type Thermoacoustic Refrigerators (밀폐관형과 개방관형 열음향 냉동기의 2차, 3차 하모닉에 관한 특성 연구)

  • 송규조;박종호;고득용;박성제;김효봉;박영선
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.193-196
    • /
    • 2002
  • The thermoacoustic refrigerator has not only considerable possibility but also commercial usability, because it has high reliability, lower vibration, no moving part, and can easily be constructed. In order to determine the optimum resonant tube length and the frequency, the open-tube-type(3$\lambda$/4) and close- tube - type (2$\lambda$/2) thermoacoustic refrigerator were constructed. In third harmonic, the temperature difference of 3$\lambda$/4 refrigerator was $53^{\circ}C$(resonator length :400mm). In second harmonic, the temperature difference of 2$\lambda$/2 refrigerator was $51^{\circ}C$(resonator length :400mm).

  • PDF

The ablation of ITO thin films by KrF Eximer laser and its characteristics (KrF 엑시머 레이저에 의한 ITO 박막의 어블레이션과 표면특성관찰)

  • Lee, Kyoung-Cheol;Lee, Cheon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.511-514
    • /
    • 2000
  • This work aimed to develop ITO (Indium Tin Oxide) thin films ablation with a KrF Eximer laser required for the application in flat panel display, especially patterning into small geometry on a large substrate area. The threshold fluence for ablating ITO on glass substrate is about 0.1 J/cm$^2$. And its value is much smaller than using third harmonic Nd:YAG laser. Through the optical microscope measurement the surface color of the damaged ITO is changed into dark brown and irradiated spot is completely isolated form the undamaged surroundings by laser light. The XPS analysis showed that the relative surface concentration of Sn and In were essentially unchanged (In :Sn=5:1) after irradiating Eximer laser. Using aluminium mask made by second harmonic Nd:YAG laser the ITO patterning is carried out.

  • PDF

Quantitative Evaluation Technique for Healing Fractured Bones Using Ultrasound (초음파를 이용한 골절치유과정의 정량적 평가기법)

  • 최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.3
    • /
    • pp.359-366
    • /
    • 1995
  • The parameter, B/A, quantifies nonlinearity of the pressure-density relationship of propagation medium. This study investigated quantitative evaluation technique for healing fractured bones using this ultrasonic nonlinear parameter, B/A, obtained by the second harmonic amplitude method. A series of fundamental experiments were performed on cylinder phantoms made of aluminium, which demonstrated potential capability of nonlinear parameter B/A in the diagnosis of healing fractured bones using ultrasound.

  • PDF

A study on the Second-Harmonic Generation(SBG) Conversion Characteristics of Nd:YAG Laser adopted Differential Superposition Mesh (중첩회로를 적용한 펄스형 Nd:YAG 레이저의 2차 SHG 변환효율에 관한 특성연구)

  • 김휘영;박두열
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.215-218
    • /
    • 2001
  • A pulsed Nd:YAG laser is used widely for materials processing and medical instrument. It's very important to control the laser energy density in those fields using a pulsed Nd:YAG laser. A pulse repetition rate and a pulse width are regarded as the most dominant factors to control the energy density of laser beam. In this paper, the alternating charge and discharge system was designed to adjust a pulse repetition rate. This system is controlled by microprocessor and allows to frequence an expensive condenser for high frequency to cheap one for low frequency. In addtion, The microcontroller monitors the flow of cooling water, short circuit, and miss firing and so on. We designed Nd:YAG laser firmware with smart microcontroller, and want to explain general matters about the firmware from now.

  • PDF

High-Performance Millimeter Wave Harmonic Output Oscillator using Sub-Harmonic Wave Injection-Synchronization (서브하모닉 주입동기에 의한 밀리미터파 대역 고조파 발진기의 고성능화)

  • Choi, Young-Kyu;Nam, Byeong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.17-24
    • /
    • 2008
  • This paper deals with a millimeter wave source which is utilizing sub-harmonic injection-synchronization technique. A 8.7GHz oscillator with MES-FET is fabricated, and is driven as a harmonic output oscillator at 17.4GHz by means of sub-harmonic injection-synchronization. The oscillator operates as a multiplier as well as oscillator in this system. Adopting this technique, we can obtain a high stable, high frequency millimeter wave source even though self-oscillating frequency of an oscillator is relatively low. In the experiments, the range of injection-synchronization is about 26MHz and is proportional to the input sub-harmonic power. From the spectrum analysis of the 2nd harmonic output. we blow that the phase noise of the harmonic oscillator is remarkably decreased.

Design of Ku-Band Phase Locked Harmonic Oscillator (Ku-Band용 위상 고정 고조파 발진기 설계)

  • Lee Kun-Joon;Kim Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.49-55
    • /
    • 2005
  • In this paper, the phase locked harmonic oscillator(PLHO) using the analog PLL(Phase Locked Loop) is designed and implemented for a wireless LAN system. The harmonic oscillator is consisted of a ring resonator, a varactor diode and a PLL circuit. Because the fundamental fiequency of 8.5 GHz is used as the feedback signal for the PLL and the 2nd harmonic of 17.0 GHz is used as the output, a analog frequency divider for the phase comparison in the PLL system can be omitted. For the simple PLL circuit, the SPD(Sampling Phase Detector) as a phase comparator is used. The output power of the phase locked harmonic oscillator is 2.23 dBm at 17 GHz. The fundamental and 3rd harmonic suppressions are -31.5 dBc and -29.0 dBc, respectively. The measured phase noise characteristics are -87.6 dBc/Hz and -95.4 dBc/Hz at the of offset frequency of 1 kHz and 10 kHz from the carrier, respectively.