• Title/Summary/Keyword: 2D scanner

Search Result 403, Processing Time 0.025 seconds

Measurements of Defects after Machining CFRP Holes Using High Speed Line Scan (고속 라인 스캔 방식을 이용한 CFRP 가공 홀 표면 및 내부 결함 검사)

  • Kim, Teaggyum;Kyung, Daesu;Son, Unchul;Park, Sun-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.6
    • /
    • pp.459-467
    • /
    • 2016
  • Using a line scan camera and a Galvano mirror, we constructed a high-speed line-scanning microscope that can generate 2D images ($8000{\times}8000pixels$) without any moving parts. The line scanner consists of a Galvano mirror and a cylindrical lens, which creates a line focus that sweeps over the sample. The measured resolutions in the x (perpendicular to line focus) and y (parallel to line focus) directions are both $2{\mu}m$, with a 2X scan lens and a 3X relay lens. This optical system is useful for measuring defects, such as spalling, chipping, delamination, etc., on the surface of carbon fiber reinforced plastic (CFRP) holes after machining in conjunction with adjustments in the angle of LED lighting. Defects on the inner wall of holes are measured by line confocal laser scanning. This confocal method will be useful for analyzing defects after CFRP machining and for fast 3D image reconstruction.

A Study on the Digital Map Production and Water Supply management in GIS (GIS에 의한 수치지도 제작과 상수도 관리에 관한 연구)

  • 강준묵;윤희천;한승희
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.11 no.2
    • /
    • pp.59-67
    • /
    • 1993
  • Since society rapidly change, we need accurate and rapid information. Due to complication and rapid change of national infrastructure system, we meet a limitation of 2-D information management. Currently most digital cartographic data is acquired by manual digitizing with a tablet. Recently high cost scanner is widely used and preprocessing and postprocessing software of scanning are developed, so we expect its availability. In this study, we know that scanning is more convenient than digitizing with a tablet for digital mapping, also, possibility of 3-D modeling of vectorized document is suggested. Because information rapidly provided in the planning and implementation, operation efficiency and advance are archived in water supply project. Improvement of service for need of citizen and possibility combined information system connected with other system is presented.

  • PDF

Investigations into the Influencing Fabric Properties Factors of the 3D Shape Evaluation of Korean Hanbok Chima

  • Park, Soon-Jee
    • International Journal of Human Ecology
    • /
    • v.7 no.1
    • /
    • pp.37-52
    • /
    • 2006
  • This study was designed to analyze the three-dimensional shapes of Hanbok Chima made with various fabrics and to clarify the relationship between fabric properties as well as the objective and subjective evaluations of the 3D shape. For 3D shape data, a dress form (9A2 (N; nude)) was scanned with eight Chima garments made with the same number of fabrics. The scanner used was a non-contact three-dimensional human body measuring system belonging to Bunka Women's University in Japan. Data concerning the objective evaluation of the 3D shape was obtained from the measurements of the vertical and horizontal sections: those for subjective evaluation were through the sensory test after exposure to photographs from a front and side view. Four fabric factors were extracted from fabric physical properties: softness, extension, thickness of threads, and weight of fabric. Such factors as expansion (volume), sag of rear train, shape of nodes were influential in explaining the 3D shape of Hanbok Chima. From the analysis of the 3D shape, it can be deduced that with the constituent fabric stiffer, lighter, and less stretchable, the more expanded the 3D shape appeared to be. Multiple regression results showed that vertical shape factors have a greater effect on the evaluation of the 3D shape. It also implies that dependent variables of this study such as the subjective evaluation and 3D shape can be derived from regression equations on independent variables as fabric property factors or 3D shape factors. These results can enable the manufacturers to predict the 3D shape of the garment as well as the human subjective assessment to improve the efficacy of production. The investigation method proposed in this study can also be applicable to other garment items.

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • v.47 no.2
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

Analysis of deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a DLP printer (DLP 프린터로 출력한 임시의치용 전악 인공치아의 후경화에 따른 변형 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.48-55
    • /
    • 2021
  • Purpose: This study aimed to analyze deformation according to post-curing of complete arch artificial teeth for temporary dentures printed with a digital light processing (DLP) printer. Methods: An edentulous model was prepared and an occlusal rim was produced. The edentulous model and occlusal rim were scanned using a model scanner. A complete denture was designed using a dental computer-aided design, and the denture base and artificial tooth were separated. Ten complete arch artificial teeth were printed using a 3D printer (DLP). Complete arch artificial teeth was classified into the following three groups: a group no post-curing (NC), a group with 10 minutes post-curing (10M), and a group with 20 minutes post-curing (20M). Specimens were scanned using a model scanner. The scanned data were overlapped with the reference data. Statistical analysis was performed using one-way ANOVA analysis of variance, Kruskal-Wallis test, and Mann-Whitney U test (α=0.05). Results: Regarding the overall deviation of complete arch artificial teeth, the NC group showed the lowest mean deviation of 111.13 ㎛ and the 20M group showed the highest mean deviation of 131.03 ㎛. There were statistically significant differences among the three groups (p<0.05). Conclusion: The complete arch artificial tooth showed deformation due to post-curing. In addition, the largest shrinkage deformation was observed at 10 minutes of post-curing, whereas the least deformation was observed at 20 minutes.

Evaluation of Articular Cartilage using 3D FFE-PROSET Technique in 3.0 T Knee MR Imaging : Comparison with 2D TSE - SPIR Technique (3.0T 무릎자기공명영상에서 3차원 FFE-PROSET 기법을 이용한 관절연골평가 : 2차원 TSE-SPIR 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.599-606
    • /
    • 2013
  • The purpose of this study is to know a clinical usefulness for delineation of articular cartilage compared with 2D TSE-SPIR and 3D FFE-PROSET technique. From January 2013 to september 2013, a total of 30 normal volunteers(12 men and 18 women aged between 35 and 55 years; mean 49.48 years) were studied on a philips 3.0T MRI scanner. As a quantitative analysis, SNRs and CNRs were evaluated by using two methods for delineation of articular cartilage. As a qualitative analysis, image quality was evaluated by special radiological technologist of MRI for image delineation on a three grade. As a results, SNRs and CNRs for articular cartilage were significantly greater for the 3D FFE-PROSET(SNRs: 8.40, 114.02, 9.53, CNRs: 104.49, 139.49) technique compared to 2D TSE-SPIR(SNRs: 4.41, 71.63, 7.34, CNRs: 64.30, 58.41) technique, image quality also was higher for evaluation of 3D FFE-PROSET(2.40) technique(p=0.0021). In conclusion, this study showed that a 3D FFE-PROSET MRI has improved SNRs and CNRs for evaluating of the articular cartilage, these conclusions in the future will be provided useful information in diagnosis of articular cartilage.

Fast Local Indoor Map Building Using a 2D Laser Range Finder (2차원 레이저 레이진 파이더를 이용한 빠른 로컬 실내 지도 제작)

  • Choi, Ung;Koh, Nak-Yong;Choi, Jeong-Sang
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.99-104
    • /
    • 1999
  • This paper proposes an efficient method constructing a local map using the data of a scanning laser range finder. A laser range finder yields distance data of polar form, that is, distance data corresponding to every scanning directions. So, the data consists of directional angle and distance. We propose a new method to find a line fitting with a set of such data. The method uses Log-Hough Transformation. Usually, map building from these data requires some transformations between different coordinate systems. The new method alleviates such complication. Also, the method simplifies computation for line recognition and eliminates the slope quantization problems inherent in the classical Cartesian Hough transform method. To show the efficiency of the proposed method, it is applied to find a local map using the data from a laser range finder PLS(Proximity Laser Scanner, made by SICK).

  • PDF

A Study on Airborne LiDAR Calibration and Operation Techniques for Bathymetric Survey

  • Shin, Moon Seung;Yang, In Tae;Lee, Dong Ha
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2016
  • The necessity of maritime sector for continuous management, accurate and update location information such as seabed shape and location, research on airborne LiDAR bathymetry surveying techniques are accelerating. Airborne LiDAR systems consist of a scanner and GPS/INS. The location accuracy of 3D point data obtained by a LiDAR system is determined by external orientation parameters. However, there are problems in the synchronization between sensors should be performed due to a variety of sensor combinations and arrangement. To solve this issue, system calibration should be conducted. Therefore, this study evaluates the system verification methods, processes, and operation techniques.

Modified S-N Curve Method to Estimate Fatigue life of Welded Joints (수정 S-N곡선법을 이용한 용접연결부의 피로수명 추정)

  • Yang, Park-Dal-Chi;Kim, Mi-Kyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.26-32
    • /
    • 2012
  • In this paper, the effects of irregular bead shapes on fatigue life were investigated. A modified S-N curve method was used to estimate the fatigue life, which considered the inherent multiaxiality caused by the geometrical feature produced by the welding process. The point method of the critical distance method was used to determine the fatigue effective stress. Three types of fillet joint models were tested in the fatigue experiments. For each model, real bead shapes were collected using a 3D laser scanner, and finite element analyses were performed. The results of the analyses with actual bead shapes were compared with those using an idealized bead shape model. The results of the present analytical methods showed good agreement with the experimental results.

Prototype Torso Pattern for Circular Knit using Virtual Garment Software (가상착의에 의한 환편물 상의의 패턴 설계 방법 연구)

  • Kim, Hyeong Jin;Kim,, Yeo-Sook
    • The Korean Journal of Community Living Science
    • /
    • v.22 no.1
    • /
    • pp.53-61
    • /
    • 2011
  • We have made knitwear in a different way from the typical woven pattern; it does not have the dart, even for women's tops. The purpose of this research was to compare the fit and appearance of the torso pattern for circular knitted fabric between virtual try-on garments and real garments. First, a woman in her 20's was scanned by a 3D body scanner, and thus producing a virtual avatar. I prepared knit patterns and created a torso pattern appropriate for circular knitted fabric. Next, I measured the body size of the avatar. The 2D patterns for the torso and sleeves were developed using the Yuka Super ALPHA : Plus. The 3D virtual garments were made from the imported 2D patterns and were then tried on the 3D virtual avatars. Finally, the fit of the real garments and the virtual garments was compared. While the shape of the virtual try-on garments were similar to the real garments, the folding and sagging were different. This study found the length was the same as woven wear. However the actual bust size and the clothing size were the same which is not a typical characteristic of woven wear. In the case of hem measurement, more space was needed than actual body size but less space was needed than in woven patterns.