• Title/Summary/Keyword: 2D measurement data

Search Result 810, Processing Time 0.035 seconds

Development of a 3-D Position Measurement Algorithm using 2-D Image Information (2차원 영상 정보를 이용한 3차원 위치 측정 알고리즘 개발)

  • Lee, J.H.;Jung, S.H.;Kim, D.H.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.5
    • /
    • pp.141-148
    • /
    • 2013
  • There are several problems in the conventional 2-D image processing and 3-D measurement systems. In the case of the 2-D image processing system, it is not possible to detect elevation data. In a 3-D measurement system, it requires a skillful operator and a lot of time for measuring data. Also, there exist data errors depending on operators. The limitation of detecting elevation data in the 2-D image processing system can be solved by laser diodes. In this study an algorithm that measures the accurate data in a subject face to be detected by combining laser diodes and a commercial CCD camera is developed. In the development process, a planar equation is developed using laser diodes and the equation is used to obtain a normal vector. Based on the results, an algorithm that transforms commercial CCD camera coordinates to 3-D coordinates is proposed. The completed measurement method will be applied to replace a manual measurement system for vehicle bodies and parts by an automated system.

A Software Error Examination of 3D Automatic Face Recognition Apparatus(3D-AFRA) : Measurement of Facial Figure Data (3차원 안면자동인식기(3D-AFRA)의 Software 정밀도 검사 : 형상측정프로그램 오차분석)

  • Seok, Jae-Hwa;Song, Jung-Hoon;Kim, Hyun-Jin;Yoo, Jung-Hee;Kwak, Chang-Kyu;Lee, Jun-Hee;Kho, Byung-Hee;Kim, Jong-Won;Lee, Eui-Ju
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.3
    • /
    • pp.51-61
    • /
    • 2007
  • 1. Objectives The Face is an important standard for the classification of Sasang Constitutions. We are developing 3D Automatic Face Recognition Apparatus(3D-AFRA) to analyse the facial characteristics. This apparatus show us 3D image and data of man's face and measure facial figure data. So We should examine the Measurement of Facial Figure data error of 3D Automatic Face Recognition Apparatus(3D-AFRA) in Software Error Analysis. 2. Methods We scanned face status by using 3D Automatic Face Recognition Apparatus(3D-AFRA). And we measured lengths Between Facial Definition Parameters of facial figure data by Facial Measurement program. 2.1 Repeatability test We measured lengths Between Facial Definition Parameters of facial figure data restored by 3D-AFRA by Facial Measurement program 10 times. Then we compared 10 results each other for repeatability test. 2.2 Measurement error test We measured lengths Between Facial Definition Parameters of facial figure data by two different measurement program that are Facial Measurement program and Rapidform2006. At measuring lengths Between Facial Definition Parameters, we uses two measurement way. The one is straight line measurement, the other is curved line measurement. Then we compared results measured by Facial Measurement program with results measured by Rapidform2006. 3. Results and Conclusions In repeatability test, standard deviation of results is 0.084-0.450mm. And in straight line measurement error test, the average error 0.0582mm, and the maximum error was 0.28mm. In curved line measurement error test, the average error 0.413mm, and the maximum error was 1.53mm. In conclusion, we assessed that the accuracy and repeatability of Facial Measurement program is considerably good. From now on we complement accuracy of 3D-AFRA in Hardware and Software.

  • PDF

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Performance Test of 2-Dimensional PIV and 3-Dimensional PIV using Standard Images (표준화상을 이용한 2차원 PIV와 3차원 PIV계측 및 성능비교검정)

  • Doh, D.H.;Hwang, T.G.;Song, J.S.;Baek, T.S.;Pyun, Y.B.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.646-651
    • /
    • 2003
  • Quantitative performance test on the conventional 2D-PIV and the hybrid angular 3D-PIV (Stereoscopic PIV) was carried out. LES Data sets on an impinging jet which are provided on the webpage(http://www.vsj.or.jp/piv) for the PIV Standard Project were used for the generation of virtual images. The generated virtual images were used for the 2D-PIV and 3D-PIV measurements. The measurement results showed that the results obtained by 2D-PIV on average values are closer to the LES data than those obtained by 3D-PIV, but the turbulent properties obtained by 2D-PIV are largely underestimated than those obtained by 3D-PIV.

  • PDF

Studies on Representative Body Sizes and 3D Body Scan Data of Korean Adolescents (한국 청소년의 대표 인체치수 및 3D 인체형상자료에 관한 연구)

  • Choi, Seung-il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • 3D body scan data are used widely in various fields to make products and living spaces for superior human body fitness. Based on the 3D measurements of human bodies for teens in Size Korea 2013, this research provides a way of finding the representative body sizes and 3D body scan data. First, a multi-dimensional vector space consisting of many measurement items was projected onto a 2D vector space with circumference and length components via factor analysis. The representative body sizes and 3D scan data close to these values were obtained via the Mahalanobis distance in 2D space. Considering the adolescent growth pattern shown on this 2D space, males were divided into 4 age groups and females were divided into 3 age groups. Using the eigenbodies corresponding to the column vectors of the component score coefficient matrix, the representative body sizes of 13 measurement items (male) and 14 measurement items (female) for each age group were calculated. The representative body sizes and 3D scan data are very useful for modeling representative 3D human figures.

High precision 3-dimensional object measurement using slit type of laser projector (슬리트형 레이저 투광기를 이용한 고정밀 3차원 물체계측)

  • Kim, Tae-Hyo;Park, Young-Seok;Lee, Chuy-Joong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.613-618
    • /
    • 1997
  • In this paper, we designed a line CCD camera for a flying image, which is composed of a line CCD sensor(2048 cells) and a rotating mirror, and investigated its optical properties. We also made the 3-D image from the flying image which is made of 2-D image being juxtaposed to 1-D images obtained by the camera, and performed the calibration to acquire high precision 3-D data. As a result, we obtained the 3-D measurement system using the slit type of laser projector is available to measure the high precision shape of objects.

  • PDF

Study about the Applicable Plan of GIS on Range of Magnetic Field Emitted from 60 Hz Powerline (60Hz 고압 송전선로의 자기장 발생범위에 대한 GIS 적용 방안에 대한 연구)

  • Hong, Seung Cheol;Choi, Seong Ho;Kim, Yoon Shin;Park, Jae Young
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.4
    • /
    • pp.271-277
    • /
    • 2006
  • In this study, we investigated the applicable plan of GIS on the environmental impact assessment of 60 Hz Powerline. So we assessed distance data based on calculations by use of 2D and 3D Geographical information systems(GIS) and distance data based on measurements on 1: 5000 maps accord with on site distance measurements to use input data for calculating magnetic field. One hundred eight of the on site measured addresses were selected from residences. The data were achieved by measuring the distance between residence and power line on maps with scales of 1: 5000. The digital map was obtained from National Geographic Information Institute with scales of 1: 5000, and we made 2D and 3D map. Correlation analyses were performed for statistical analyses. For the 3D GIS versus on site comparison of different exposure categories, 70 of 108 measurements were assigned to the correct category. Similarly for 2D GIS versus on site comparison, 71 of 108 were correctly categorized. When comparing map measurement with on site measurement, 62 of 108 were correctly categorized. When the correlation analysis was performed, best correlation was found between 3D GIS and on site measurements with r = 0.84947 (p<0.0001). The correlation between map and on site measurement yielded an r of 0.76517 (p<0.0001). Since the GIS measurements and map measurement were made from the center point in the building and the on site measurements had to be made from the closest wall on the building, this might introduce and additional error in urban areas. The difference between 2D and 3D calculations were resulted from the height of buildings.

Comparative study of glenoid version and inclination using two-dimensional images from computed tomography and three-dimensional reconstructed bone models

  • Choi, Chang-Hyuk;Kim, Hee-Chan;Kang, Daewon;Kim, Jun-Young
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.119-124
    • /
    • 2020
  • Background: This study was performed to compare glenoid version and inclination measured using two-dimensional (2D) images from computed tomography (CT) scans or three-dimensional (3D) reconstructed bone models. Methods: Thirty patients who had undergone conventional CT scans were included. Two orthopedic surgeons measured glenoid version and inclination three times on 2D images from CT scans (2D measurement), and two other orthopedic surgeons performed the same measurements using 3D reconstructed bone models (3D measurement). The 3D-reconstructed bone models were acquired and measured with Mimics and 3-Matics (Materialise). Results: Mean glenoid version and inclination in 2D measurements were -1.705° and 9.08°, respectively, while those in 3D measurements were 2.635° and 7.23°. The intra-observer reliability in 2D measurements was 0.605 and 0.698, respectively, while that in 3D measurements was 0.883 and 0.892. The inter-observer reliability in 2D measurements was 0.456 and 0.374, respectively, while that in 3D measurements was 0.853 and 0.845. Conclusions: The difference between 2D and 3D measurements is not due to differences in image data but to the use of different tools. However, more consistent results were obtained in 3D measurement. Therefore, 3D measurement can be a good alternative for measuring glenoid version and inclination.

Three-dimensional Crush Measurement Methodologies Using Two-dimensional Data (2차원 데이터를 활용한 3차원 충돌 변형 측정 방법)

  • Han, Inhwan;Kang, Heejin;Park, Jong-Chan;Ha, Yongmin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.254-262
    • /
    • 2015
  • This paper presents 3D collision deformation modelling methodologies using photogrammetry for reconstruction of vehicle accidents. A vehicle's deformation shape in collision provides important information on how the vehicle collided. So effective measurement(scanning) and construction of a corresponding appropriate model are essential in the analysis of collision deformation shape for obtaining much information related to collision accident. Two measurement methods were used in this study: Indirect-photogrammetry which requires relatively small amount of photos or videos, and direct-photogrammetry which requires large amount of photos directly taken for the purpose of 3D modelling. When the indirect-photogrammetry method, which was mainly used in this study, lacked enough photographic information, already secured 2D numerical deformation data was used as a compensation. This made 3D collision deformation modelling for accident reconstruction analysis possible.

The Use of Advanced Optical Measurement Methods for the Mechanical Analysis of Shear Deficient Prestressed Concrete Members

  • Wilder, K. De;Roeck, G. De;Vandewalle, L.
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.189-203
    • /
    • 2016
  • This paper investigates on the use of advanced optical measurement methods, i.e. 3D coordinate measurement machines (3D CMM) and stereo-vision digital image correlation (3D DIC), for the mechanical analysis of shear deficient prestressed concrete members. Firstly, the experimental program is elaborated. Secondly, the working principle, experimental setup and corresponding accuracy and precision of the considered optical measurement techniques are reported. A novel way to apply synthesised strain sensor patterns for DIC is introduced. Thirdly, the experimental results are reported and an analysis is made of the structural behaviour based on the gathered experimental data. Both techniques yielded useful and complete data in comparison to traditional mechanical measurement techniques and allowed for the assessment of the mechanical behaviour of the reported test specimens. The identified structural behaviour presented in this paper can be used to optimize design procedure for shear-critical structural concrete members.