• Title/Summary/Keyword: 2D direct body measurement

Search Result 17, Processing Time 0.024 seconds

Development of Male Fitted Torso Type Basic Patterns According to the Body Surface Segment Method (체표면분할법에 의한 성인 남성용 피티드 토르소형 원형 설계)

  • Suh, Chu-Yeon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.7
    • /
    • pp.1109-1120
    • /
    • 2009
  • This study develops a fitted torso type basic pattern for men by utilizing 3D body scan data. Recent fashion trends are reflected in the development of the pattern. The subjects were 15 men in their 20's, who wear size 95 (M size). Body scan data was obtained through a 3D whole body scanner (WB4, Cyberware, USA), and a body surface development figure for developing male fitted torso type basic pattern was attained through the use of Rapid Form 2006 as well as Auto CAD 2006 programs. The results are as follows: A body surface development figure through body surface segment method showed high exactitude in an error range of 100$\pm$1%. In addition, it occurred in an error range of 100:1:3% because of the hard scanning conditions in the incline of the shoulder and armpit areas. However, the body surface development figure as well as the direct measurement results can be used as basic data for the given patternmaking since the error range falls into 100$\pm$3%. Dart amounts obtained from the average cross section were center back 2.2cm (24.3%), back armpit point 3.8cm (41.8%), front armpit point 3.0cm (33.9%). As shown the jacket pattern, the biggest dart amount was portioned out at the back armpit point. The drafting equations for the development pattern acquired are as follows; Full width=C/2+5cm, back length=height/4-1cm, armhole depth=(C/10+12cm)+3cm, back width=2C/10+2cm, front width=2C/10. The development pattern was a fitted torso basic pattern that was composed of 3 pieces, so it would be very useful in developing shirt or jacket patterns. According to the results of the evaluation of the developed pattern appearance, it obtained higher scores of over 3.5 points in almost items, meaning that the developed pattern is appropriate for a male fitted torso type basic pattern. It suggests a possibility of patternmaking from a body surface development figure in 2-D to prototype.

Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

  • Ha, Jin-Suk;Jung, Jae Hong;Kim, Min-Joo;Jeon, Mi Jin;Jang, Won Suk;Cho, Yoon Jin;Lee, Ik Jae;Kim, Jun Won;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.196-202
    • /
    • 2016
  • We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer. The bolus-shaped region of interests (ROIs) were contoured at the surface of the intensity-modulated radiation therapy (IMRT) thorax phantom with 5 mm thickness, after which the digital imaging and communications in mdicine (DICOM)-RT structure file was acquired. The intensity-modulated radiation therapy (Tomo-IMRT) and direct mode (Tomo-Direct) using the Tomotherapy were established. The 13 point doses were measured by optically stimulated luminescence (OSLD) dosimetry. The measurement data was analyzed to quantitatively evaluate the applicability of 3D bolus. The percentage change of mean measured dose between the commercial bolus and 3D-bolus was 2.3% and 0.7% for the Tomo-direct and Tomo-IMRT, respectively. For air-gap, range of the commercial bolus was from 0.8 cm to 1.5 cm at the periphery of the right breast. In contrast, the 3D-bolus have occurred the air-gap (i.e., 0 cm). The 3D-bolus for radiation therapy reduces the air-gap on irregular body surface that believed to help in accurate and precise radiation therapy due to better property of adhesion.

Evaluations and Comparisons of Body Surface Doses during Breast Cancer Treatment by Tomotherapy and LINAC Radiotherapy Devices

  • Lee, Hyun-Jik;Bae, Sun-Hyun;Cho, Kwang Hwan;Jeong, Jae-Hong;Kwon, Su-Il;Lee, Kil-Dong
    • Progress in Medical Physics
    • /
    • v.28 no.4
    • /
    • pp.218-225
    • /
    • 2017
  • Effects on skin caused by the dose from linear accelerator (LINAC) opposing portal irradiation and TomoDirect 3-D modeling treatment according to the radiation devices and treatment methods were measured, and a comparative analysis was performed. Two groups of 10 patients each were created and measurements were carried out using an optically stimulated luminescence dosimeter. These patients were already receiving radiation treatment in the hospital. Using the SPSS statistical program, the minimum and maximum average standard deviations of the measured skin dose data were obtained. Two types of treatment method were selected as independent variables; the measured points and total average were the dependent variables. An independent sample T-test was used, and it was checked whether there was a significance probability between the two groups. The average of the measured results for the LINAC opposing portal radiation was 117.7 cGy and PDD 65.39% for the inner breast, 144.7 cGy and PDD 80.39% for the outer breast, 143.2 cGy and PDD 79.56% for the upper breast, 151.4 cGy and PDD 84.11% for the lower breast, 149.6 cGy and PDD 83.11% for the axilla, and 141.32 cGy and PDD 78.51% for the total average. In contrast, for TomoDirect 3-D conformal radiotherapy, the corresponding measurement values were 137.6 cGy and PDD 76.44%, 152.3 cGy and PDD 84.61%, 148.6 cGy and PDD 82.56%, 159.7 cGy and PDD 88.72%, and 148.6 cGy PDD 82.56%, respectively, and the total average was 149.36 cGy and PDD 82.98%. To determine if the difference between the total averages was statistically significant, the independent sample T-test of the SPSS statistical program was used, which indicated that the P-value was P=0.024, which was 0.05 lower than the significance level. Thus, it can be understood that the null hypothesis can be dismissed, and that there was a difference in the averages. In conclusion, even though the treatment dose was similar, there could be a difference in the dose entering the body surface from the radiation treatment plan; however, depending on the properties of the treatment devices, there is a difference in the dose affecting the body surface. Thus, the absorbed dose entering the body surface can be high. During breast cancer radiotherapy, radiation dermatitis occurs in almost all patients. Most patients have a difficult time while undergoing treatment, and therefore, when choosing a radiotherapy treatment method, minimizing radiation dermatitis is an important consideration.

Measurement of Age-Related Changes in Bone Matrix Using 2H2O Labeling

  • Lee, Jeong-Ae;Kim, Yoo-Kyeong
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.40-45
    • /
    • 2005
  • Age-related changes in bone metabolism are well established by biochemical markers of bone matrix in serum and urine, but analysis of the residual bone matrix, which is still turning over, has not been investigated. In the present study, we measured in vivo rates of bone protein synthesis using a precursor-product method based on the exchange of ²H from ²H₂O into amino acids. Four percent ²H₂O was administered to mice in drinking water after intraperitonial (i.p) bolus injection of 99.9% ²H₂O. Mice were divided into the two groups: growing young mice were administered 4% ²H₂O for 12 weeks after an i.p bolus injection at 5 week of age, whereas weight stable adult mice started drinking 4% ²H₂O 8 weeks later than the growing group and continued 4% ²H₂O drinking for 8 weeks. Mass isotopomer abundance in alanine from bone protein was analyzed by gas chromatography/mass spectrometry. Body ²H₂O enrichments were in the range of 1.88-2.41% over the labeling period. The fractional synthesis rates (ks) of bone protein were 2.000±0.071%/d for growing mice and 0.243±0.014%/d for adult mice. These results demonstrate that the bone protein synthesis rate decreases with age and present direct evidence of age-related changes in bone protein synthesis.

Measurement and FEM Analysis of Elastic Deformation According to the Forging Stages in Cold Forging Die (냉간단조용 금형의 변형모드에 따른 탄성변형량의 측정 및 유한요소 해석)

  • 이대근;이영선;이정환
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.112-116
    • /
    • 2002
  • In cold forging, the elastic behavior of the die has a direct influence on the accuracy of the forging part. And the die dimension is continuously changed during the loading, unloading, and ejecting stage. In this paper, we evaluated the elastic deflections of cold forging die during loading, unloading, and ejecting stage. Uni-axial strain gauges are used to measure elastic strain of die during each forging stage. Strain gauges are attached on the surface of die. A commercial F.E.M code, DEFORM-2D$\^$TM/ is used to predict elastic strain of die. Two method of F.E.M. analysis are used to compare with measured and calculated elastic strain. One is to regard the die as rigid body over forging cycle. And then, the die sass is analyzed by loading the die with pressure from the forging part. The other is to regard the die as elastic body from forging cycle. The elastic strain of die is calculated and the die is elastically deformed at each strop. The calculated results under the elastic die assumption are well agreed with experimental data using strain gauges.

  • PDF

An Explanatory Model of Dyspnea in Patients with Chronic Lung Disease (만성폐질환 환자의 호흡곤란 설명모형)

  • Bang, So-Youn
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.1
    • /
    • pp.45-54
    • /
    • 2010
  • Purpose: The purpose of this study was to develop and test an explanatory model of dyspnea in patients with chronic lung disease (CLD). Methods: Participants were 181 patients with CLD, recruited from the outpatient pulmonary clinic of one university hospital in Korea. Data were collected using questionnaires, as well as measurement of 6-minute walking distance (6MWD), oxygen saturation ($SpO_2$), FEV1% predicted, and Body Mass Index (BMI). Results: The results indicated a good fit between the proposed dyspnea model and the collected data [$x^2$=91.27, p= .13, $x^2$/d.f.=1.17, Normal Fit Index= .934]. Oxygenation ($SpO_2$, = -.530), self-efficacy (= -.429), anxiety (= .253), depression (= .224), exercise endurance (6MWD, = -.211), and pulmonary function (FEV1% predicted, = -.178) had a direct effect on dyspnea (all p< .05) and these variables explained 74% of variance in dyspnea. BMI, smoking history, and social support had an indirect effect on dyspnea. Conclusion: The findings of this study suggest that comprehensive nursing interventions should focus on recovery of respiratory health and improvement of emotions, exercise ability, and nutritional status. From this perspective, pulmonary rehabilitation would be an effective strategy for managing dyspnea in patients with CLD.

A Case Study on the Application of Vibration Level Units in the Construction Phase (시공단계의 진동레벨 단위적용에 관한 사례 연구)

  • Choi, Hyung-Bin;Kim, Dong-Yeon
    • Explosives and Blasting
    • /
    • v.30 no.2
    • /
    • pp.86-97
    • /
    • 2012
  • Ground vibration induced by a bench blasting in the construction site should cause the damage to the structure and indirect damage to a human body, and the vibration level is most practical descriptor for regulating the damage to human body and peak particle velocity is the descriptor for direct damage assesment of the structure. Meantime, the vibration level has not been considered for the blasting design but this study is the case that apply not only peak particle velocity but also vibration level on the blasting design. Also, we strongly believe that this study will be helpful for the management in the blasting site which some civil appeal is concerned. Total 232 measurements of both ppv and vibration level was used to estimate the scale distance. When the regulating threshold was ppv 0.3 cm/s and vibration level 75 decibel, the charge per delay to be estimated with vibration level could be recommended by 1.2~1.4 times than it of ppv. So, it is proven that considering vibration level on the blasting design is reasonable for not only prevention of the civil appeals but also effective blasting. Again, the blasting design which follows the law, "Noise and Vibration Control Act" can actually serve good condition to carry much more economical and effective blasting. The instruments used for this study are the SV-1 model, as first instrument in korea which can measure vibration velocity and vibration level at the same time.