• Title/Summary/Keyword: 2D Imaging

Search Result 1,174, Processing Time 0.031 seconds

Study on the Performance of Infrared Thermal Imaging Light Source for Detection of Impact Defects in CFRP Composite Sandwich Panels

  • Park, Hee-Sang;Choi, Man-Yong;Kwon, Koo-Ahn;Park, Jeong-Hak;Choi, Won-Jae;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.2
    • /
    • pp.91-98
    • /
    • 2017
  • Recently, composite materials have been mainly used in the main wings, ailerons, and fuselages of aircraft and rotor blades of helicopters. Composite materials used in rapid moving structures are subject to impact by hail, lightning, and bird strike. Such an impact can destroy fiber tissues in the composite materials as well as deform the composite materials, resulting in various problems such as weakened rigidity of the composite structure and penetration of water into tiny cracks. In this study, experiments were conducted using a 2 kW halogen lamp which is most frequently used as a light source, a 2 kW near-infrared lamp, which is used for heating to a high temperature, and a 6 kW xenon flash lamp which emits a large amount of energy for a moment. CFRP composite sandwich panels using Nomex honeycomb core were used as the specimens. Experiments were carried out under impact damages of 1, 4 and 8 J. It was found that the detection of defects was fast when the xenon flash lamp was used. The detection of damaged regions was excellent when the halogen lamp was used. Furthermore, the near-infrared lamp is an effective technology for showing the surface of a test object.

Comparison between GOx/Kerosene and GN2O/Ethanol Reactive Spray in a Subscale Liquid Rocket Engine (축소형 액체로켓엔진에서 기체산소/케로신 및 기체아산화질소/에탄올 연소 분무의 비교)

  • Choi, Songyi;Shin, Bongchul;Lee, Keonwoong;Kim, Dohun;Koo, Jaye;Park, Dong-Kun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.4
    • /
    • pp.61-68
    • /
    • 2015
  • Reactive sprays of two propellant combinations(GOx/kerosene and $GN_2O$/ethanol) were observed and compared with each other as a basic research of visualizing supercritical combustion. A shadowgraph imaging method was used to visualize the reactive sprays, and shadowgraph images were converted to density gradient magnitude images to analyse the structure of reactive sprays. The gas-liquid interface of GOx/kerosene spray showed rougher boundary and steeper density gradient near the injector face than the $N_2O$/ethanol at similar combustion chamber pressure. Spray core length was calculated from averaged density gradient magnitude images and it was revealed that spray core length of GOx/kerosene was shorter than that of $GN_2O$/ethanol, although momentum flux ratio of GOx/kerosene propellant combination was lower.

Lack of Association between CYP1A1 M2 and M4 Polymorphisms and Breast Carcinoma in Jordanian Women: a Case-Control Study

  • Amrani, Iman;Bulatova, Nailya;Awidi, Abdalla;Yousef, Al-Motassem;Melhem, Jamal Masad;Al-Masri, Mahmoud;Tahoun, Laila Abu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.387-393
    • /
    • 2016
  • Background: CYP1A1 is a candidate gene for low-penetrance breast cancer susceptibility, as it plays an important role in the metabolism of carcinogens and estrogens. Purpose: The objective of this study was to assess the association between M2 (A2455G, Ile462Val) and M4 (C2453A, Thr461Asn) polymorphisms in CYP1A1 and breast cancer risk among Jordanian women and in subgroups stratified by menopausal status and smoking history. Materials and Methods: Blood samples were collected from 112 breast cancer female patients and 115 age-matched controls who underwent breast cancer screening with imaging and showed negative results (BI-RADS I or BI-RADS II). Genotyping was performed using the PCR-RFLP technique. Results: No statistically significant overall association was found between breast cancer risk and CYP1A1 M2 genotypes (p= 0.55; OR = 0.77; 95% CI= 0.32 - 1.83) nor with the M4 polymorphism (p= 0.95; OR= 0.95; 95% CI= 0.51 - 1.88). Analysis of subgroups defined by menopausal status or smoking history also revealed no association with these polymorphisms. Furthermore, the four identified haplotypes (AC; AA; GC and GA) were equally distributed among cases and controls, and haplotype analysis showed a strong linkage disequilibrium of both studied loci in either cases or controls (D'=1). Conclusions: Based on the study results, CYP1A1 M2 and M4 polymorphisms do not seem to play a major role in breast cancer risk among Jordanian females.

The role of surgical clips in the evaluation of interfractional uncertainty for treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy

  • Bae, Jin Suk;Kim, Dong Hyun;Kim, Won Taek;Kim, Yong Ho;Park, Dahl;Ki, Yong Kan
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To evaluate the utility of implanted surgical clips for detecting interfractional errors in the treatment of hepatobiliary and pancreatic cancer with postoperative radiotherapy (PORT). Methods and Materials: Twenty patients had been treated with PORT for locally advanced hepatobiliary or pancreatic cancer, from November 2014 to April 2016. Patients underwent computed tomography simulation and were treated in expiratory breathing phase. During treatment, orthogonal kilovoltage (kV) imaging was taken twice a week, and isocenter shifts were made to match bony anatomy. The difference in position of clips between kV images and digitally reconstructed radiographs was determined. Clips were consist of 3 proximal clips (clip_p, ${\leq}2cm$) and 3 distal clips (clip_d, >2 cm), which were classified according to distance from treatment center. The interfractional displacements of clips were measured in the superior-inferior (SI), anterior-posterior (AP), and right-left (RL) directions. Results: The translocation of clip was well correlated with diaphragm movement in 90.4% (190/210) of all images. The clip position errors greater than 5 mm were observed in 26.0% in SI, 1.8% in AP, and 5.4% in RL directions, respectively. Moreover, the clip position errors greater than 10 mm were observed in 1.9% in SI, 0.2% in AP, and 0.2% in RL directions, despite respiratory control. Conclusion: Quantitative analysis of surgical clip displacement reflect respiratory motion, setup errors and postoperative change of intraabdominal organ position. Furthermore, position of clips is distinguished easily in verification images. The identification of the surgical clip position may lead to a significant improvement in the accuracy of upper abdominal radiation therapy.

Evaluation of image acquisition using synchrotron radiation in CMOS sensor. (Synchrotron Radiation을 이용한 CMOS sensor image 획득평가)

  • Kim, D.H.;Park, J.K.;Choi, J.Y.;Chang, G.W.;Youn, G.J.;Moon, C.W.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.396-399
    • /
    • 2003
  • In this paper, the purpose is to develop imaging technique of synchrotron radiation using CMOS image sensor. The detector using hybrid method to be research in this lab was used, in order to increase image signal. We made experiments with 1B2 Whitebeam/microprobe beamline in PAL (Pohang Accelerator Laboratory). Phosphor materials such as ZnS:(Ag,Li), ZnS:(Cu,Al), $Y_2O_2S:Eu$ were produced by spin coating on glass. Synchrotron radiation images were acquired and evaluated from monochromatic light from monochromoator in PAL 1B2line. From obtained object and phantom, MTF was 0.15 in ZnS:(Ag,Li) phosphor, and 0.178 in ZnS:( Cu,Al) at 151p/mm. MTFs were unsystematic because thickness of phosphor and uniformity of surface were not optimized. It's expected to improve MTF and the qualify of images as uniformity's optimized.

  • PDF

Clinical Findings of Phenylketonuria Patients in Korea (페닐케톤뇨증의 임상적 고찰)

  • Shin, Ik Soon;Lee, Dong Hwan
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.12 no.1
    • /
    • pp.14-22
    • /
    • 2012
  • Objectives: This study was performed to review clinical manifestations of hyperphenylalaninemia patients in Korean. Methods: 178 cases of hyperphenyalaninemia were diagnosed at department of pediatrics, Soonchunhyang University Hospital from January, 1983 to August. We reviewed DNA analysis, MR imaging, EEG, radiography of the left hand and wrist, bone densitometry (BMD), IQ test of hyperphenyalaninemia patients. Results: Out of 178 cases, 161 cases were diagnosed classic phenylketonuria and 17 cases were diagnosed BH4 deficiency. 122 cases performed DNA analysis. R243Q (10.3%), Y204C (9.9%), and IVS4-1G>A (8.1%) mutations were predominant. 22 cases underwent MR imaging. Varying degrees of symmetrical high signal intensity were noted on T2-weighted sequences in the periventricular deep white matter of 15 cases. 23 cases were performed EEG. 12 cases (52.3%) showed abnormal pattern. EEG abnormalities showed in 11 cases. On lumbar BMD four of 11 cases (36%) showed reduced bone density of more than 1 S.D. in four of 11 cases, bone age was less than chronological age by at least one year. 18 cases were performed IQ test. Mean IQ scores was $84{\pm}21.6$. Among older than 15 years (9 cases), Mean IQ scores was $72{\pm}21.2$. PTPS deficiency was 14 cases, DHPR deficiency was 2 cases, and GTPCH deficiency was 1 case. Conclusion: We confirmed there were varieties of DNA mutations. And MR imaging and EEG were nonspecific in PKU patients. Older children showed lower IQ score. Low phenylalanine diet prevents brain damage in PKU patient. Not only first few years of life but also lifetime, Keeping low phenylalanine diet is important.

  • PDF

Miniscrew Installation Area and Condition on Maxillary Palatal Side (상악구개측 미니스크류 식립위치 및 조건)

  • Lee, Ki-Yeon;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.61-71
    • /
    • 2009
  • Anchorage control is important in orthodontic treatment. Recently miniscrew is widly used as maximum anchorage in orthodontic treatment, and then it is important to install miniscrew safely without damaging adjacent anatomic structure. In a view of Miniscrew's stability, maxilla is unfavorable than mandible, and moreover maxillary soft buccal bone has disadvantage on stability. so palatal area comes into notice for installation area. We measured distance between palatal roots and bone thickness at midpalatal area using 3D computed tomography, and have found following results. 1. On the comparison of distance between palatal roots, the distance between 2nd premolar and 1st molar was significantly longest and the distance between premolars was significantly shortest. 2. Going toward lateral area from midpalatal suture and posterior area from zero point, bone thickness significantly became shorter and shorter. And 5.0mm palatal sagittal plane has more significance decrease of bone thickness than 2.5mm palatal sagittal plane. According to these results, we can conclude that the palatal installation of miniscrew between 2nd premolar and 1st molar is safest. And it is more safe that comes closer to midpalatal suture and to anterior area in regard to incisive canal.

Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c) (Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구)

  • Lee, Dong Hun;Choi, Woo Jun;Jung, Woo Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.80-85
    • /
    • 2017
  • Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients' movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

  • PDF

A Study on Metaverse Construction Based on 3D Spatial Information of Convergence Sensors using Unreal Engine 5 (언리얼 엔진 5를 활용한 융복합센서의 3D 공간정보기반 메타버스 구축 연구)

  • Oh, Seong-Jong;Kim, Dal-Joo;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.52 no.2
    • /
    • pp.171-187
    • /
    • 2022
  • Recently, the demand and development for non-face-to-face services are rapidly progressing due to the pandemic caused by the COVID-19, and attention is focused on the metaverse at the center. Entering the era of the 4th industrial revolution, Metaverse, which means a world beyond virtual and reality, combines various sensing technologies and 3D reconstruction technologies to provide various information and services to users easily and quickly. In particular, due to the miniaturization and economic increase of convergence sensors such as unmanned aerial vehicle(UAV) capable of high-resolution imaging and high-precision LiDAR(Light Detection and Ranging) sensors, research on digital-Twin is actively underway to create and simulate real-life twins. In addition, Game engines in the field of computer graphics are developing into metaverse engines by expanding strong 3D graphics reconstuction and simulation based on dynamic operations. This study constructed a mirror-world type metaverse that reflects real-world coordinate-based reality using Unreal Engine 5, a recently announced metaverse engine, with accurate 3D spatial information data of convergence sensors based on unmanned aerial system(UAS) and LiDAR. and then, spatial information contents and simulations for users were produced based on various public data to verify the accuracy of reconstruction, and through this, it was possible to confirm the construction of a more realistic and highly utilizable metaverse. In addition, when constructing a metaverse that users can intuitively and easily access through the unreal engine, various contents utilization and effectiveness could be confirmed through coordinate-based 3D spatial information with high reproducibility.

Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog (개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가)

  • Shin, Seung-Ho;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2007
  • A 15 kg 6-year-old intact male Jindo dog with a history of a respiratory distress, hindlimb paralysis with necrosed skin of dorsal digit for three weeks was referred to Animal Medical Center, Chonbuk National University. Heartworm infection was identified by kit examination. In plain thoracic radiographs, dilated pulmonary arteries reverse D sign and focal interstitial pattern was compatible with heartworm infection and possible pulmonary thromboembolism. Abdominal radiographs showed poor serosal detail indicating fluid accumulation within peritoneal cavity. No evidence of musculoskeletal abnormalities was found. Ultrasonography presented focal wedge-shaped hyperechogenecity on the both poles of left kidney, weak or absent pulse on the distal to the external iliac artery as well as ascites and irregular liver margin. Multi-organ failure was strongly supposed by blood profile including leukocytosis, anemia, hemoglobinuria bililubinemia, hypoalbuminemia, imbalance of electrolytes, and increased hepatic and renal function values. Interestingly, the glucose level is remarkably lower in pelvic limb compared to thoracic limb. Suspected pulmonary thromboembolism, renal infarction and femoral arterial embolization causing hindlimb paralysis and dermatic necrosis were confirmed by 3D reconstructed CT imaging. Prior to taking a consideration of euthanasia, interventional radiology was experimentally attempted but failed due to not recovered from general anesthesia. Early and accurate diagnosis of thromboembolism is valuable and 3D reconstructed CT images might be very useful to show the correct way to treat effectively.