• Title/Summary/Keyword: 2D Image

Search Result 3,779, Processing Time 0.041 seconds

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.

Magnetic Tunnel Junctions with AlN and AlO Barriers

  • Yoon, Tae-Sick;Yoshimura, Satoru;Tsunoda, Masakiyo;Takahashi, Migaku;Park, Bum-Chan;Lee, Young-Woo;Li, Ying;Kim, Chong-Oh
    • Journal of Magnetics
    • /
    • v.9 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • We studied the magnetotransport properties of tunnel junctions with AlO and AlN barriers fabricated using microwave-excited plasma. The plasma nitridation process provided wider controllability than the plasma oxidization for the formation of MTJs with ultra-thin insulating layer, because of the slow nitriding rate of metal Al layers, comparing with the oxidizing rate of them. High tunnel magnetoresistance (TMR) ratios of 49 and 44% with respective resistance-area product $(R{\times}A) of 3 {\times} 10^4 and 6 {\times} 10^3 {\Omega}{\mu}m^2$ were obtained in the Co-Fe/Al-N/Co-Fe MTJs. We conclude that AlN is a hopeful barrier material to realize MTJs with high TMR ratio and low $R{\times}A$ for high performance MRAM cells. In addition, in order to clarify the annealing temperature dependence of TMR, the local transport properties were measured for Ta $50{\AA} /Cu 200 {\AA}/Ta 50 {\AA}/Ni_{76}Fe_{24} 20 {\AA}/Cu 50 {\AA}/Mn_{75}Ir_{25} 100 {\AA}/Co_{71}Fe_{29} 40 {\AA}/Al-O$ junction with $d_{Al}= 8 {\AA} and P_{O2}{\times}t_{0X}/ = 8.4 {\times} 10^4$ at various temperatures. The current histogram statistically calculated from the electrical current image was well in accord with the fitting result considering the Gaussian distribution and Fowler-Nordheim equation. After annealing at $340^{\circ}C$, where the TMR ratio of the corresponding MTJ had the maximum value of 44%, the average barrier height increased to 1.12 eV and its standard deviation decreased to 0.1 eV. The increase of TMR ratio after annealing could be well explained by the enhancement of the average barrier height and the reduction of its fluctuation.

Development of a vestibulo-ocular reflex measurement system for the study of cybersickness (사이버멀미 경감 연구를 위한 전정안구반사 측정 시스템 개발)

  • Jeon, Hyeonjin;Chang, EunHee;Wendimagegn, Tariku Weldtsadik;Park, Chan Hyun;Jeong, Ji Woon;Kim, Hyun Taek
    • Science of Emotion and Sensibility
    • /
    • v.18 no.1
    • /
    • pp.27-38
    • /
    • 2015
  • Vestibulo-ocular reflex (VOR) is a compensatory response of the extraocular muscles generated by vestibular signals to stabilize images on the retina during head/body movements. It has been reported that mismatches between retinal and vestibular information, which cause motion sickness or cybersickness, modify VOR. To investigate the characteristic changes of VOR in subjects experiencing cybersickness, we developed a low-cost, multi-purpose VOR measurement system using LabVIEW and Arduino. To test the applicability of the system, we performed two experiments. In Experiment 1, horizontal and vertical VORs of four participants were measured using a vestibular autorotation task. In Experiment 2, eight participants were exposed to a virtual navigation to measure changes of VORs as an index of cybersickness. We observed significantly greater head rotations and eye movements while the participants were exposed to the virtual navigation than to a static image. The results suggest that the present system can help understand the psychophysiological mechanisms of cybersickness symptoms.

Automatic Extraction of Eye and Mouth Fields from Face Images using MultiLayer Perceptrons and Eigenfeatures (고유특징과 다층 신경망을 이용한 얼굴 영상에서의 눈과 입 영역 자동 추출)

  • Ryu, Yeon-Sik;O, Se-Yeong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.2
    • /
    • pp.31-43
    • /
    • 2000
  • This paper presents a novel algorithm lot extraction of the eye and mouth fields (facial features) from 2D gray level face images. First of all, it has been found that Eigenfeatures, derived from the eigenvalues and the eigenvectors of the binary edge data set constructed from the eye and mouth fields are very good features to locate these fields. The Eigenfeatures, extracted from the positive and negative training samples for the facial features, ate used to train a MultiLayer Perceptron(MLP) whose output indicates the degree to which a particular image window contains the eye or the mouth within itself. Second, to ensure robustness, the ensemble network consisting of multiple MLPs is used instead of a single MLP. The output of the ensemble network becomes the average of the multiple locations of the field each found by the constituent MLPs. Finally, in order to reduce the computation time, we extracted the coarse search region lot eyes and mouth by using prior information on face images. The advantages of the proposed approach includes that only a small number of frontal faces are sufficient to train the nets and furthermore, lends themselves to good generalization to non-frontal poses and even to other people's faces. It was also experimentally verified that the proposed algorithm is robust against slight variations of facial size and pose due to the generalization characteristics of neural networks.

  • PDF

Weight Control Behaviors, Health-related Quality of Life and Nutritional Status by Overestimation of Body Image among Young Korean Females: Data from the Fifth Korea National Health and Nutrition Examination Survey, 2010-2011 (20·30대 여성의 체형 과대인식에 따른 체중조절행위, 삶의 질, 식행동 및 영양소 섭취상태: 2010-2011년 국민건강영양조사 자료 이용)

  • Park, Seulki;Hyun, Taisun;Lee, Hongmie
    • Korean Journal of Community Nutrition
    • /
    • v.20 no.5
    • /
    • pp.362-374
    • /
    • 2015
  • Objectives: This study was performed to investigate the effects of overestimation of their own body shape on weight control behaviors, mental condition, physical activity, dietary behavior, health-related quality of life, and nutritional status among young Korean females. Methods: A total of 1,514 women aged 20-39 years who are not pregnant and lactating among those who participated in the Fifth Korea National Health and Nutrition Examination Survey (2010~2011), were analyzed and grouped into underestimation (n=120), normal estimation (NE, n=840), and overestimation (OE, n=554), based on their body perception compared to actual percent ideal body weights. Variables were compared between OE group and NE group. Results: The subjects in OE group were significantly younger (29.5 vs. 30.5 years, respectively p < 0.05) and had lower body mass index (20.9 vs. 22.2 respectively, p < 0.01), health-related quality of life measured by EQ-5D (EuroQol-5 Dimension)(0.97 vs. 0.98 respectively, p < 0.05), nutrition adequacy ratio (NAR) of protein (0.91 vs. 0.93 respectively, p < 0.05), phosphorous (0.93 vs. 0.96 respectively, p < 0.05), and iron (0.70 vs. 0.75 respectively, p < 0.01), and index of nutrition quality (INQ) of iron (0.84 vs. 0.89 respectively, p < 0.05) compared to those in the NE group. The results of logistic regression showed that unmarried status (OR 1.32; 1.01~1.72) and severely underweight/underweight status (OR 1.94; 1.01~3.75)/(OR 1.81; 1.34~2.45) were significantly related to the probability of overestimation by the subjects. Significantly more women in OE group practiced fasting, skipping meals, and taking prescribed pills to lose body weights and had skipped breakfast compared to those in the NE group. Conclusions: The results of this study suggested that the Korean young women's distorted perception of own body shape may be associated with undesirable weight control behavior, low quality of life, and lower nutritional status. Therefore, nutrition education for this group should include information on correct body shape perception and its importance.

A Study on the Change of Cavity Area through Groundwater Injection Test under Pavement Cavity (도로하부 공동 내의 지하수 주입 실험을 통한 공동 영역 변화 연구)

  • Kim, Sang Mok;Choi, Hyeon;Yoon, Jin Sung;Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.267-275
    • /
    • 2020
  • Purpose: In this study, GPR exploration equipment, spray vehicles and flow meters, core drill, borehole image processing system(BIPS), 3D cavity imagery equipment, and cavity formatting equipment were used to identify this cavity growth process. Method: A certain amount of water was injected in proportion to the mass of the cavity, and the cavity was observed to expand as the injected water was drained out. The cavity rating change was evaluated by quantitatively evaluating the expansion factors and the speed of growth. Results: According to the results of examining the volume change through injection time - injection flow rate - volume increase for the four experimenters, the volume increase decreased as the injection time increased, and there was no further increase in volume if injected for one hour or so. Conclusion: In addition, the injection test analyzed the volumetric variation to determine whether the cause of the cavity occurrence was the effect of the underground burial in the vicinity of the cavity. Therefore, it was found that the cavity expansion is caused by the repetition of the relaxation soil collapse due to the groundwater flow and the loss of the collapsed soil below the cavity.

Erosion and Sedimentation Monitoring of Coastal Region using Time Series UAV Image (시계열 UAV 영상을 활용한 연안지역 침식·퇴적 변화 모니터링)

  • CHO, Gi-Sung;HYUN, Jae-Hyeok;LEE, Geun-Sang
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.23 no.2
    • /
    • pp.95-105
    • /
    • 2020
  • In order to promote efficient coastal management, it is important to continuously monitor the characteristics of the terrain, which are changed by various factors. In this study, time series UAV images were taken of Gyeokpo beach. And the standard deviation of ±11cm(X), ±10cm(Y), and ±15cm(Z) was obtained as a result of comparing with the VRS measurement performance for UAV position accuracy evaluation. Therefore, it was confirmed that the tolerance of the digital map work rule was satisfied. In addition, as a result of monitoring the erosion and sedimentation changes using the DSM(digital surface model) constructed through UAV images, an average of 0.01 m deposition occurred between June 2018 and December 2018, and in December 2018 and June 2019. It was analyzed that 0.03m of erosion occurred. Therefore, 0.02m of erosion occurred between June 2018 and June 2019. From the topographical change analysis results, the area of erosion and sediment height was analyzed, and the area of erosion and sedimentation was widely distributed in the ±0.5m section. If we continuously monitor the topographical changes in the coastal regions by using the 3D terrain modeling results using the time series UAV images presented in this study, we can support the coastal management tasks such as supplement or dredging of sand.

Development of a Tool to Measure Suffering in Patients with Cancer (암환자의 고통 측정도구 개발에 관한 연구)

  • 강경아
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.6
    • /
    • pp.1365-1378
    • /
    • 1999
  • This study is a methodological research study to develop an instrument to measure in patients with cancer and to test the validity and reliability of the instrument. The research procedure was as follows : 1) The first step was to develop conceptual framework based on a comprehensive review of the literature and in-depth interviews with patients with cancer. This conceptual framework was organized in to three dimensions (the intrapersonal dimension, the significant-other and context related dimension, the transcendental dimension). Initially 59 items were adopted. 2) These items were analyzed through the index of content validity(CVI) and 53 items were selected which met more than 80% on the CVI. 3) The pretest was carried out with 87 patients with cancer. After the pretest results were analyzed by item analysis, 44 items were selected. A second test of content validity was conducted and 6 items were eliminated considering the 80% CVI. 4) To test for reliability and validity, data collection was done during the period from January 25, 1999, to February 26, 1999. The subjects for the test were 160 patients with cancer and 185 healthy persons. analysis, item analysis and multitrait-multimethod method to analyze validity. The findings are as follows : 1) The Cronbach's alpha coefficient for internal consistency was .92 for the total 38 items and .79, .82, .85, for the three dimensions in that order. 2) The item analysis was based on the corrected item to total correlation coefficient( .30 or more) and information about the alpha estimate if this item was dropped from the scale. 3) As a result of the initial factor analysis using principal component analysis and varimax rotation, one item was deleted because of factor complexity (indiscriminate factor loadings). In the secondary factor analysis, 7 factors with eigenvalue of more than 1.0 were extracted and these factors explained 56 percents of the total variance. The seven factors were labeled as 'family relationship', 'emotional condition', 'physical discomfort', 'meaning and goal of life', 'contextual stimuli', 'change of body image', 'guilt feelings'. 4) The convergence effect between this instrument and the life satisfaction scale was identified and there was significant positive correlation(r= .52, p= .00). The discriminant validity between this instrument and the depression scale(CES-D) was tested and there was significant negative correlation(r= -.50, p= .00). The instrument for accessing the suffering of patients with cancer developed in this study was identified as a tool with a high degree of reliability and validity. In this sense, this tool can be effectively utilized for assessment in caring for patients with cancer.

  • PDF

Variation of Dose due to the Wound Electrode of Ionization Chamber (굴곡이 있는 전리함 집전극에 기인한 선량 변화)

  • Lee, Byung-Koo;Kim, Jung-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.11
    • /
    • pp.203-209
    • /
    • 2008
  • Nowadays the risk of radiation is getting more serious, so we must know the exact dose that was irradiated, Because very high radiation dose is used in radiation therapy field. We used the ionization chamber which measure the radiation dose in this study. We tried to know the incorrect result from the distortion of geometric structure of ionization chamber and we studied how to find the distortion of geometric structure of ionization chamber. We used a radio fluoroscopy to find the wound degree of electrode of ionization chamber and a reconstructed 3D CT image to analyze the wound degree of electrode quantitatively. we measured degree of distortion by comparing with absorbed dose of normal electrode and wound electrode. The comparative result is not absolute dosimetry at specific point but relative dosimetry between thats. We measured 4 MV, 10MV photon with same absorbed dose and dose rate. The degree of distortion of wound electrode was totally $5.5{\sim}7.2%$, and there was no difference between two energies. The variation induced from radiation dose to be irradiated and dose rate, and the degree of distortion from wound direction also was almost similar value. We could find that the geometric structure of ionization chamber that can influence a basic measurement of radiation dose can be changed by old usage and inattention of management in this study, especially winding of electrode can be happened, in radiation therapy field, It is very important to keep precise radiation dose quantitatively.