• 제목/요약/키워드: 2D/3D imaging

검색결과 854건 처리시간 0.023초

Quantitative Measurements of 3-D Imaging with Computed Tomography using Human Skull Phantom

  • Kim, Dong-Wook;Kim, Hee-Joung;Haijo Jung;Soonil Hong;Yoo, Young-Il;Kim, Dong-Hyeon;Kim, Kee-Deog
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.506-508
    • /
    • 2002
  • As an advancement of medical imaging modalities and analyzing software with multi-function, active researches to acquire high contrast and high resolution image being done. In recently, development of medical imaging modalities like as Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) is aiming to display anatomical structure more accuracy and faster. Thus, one of the important areas in CT today is the use of CT scanner for the quantitative evaluation of 3-D reconstruction images from 2-D tomographic images. In CT system, the effective slice thickness and the quality of 3-D reconstructed image will be influenced by imaging acquisition parameters (e.g. pitch and scan mode). In diagnosis and surgical planning, the accurate distance measurements of 3-D anatomical structures play an important role and the accuracy of distance measurements will depend on the acquisition parameters such as slice thickness, pitch, and scan mode. The skull phantom was scanned with SDCT for various acquisition parameters and acquisition slice thicknesses were 3 and 5 mm, and reconstruction intervals were 1, 2, and 3 mm to each pitch. 3-D visualizations and distance measurements were performed with PC based 3-D rendering and analyzing software. Results showed that the image quality and the measurement accuracy of 3-D SDCT images are independent to the reconstruction intervals and pitches.

  • PDF

3차원 Confocal Imaging과 생체 영상 분석 (Three Dimensional Confocal Imaging and Biomedical Image Analysis)

  • 이임걸
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.257-261
    • /
    • 1995
  • Confocal laser scanning microscopy (CLSM)는 기존의 coherent or incoherent microscopic imaging 보다 횡축 방향 (lateral direction)으로 고해상도를 가지며, 층과 층 사이를 구분하는 광축 방향 (axial direction)의 optical sectioning에 의해 샘플의 3D 구조를 고해상도로 영상화함으로써 3D 구조 및 생체 기능 분석을 가능하게 해 준다. 본 논문에서는 CLSM에 의한 3D 영상화 원리와 촛점면 부근에서 얻어지는 광세기 분포, 얻어진 2D slice 영상의 시각화 및 응용에 대해 논의된다.

  • PDF

Image and Observer Regions in 3D Displays

  • Saveljev, Vladimir
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.68-75
    • /
    • 2010
  • The relation between light sources and screen cells is considered part of the theoretical model of an autostereoscopic 3D display. The geometry of the image and observer regions is presented, including the cases of single and multiple regions. The characteristic function is introduced. Formulas for the geometric parameters are obtained, including areas and angles. Special attention is drawn to the screen location. The method of transforming the formulas between regions is stated. For multiple regions, geometric dissimilarity was found. This allows the model to be applied in finding the geometric characteristics of multiview and integral-imaging 3D displays.

Integral Imaging Monitors with an Enlarged Viewing Angle

  • Dorado, Adria;Saavedra, Genaro;Sola-Pikabea, Jorge;Martinez-Corral, Manuel
    • Journal of information and communication convergence engineering
    • /
    • 제13권2호
    • /
    • pp.132-138
    • /
    • 2015
  • Enlarging the horizontal viewing angle is an important feature of integral imaging monitors. Thus far, the horizontal viewing angle has been enlarged in different ways, such as by changing the size of the elemental images or by tilting the lens array in the capture and reconstruction stages. However, these methods are limited by the microlenses used in the capture stage and by the fact that the images obtained cannot be easily projected into different displays. In this study, we upgrade our previously reported method, called SPOC 2.0. In particular, our new approach, which can be called SPOC 2.1, enlarges the viewing angle by increasing the density of the elemental images in the horizontal direction and by an appropriate application of our transformation and reshape algorithm. To illustrate our approach, we have calculated some high-viewing angle elemental images and displayed them on an integral imaging monitor.

전기비저항 토모그래피에 의한 파쇄대 및 터널의 3차원 영상화 (Imaging of Fractures and Tunnel by 3-D ERT)

  • 이명종;김정호;손정술
    • 지구물리와물리탐사
    • /
    • 제11권4호
    • /
    • pp.302-309
    • /
    • 2008
  • 3차원 전기비저항 토모그래피는 토목 및 수리지질분야 등에서 매우 고분해능의 지하구조 영상을 획득할 수 있는 강력한 성능을 제공한다. 이 논문에서는 특히 3차원 이상대가 주탐사 대상인 경우에 대한 3차원 전기비저항 토모그래피의 두가지 성공적 응용사례를 소개한다. 첫번째 예는 수리지질분야에의 응용을 위한 파쇄대 영상화 사례로서, 여기서는 시추공의 공곡변화가 중요한 문제로 대두되었으며 이에 따라 시추공 공곡변화를 토모그래피 역산과정에 포함함으로써 파쇄대의 3차원 영상을 획득할 수 있었다. 두번째 예에서는 크기 $2m{\times}2m$의 내부가 비어있는 터널의 영상화 문제를 다루었으며, 3차원 토모그래피를 통하여 터널의 발달을 3차원 공간상에 영상화할 수 있었다. 이들 예로부터 3차원 전기비저항 토모그래피가 3차원 지하구조 영상화에 강력한 성능을 보임과 아울러 특히 3차원 이상대인 파쇄대, 공동 또는 터널의 영상화에 더욱 향상된 영상화 능력을 제공할 수 있음을 보였다.

안테나배열을 이용한 콘크리트부재 내부의 비파괴시험과 영상화방법 개발 (Subsurface Imaging Technology For Damage Detection of Concrete Structures Using Microwave Antenna Array)

  • 김유진;최고일;장일영
    • 한국방재학회 논문집
    • /
    • 제5권2호
    • /
    • pp.1-8
    • /
    • 2005
  • 콘크리트 구조물 내부 결함이나 철근 위치를 탐지하기 위하여 초단파를 이용하는 비파괴 시험방법이 구조물 안전진단 분야에서도 최근 관심을 불러일으키고 있다. 본 연구의 목적은 기 개발된 2차원 영상화 방법을 확장하여 3차원 영상처리방법을 개발하는 것이다. 그 방법으로 콘크리트 구조물 내의 결함을 탐지하기 위한 안테나를 구성, 수치적 초점조절시스템을 이용하여 송신부와 수신부의 초점을 동시 조절하여 구조물 내부의 모든 부분을 검색하였다. 또한 다중주파수 방식을 이용, 데이터의 오류를 제거하고 해상도를 향상시켜 구조물 내부의 결함이나 내부모습을 탐지할 수 있는 3차원 영상장치를 개발하고자 하였다. 실험 결과, 데이터 오류를 줄이는 다중주파수방식에 의하여 재현된 영상의 정확성을 검증하고, 주파수 조절방법에 의하여 $4{\times}4$ 안테나배열을 설계함으로써 5.2 GHz에서 주파수대역의 우수한 투과성능을 입증하였다. 즉 본 연구에서 개발된 슬롯안테나는 파동의 방사기능과 주파수대역의 넓이 등에서 구조부재의 결함탐지에 이용될 수 있음을 검증하였다.

Evaluation of Morphological Changes in Degenerative Cartilage Using 3-D Optical Coherence Tomography

  • Youn, Jong-In
    • Journal of the Optical Society of Korea
    • /
    • 제12권2호
    • /
    • pp.98-102
    • /
    • 2008
  • Optical Coherence Tomography (OCT) is an important noninvasive medical imaging technique that can reveal subsurface structures of biological tissue. OCT has demonstrated a good correlation with histology in sufficient resolution to identify morphological changes in articular cartilage to differentiate normal through progressive stages of degenerative joint disease. Current OCT systems provide individual cross-sectional images that are representative of the tissue directly under the scanning beam, but they may not fully demonstrate the degree of degeneration occurring within a region of a joint surface. For a full understanding of the nature and degree of cartilage degeneration within a joint, multiple OCT images must be obtained and an overall assessment of the joint surmised from multiple individual images. This study presents frequency domain three-dimensional (3-D) OCT imaging of degenerative joint cartilage extracted from bovine knees. The 3-D OCT imaging of articular cartilage enables the assembly of 126 individual, adjacent, rapid scanned OCT images into a full 3-D image representation of the tissue scanned, or these may be viewed in a progression of successive individual two-dimensional (2-D) OCT images arranged in 3-D orientation. A fiber-based frequency domain OCT system that provides cross-sectional images was used to acquire 126 successive adjacent images for a sample volume of $6{\times}3.2{\times}2.5\;mm^3$. The axial resolution was $8\;{\mu}m$ in air. The 3-D OCT was able to demonstrate surface topography and subsurface disruption of articular cartilage consistent with the gross image as well as with histological cross-sections of the specimen. The 3-D OCT volumetric imaging of articular cartilage provides an enhanced appreciation and better understanding of regional degenerative joint disease than may be realized by individual 2-D OCT sectional images.

3T 자기공명영상 장비에서 신생아 뇌의 T1 강조 영상: 스핀에코, 고속 역전회복, 자기화 삼차원 경사에코기법의 비교 (T1-weighted MR Imaging of the Neonatal Brain at 3.0 Tesla: Comparison of Spin Echo, Fast Inversion Recovery, and Magnetization-prepared Three Dimensional Gradient Echo Techniques)

  • 정지영;유소영;장경미;어홍;이정희;김지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제11권2호
    • /
    • pp.87-94
    • /
    • 2007
  • 목적: 3T 장비의 신생아 뇌자기공명영상에서 T1 강조 고속 역전회복기법 (fast inversion recovery, FIR)과 자기화 삼차원 경사에코기법, (magnetization-prepared three dimensional gradient echo sequence, 3D GRE)을 스핀에코기법 (SE)과 비교하여 유용성을 알아보는 데 있다. 대상 및 방법: 20명의 신생아에서 T1 강조 SE, FIR, 그리고 3D GRE의 신호소음비 (SNR)와 대조소음비 (CNR)를 측정하고 시각적으로 회백질-백질 구별, 수초화 인식, 인공음영 발생을 점수화하여 비교하였다. 각 영상기법의 CNR 비교에는 Wilcoxon signed ranked test를 사용하였다. 결과: 세가지 영상기법 중 3D GRE가 가장 우수한 SNR을 보였고 CNR은 FIR과 3D GRE 모두 SE보다 우수하였으며 FIR보다 3D GRE가 더 우수하였다. 회백질-백질의 구분과 수초화 유무 역시 스핀에코보다 FIR과 3D GRE에서 더 잘 보였다. 그러나 3D GRE는 움직임에 의한 인공음영이 많았고 FIR에서 혈류에 의한 혈관의 고신호강도가 자주 발견되었다. 결론: 3T 장비에서 신생아 뇌영상을 얻을 때 FIR과 3D GRE 기법은 SE보다 좋은 T1 강조영상을 제공할 것으로 기대된다.

  • PDF

2D 혈관조영술에서 직접 측정한 혈관 직경과 MR 영상에서 단면적 기반 환산 직경의 비교 분석 (Comparative Analysis between Directly Measured Diameter in 2D Angiography and Cross-Sectional Area-Converted Diameter in MR Image)

  • 이기백;김미현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.427-433
    • /
    • 2023
  • This study aimed to quantitatively compare the diameters measured directly from the coronal plane or sagittal plane of 2D digital subtraction angiography (DSA) and the cross-sectional area-converted diameters calculated from contrast-enhanced MR (CE-MR) imaging. A retrospective analysis was conducted on 20 patients who underwent both 2D DSA and CE-MR imaging. Firstly, the venous diameters of the superior sagittal sinus (SSS) and transverse sinus (TS) were directly measured from 2D DSA. Subsequently, the axial planes for SSS diameter and the sagittal plane for TS in CE-MR imaging were utilized to calculate cross-sectional area-based converted diameters. The numerical values obtained from 2D DSA and CE-MR imaging were compared pairwise at each location. For SSS, the diameter measured by 2D DSA was 27% larger than the conversion-based diameter from CE-MR imaging (9.8±1.4 mm vs. 7.1±1.3 mm, P<0.05). Similarly, for the right TS, the difference was 16% (8.8±3.2 mm vs. 7.4±2.0 mm, P<0.05), and for the left TS, the difference was 22% (8.4±2.8 mm vs. 6.6±1.3 mm, P<0.05). In conclusion, the diameter measured directly in conventional 2D DSA may be larger than the diameter converted based on the cross-sectional area. Therefore, when selecting the size of the stent, it is crucial to make precise determinations while keeping this fact in mind.

2차원 및 3차원 전기비저항 탐사를 이용한 제당 누수 조사 (Dam seepage investigation using two- and three-dimensional resistivity surveys)

  • 이명종;김정호;송윤호;정승환
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2000년도 정기총회 및 특별심포지움
    • /
    • pp.41-53
    • /
    • 2000
  • 제당의 누수부위 조사를 위하여 전기비저항 탐사가 많이 이용되고 있는 바, 전기비 저항 탐사를 이용한 누수부위의 파악은 주로 제체 내 불균질대의 규명을 통하여 이루어지고 있다. 본 연구에서는 제당의 누수부위 탐지를 위한 전기비저항 탐사의 3차원 유한요소 수치모델링을 수행하고 이 결과를 이용하여 제당 누수부위 조사를 위한 2차원 및 3차원 전기비저항 탐사 방법론 및 자료의 해석에 대하여 고찰하였다. 제체의 형상과 전기비저항 구조는 근본적으로 3차원이므로 종래의 2차원 전기비저항 탐사에 비하여 비록 격자상의 측선 배열을 적용할 수 없더라도 3차원적으로 탐사를 수행하고 이를 해석함으로써 좀 더 정확한 제체하부의 영상화가 가능함을 보였다.

  • PDF