• Title/Summary/Keyword: 28-pulse diagnosis

Search Result 35, Processing Time 0.028 seconds

UV Detecting according to Corona Discharge Intensity using UV Sensor (자외선 센서를 이용한 코로나 방전 강도에 따른 자외선 검출)

  • Kwag, Dong-Soon;Kim, Young-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.3
    • /
    • pp.78-83
    • /
    • 2014
  • To minimize the financial loss due to power facility malfunction, on-line diagnostic techniques are required to grasp any abnormal state of facilities in the live line as well as devices to diagnose abnormal states of power facility in an easy and prompt manner. This study aims to develop a portable UV detecting system by means of UV sensors for easier and efficient inspection of the degradation state of power facility in a long distance. Accordingly, it includes a simulation of corona discharges that may occur due to degradation of power facility and detection of ultraviolet pulse generation depending on the corona discharge intensity and measuring distance in application of UV sensors. Additionally, the optimal algorithm is determined for its application to the system's degradation diagnosis program based on the measured experiment data.

Clinical Features of Critical Congenital Heart Disease in Term Infants with Hypoxemia: A Single-Center Study in Korea

  • Choi, Eui Kyung;Shin, Jeong Hee;Jang, Gi Young;Choi, Byung Min
    • Neonatal Medicine
    • /
    • v.25 no.4
    • /
    • pp.137-143
    • /
    • 2018
  • Purpose: This study was performed to determine the clinical features of full-term infants with hypoxemia detected by pulse oximetry and to establish the diagnosis of critical congenital heart disease (CCHD). Methods: We retrospectively reviewed the medical records of neonates who had been admitted to the neonatal intensive care unit within 2 weeks of birth at Korea University Ansan Hospital between January 2013 and October 2017 (n=450). We classified these neonates based on the presence of hypoxemia at admission and investigated neonatal characteristics, initial symptoms, echocardiographic findings, and final diagnosis associated with hypoxemic diseases. Results: Of 450 term infants, 265 infants (58.9%) were identified hypoxemia by pulse oximetry at admission. The most common symptoms of them were cyanosis and tachypnea. Among them, 80.1% of infants (214/265) were diagnosed with respiratory tract disease and 8.3% of infants (22/265) had congenital heart disease. Thirteen infants (13/265, 4.9%) had CCHD and were treated with urgent surgery or transcatheter intervention within 28 days of birth. Majority of infants with respiratory tract disorder were transferred from hospital immediately after birth, but 46.1% of infants (6/13) with CCHD remained asymptomatic after birth and were admitted after 48 hours after birth. In addition, other hypoxemic illnesses were identified as neonatal infectious and neurological diseases. Conclusion: This study showed the importance of assessment in neonates with hypoxemia, including those diagnosed with CCHD. The possibility of CCHD should be considered in the differential diagnosis in neonates demonstrating hypoxemia after 48 hours of birth. A larger prospective study is needed to assess the effectiveness and outcomes of pulse oximetry for neonatal screening in Korea.

The Relationship between Pulse Pattern and NIHSS Score in Early Stroke Patient;Multi Center Trials (초기 중풍 환자에 있어서 맥상(脈象)과 NIHSS과의 상관성 연구;다기관 임상연구)

  • Ma, Mi-Jin;Gang, A-Mi;Choi, Dong-Jun;Han, Chang-Ho;Lee, Won-Chul;Jun, Chan-Yong;Cho, Ki-Ho;Choi, Sun-Mi
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.4
    • /
    • pp.727-732
    • /
    • 2007
  • Objectives : This study investigated using National Institutes of Health Strokes Scale in acute and subacute stroke patients and evaluated relativity of pulse pattern to NIHSS. Methods : 104 acute and subacute stroke patients were selected from 4 oriental medical hospitals from April 2007 to May 2007. The patients were admitted to hospital within 1 month after stroke. Pulse feeling diagnosis was done by oriental medical doctor and classified into 7 subtypes. Results : There were significant results statistically between slow/rapid pulse and NIHSS score in the male group; in the female group, there were no significant results statistically but the results showed that slow pulse has lower NIHSS score than rapid pulse. Patients with surging pulse had lower NIHSS score than the other patients. Another pulse pattern had no relativity to NIHSS score.

  • PDF

Estimation of Compressive Strength of Reinforced Concrete Vertical and Horizontal Members Using Ultrasonic Pulse Velocity Method (초음파속도법을 이용한 철근콘크리트 수직 및 수평부재의 압축강도 추정)

  • Hong, Seonguk;Lee, Yongtaeg;Kim, Seunghun;Kim, Jonghyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.6
    • /
    • pp.197-205
    • /
    • 2018
  • Recently, remodeling is increasing due to aging of buildings. Therefore, the importance of quality control of structures has been raised, and interest in safety diagnosis and evaluation of structures has been increasing. In order to accurately diagnose old buildings, a diagnostic evaluation technique is needed to evaluate the defects of structures in advance. In addition, as the safety diagnostic criteria for reconstruction are improved and the weight of structural safety is increased, researches on safety diagnosis techniques of structures that are faster and more reliable are needed. In this study, we tried to estimate the compressive strength by examining the correlation between ultrasonic pulse velocity and compressive strength of a 1 story structure consisting of vertical and horizontal members of reinforced concrete using ultrasonic pulse velocity method, which is one of the nondestructive testing methods. The purpose of this study is to examine the applicability in the field. As a result, the estimated average error rate of the compressive strength of the structure using the ultrasonic pulse velocity method was 28.7%, which confirmed the applicability in the field. However, in order to increase the accuracy of the estimation, the necessity of the reliable diagnostic method using the composite nondestructive testing method was confirmed.

An investigative report on the clinical use of traditional diagnosis modalities among Korean Medicine Doctors (현직 한의사의 한의진단 현황 조사 보고)

  • Jang, Jaesoon;Cho, Seungmo;Kim, Kiwang
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.2
    • /
    • pp.156-168
    • /
    • 2013
  • Objectives Although there have been someone who pointed out declining tendency of pure traditional diagnosis, there are no objective survey results on present state of diagnosis among Korean Medicine Doctors (KMDs). So we did a descriptive survey study to show traditional diagnostic modality usage among them. Materials and methods: 73 samples of responded questionnaire in Busan area were collected and descriptively studied. Results (1) U code (in KCD-6) usage showed low level (28.7%). (2) Diagnostic apparatuses for traditional medicine are rarely used. For example, pulse diagnosis machine was reported to be used only by 9.7 % of KMDs. (3) KMDs still prefer the treatment based on pattern identification and symptomatic therapy rather than treatments based on disease identification of modern biomedicine. Conclusion Overall, the portion of pattern identification is still high among KMDs, some kind of diagnostic methods which support pattern identification showed lack of usage.

Study on Cold-Heat Pattern Identification in Hypertensive Patients with Antihypertensive Agents (항고혈압제제를 복용 중인 성인 고혈압 환자의 한열 특성에 관한 연구)

  • Yang, Na-Rae;Han, Chang-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.3
    • /
    • pp.267-277
    • /
    • 2013
  • Objectives : The aim of this study was to investigate the correlation between Cold-Heat pattern tendency and demographic traits, physical character, and vital signs in hypertensive patients taking anti-hypertensive agents. Methods : 28 hypertensive patients 30 to 69 years old were recruited. We assessed their general characteristics, physical characteristics (height, weight, waist circumference, etc.), vital signs without respiratory rate (blood pressure, pulse rate, temperature) and administered a Cold-Heat pattern questionnaire. After that, we analyzed statistical data on separate groups according to Cold-Heat characteristics or other criteria. Results : 1. Heat group patients had statistically higher scores in waist, body mass index (BMI), waist circumference and pulse rate. 2. Over weighted group patients had statistically lower scores in cold Pattern Identification. 3. Higher BMI group (above 23/25) patients had statistically significantly higher Heat scores and lower Cold scores, higher waist circumference group patients had lower Cold scores. Conclusions : From the above result in hypertensive patients taking hypertensive agents, Heat group had a obesity tendency and the inverse is also valid. Later, progressed study based on more samples and varied data will contribute to diagnosis the Cold-heat Pattern identification in hypertensive patients.

A study on the method of Macjin(脈診) in The Whang Di Nei Qing(黃帝內徑) (황제내경(黃帝內徑)에 나타난 맥진법(脈診法)에 관한 연구(硏究))

  • Jang, Yong Woo;Lim, Jin Seok
    • Journal of Korean Medical classics
    • /
    • v.11 no.2
    • /
    • pp.146-168
    • /
    • 1998
  • This thesis is a study on the diagnostic theory and methods of Macjin(checking of pulse) as described in the Whang Di Nei Qing. There are four methods of Macjin in this text, namely: Dong Macjin(動脈法), Sam Bu Gu Who Macjin(三部九脈診). In Young Gi Gu Macjin(人迎氣口脈診法), Nei Qing's Gi Gu Macjin(內徑의 氣口脈法). Each method developed in it's own way, but they are all closely related and became the basis of today's Macjin. I examined the methods of Macjin in the Whang Di Nei Qing from a perspective of "change". The main questions of this study are: "What brought about the development of the different methods?". "How do the methods differ?", and "how did these methods evoke into today's Macjin?". The method of Macjin generated spontaneously from the observation and treatment of disease. Dong Macjin was the first method developed and became the basis of subsequent forms of Macjin. The accumulation of medical knowledge and the influence of oriental philosophy fueled the evolution of Macjin. Chronologically, Macjin methods developed starting with Dong Macjin and eventually into Sam Bu Gu Who Macjin. In Young Gi Gu Macjin, and Nei Qing's Gi Gu Macjin. The different methods of Macjin vary in how many pulse points are checked, and were established with simplicity and effectiveness in mind. Dong Macjin involves the checking the whole body. Sam Bu Gu Who Macjin involves nine points. In Young Gi Gu Macjin involves four points. and Nei Qing's Gi Gu Macjin involves two. In it's early development, the checking of a patient's pulse was used to diagnose only localized disorders in comparison with symptoms. It evolved with Oh Jang Mad(五臟脈, five main types of pulse) to be able to check internal organs with the introduction of Nei Qing's Gi Gu Macjin. After the division of Chon Kwan Chuck(寸關尺), it evolved further to be able to make a detailed diagnosis by using the result of pules checks. Nowadays, we can make 28 forms of diagnostic indices from these development. In conclusion, Macjin can be used practically and effectively in the diagnosis of disease. In using three methods of Macjin(In Young Gi Gu Macjin, Nei Qing's Gi Gu Macjin, and today's Gi Gu Macjin, which can determine the whole body's Siate of well-being) in conjunction with Dong Macjin(which helps pinpoint the localized disorder), an exact diagnosis can be obtained. I strongly feel that we should acquire objectivity by accommodating Macjin with modern methods of medicine.

  • PDF

Effects of the mascara and eye shadow on theMR image distortion (자기공명영상 왜곡에서 마스카라와 아이섀도의 영향)

  • Lee, Hyun-Yong;Shin, Oun-Jae;Park, Byung-Rae
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.25-32
    • /
    • 2005
  • Purpose : To evaluate the degree of the artifact which is caused by the mascara and the eye shadow when acquiring MR images and compare the difference of the image distortion according to the change of various pulse sequence. Material and Method : The popular domestic mascara and eye shadow products were selected from three different companies respectively and divided into two groups mascara (M1, M2, M3 ), eye shadow (E1, E2, E3). Self-designed quadrature type saddle coil which has 4 cm inside diameter, 8 cm length and which is for both Tx and Rx was used. MR image was acquired respectively after applying the mascara to the tape from study 1, the eye shadow to the tape from study 2 and adding the eye shadow to the mascara from study 3. The FSE(fast spin echo), the SE(spin echo), the GE(gradient echo) were used as pulse sequences. The degree of the image distortion which was measured from each sequence was analyzed in quality and quantity. Result : The mascara and the eye shadow caused the artifacts to the MR images partially and induced the image distortion. There was a little difference in terms of the degree of artifact according to the change of pulse sequence. From the study 3 in which the eye shadow was applied to the mascara, on the axial plane image, the width of artifact was 16.73 mm in the GE pulse sequence, 6.64 mm in the SE pulse sequence, and 6.19 mm in the FSE pulse sequence. The degree of the artifact appeared highly in order of the GE, the SE and the FSE. On the sagittal plane image, the length of artifact was 22.84 mm in the GE, 17.81 mm in the SE and it appeared highly with the SE and the FSE technique order. Conclusion : When examining the eyeball and the brain of a woman with the mascara and the eye shadow, we have to consider that the artifact caused by them can have an effect on the image diagnosis. We concluded that it is more suitable for a brain and a eyeball T2 emphasizing image to use the FSE technique than the GE technique.

  • PDF

Clinical Study of Neck Base Injury (경저부 혈관손상의 임상적 고찰)

  • 우종수
    • Journal of Chest Surgery
    • /
    • v.11 no.4
    • /
    • pp.378-384
    • /
    • 1978
  • Injuries to the major vessels in the thoracic inlet require early recognition and expedient operative approach. Delayed diagnosis difficulties encountered in the operative exposure of the region are the major factors limiting successful management. This report is a review of 13 patients with vascular injuries to the neck base who were managed at Busan National University Hospital from March 1975 to September 1978 about 3 years and 6 months. The important clinical problems are delineated with emphasis on the technical aspects of operative management. 1] Among 13 cases, 8 cases were male 5 cases were female. 2] Of 28 vascular injuries, subclavian axillary vascular injuries were 22 [78%]. Stab wound was the cause in 70% of these patients. 3] Without extension 7 cases[53.8%] were managed successfully with supraclavicular, and axillary incision. Posterolateral thoracotomy one of extending 4 cases, 2 cases were used right musculoskeletal flap for management of proximal part of the subclavian artery and innominate vessel, 2 cases were used left supraclavicular incision with anterolateral thoracotomy for management of left proximal subclavian artery. One Expired. 4] Repair of vascular injury was accomplished by lateral suture of debridement and end-to end anastomosis in 17[74%]. Autogenous vein was used one for interposition graft. Ligation was required 2 arterial, 6 venous injuries. Of 8 cases which were pulseless preoperatively, 5 cases were able to palpable distal pulse. 5] Post operative complications occurred 50%. Complication of vasular repair was rare. The majority was neurologic deficit (33.3%).

  • PDF

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.