• 제목/요약/키워드: 2.4GHz

검색결과 2,429건 처리시간 0.026초

(Mg1-xNix)(Ti0.95(Mg1/3Ta2/3)0.05)O3 세라믹스의 마이크로파 유전 특성 (Microwave Dielectric Properties of (Mg1-xNix)(Ti0.95(Mg1/3Ta2/3)0.05)O3 Ceramics)

  • 김주혜;김시현;김응수
    • 한국재료학회지
    • /
    • 제33권8호
    • /
    • pp.330-336
    • /
    • 2023
  • The effects of Ni2+ substitution for Mg2+-sites on the microwave dielectric properties of (Mg1-xNix)(Ti0.95(Mg1/3Ta2/3)0.05)O3 (0.01 ≤ x ≤ 0.05) (MNTMT) ceramics were investigated. MNTMT ceramics were prepared by conventional solid-state reaction. When the MgO / TiO2 ratio was changed from 1.00 to 1.02, MgTi2O5 was detected as a secondary phase along with the MgTiO3 main phase in the MNTMT specimens sintered at 1,400 ℃ for 4h. For the MNTMT specimens with MgO / TiO2 = 1.07 sintered at 1,400 ℃ for 4h, a single phase of MgTiO3 with an ilmenite structure was obtained from the entire range of compositions. The relative density of all the specimens sintered at 1,400 ℃ for 4h was higher than 95 %. The quality factor (Qf) of the sintered specimens depended strongly on the degree of covalency of the specimens, and the sintered specimens with x = 0.01 showed the maximum Qf value of 489,400 GHz. The dielectric constant (K) decreased with increasing Ni2+ content because Ni2+ had a lower dielectric polarizability (1.23Å3) than Mg2+ (1.32Å3). As Ni2+ content increased, the temperature coefficient of resonant frequency (TCF) improved, from -55.56 to -21.85 ppm/℃, due to the increase in tolerance factor (t) and the lower dielectric constant (K).

G-band (183 GHz) 수증기 라디오미터의 가강수량 특성과 품질 관리 (Characteristics and Quality Control of Precipitable Water Vapor Measured by G-band (183 GHz) Water Vapor Radiometer)

  • 김민성;구태영;김지형;정승필;김부요;권병혁;이광재;강명훈;양지휘;이철규
    • 한국지구과학회지
    • /
    • 제43권2호
    • /
    • pp.239-252
    • /
    • 2022
  • 국내에서 처음으로 도입한 기상 항공기에 탑재한 G-band 수증기 라디오미터(GVR) 관측으로 산출된 가강수량의 품질 관리 방법을 제안하였다. GVR 빔의 연직 최단 경로 자료만 사용하기 위해 기상 항공기의 자세 정보(pitch와 roll 각도)를 활용하였고, GVR 가강수량이 20 mm 이상의 자료를 제거하는 방법을 품질 관리에 적용하였다. GVR 가강수량이 20 mm 이상으로 증가할 때, 웜로드(Warm load) 평균 전력과 스카이로드(Sky load) 평균 전력의 차이가 0에 가까이 수렴하는 특성을 확인하였고, 이는 COMS (Communication, Ocean and Meteorological Satellite)의 운형, 운정고도, 운량자료와 구름통합관측기기(CCP), 강수입자 측정기(PIP)로 측정된 강수 및 구름 입자 크기로 확인한 하층운과 중층운에 의한 높은 밝기온도 때문으로 판단된다. 구름 많은 날의 품질 관리 적용 전후의 GVR 가강수량을 LDAPS (Local Data Assimilation and Prediction System) 가강수량과 정량적으로 비교하였는데 RMSD (Root Mean Square Difference)는 2.9 mm에서 1.8 mm로 감소하였고, KLAPS (Korea Local Analysis and Prediction System)와의 RMSD는 5.4 mm에서 4.3 mm로 감소하여 향상된 정확도를 보였다. 또한 품질 관리를 적용한 GVR 가강수량과 드롭존데 가강수량 관측 자료을 활용하여 COMS 가강수량과도 정량적으로 비교평가함으로써 본 연구에서 제안한 GVR 가강수량의 품질 관리 방법의 유효성을 확인하였다.

Cascode 하모닉 발생기를 이용한 V-band MIMIC Quadruple Subharmonic 믹서 (V-band MIMIC Quadruple Subharmonic Mixer Using Cascode Harmonic Generator)

  • 안단;이문교;진진만;고두현;이상진;김성찬;채연식;박형무;신동훈;이진구
    • 대한전자공학회논문지TC
    • /
    • 제42권5호
    • /
    • pp.55-60
    • /
    • 2005
  • 본 논문에서는 cascode 하모닉 발생기를 이용하여 V-band MIMIC (Millimeter-wave Monolithic Integrated Circuit) quadruple subharmonic 믹서를 설계 및 제작하였다. 고변환 이득 특성을 위하여 cascode 하모닉 발생기를 제안하였다. 제안된 cascode 하모닉 발생기는 기존의 multiplier 구조의 비해 평균 2.9 dB 및 최대 4 dB의 높은 4차 하모닉 출력 특성을 나타내었다. 제작된 V-band subharmonic 믹서의 측정결과 14.5 GHz LO 신호를 13 dBm의 크기로 입력하였을 때 3_4 dB의 높은 변환이득 특성을 얻었다. 또한 -53.6 dB의 LO-to-IF, -46.2 dB의 우수한 LO-to-RF 격리 특성을 나타내었다. 제작된 밀리미터파 subharmonic 믹서는 기존에 발표된 밀리미터파 대역의 subharmonic 믹서에 비해 우수한 변환이득 특성을 나타내었다.

전자파 조사 흰쥐 간조직의 Mixed Function Oxidase System과 산화적 손상에 미치는 Catechin의 영향 (Effects of Catechin on Mixed Function Oxidase System and Oxidative Damage in Rat Liver Exposed to Microwave)

  • 김미지;이준하;이순재
    • Journal of Nutrition and Health
    • /
    • 제34권3호
    • /
    • pp.299-305
    • /
    • 2001
  • The purpose of this study was to investigate the effects of catechin on the changes of microsomal mixed function oxidase(MFO) system and oxidative damage in rat liver exposed to microwave. Sprague-Dawley male rats weighing 200$\pm$10g body weight were randomly assigned to one normal and microwave exposed groups: microwave exposed groups were divided three groups: catechin free diet(MW) group, 0.25% catechin(MW+0.25C) group and 0.5% catechin(MW+0.5C) group to the levels of dietary catechin supplementation. The rats were irradiated with microwave at frequency 2.45GHz for 15 min and then the changes pattern of mixed function oxidase system and oxidative damage were investigated for 16 days. The activity of XOD in MW group was increased from 4 day to 8 days after irradiation, compared to normal group and decreased to the level of normal group 16 days. But catechin supplementation group were maintained to the normal level. The contents of cytochrome P(sub)450 and NADPH cytochrome P(sub)450 reductase activities in liver of MW group was increased from 4 day to 8 day after irradiation, compared to normal group and decreased to the level of normal group at 16 day. But catechin supplementation group were recovered to the normal level. The contents of superoxide radical in liver of MW group was increased 1.28, 1.25, 1.17 fold of normal group at 4,6 and 8 days days after irradiation. respectively, but catechin supplementation group were maintained the normal level. The contents of lipifuscin in liver have a same tendency in superoxide radical contents. These result suggested that the supplementation of catechin have control the mixed function oxidase system and oxidative damage and that may help to recover tissues from microwave damage. (Korean J Nutrition 34(3) : 299~305, 2001)

  • PDF

홈 네트워크에서의 댁내외 기기들의 동적 바인딩 시스템 설계 및 구현 (Design and Implementation of Dynamic Binding System among the Devices Located in Inside and Outside of Home Networks)

  • 이재현;권경희
    • 한국콘텐츠학회논문지
    • /
    • 제6권12호
    • /
    • pp.169-176
    • /
    • 2006
  • 홈 네트워크은 주택건축 시점에 건축물의 내장시스템을 중심으로 구축되기 때문에 건축 후 새롭게 구입한 기기와의 네트워크 호환성을 보장하지 못한다. 본 논문에서는 댁내의 기기를 통제하기 위해 댁내 외 기기와 효과적으로 연결할 수 있는 동적인 바인딩 시스템(Dynamic Binding System:DBS)을 제안한다. DBS는 WPAN(Wireless Personal Area Network)에서 동작하는 ZigBee 바인딩 기술을 기반으로 댁외 모바일 기기와 댁내 기기와의 연결을 시도하였다. 본 연구를 위한 시스템 구성으로는, 홈 서버에 프록시 서버와 location 서버가 위치하고 댁내의 기기들은 tinyOS 가 탑재된 telos보드로 구성하였으며, 모바일 기기는 에뮬레이터로 구현하였다. 댁내의 통신은 ZigBee에서 사용하는 IEEE 802.15.4 (2.4GHz)프로토콜을 이용하고, 그 외는 TCP/IP를 이용했다. DBS는 댁내 기기들이 주소형식에 상관없이 댁내 외 기기와 연결되는 것을 용이하게 하였다. 또한 흠 네트워크로 댁내 기기가 새로이 진입될 경우, 기기간 메시지교환을 통해 자동으로 인식될 수 있도록 하였다.

  • PDF

A Broadband High Gain Planar Vivaldi Antenna for Medical Internet of Things (M-IoT) Healthcare Applications

  • Permanand, Soothar;Hao, Wang;Zaheer Ahmed, Dayo;Falak, Naz;Badar, Muneer;Muhammad, Aamir
    • International Journal of Computer Science & Network Security
    • /
    • 제22권12호
    • /
    • pp.245-251
    • /
    • 2022
  • In this paper, a high gain, broadband planar vivaldi antenna (PVA) by utilizing a broadband stripline feed is developed for wireless communication for IoT systems. The suggested antenna is designed by attaching a tapered-slot construction to a typical vivaldi antenna, which improves the antenna's radiation properties. The PVA is constructed on a low-cost FR4 substrate. The dimensions of the patch are 1.886λ0×1.42λ0×0.026λ0, dielectric constant Ɛr=4.4, and loss tangent δ=0.02. The width of the feed line is reduced to improve the impedance bandwidth of the antenna. The computed reflection coefficient findings show that the suggested antenna has a 46.2% wider relative bandwidth calculated at a 10 dB return loss. At the resonance frequencies of 6.5 GHz, the studied results show an optimal gain of 5.82 dBi and 85% optimal radiation efficiency at the operable band. The optometric analysis of the proposed structure shows that the proposed antenna can achieve wide enough bandwidth at the desired frequency and hence make the designed antenna appropriate to work in satellite communication and medical internet of things (M-IoT) healthcare applications.

강자성공명을 이용한 $Co_{84}\;Hf_{16}$ 박막의 자기적 성질 연구 (The Magnetic Properties of $Co_{84}\;Hf_{16}$ Thin Films by FMR)

  • 김기현;장재호;김영호
    • 한국자기학회지
    • /
    • 제7권4호
    • /
    • pp.191-195
    • /
    • 1997
  • DC magnetron sputtering 방법에 의해 $Co_{84}$H $f_{16}$ 박막 (1300 .angs. , 2150 .angs. )을 제작하였다. 박막의 자기적 특성을 조사하기 위해서 J-band (7.42 GHz) 마이크로파 영역의 강자성 공명 (ferromagnetic resonance) 장치를 이용하였다. 측정된 공명 흡수선의 주 모드(main mode)로부터 계산된 분광학적 분리상수 g 값은 1300 .angs. , 2150 .angs. 일 때 각각 2.06과 2.07이었으며, 상온에서의 유효 자화(4 .pi. $M_{eff}$)값은 10385 emu/$cm^{3}$,10770 emu/$cm^{3}$였다. 자기 이방성을 조사하기 위해 VSM(vibrating sample magnetometer)을 이용하여 측정된 포화자화(4 .pi. $M_{s}$ )값은 16409 emu/$cm^{3}$와 14222 emu/$cm^{3}$였다. 유효 이방성 자기장 $H_{A}$ (effective anisotropy field)과 일축 이방성상수 $K_{u}$ (uniaxial anisotropy constant)는 각각 6024 Oe, 3452 Oe와 3.93 * $10^{6}$ erg/$cm^{3}$, 1.95 * $10^{6}$erg/$cm^{3}$였다. 77K에서 상온까지 온도에 따른 유효 포화 자화(4 .pi. $M_{eff}$)값을 측정하였으며, 포화자화의 온도의존성은 Bloch 법칙을 잘 만족시켰다. 이 포화자화곡선을 최적화하여 Bloch 상수 B, C를 구하였고, 77K에서 0K까지 외삽법으로 구한 $M_{eff}$(0)는 각각 894 erg/$cm^{3}$, 891 erg/$cm^{3}$였으며, 스핀파 경도 상수 D값과 교환 경도 상수 $A_{eff}$는 각각 148 meV .angs. $^{2}$, 103.8 meV .angs. $^{2}$와 1.77 * $10^{-6}$ erg/cm, 0.67 * $10^{-6}$ erg/cm 였다.다.

  • PDF

전방향성 E & H면 슬릿 Folded형 마이크로스트립 패치 안테나 (Slit Folded Type Microstrip Antenna for Omnidirectional E-plane and H-plane)

  • 김종래;우종명;오승엽
    • 한국전자파학회논문지
    • /
    • 제13권9호
    • /
    • pp.956-963
    • /
    • 2002
  • 본 논문에서는 SIR(Stepped Impedance Resonator) 구조를 이용한 compact한 slit-folded형 마이크로스트립패치 안테나를 제작하였다 기존의 길이 방향의 $\lambda_{g}/2$ 공진을 이용한 평면형 마이크로스트립패치 안테나를 길이방향 중심에서 반으로 접어서 마이크로스트립 급전선으로 급전하여 전방향성 방사패턴을 얻은 Folded형 마이크로스트립 안테나를 적층형으로 제작시 급전선의 영향을 줄이기 위하여 급전방법을 상하면 패치사이의 접지면 위에 설계하여 급전핀을 세웠다. 또한 평면형 H형 SIR 구조를 Folded형 안테나에 적용한 슬릿 folded형 안테나는 기존의 folded형 안테나에 비하여 27.5 % 더 소형화하였다. 기존의 folded형 마이크로스트립 안테나는 E면(zx-plane)과 H면(xy-plane)의 평균이득이 거의 1.8 dB 정도의 차이를 보였으나 본 논문에서 제안한 슬릿 folded형은 E & H-plane의 평균이득차이가 0.1 dB로 거의 같음을 알 수 있다.

Analytical Modeling of Conventional and Miniaturization Three-Section Branch-Line Couplers

  • You, Kok Yeow;AL-AREQI, Nadera;Chong, Jaw Chung;Lee, Kim Yee;Cheng, Ee Meng;Lee, Yeng Seng
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.858-867
    • /
    • 2018
  • Analytical modeling equations are proposed for the conventional and modified three-section branch-line couplers. The analytical equations are explicit and capable of determining the characteristic impedance of each branch line for the coupler at desired coupling level as well as the suitability of broadband S-parameters analysis. In addition, a bandwidth extension and miniaturization of three-section branch-line coupler using slow-wave and meandering line structures were designed. The modified coupler, which is able to operate within frequencies from 1.5 to 3.32 GHz has been fabricated, tested and compared. A bandwidth extension of 600 MHz and 53% reduced size of the modified coupler have been achieved compared to a conventional coupler. The modified coupler has roughly insertion loss and coupling of -4 dB and -3.2 dB, while the isolation and return loss, respectively less than -14 dB with fractional bandwidth of 77 %, as well as phase imbalances less than $2^{\circ}$ over the operating bandwidth. Overall, the derived analytical model, simulation and measurement results demonstrated a good agreement.

3축 가속도 센서 기반의 무선 진동 측정 시스템 (Wireless Vibration Measurement System Using a 3-Axial Accelerometer Sensor)

  • 유주연;박근철;전아영;김철한;김윤진;노정훈;전계록
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.131-136
    • /
    • 2011
  • In this study, a compact wireless vibration measurement system was developed using a 3-axial accelerometer in order to evaluate the vibration stimulation system. A low power microprocessor chip integrated with 2.4 GHz RF transceiver was used for the wireless data communication. To evaluate the system, the frequencies and accelerations from the vibration stimulation system were measured using an LVDT sensor and a vibration measurement system. The average frequency difference by the measurement system was less than 0.1 Hz, and the standard deviation of frequencies estimated by the LVDT sensor and the accelerometer was below 0.08 Hz. The developed system was applied to access a vibration stimulation system for the future study. The average acceleration difference of the central and peripheral point of the stimulation system was less than 0.0005 g(1 g=9.8 $m/s^2$), and the standard deviation of the acceleration was below 0.004 g, which shows the usefulness of the wireless vibration measurement system.