• Title/Summary/Keyword: 2.4-DNPH

Search Result 40, Processing Time 0.022 seconds

Preparation of Hydrazine Impregnated Adsorbents and Selective Adsorption Properties for Carbonyl Compounds in Cigarette Mainstream Smoke (Hydrazine 첨착 흡착제의 제조 및 담배 주류연 중 카보닐 화합물의 선택 흡착 특성)

  • Lee, John-Tae;Park, Jin-Won;Lee, Jeong-Min;Rhee, Moon-Soo;Hwang, Keon-Joong;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.210-216
    • /
    • 2006
  • To use the filter materials for selective removal of carbonyl compounds in cigarette mainstream smoke, hydrazine such as 2,4-dinitrophenylhydrazine (2,4-DNPH) and dansylhydrazine (DAH) impregnated adsorbents were prepared with perchloric acid or phosphoric acid as an accelerator in hydrazone formation reaction. Changes of molecular structure and morphology of adsorbents in various of impregnator were investigated by FTIR/ATR and SEM. Impregnation amount caused by reaction time, acid type and impregnation reagent, and the adsorption properties of carbonyl compounds in cigarette mainstream smoke were studied. Amounts of impregnation increased with increasing reaction time. The removal amount for vapor phase carbonyl compounds by 2,4-DNPH impregnated adsorbent was higher than that of dansylhydrazine impregnated adsorbent. The selectivity of 2,4-DNPH impregnated polyacrylic type adsorbent was superior to those of other adsorbents. This result indicates that the 2,4-DNPH impregnated polyacrylic adsorbent is applicable to cigarette filter material because of its fast reactivity and porosity.

Measurement of Carbonyl Compounds in Ambient Air using a DNPH Cartridge coupled with HPLC Method (DNPH 카트리지와 HPLC를 이용한 대기 중 카르보닐화합물의 농도측정)

  • 황윤정;박상곤;백성옥
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.199-209
    • /
    • 1996
  • The purpose of this study is to evaluate analytical method for the measurement of carbonyl compounds and to apply method to the measurement of indoor and outdoor concentrations of these compounds at public facilities. For sampling, 2.4-dinitrophenylhydrazine (DNPH) coated DNPH-Silica cartridges were uwed in this study. DNPH reacts with carbonyl compounds and forms carbonyl hydrazone, The carbonyl hydarzone was eluted from the cartridge with acetonitrile and analyzed by reverse-phase HPLC with UV detection. Possible interference caused by ozone during sampling was eliminated by using KI trap commected in series with the DNPH-Silica cartridge. A number of experimental studies were undertaken to evaluate and validate the analytical method, including collection efficiency, recovery, repeatability, lower limits of detection, and effect of ozone. Indoor and outdoor measurements of carbonyl compounds were simultaneously carried out at 14 public facilities located in Taegu city and Kyungsan city from June to July, 1995. Except for one or two sites, the indoor concentrations were found to be higher than the outdoor concentrations for carbonyl compounds. And the concentrations of carbonyl compounds measured in the morning and afternoon were showed higher than the concentrations measured in the evening.

  • PDF

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

Comparison of Chromotropic Acid Method and DNPH-HPLC Method for the Measurement of Formaldehyde in the Air (공기 중 포름알데히드 측정을 위한 크로모트로핀산법과 DNPH/HPLC방법의 비교.평가)

  • Hwang, Yun-Jeong;Park, Sang-Gon;Baek, Seong-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.5
    • /
    • pp.519-524
    • /
    • 1998
  • Formaldehyde is known to have adverse health effects, and is also found to be a product of atmospheric. photochemical reaction%. Several methods have been employed for the measurement of formaldehyde. Among them, two common methods are comparatively evaluated in this study, i.e. the chromotropic acid method and the HPLC method coupled with 2,4- dinitrophenylhydrazine (DNPH) derivatization of carbonyl compounds. Method evaluation and validation were performed with respect to repeatability, linearity, collection efficiency, and recovery efficiency. Comparison of formaldehyde concentrations measured simultaneously in the field using the two (n=20) and 35.8%, respectively. Overall, the measured levels by chromotropic acid method appeared to ice significantly higher than those by DNPH-HPLC method, indicating a positive interference due to the other aldehydes collected together with formaldehyde.

  • PDF

Method comparison for analyzing formaldehyde in marker pen ink (마킹펜 잉크 내 폼알데하이드 분석법 비교)

  • Park, Kwang Seo;Kim, Yong Shin;Choe, Eun Kyung
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.115-124
    • /
    • 2020
  • Marker pens belong to school things that are controlled by the regulation system called safety confirmation under special act on the safety of products for children with the formaldehyde criteria of 20 mg/kg. With nine marker pens available commercially, formaldehyde in marker pen ink was analyzed by present test standard where marking on a fabric swatch with a pen and extracting the swatch in water and derivatization with Nash reagent followed by UV/Vis spectrophotometeric measurement (Nash-UV/Vis method), giving not detected results or a false positive result in case of a colored water extract. However, the contents of formaldehyde in ink of nine marker pens were determinded to range between 3.2 ~ 93.2 mg/kg with three results above the safety criteria of 20 mg/kg by HPLC/DAD measurements on DNPH derivatives of formaldehyde (DNPH-HPLC/DAD method) in ink dissolved directly in water using an ultrasonic bath. Therefore, the DNPH-HPLC/DAD method with the extraction of ultrasonic dissolving ink in water is proposed as a proper method for analyzing formaldehyde in ink. The proposed method has advantages of lower detection limit and accuracy with colored extracts as well as a simple and fast extraction. The accuracy and precision of this method was estimated to be 90.1 ~ 105.4 % and 0.6 ~ 3.3 %, respectively by spiking tests in the ranges of 20 mg/kg and 40 mg/kg using matrixes such as highlighter pen ink, board marker ink, chalk marker pen ink and painter marker ink.

A novel nanocomposite as adsorbent for formaldehyde removal from aqueous solution

  • Hejri, Zahra;Hejri, Mehri;Omidvar, Maryam;Morshedi, Sadjad
    • Advances in nano research
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 2020
  • In order to develop a new adsorbent for removal of formaldehyde from aqueous solution, surface modification of TiO2 nanoparticles was performed with 2,4-Dinitrophenylhydrazine (DNPH) that have a strong affinity to the formaldehyde. Sodium dodecyl sulfate (SDS) surfactant was used to improve the DNPH grafting to TiO2 surface. Modified adsorbents were characterized by SEM, TEM, XRD, EDX and FTIR. Since the COD level in wastewaters including formaldehyde is considerable, it is necessary to determine the COD content of the synthetic wastewater. In order to determine the optimal removal conditions, the effect of contact time (60-210 min), pH (4-10) and adsorbent dosage (0.5-1.5 g/L) on adsorption and COD removal efficiencies were studied, using response surface method. EDX and FTIR analysis confirmed the presence of nitrogen-containing functional groups on the modified TiO2 surface. The maximum formaldehyde adsorption and COD removal efficiencies by modified TiO2 were about 15.65 and 7.35% higher than the unmodified nanoparticles respectively. Therefore, the grafting of nano-TiO2 with DNPH would greatly improve its formaldehyde adsorption efficiency. The optimum conditions determined for a maximum formaldehyde removal of 99.904% and a COD reduction of 94.815% by TiO2/SDS/DNPH nanocomposites were: adsorbent dosage 1.100 g/L, pH 7.424 and the contact time 183.290 min.

Selective Adsorption Properties of Carbonyl Compounds in Cigarette Mainstream Smoke by Hydrazine Impregnated Adsorbent (Hydrazine 첨착 흡착제에 의한 담배 주류연 중 카보닐 화합물의 선택 흡착 특성)

  • Park Jin-Won;Rhee Moon-Soo;Lee John-Tae;Hwang Keon-Joong;Hwang Taek-Sung
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.27 no.2
    • /
    • pp.178-188
    • /
    • 2005
  • To use the filter materials for selective removal of carbonyl compounds in cigarette mainstream smoke, hydrazine such as 2,4-dinitrophenylhydrazine and dansylhydraznie impregnated adsorbents were prepared with perchloric acid or phosphoric acid as a accelerator in hydrazone formation reaction. The change of morphology of adsorbents in various of impregnator were investigated by SEM. Impregnation amount caused by reaction time, acid type and impregnation reagent, and the adsorption properties of carbonyl compounds in cigarette mainstream smoke were investigated. Amounts of impregnation was increased as increasing reaction time. The removal amount for vapor phase carbonyl compounds by 2,4-DNPH impregnated adsorbent was higher than that of dansylhydrazine impregnated adsorbent. The selectivity of 2,4-DNPH impregnated polyacrylic type adsorbent was superior to those of other adsorbents. This results indicated that the 2,4-DNPH impregnated polyacrylic adsorbent was applicable to cigarette filter material because of its fast reactivity and porosity.

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Some considerations for the determination of carbonyl compounds in air: Reaction characteristics of formaldehyde with 2.4-DNPH (대기 중 카보닐 계열 성분의 분석기법의 연구: 포름알데하이드와 DNPH의 반응 특성을 중심으로)

  • Hong, Y.J.;Kim, K.H.
    • Analytical Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • A number of carbonyl compounds including formaldehyde and acetaldehyde are well known for their toxicity and irritancy. Hence, acquisition of both qualitative and quantitative tool for their analysis is essential to resolve issues associated with malodor or indoor pollution. Using HPLC/UV method, we examined various aspects involved in the measurements of formaldehyde in environmental samples. The results of our analysis indicated that its detection was made as low as 0.5 ppb (assuming 5 L of sample volume), while its precision was maintained near 2% in terms of relative standard error (RSE). When the stability of calibration was checked by variability of slope values obtained over long-term period (e.g., one month), its values were found to remain constantly with RSE values of 3%. It was also found that liquid-phase reaction between formaldehyde and DNPH proceed very slowly to attain equilibrium (one and half hour), while requiring adequate amount of DNPH to form their derivatives. The overall results of our study thus suggest that there are a number of factors to consider for the accurate analysis of formaldehyde in ambient air.