• 제목/요약/키워드: 2-phase calibration

검색결과 357건 처리시간 0.025초

카운터 기반 디지털 보상 기법을 이용한 위상 고정 루프 (Phase-Locked Loops using Digital Calibration Technique with counter)

  • 정찬희;;이관주;김훈기;김수원
    • 전기학회논문지
    • /
    • 제60권2호
    • /
    • pp.320-324
    • /
    • 2011
  • A digital technique is adopted to calibrate the current mismatch of the charge pump (CP) in phase-locked loops. A 2 GHz charge pump PLL (CPPLL) is used to justify the proposed calibration technique. The proposed digital calibration technique is implemented simply using a counter. The proposed calibration technique reduces the calibration time by up to a maximum of 50% compared other with techniques. Also by using a dual-mode CP, good current matching characteristics can be achieved to compensate $0.5{\mu}A$ current mismatch in CP. It was designed in a standard $0.13{\mu}m$ CMOS technology. The maximum calibration time is $33.6{\mu}s$ and the average power is 18.38mW with 1.5V power supply and effective area is $0.1804mm^2$.

A Study for the Unit Nonresponse Calibration using Two-Phase Sampling Method

  • Yum, Joon Keun;Jung, Young Mee
    • Communications for Statistical Applications and Methods
    • /
    • 제9권2호
    • /
    • pp.479-489
    • /
    • 2002
  • The case which applies two-phase sampling to stratification and nonresponse problem, it is a poweful and effective technique. In this paper we study the calibration estimator and its variance estimator for the population total using two-phase sampling method according to the of auxiliary information for population and sample having strong correlation with an interested variable in unit nonresponse situation. The auxiliary information that available both at first-phase and second-phase sampling can be used to improve weights by the calibration procedure. A weight which corresponds to the product of sampling weights and response probability is calculated at each phase of sampling.

Zadoff-Chu sequence를 이용한 실시간 Calibration 알고리즘과 FPGA 구현 (A Novel Calibration Method Using Zadoff-Chu Sequence and Its FPGA Implementation)

  • 장재현;손철봉;양현욱;최승원
    • 디지털산업정보학회논문지
    • /
    • 제9권3호
    • /
    • pp.59-65
    • /
    • 2013
  • This paper presents a novel calibration method for a base station system adopting an antenna array. The proposed technique utilizes Zadoff-Chu sequence, which is included in the LTE pilot signal periodically, in order to compute the phase characteristic of each antenna channel. As the Zadoff-Chu sequence exhibits an excellent autocorrelation characteristic, it is possible for the receiving base station to retrieve the Zadoff-Chu sequence transmitted from each mobile terminal. In addition, we can obtain the phase characteristic of each antenna channel, which is the ultimate goal of the calibration procedure. The proposed calibration algorithm has been implemented using an FPGA (Field Programmable Gate Array). We have applied the proposed algorithm to an array consisting of 2 antenna elements for simplicity. the phase value implied to the first and second antenna path is very accurately calculated from the proposed procedure. From the experimental test, the proposed method provides accurate calibration results.

Adaptive Calibration Method in Multiport Amplifier for K-Band Payload Applications

  • Moon, Seong-Mo;Shin, Dong-Hwan;Lee, Hong-Yul;Uhm, Man-Seok;Yom, In-Bok;Lee, Moon-Que
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.718-721
    • /
    • 2013
  • This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port-to-port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed $2{\times}2$ and $4{\times}4$ MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.

Gain and Phase Mismatch Calibration Technique in Image-Reject RF Receiver

  • Lee, Mi-Young;Yoo, Chang-Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제10권1호
    • /
    • pp.25-27
    • /
    • 2010
  • This paper presents a gain and phase mismatch calibration technique for an image-reject RF receiver. The gain mismatch is calibrated by directly measuring the output signal amplitudes of two signal paths. The phase mismatch is calibrated by measuring the output amplitude of the final IF output at the image band. The calibration of the gain and phase mismatch is performed at power-up, and the normal operation of the RF receiver does not interfere with the mismatch calibration circuit. To verify the proposed technique, a 2.4-GHz Weaver image-reject receiver with the gain and phase mismatch calibration circuit is implemented in a 0.18-${\mu}m$ CMOS technology. The overall receiver achieves a voltage gain of 45 dB and a noise figure of 4.8 dB. The image rejection ratio(IRR) is improved from 31 dB to 59.76 dB even with 1 dB and $5^{\circ}$ mismatch in gain and phase, respectively.

Pseudolite Antenna Calibration Algorithm using a Multi-Antenna Receiver

  • Kim, Chong-Won;Jeon, Sang-Hoon;Kim, Ghang-Ho;Kee, Chang-Don;Lee, Taik-Jin;So, Hyoung-Min
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권2호
    • /
    • pp.250-259
    • /
    • 2012
  • The need for position information in indoor environments has been growing lately. Several indoor navigation systems have been studied. Among them, pseudolite-based indoor positioning systems are one of the best systems to obtain precise position measurements. However, the installation of such systems is very difficult because the calibration of pseudolite antenna position is complicated. For precise calibration, the use of carrier phase measurements is necessary, and whenever carrier phase measurements are considered, problems with cycle ambiguity appear. In this paper, a new approach to calibrate the positions of pseudolite antennas is proposed. By using a multi-antenna, the ambiguity can be eliminated, epoch by epoch, for every single carrier phase measurement. Moreover, the number of calibration points can be reduced down to 3 by use of measurements collected at unknown positions. Using the proposed methods, the process of the collection of carrier phase measurements becomes considerably simple and convenient. Simulation results are presented to verify the proposed algorithms.

THE CALIBRATION ESTIMATION USING TWO-STEP NEWTON'S ALGORITHM IN TWO-PHASE SAMPLING

  • Son, Chang-Kyoon;Yum, Joon-Keun
    • Journal of applied mathematics & informatics
    • /
    • 제7권1호
    • /
    • pp.237-245
    • /
    • 2000
  • In this paper, we consider to the adjustment weighting procedure in the two phase sampling scheme. In general, the unit nonresponses may be occured in the final survey operation. When the unit nonresponse be generated in survey, it is able to use the auxiliary variable for estimating of interest variable. In this viewpoint, we use the two kinds level of auxiliary variable, $X_{1k}$ and $X_{2k}$ for the calibration procedure. We proprose the two-step Newton's method in the calibration estimation procedure for the two phase sampling.

Calibration of frequency propagation channel sounder based on five-port reflectometer

  • Yem Van;Braga Judson;Huyart B;Begaud X;de Sousa F.R;Huyen Nguyen Bich
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 ICEIC The International Conference on Electronics Informations and Communications
    • /
    • pp.23-26
    • /
    • 2004
  • Five-port reflectometer which consists of a ring with 5 arms (two inputs, three outputs) and three RF power detectors has been used as a vector network analyser, a demodulator in the homodyne receiver as well as in Phase Looked Loop (PLL) and so on. Calibration of five-port reflectometer is an important task. In this paper, we present a calibration method of five-port for a propagation channel sounder. The method is based on measurement of the phase differences between the three voltages at the five-port's outputs in order to determine the ratio of two input incident waves. The frequency channel sounder based on five-port is calibrated for each frequency from 2.2 GHz to 2.6 GHz with 1 MHz step. This method can also determine the absolute delays of each propagation path in the propagation channel. The calibration method is validated using measurement data.

  • PDF

대기 중 Carbonyl 성분들의 검량 분석 기술에 대한 연구: 액상 대비 기체상 표준시료의 오차발생 특성 연구 (A Study of Calibration Bias in the Analysis of Airborne Carbonyl Compounds between Gaseous and Liquid-phase Standards by High Performance Liquid Chromatography (HPLC))

  • 이민희;김기현
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, the effect of standard phase difference in calibration of carbonyl compounds (CC) was evaluated by using their standards prepared in both gaseous and liquid phase. For this analysis, standards in both phases were prepared for 6 different CCs (formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA) and valeraldehyde (VA)) at similar concentration levels. Their gaseous standard was calibrated after derivatization with three types of DNPH cartridge, and their calibration results were compared against liquid-phase standards. Although there was a strong compatibility between 2 phases for CCs with lower molecular weights (e.g., formaldehyde and acetaldehyde), it was not the case for the heavier CCs. The results of our analysis indicate that the analytical bias of the heavier CCs can be significantly large (by more than a few tens of %). As a result, underestimation of hevier CCs can be significant, if their gaseous samples are quantified by liquid phase standard.

Ellipsometry에서의 Calibration 및 입사면 고정형 Ellipsometer (Calibration and a Plane of Incidence Fixed Ellipsometer)

  • 경재선;오혜근;안일신;김옥경
    • 반도체디스플레이기술학회지
    • /
    • 제2권4호
    • /
    • pp.23-26
    • /
    • 2003
  • The general users find difficulties in using ellipsometers. Thus, the object of this study is to construct an ellipsometer with simple operation principle. We developed an ellipsometer which does not require alignment and calibration before measuring sample. A basis structure model after rotating a compensator spectroscopic ellipsometry, the fixed incidence angle at $70^{\circ}$. This ellipsometer does not demand calibration, because the plane of incidence is not changed due to the novel sample holder structure. The results for various standard samples were compared with those from conventional RCSE to test the performance of this instrument. Also repeated measurements were performed to test the precision of the calibration coefficient in a plane of incidence fixed.

  • PDF