• 제목/요약/키워드: 2-dimensional measurement

검색결과 921건 처리시간 0.029초

장갑의 적합성 향상을 위한 손부위 2차원 계측정보 DB구축에 관한 연구 -성인 남.녀 만 18세에서 만 64세를 중심으로- (The Database Development of 2-D Hands Measurement for Improving Fitness of gloves -focused on the ages from 18 to 64 of male & female adults-)

  • 최혜선;김은경
    • 한국의류학회지
    • /
    • 제28권3_4호
    • /
    • pp.509-520
    • /
    • 2004
  • The aim of this study was to provide the basic 2-dimensional statistics requisite in the siting system and design of gloves. The 64 static measurements were selected to provide information about hands. Participants in the study were 824 adults, aged between 18 and 64. Subjects were divided into four age groups: 18 to 29, 30 to 39, 40 to 49, and 50 to 64, and separated according to sex. Statistical tests such as Descriptive Analysis, and Anova were conducted to analyze the data and ascertain the differences among the ages. The disparities between sex groups were compared by T-test. In addition, correlation among the 57 measurements was analyzed and the results were compared to the data from Japanese and other studies. The results indicated that all the measurements were significantly larger in the male group. There were significant differences among age groups for most hand circumferences, breadths and thickness items. As the age increased, the hand circumferences, breadths and thickness items became wider and thicker. In addition, as the age increased, the mean measurement value of the length items decreased, so that it became shorter. Hand length was highly correlated with finger length, palm length and height. Maximum hand circumference II was highly correlated with hand circumferences, hand breadth and weight.

플라즈마 디스플레이 패널에서 방출되는 광의 3차원 측정을 위한 Scanned Point-Detecting System (The scanned point-detecting system for three-dimensional measurement of light emitted from plasplay panel)

  • 최훈영;이석현;이승걸
    • 한국광학회지
    • /
    • 제12권2호
    • /
    • pp.103-108
    • /
    • 2001
  • 플라즈마 디스플레이 패널(plasma display panel :PDP)에서 방출되는 광의 3차원 분포를 측정하기 위한 scanned point-detecting system(SPDS)을 고안하여 제작하였으며 이 시스템을 이용하여 실제 PDP의 3차원 광 방출 특성을 측정하고 해석하였다. SPDS는 상면에 핀홀이 달려 있는 광검출기(point detector)를 위치시킴으로써 특정 지점으로부터 방출되는 광만을 검출할수 있다. 3차원 물체의 특정 지점으로부터 방출된 광은 핀홀을 지나 검출기로 모두 입사되지만 다른 지점으로부터 방출된 광은 핀홀 앞에서 미리 집속되거나 핀홀 뒤에서 집속될것이므로 이러한 광들은 핀홀에 의해 대부분 차단될 것이다. 그러므로 물체의 특정 지점으로부터 방출된 광만이 핀홀이 설치된 검출기에 의해 검출되어 진다. SPDS를 이용하여 PDP cell 내에서 측정된 3차원 광 intensity 분포로부터 cellso의 방전현상을 다음과 같이 유추해낼수 있었다. Z축 측정이 진행될수록광의 intensity는 증가하였고 ITO전극의 안쪽부분에서 검출되는 광의 intensity가 가장 컸고 Y축 scan시 나타나는 X-Z평면에서 광의 intensity가 격벽과 격벽의 중심부분에서 가장 크게 나타났다.

  • PDF

Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

  • Tasanapanont, Jintana;Apisariyakul, Janya;Wattanachai, Tanapan;Sriwilas, Patiyut;Midtbo, Marit;Jotikasthira, Dhirawat
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.117-122
    • /
    • 2017
  • Purpose: The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. Materials and Methods: Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient(ICC) was used to assess intraobserver reliability. Results: The root surface area measurements ($230.11{\pm}41.97mm^2$) obtained using CBCT were slightly greater than those ($229.31{\pm}42.46mm^2$) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. Conclusion: This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

2차원 데이터를 활용한 3차원 충돌 변형 측정 방법 (Three-dimensional Crush Measurement Methodologies Using Two-dimensional Data)

  • 한인환;강희진;박종찬;하용민
    • 한국자동차공학회논문집
    • /
    • 제23권3호
    • /
    • pp.254-262
    • /
    • 2015
  • This paper presents 3D collision deformation modelling methodologies using photogrammetry for reconstruction of vehicle accidents. A vehicle's deformation shape in collision provides important information on how the vehicle collided. So effective measurement(scanning) and construction of a corresponding appropriate model are essential in the analysis of collision deformation shape for obtaining much information related to collision accident. Two measurement methods were used in this study: Indirect-photogrammetry which requires relatively small amount of photos or videos, and direct-photogrammetry which requires large amount of photos directly taken for the purpose of 3D modelling. When the indirect-photogrammetry method, which was mainly used in this study, lacked enough photographic information, already secured 2D numerical deformation data was used as a compensation. This made 3D collision deformation modelling for accident reconstruction analysis possible.

Automatic Hand Measurement System from 2D Hand Image for Customized Glove Production

  • Han, Hyun Sook;Park, Chang Kyu
    • 한국의류산업학회지
    • /
    • 제18권4호
    • /
    • pp.468-476
    • /
    • 2016
  • Recent advancements in optics technology enable us to realize fast scans of hands using two-dimensional (2D) image scanners. In this paper, we propose an automatic hand measurement system using 2D image scanners for customized glove production. To develop the automatic hand measurement system, firstly hand scanning devices has been constructed. The devices are designed to block external lights and have user interface to guide hand posture during scanning. After hands are scanned, hand contour is extracted using binary image processing, noise elimination and outline tracing. And then, 19 hand landmarks are automatically detected using an automatic hand landmark detection algorithm based on geometric feature analysis. Then, automatic hand measurement program is executed based on the automatically extracted landmarks and measurement algorithms. The automatic hand measurement algorithms have been developed for 18 hand measurements required for custom-made glove pattern making. The program has been coded using the C++ programming language. We have implemented experiments to demonstrate the validity of the system using 11 subjects (8 males, 3 females) by comparing automatic 2D scan measurements with manual measurements. The result shows that the automatic 2D scan measurements are acceptable in the customized glove making industry. Our evaluation results confirm its effectiveness and robustness.

2차원 CCD를 이용한 복사기 렌즈의 실시간 MTF 측정 (Real time MTF Measurement of Copy Lenses by two-dimensional CCDs)

  • 조현모;이윤우;이인원;김태희;최옥식;이환규
    • 한국광학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 1996
  • 렌즈의 실시간 성능축정을 위하여 MTF측정장치에 CCD를 많이 사용하고 있다. 본 연구에서는 2차원 CCD를 복사기 렌즈의 실시간 MFT측정장치에 사용했을 때 CCD에 의한 각종 MTF특성을 분석하였다. CCD로 측정한 복사기 렌즈의 MTF는 2차원 CCD의 shift register가 배열된 방향과 셔터 속도, 광신호 증폭회로의 증폭률에 따라 다른 특성을 나타내었다. 광원의 밝기에 의한 MTF 값의 변화를 줄이기 위하여 축상면 및 비축상면에서 복사조도가 균일한 광원장치를 제작하였으며 MTF 값이 측정된 표준렌즈를 사용하여 복사기 렌즈용 실시간 MTF측정장치를 교정하였다.

  • PDF

3차원 체형 측정기를 통한 경.견부 통증요인 분석 (The Study of Pain-Increased Factors on Cervical and Shoulder Pain by 3 Dimensional Moire Scanner)

  • 양회송;허자은;김보영;서동용;안창헌;양훈경;정찬주;이형수
    • 대한물리치료과학회지
    • /
    • 제12권3호
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to find out factors(shoulder level, acromion-occipital length, spine alignment, spine-scapula inferior angle length) of pain of neck & shoulder by 3 Dimensional Moire Scanner. 50 female student s aged 20 to 25 years old participated who lived in Sun-cheon si Jeonnam. They were examined with three measurement methods(Visual Analogue Scale : VAS, Algometer, 3 Dimensional Moire Scanner(IBS-2000). According to the results of multiple regression analysis. 1) There was a significant difference with shoulder level and spine-scapula inferior angle based on VAS. 2) There was a significant difference with shoulder level based of Algometer measurement value in Rhomboid muscles.

  • PDF

A Study on 3-Dimensional Profilometry of Steam Generator Tube Using a New Eddy Current Probe

  • Kim, Young-Kyu;Song, Myung-Ho;Choi, Myung-Sik
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.225-235
    • /
    • 2010
  • There are many types of the geometric transitions such as dent, bulge, protrusion, expansion, etc, on the inner and outer surfaces of heat exchanger tubes, steam generator tubes, and condenser tubes of nuclear power plants. Such geometric transition causes a local residual stress in heat exchanger tubes and acts as a structural factor accelerating the evolution of defects, in particular stress corrosion cracks. In the conventional eddy current test methods, the bobbin coil profilometry can provide 2-dimensional geometric information on the variation of the average inner diameter along the tube length, but the 3-dimensional distribution and the quantitative size of a local geometric transition existing in the tube cannot be measured. In this paper, a new eddy current probe, developed for the 3-dimensional profile measurement, is introduced and its superior performance is compared with that from the conventional bobbin coil profilometry for the various types of geometric transition. Also, the accuracy of the probe for the quantitative profile measurement is verified by comparing the results with that from the laser profilometry. It is expected that the new eddy current probe and techniques can be effectively used for an optimization of the tube expansion process, and the management of tubes with geometric transitions in service.

두개의 엔코드 초음파 센서를 이용한 측정면의 두께 측정 및 위치 측정 (Measurement of Thickness and Position of the Surface using the Two Encoder Ultrasonic Sensors)

  • 강명철;장유신;김형국;배종일;이만형
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.510-514
    • /
    • 2002
  • The 3-dimensional measuring machine by using an ultrasonic sensor is used one of the NDE(Non Destructive Examination). It is applied to the inspection of pipelines, boreholes, pressure vessel and tank, and so on. In particular when a harsh environment prohibits the use of moving mechanical parts. The 3-dimensional measuring machine by using an ultrasonic sensor, which measure 1-dimensional information and 2-dimensional information simultaneously from a target of inspection, and then reembody 3-dimensional information. So we can find the situation in progress and predict remaining life and corrosion without destructive examination. It's a point of excellence that the 3-dimensional measuring machine is portable.

  • PDF