• Title/Summary/Keyword: 2-HEMA

Search Result 179, Processing Time 0.027 seconds

Preparation and Properties Measurement of 2-hydroxyethyl methacrylate / Water-dispersed polyurethane composites

  • Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1224-1229
    • /
    • 2018
  • In this study, 2-hedroxyethyl methacrylate (2-HEMA) was graft synthesized on water-dispersed polyurethane using polytetramethylene ether glycoll (PTMG), and then the film of resin was prepared and the physical properties of polyurethane resin were measured. The mechanical properties of the synthesized polyurethane resin were measured by using FT-IR, UTM, adhesion performance measuring instrument. As a result of tensile strength measurement, the tensile strength of HPUD4 with high 2-HEMA content was increased to $5.05kgf/mm^2$, the elongation was measured as 285% of the HPUD1 sample not containing 2-HEMA and adhesive strength of HPUD4 sample was measured at 9.1 sec to 635 psi.

Study on the Polymerization of Hydrogel Polymer Containing HEMA and Measurement Method of Oxygen Transmissibility (HEMA를 포함한 친수성 폴리머 중합 및 산소 투과율 측정 방법에 관한 연구)

  • Kim , Tae-Hun;Sung, A-Young
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.749-754
    • /
    • 2009
  • HEMA (2-hydroxyethyl methacrylate) is a hydrophilic material which is broadly used for ophthalmologic purposes and especially in the manufacture of soft contact lenses. Also, the oxygen transmissibility (Dk/t) is a very important physical characteristic in the evaluation of a material’s adequacy to be used to produce contact lenses. This study used HEMA (2-hydroxyethyl methacrylate), MMA (methylmethacrylate), NVP (Nvinyl-pyrrolidone), the cross-linker EGDMA (ethylene glycol dimethacrylate) for copolymerization, and measured the oxygen transmissibility of the central and peripheral areas of the manufactured general and color contact lenses using the polarographic method. The measurement showed that the decreased amount of oxygen transmissibility of the central and peripheral areas of the contact lenses measured using the polarographic method range between 40.77% and 49.13%, and the oxygen transmissibility of the color contact lens showed a larger decrease due to the effects of the coloring materials.

Polymerization of HEMA by Electron beam Irradiation and Fabrication of Soft contact lens (전자빔조사에 의한 HEMA의 중합과 소프트콘택트렌즈 제조)

  • Hwang, Kwang-Ha;Shin, Joong-Hyeok;Sung, Yu-Jin;Jeong, Keun-Seung;Jun, Jin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.2
    • /
    • pp.135-141
    • /
    • 2012
  • Purpose: Polymerization of HEMA(2-hydroxyethyl methacrylate) which can be used in the soft contact lens has been performed by using electron beam(EB) irradiation, and examined the best condition for the polymerization. Comparing the physical properties of the contact lenses to the one fabricated by thermal polymerization method, we check the use possibility of the EB irradiation to the fabrication of the soft contact lens. Methods: We investigated the degree of polymerization of the HEMA according to the composition of the monomer, the additive ratio and the dose of electron beam (0~120 kGy). The degree of polymerization was measured depending on the EB dose to research the best synthetic condition under the EB irradiation. The physical properties of the contact lens such as water content(%), oxygen transmissibility(Dk/t) and optical transmittance were analysed by using the FT-IR results with comparing the two different polymerization method (thermal and electron beam polymerization) with same additive ratio. Results: When the dose of electron beam was above 100 kGy, the degree of polymerization of HEMA was above 99% with regardless using cross-linker and initiator. The water content of the lens fabricated by EB method showed 10% higher than the one by the thermal method which was 40%. The lens fabricated by EB method also showed higher oxygen transmissibility(Dk/t) as same with the water content, and showed twice higher value in the lens fabricated by pure HEMA. According to the FT-IR results, hydrophilic property of the lens fabricated by EB method was increased due to increasing the intermolecular hydrogen bonding. It showed above 90% optical transmittance in the visible range of wavelength on the contact lenses fabricated by the both of two different polymerization method. Conclusions: The polymerization of HEMA without cross-linker and initiator was successful above 100 kGy of EB irradiation. Moreover the lens fabricated from the polymer synthesized by pure HEMA with 100 kGy of EB showed the highest water content and oxygen transmissibility. Therefore EB irradiation is another possible method to synthesize the polymer which can be used for the soft contact lens.

Study on Characterization of Contact Lens with Hydrophobic Monomers (소수성 모노머들을 포함한 콘택트렌즈의 특성에 관한 연구)

  • Ye, Ki-Hun;Kim, Tae-Hun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • Purpose: In this study, we compared the physical properties of the compositions that were mixed with basic materials of HEMA (2-Hydroxyethyl methacrylate)/Silicone and BMA (Butyl methacrylate), MMA (Methyl methacrylate) by making the silicone contact lens. Method: Each sample of contact lenses was fabricated by cast mould method. We analyzed results by using average values of physical property of each sample. Results: In the composition of HEMA/Silicone/BMA, water contents of samples showed the value from 24.69% to 29.26%. Ultimate strength of samples showed the value from 0.109 kgf to 0.263 kgf. In the composition of HEMA/Silicone/MMA, swelling ratio of samples showed the value from 13.56% to 14.83%. Water contents of samples showed the value from 25.61% to 29.33%. Ultimate strength of samples showed the value from 0.107 kgf to 0.286 kgf. Conclusions: The compositions of percents of silicone were ranged from 0.20% to 11.50% and the composition percent of BMA and MMA was 5.15% in total. Swelling ratio and water contents increased with decreasing of BMA (Butyl methacrylate) and MMA (Methyl methacrylate) percent. In the composition of HEMA/Silicone/MMA, the values of ultimate strength increased with increasing of silicone percent to 4-MMA sample. In the composition of HEMA/Silicone/BMA, the values of ultimate strength decreased with increasing of silicone percent.

  • PDF

Resistive Humidity Sensor from Copolymers Containing Quaternary Ammonium Salt (I): Three Component Copolymers (4차 암모늄염을 포함하는 공중합체를 이용한 저항형 습도센서(I) : 3원 공중합체)

  • Lee, Dong-Geun;Lim, Tae-Ho;Jeon, Young-Min;Gong, Myoung-Seon
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.194-200
    • /
    • 2007
  • The resistive-type polymeric humidity sensors were prepared from the copolymers of [2- [(methacryloyloxy)ethyl] dimethyl] propylammonium bromide(MEPAB), [2- [(methacryloyloxy)ethyl]-2-hydroxyethyl]dimethylmonium bromide (MEHDAB), n-butyl methylacrylate(MBA), 2-hydroxyethyl methylacrylate(HEMA) and styrene. Four kinds of copolymers, ie, MEPAB/styrene/MEHDAB MEHDAB/BMA/HEMA, MEPAB/BMA/MEHDAB, and MEPAB/styrene/HEMA crosslinked with blocked-isocyanate on the Ag/Pd electrode/alumina substrate showed good durability at high humidities. The various electrical properties such as frequency dependency, temperature dependency, hysteresis, response time and water durability were examined. In the case of copolymer MEPAB/BMA/MEHDAB= 3/6/1, the resistance was varied from $2.9 M{\Omega}$ to $1.84k{\Omega}$ at $25^{\circ}C$ in the range of $30{\sim}90%RH$ and this copolymers showed a good linearity and low hysteresis.

Polymerization of Hydrogel Contact Lens with High Oxygen Transmissibility (산소투과성이 뛰어난 Hydrogel 콘택트렌즈 합성)

  • Sung, A-Young;Kim, Tae-Hun;Kong, Jung-Il
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.1
    • /
    • pp.49-53
    • /
    • 2006
  • Acrylate -PDMS(Polydimethylsiloxane)-Urethane Prepolymer is synthesized through treating diisocynate, HEMA(2-hydroxyethylmethacrylate) and bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) having high oxygen permeability under the DBTDL(Dibutylitin dilaurate) catalyst. Modification of HEMA on bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) is to be able to polymerize with other contact lens materials. And modification of urethane on bis(hydroxyalkyl)terminated Poly(dimethylsiloxane) is to increase elastic property and oxygen transmissibility. This material is analyzed by FT-IR and also will be used to make hydrogel contact lens.

  • PDF

Some Model Solute Affinity for a Tactic p-HEMA Membranes by K$_D$ Measurement

  • Lee, Eun-Hee;Jeon, Sang-Il;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.5
    • /
    • pp.175-178
    • /
    • 1984
  • Two series of membranes have been prepared by postcrosslinking highly syndiotactic and isotactic poly (2-hydroxyethyl methacrylate), P(HEMA). The crosslinker used was hexamethylene diisocyante (HMDIC). The distribution coefficients (K$_{D2}$) of the model solutes such as urea (and thiourea), their derivatives, homologous alcohol series and amide sreies in water-swollen tactic P(HEMA) membranes at $25^{\circ}C$ were mesaured. In addition, the concentration effects of acetamide and butyramid were also measured. On the basis of hydrophobic interaction and the structural factors of tactic P(HEMA) membranes, the hydrophobic adsorption of the solutes in the polymer matrix were discussed. The results showed that the more hydrphobic the solute is, the higher the $K_{D2}$ value is. And the polymer conformation also affects the distribution of solvents.

Synthesis and Characteristics of Unsaturated Polyester Modified with Rosin Containing 2-Hydroxyethylmethacrylate (2-Hydroxyethylmethacrylate가 도입된 로진 변성 불포화 폴리에스테르의 합성과 그 특성)

  • Kang, D.W.;Yoon, D.K.;Kweon, D.K..
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.450-455
    • /
    • 1999
  • Unsaturated diol (UD) was prepared from the esterification of maleic anhydride with diethylene glycol (DEG). Unsaturated polyesters modified with rosin (UPMR) or with rosin maleic anhydride adduct (RMA) from 2-hydroxyethylmethacrylate (HEMA) and rosin (UPMRH) were prepared by the reaction of UD with RMA or RMA-HEMA. After crosslinking of UPMR and UPMRH with styrene and methylmethacrylate (MMA), respectively, solvent resistance, tensile strength, and adhesion property of the resins were measured. UPMR crosslinked with styrene or MMA shows an excellent resistance to water and acid. Solvents resistance and tensile strength of UPMR using styrene as crosslinking agent were increased compared with those of UPMR using MMA as crosslinking agent. UPMRH showed better solvents resistance and tensile strength than UPMR. Adhesion strengths of UPMR crosslinked with styrene and MMA were 1.61 and 3.02 MPa, and those of UPMRH were 2.32 and 3.89 MPa, respectively.

  • PDF

Hydrophilic Modification of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization and Water Permeability (방사선 조사 그라프트중합에 의한 폴리프로필렌 정밀여과막의 친수화 및 물 투과특성)

  • Park, Jae-Hyung;Lee, Kune-Woo;Hwang, Taek-Sung;Lee, Jae-Won;Oh, Won-Jin
    • Applied Chemistry for Engineering
    • /
    • v.10 no.6
    • /
    • pp.954-959
    • /
    • 1999
  • Radiation-induced grafting of 2-hydroxyethyl methacrylate(HEMA), acrylic acid(AAc) and methacrylic acid(MAAc) onto polypropylene microfiltration membrane has been studied. The effect of grafting conditions such as solvent composition(MeOH and $H_2O$) and monomer concentration on the grafting yield in investigated. The highest degree of grafting is obtained at a solvent composition of 25% $H_2O$:75% MeOH for HEMA, pure water for AAc and 50% $H_2O$:50% MeOH for MAAc. Modification of the PP membranes with hydrophilic monomers is shown to cause an increase in the water permeation flux of the membranes. It is found that HEMA is the best monomer to increase the water permeation flux and the highest water permeation flux is obtained at 99% degree of grafting. The water permeation flux of AAc-grafted PP membrane and MAAc-grafted PP membrane is very sensitive to environmental pH and $Cu^{2+}$ ion, but the water permeation flux of HEMA-grafted PP membrane scarcely depends on pH and $Cu^{2+}$ ion.

  • PDF

Utility of a multiplex reverse transcriptase-polymerase chain reaction assay (HemaVision) in the evaluation of genetic abnormalities in Korean children with acute leukemia: a single institution study

  • Kim, Hye-Jin;Oh, Hyun Jin;Lee, Jae Wook;Jang, Pil-Sang;Chung, Nack-Gyun;Kim, Myungshin;Lim, Jihyang;Cho, Bin;Kim, Hack-Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.6
    • /
    • pp.247-253
    • /
    • 2013
  • Purpose: In children with acute leukemia, bone marrow genetic abnormalities (GA) have prognostic significance, and may be the basis for minimal residual disease monitoring. Since April 2007, we have used a multiplex reverse transcriptase-polymerase chain reaction tool (HemaVision) to detect of GA. Methods: In this study, we reviewed the results of HemaVision screening in 270 children with acute leukemia, newly diagnosed at The Catholic University of Korea from April 2007 to December 2011, and compared the results with those of fluorescence in situ hybridization (FISH), and G-band karyotyping. Results: Among the 270 children (153 males, 117 females), 187 acute lymphoblastic leukemia and 74 acute myeloid leukemia patients were identified. Overall, GA was detected in 230 patients (85.2%). HemaVision, FISH, and G-band karyotyping identified GA in 125 (46.3%), 126 (46.7%), and 215 patients (79.6%), respectively. TEL-AML1 (20.9%, 39/187) and AML1-ETO (27%, 20/74) were the most common GA in ALL and AML, respectively. Overall sensitivity of HemaVision was 98.4%, with false-negative results in 2 instances: 1 each for TEL-AML1 and MLL-AF4. An aggregate of diseases-specific FISH showed 100% sensitivity in detection of GA covered by HemaVision for actual probes utilized. G-band karyotype revealed GA other than those covered by HemaVison screening in 133 patients (49.3%). Except for hyperdiplody and hypodiploidy, recurrent GA as defined by the World Health Organizationthat were not screened by HemaVision, were absent in the karyotype. Conclusion: HemaVision, supported by an aggregate of FISH tests for important translocations, may allow for accurate diagnosis of GA in Korean children with acute leukemia.