• Title/Summary/Keyword: 2-Dimensional

Search Result 15,239, Processing Time 0.049 seconds

Preparation and Performance of Aluminosilicate Fibrous Porous Ceramics Via Vacuum Suction Filtration

  • Qingqing Wang;Shaofeng Zhu;Zhenfan Chen;Tong Zhang
    • Korean Journal of Materials Research
    • /
    • v.34 no.1
    • /
    • pp.12-20
    • /
    • 2024
  • This study successfully prepared high-porosity aluminosilicate fibrous porous ceramics through vacuum suction filtration using aluminosilicate fiber as the primary raw material and glass powder as binder, with the appropriate incorporation of glass fiber. The effects of the composition of raw materials and sintering process on the structure and properties of the material were studied. The results show that when the content of glass powder reached 20 wt% and the samples were sintered at the temperature of 1,000 ℃, strong bonds were formed between the binder phase and fibers, resulting in a compressive strength of 0.63 MPa. When the sintering temperatures were increased from 1,000 ℃ to 1,200, the open porosity of the samples decreased from 89.08 % to 82.38 %, while the linear shrinkage increased from 1.13 % to 10.17 %. Meanwhile, during the sintering process, a large amount of cristobalite and mullite were precipitated from the aluminosilicate fibers, which reduced the performance of the aluminosilicate fibers and hindered the comprehensive improvement in sample performance. Based on these conditions, after adding 30 wt% glass fiber and being sintered at 1,000 ℃, the sample exhibited higher compressive strength (1.34 MPa), higher open porosity (89.13 %), and lower linear shrinkage (5.26 %). The aluminosilicate fibrous porous ceramic samples exhibited excellent permeability performance due to their high porosity and interconnected three-dimensional pore structures. When the samples were filtered at a flow rate of 150 mL/min, the measured pressure drop and permeability were 0.56 KPa and 0.77 × 10-6 m2 respectively.

Rotation Control of Shoulder Joint During Shoulder Internal Rotation: A Comparative Study of Individuals With and Without Restricted Range of Motion

  • Min-jeong Chang;Jun-hee Kim;Ui-jae Hwang;Il-kyu Ahn;Oh-yun Kwon
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2024
  • Background: Limitations of shoulder range of motion (ROM), particularly shoulder internal rotation (SIR), are commonly associated with musculoskeletal disorders in both the general population and athletes. The limitation can result in connective tissue lesions such as superior labrum tears and symptoms such as rotator cuff tears and shoulder impingement syndrome. Maintaining the center of rotation of the glenohumeral joint during SIR can be challenging due to the compensatory scapulothoracic movement and anterior displacement of the humeral head. Therefore, observing the path of the instantaneous center of rotation (PICR) using the olecranon as a marker during SIR may provide valuable insights into understanding the dynamics of the shoulder joint. Objects: The aim of the study was to compare the displacement of the olecranon to measure the rotation control of the humeral head during SIR in individuals with and without restricted SIR ROM. Methods: Twenty-four participants with and without restricted SIR ROM participated in this study. The displacement of olecranon was measured during the shoulder internal rotation control test (SIRCT) using a Kinovea (ver. 0.8.15, Kinovea), the 2-dimensional marker tracking analysis system. An independent t-test was used to compare the horizontal and vertical displacement of the olecranon marker between individuals with and without restricted SIR ROM. The statistical significance was set at p < 0.05. Results: Vertical displacement of the olecranon was significantly greater in the restricted SIR group than in the control group (p < 0.05). However, no significant difference was observed in the horizontal displacement of the olecranon (p > 0.05). Conclusion: The findings of this study indicated that individuals with restricted SIR ROM had significantly greater vertical displacement of the olecranon. The results suggest that the limitation of SIR ROM may lead to difficulty in rotation control of the humeral head.

Study on the Application of Patterns of Xuzhou Paper-cut in Cultural and Creative Product Design (쉬저우(徐州) 지엔즈(剪紙) 문양(紋樣)의 문화 창작물 제품 디자인 적용에 관한 연구)

  • Hao Pei Pei;Lee Jin Wook
    • Smart Media Journal
    • /
    • v.12 no.11
    • /
    • pp.211-221
    • /
    • 2023
  • In the context of integration of culture and tourism, the effective application of folk art in cultural creative products is of great significance to the development of local cultural industry. Xuzhou paper-cutting is the only world-class intangible cultural heritage project in the northern Jiangsu region of China. Its high humanistic value and artistic characteristics are widely used in modern art design. The application of cultural and creative products relative to paper-cutting in Xuzhou mainly focuses on two-dimensional decorative and ornamental products, which is short of diversity in form and not practical. In addition, it doesn't meet the aesthetic needs of living of modern people, This article studies paper-cut works by Wang Guiying and proposes principles for the design of cultural and creative products relative to paper-cutting by analyzing the typical "goose" pattern in Wang's paper cutting handcrafts. By exploring the application value of Xuzhou paper-cutting in cultural and creative product design and demonstrating the feasibility of the design principles via visiting experts, this article hopes to provide some reference for the modern inheritance and innovative development of paper-cutting culture.

Whole Body Shape Analysis for Virtual Human Body Modeling - Focusing on obese women in their 20s and 30s - (가상 인체 모델링을 위한 전신 체형 연구 - 20-30대 비만여성을 중심으로 -)

  • Eun-Hee Hong;Yoon Ji Won
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.4
    • /
    • pp.147-161
    • /
    • 2023
  • This study used 3D anthropometric data from the 8th Size Korea to type and analyze whole body shapes of obese women in their 20s and 30s, and constructed dimensional data for human body items needed to create a 3D human body model for each type. The data analysis used data from 148 obese women in their 20s and 30s, and a total of 48 index values, drop values, and angle items were subjected to factor analysis and one-way variance analysis to categorize body types and verify significant differences by type. As a result of the factor analysis, 12 factors were extracted and divided into 4 body types. Type 1 is a 'standard type with a curved torso with balanced upper and lower body lengths', Type 2 is a 'bending forward type with a short, thick lower body, and an uncurved torso', Type 3 is a 'lean back type with a long and thin lower body and an H-shape torso', Type 4 is a 'sway back type with a long and thick lower body and abdominal obesity'. The representative body type of obese women in their 20s and 30s was identified as Type 1. The constructed body shape information will be used as basic data for future 3D human body modeling.

Automated Segmentation of Left Ventricular Myocardium on Cardiac Computed Tomography Using Deep Learning

  • Hyun Jung Koo;June-Goo Lee;Ji Yeon Ko;Gaeun Lee;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.660-669
    • /
    • 2020
  • Objective: To evaluate the accuracy of a deep learning-based automated segmentation of the left ventricle (LV) myocardium using cardiac CT. Materials and Methods: To develop a fully automated algorithm, 100 subjects with coronary artery disease were randomly selected as a development set (50 training / 20 validation / 30 internal test). An experienced cardiac radiologist generated the manual segmentation of the development set. The trained model was evaluated using 1000 validation set generated by an experienced technician. Visual assessment was performed to compare the manual and automatic segmentations. In a quantitative analysis, sensitivity and specificity were calculated according to the number of pixels where two three-dimensional masks of the manual and deep learning segmentations overlapped. Similarity indices, such as the Dice similarity coefficient (DSC), were used to evaluate the margin of each segmented masks. Results: The sensitivity and specificity of automated segmentation for each segment (1-16 segments) were high (85.5-100.0%). The DSC was 88.3 ± 6.2%. Among randomly selected 100 cases, all manual segmentation and deep learning masks for visual analysis were classified as very accurate to mostly accurate and there were no inaccurate cases (manual vs. deep learning: very accurate, 31 vs. 53; accurate, 64 vs. 39; mostly accurate, 15 vs. 8). The number of very accurate cases for deep learning masks was greater than that for manually segmented masks. Conclusion: We present deep learning-based automatic segmentation of the LV myocardium and the results are comparable to manual segmentation data with high sensitivity, specificity, and high similarity scores.

Evaluation of Tracheobronchial Diseases: Comparison of Different Imaging Techniques

  • Qihang Chen;Jin Mo Goo;Joon Beom Seo;Myung Jin Chung;Yu-Jin Lee;Jung-Gi Im
    • Korean Journal of Radiology
    • /
    • v.1 no.3
    • /
    • pp.135-141
    • /
    • 2000
  • Objective: To compare the clinical utility of the different imaging techniques used for the evaluation of tracheobronchial diseases. Materials and Methods: Forty-one patients with tracheobronchial diseases [tuberculosis (n = 18), bronchogenic carcinoma (n = 10), congenital abnormality (n = 3), post-operative stenosis (n = 2), and others (n = 8)] underwent chest radiography and spiral CT. Two sets of scan data were obtained: one from routine thick-section axial images and the other from thin-section axial images. Multiplanar reconstruction (MPR) and shaded surface display (SSD) images were obtained from thin-section data. Applying a 5-point scale, two observers compared chest radiography, routine CT, thin-section spiral CT, MPR and SSD imaging with regard to the detection, localization, extent, and characterization of a lesion, information on its relationship with adjacent structures, and overall information. Results: SSD images were the most informative with regard to the detection (3.95±0.31), localization (3.95±0.22) and extent of a lesion (3.85±0.42), and overall information (3.83±0.44), while thin-section spiral CT scans provided most information regarding its relationship with adjacent structures (3.56±0.50) and characterization of the lesion (3.51±0.61). Conclusion: SSD images and thin-section spiral CT scans can provide valuable information for the evaluation of tracheobronchial disease.

  • PDF

Changes in Cardiac Structure and Function After Kidney Transplantation: A New Perspective Based on Strain Imaging

  • Darae Kim;Minjeong Kim;Jae Berm Park;Juhan Lee;Kyu Ha Huh;Geu-Ru Hong;Jong-Won Ha;Jin-Oh Choi;Chi Young Shim
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.98-104
    • /
    • 2023
  • BACKGROUND: We aimed to investigate left ventricular (LV) global longitudinal strain (GLS) in end-stage renal disease patients and its change after kidney transplantation (KT). METHODS: We retrospectively reviewed patients who underwent KT between 2007 and 2018 at two tertiary centers. We analyzed 488 patients (median age, 53 years; 58% male) who had obtained echocardiography both before and within 3 years after KT. Conventional echocardiography and LV GLS assessed by two-dimensional speckle-tracking echocardiography were comprehensively analyzed. Patients were classified into three groups according to the absolute value of pre-KT LV GLS (|LV GLS|). We compared longitudinal changes of cardiac structure and function according to pre-KT |LV GLS|. RESULTS: Correlation between pre-KT LV EF and |LV GLS| were statistically significant, but the constant was not high (r = 0.292, p < 0.001). |LV GLS| was widely distributed at corresponding LV EF, especially when the LV EF was > 50%. Patients with severely impaired pre-KT |LV GLS| had significantly larger LV dimension, LV mass index, left atrial volume index, and E/e' and lower LV EF, compared to mildly and moderately reduced pre-KT |LV GLS|. After KT, the LV EF, LV mass index, and |LV GLS| were significantly improved in three groups. Patients with severely impaired pre-KT |LV GLS| showed the most prominent improvement of LV EF and |LV GLS| after KT, compared to other groups. CONCLUSIONS: Improvements in LV structure and function after KT were observed in patients throughout the full spectrum of pre-KT |LV GLS|.

Investigations of countermeasures used to mitigate tunnel deformations due to adjacent basement excavation in soft clays

  • Jinhuo Zheng;Minglong Shen;Shifang Tu;Zhibo Chen;Xiaodong Ni
    • Geomechanics and Engineering
    • /
    • v.36 no.6
    • /
    • pp.563-573
    • /
    • 2024
  • In this study, various countermeasures used to mitigate tunnel deformations due to nearby multi-propped basement excavation in soft clay are explored by three-dimensional numerical analyses. Field measurements are used to calibrate the numerical model and model parameters. Since concrete slabs can constrain soil and retaining wall movements, tunnel movements reach the maximum value when soils are excavated to the formation level of basement. Deformation shapes of an existing tunnel due to adjacent basement excavation are greatly affected by relative position between tunnel and basement. When the tunnel is located above or far below the formation level of basement, it elongates downward-toward or upward-toward the basement, respectively. It is found that tunnel movements concentrate in a triangular zone with a width of 2 He (i.e., final excavation depth) and a depth of 1 D (i.e., tunnel diameter) above or 1 D below the formation level of basement. By increasing retaining wall thickness from 0.4 m to 0.9 m, tunnel movements decrease by up to 56.7%. Moreover, tunnel movements are reduced by up to 80.7% and 61.3%, respectively, when the entire depth and width of soil within basement are reinforced. Installation of isolation wall can greatly reduce tunnel movements due to adjacent basement excavation, especially for tunnel with a shallow burial depth. The effectiveness of isolation wall to reduce tunnel movement is negligible unless the wall reaches the level of tunnel invert.

Rotordynamic Analysis Using a Direction Frequency Response Function (방향성 주파수 응답 함수를 이용한 회전체 동역학 해석)

  • Donghyun, Lee;Byungchan, Jeon ;Byungock, Kim;Hyungsoo, Lim
    • Journal of Domestic Journal Test
    • /
    • v.11 no.2
    • /
    • pp.221-227
    • /
    • 2023
  • − A rotordynamic system consists of components that undergo rotational motion. These components include shafts, impellers, thrust collars, and components that support rotation, such as bearings and seals. The motion of this type of rotating system can be modeled as two-dimensional motion and, accordingly, the equa- tion of motion for the rotordynamic system can be represented using complex coordinates. The directional fre- quency response function (dFRF) can be derived from this complex coordinate system and used as an effective analytical tool for rotating machinery. However, the dFRF is not widely used in the field because most pre- vious studies and commercial software are based on real coordinate systems. The objective of the current study is to introduce the dFRF and show that it can be an effective tool in rotordynamic analysis. In this study, the normal frequency response function (nFRF) and dFRF are compared under rotordynamic analysis for isotropic and unisotropic rotors. Results show that in the nFRF, the magnitude of the response is the same for both pos- itive and negative frequencies, and the response is similar under all modes. Consequently, the severity of the mode cannot be identified. However, in the dFRF, the forward and backward modes are clearly distinguishable in the frequency domain of the isotropic rotor, and the severity of the mode can be identified for the uniso- tropic rotor.

Essential Guidelines for Manufacturing and Application of Organoids

  • Sun-Ju Ahn;Sungin Lee;Dayeon Kwon;Sejeong Oh;Chihye Park;Sooyeon Jeon;Jin Hee Lee;Tae Sung Kim;Il Ung Oh
    • International Journal of Stem Cells
    • /
    • v.17 no.2
    • /
    • pp.102-112
    • /
    • 2024
  • An organoid is a self-organized three-dimensional structure derived from stem cells that mimics the structure, cell composition, and functional characteristics of specific organs and tissues and is used for evaluating the safety and effectiveness of drugs and the toxicity of industrial chemicals. Organoid technology is a new methodology that could replace testing on animals testing and accelerate development of precision and regenerative medicine. However, large variations in production can occur between laboratories with low reproducibility of the production process and no internationally agreed standards for quality evaluation factors at endpoints. To overcome these barriers that hinder the regulatory acceptance and commercialization of organoids, Korea established the Organoid Standards Initiative in September 2023 with various stakeholders, including industry, academia, regulatory agencies, and standard development experts, through public and private partnerships. This developed general guidelines for organoid manufacturing and quality evaluation and for quality evaluation guidelines for organoid-specific manufacturing for the liver, intestines, and heart through extensive evidence analysis and consensus among experts. This report is based on the common standard guideline v1.0, which is a general organoid manufacturing and quality evaluation to promote the practical use of organoids. This guideline does not focus on specific organoids or specific contexts of use but provides guidance to organoid makers and users on materials, procedures, and essential quality assessment methods at end points that are essential for organoid production applicable at the current technology level.