• Title/Summary/Keyword: 2-D and 3-D Methods

Search Result 5,748, Processing Time 0.041 seconds

Studies on Relations between Various Coeffcients of Evapo-Transpiration and Quantities of Dry Matters for Tall-and Short Statured Varieties of Paddy Rice (논벼 장.단간품종의 증발산제계수와 건물량과의 관계에 대한 연구(I))

  • 류한열;김철기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.2
    • /
    • pp.3361-3394
    • /
    • 1974
  • The purpose of this thesis is to disclose some characteristics of water consumption in relation to the quantities of dry matters through the growing period for two statured varieties of paddy rice which are a tall statured variety and a short one, including the water consumption during seedling period, and to find out the various coefficients of evapotranspiration that are applicable for the water use of an expected yield of the two varieties. PAL-TAL, a tall statured variety, and TONG-lL, a short statured variety were chosen for this investigation. Experiments were performed in two consecutive periods, a seedling period and a paddy field period, In the investigation of seedling period, rectangular galvanized iron evapotranspirometers (91cm${\times}$85cm${\times}$65cm) were set up in a way of two levels (PAL-TAL and TONG-lL varieties) with two replications. A standard fertilization method was applied to all plots. In the experiment of paddy field period, evapotanspiration and evaporation were measured separately. For PAL-TAL variety, the evapotranspiration measurements of 43 plots of rectangular galvanized iron evapotranspirometer (91cm${\times}$85cm${\times}$65cm) and the evaporation measurements of 25 plots of rectangular galvanized iron evaporimeter (91cm${\times}$85cm${\times}$15cm) have been taken for seven years (1966 through 1972), and for TONG-IL variety, the evapotranspiration measurements of 19 plots and the evaporation measurements of 12 plots have been collected for two years (1971 through 1972) with five different fertilization levels. The results obtained from this investigation are summarized as follows: 1. Seedling period 1) The pan evaporation and evapotranspiration during seedling period were proved to have a highly significant correlation to solar radiation, sun shine hours and relative humidity. But they had no significant correlation to average temperature, wind velocity and atmospheric pressure, and were appeared to be negatively correlative to average temperature and wind velocity, and positively correlative to the atmospheric pressure, in a certain period. There was the highest significant correlation between the evapotranspiration and the pan evaporation, beyond all other meteorological factors considered. 2) The evapotranpiration and its coefficient for PAL-TAL variety were 194.5mm and 0.94∼1.21(1.05 in average) respectively, while those for TONG-lL variety were 182.8mm and 0.90∼1.10(0.99 in average) respectively. This indicates that the evapotranspiration for TONG-IL variety was 6.2% less than that for PAL-TAL variety during a seedling period. 3) The evapotranspiration ratio (the ratio of the evapotranspiration to the weight of dry matters) during the seedling period was 599 in average for PAL-TAL variety and 643 for TONG-IL variety. Therefore the ratio for TONG-IL was larger by 44 than that for PAL-TAL variety. 4) The K-values of Blaney and Criddle formula for PAL-TAL variety were 0.78∼1.06 (0.92 in average) and for TONG-lL variety 0.75∼0.97 (0.86 in average). 5) The evapotranspiration coefficient and the K-value of B1aney and Criddle formular for both PAL-TAL and TONG-lL varieties showed a tendency to be increasing, but the evapotranspiration ratio decreasing, with the increase in the weight of dry matters. 2. Paddy field period 1) Correlation between the pan evaporation and the meteorological factors and that between the evapotranspiration and the meteorological factors during paddy field period were almost same as that in case of the seedling period (Ref. to table IV-4 and table IV-5). 2) The plant height, in the same level of the weight of dry matters, for PAL-TAL variety was much larger than that for TONG-IL variety, and also the number of tillers per hill for PAL-TAL variety showed a trend to be larger than that for TONG-IL variety from about 40 days after transplanting. 3) Although there was a tendency that peak of leaf-area-index for TONG-IL variety was a little retarded than that for PAL-TAL variety, it appeared about 60∼80 days after transplanting. The peaks of the evapotranspiration coefficient and the weight of dry matters at each growth stage were overlapped at about the same time and especially in the later stage of growth, the leaf-area-index, the evapotranspiration coefficient and the weight of dry matters for TONG-IL variety showed a tendency to be larger then those for PAL-TAL variety. 4) The evaporation coefficient at each growth stage for TONG-IL and PAL-TALvarieties was decreased and increased with the increase and decrease in the leaf-area-index, and the evaporation coefficient of TONG-IL variety had a little larger value than that of PAL-TAL variety. 5) Meteorological factors (especially pan evaporation) had a considerable influence to the evapotranspiration, the evaporation and the transpiration. Under the same meteorological conditions, the evapotranspiration (ET) showed a increasing logarithmic function of the weight of dry matters (x), while the evaporation (EV) a decreasing logarithmic function of the weight of dry matters; 800kg/10a x 2000kg/10a, ET=al+bl logl0x (bl>0) EV=a2+b2 log10x (a2>0 b2<0) At the base of the weight of total dry matters, the evapotranspiration and the evaporation for TONG-IL variety were larger as much as 0.3∼2.5% and 7.5∼8.3% respectively than those of PAL-TAL variety, while the transpiration for PAL-TAL variety was larger as much as 1.9∼2.4% than that for TONG-IL variety on the contrary. At the base of the weight of rough rices the evapotranspiration and the transpiration for TONG-IL variety were less as much as 3.5% and 8.l∼16.9% respectively than those for PAL-TAL variety and the evaporation for TONG-IL was much larger by 11.6∼14.8% than that for PAL-TAL variety. 6) The evapotranspiration coefficient, the evaporation coefficient and the transpiration coefficient and the transpiration coefficient were affected by the weight of dry matters much more than by the meteorological conditions. The evapotranspiratioa coefficient (ETC) and the evaporation coefficient (EVC) can be related to the weight of dry matters (x) by the following equations: 800kg/10a x 2000kg/10a, ETC=a3+b3 logl0x (b3>0) EVC=a4+b4 log10x (a4>0, b4>0) At the base of the weights of dry matters, 800kg/10a∼2000kg/10a, the evapotranspiration coefficients for TONG-IL variety were 0.968∼1.474 and those for PAL-TAL variety, 0.939∼1.470, the evaporation coefficients for TONG-IL variety were 0.504∼0.331 and those for PAL-TAL variety, 0.469∼0.308, and the transpiration coefficients for TONG-IL variety were 0.464∼1.143 and those for PAL-TAL variety, 0.470∼1.162. 7) The evapotranspiration ratio, the evaporation ratio (the ratio of the evaporation to the weight of dry matters) and the transpiration ratio were highly affected by the meteorological conditions. And under the same meteorological condition, both the evapotranspiration ratio (ETR) and the evaporation ratio (EVR) showed to be a decreasing logarithmic function of the weight of dry matters (x) as follows: 800kg/10a x 2000kg/10a, ETR=a5+b5 logl0x (a5>0, b5<0) EVR=a6+b6 log10x (a6>0 b6<0) In comparison between TONG-IL and PAL-TAL varieties, at the base of the pan evaporation of 343mm and the weight of dry matters of 800∼2000kg/10a, the evapotranspiration ratios for TONG-IL variety were 413∼247, while those for PAL-TAL variety, 404∼250, the evaporation ratios for TONG-IL variety were 197∼38 while those for PAL-TAL variety, 182∼34, and the transpiration ratios for TONG-IL variety were 216∼209 while those for PAL-TAL variety, 222∼216 (Ref. to table IV-23, table IV-25 and table IV-26) 8) The accumulative values of evapotranspiration intensity and transpiration intensity for both PAL-TAL and TONG-IL varieties were almost constant in every climatic year without the affection of the weight of dry matters. Furthermore the evapotranspiration intensity appeared to have more stable at each growth stage. The peaks of the evapotranspiration intensity and transpiration intensity, for both TONG-IL and PAL-TAL varieties, appeared about 60∼70 days after transplanting, and the peak value of the former was 128.8${\pm}$0.7, for TONG-IL variety while that for PAL-TAL variety, 122.8${\pm}$0.3, and the peak value of the latter was 152.2${\pm}$1.0 for TONG-IL variety while that for PAL-TAL variety, 152.7${\pm}$1.9 (Ref.to table IV-27 and table IV-28) 9) The K-value in Blaney & Criddle formula was changed considerably by the meteorological condition (pan evaporation) and related to be a increasing logarithmic function of the weight of dry matters (x) for both PAL-TAL and TONG-L varieties as follows; 800kg/10a x 2000kg/10a, K=a7+b7 logl0x (b7>0) The K-value for TONG-IL variety was a little larger than that for PAL-TAL variety. 10) The peak values of the evapotranspiration coefficient and k-value at each growth stage for both TONG-IL and PAL-TAL varieties showed up about 60∼70 days after transplanting. The peak values of the former at the base of the weights of total dry matters, 800∼2000kg/10a, were 1.14∼1.82 for TONG-IL variety and 1.12∼1.80, for PAL-TAL variety, and at the base of the weights of rough rices, 400∼1000 kg/10a, were 1.11∼1.79 for TONG-IL variety and 1.17∼1.85 for PAL-TAL variety. The peak values of the latter, at the base of the weights of total dry matters, 800∼2000kg/10a, were 0.83∼1.39 for TONG-IL variety and 0.86∼1.36 for PAL-TAL variety and at the base of the weights of rough rices, 400∼1000kg/10a, 0.85∼1.38 for TONG-IL variety and 0.87∼1.40 for PAL-TAL variety (Ref. to table IV-18 and table IV-32) 11) The reasonable and practicable methods that are applicable for calculating the evapotranspiration of paddy rice in our country are to be followed the following priority a) Using the evapotranspiration coefficients based on an expected yield (Ref. to table IV-13 and table IV-18 or Fig. IV-13). b) Making use of the combination method of seasonal evapotranspiration coefficient and evapotranspiration intensity (Ref. to table IV-13 and table IV-27) c) Adopting the combination method of evapotranspiration ratio and evapotranspiration intensity, under the conditions of paddy field having a higher level of expected yield (Ref. to table IV-23 and table IV-27). d) Applying the k-values calculated by Blaney-Criddle formula. only within the limits of the drought year having the pan evaporation of about 450mm during paddy field period as the design year (Ref. to table IV-32 or Fig. IV-22).

  • PDF

Effects of Motion Correction for Dynamic $[^{11}C]Raclopride$ Brain PET Data on the Evaluation of Endogenous Dopamine Release in Striatum (동적 $[^{11}C]Raclopride$ 뇌 PET의 움직임 보정이 선조체 내인성 도파민 유리 정량화에 미치는 영향)

  • Lee, Jae-Sung;Kim, Yu-Kyeong;Cho, Sang-Soo;Choe, Yearn-Seong;Kang, Eun-Joo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.6
    • /
    • pp.413-420
    • /
    • 2005
  • Purpose: Neuroreceptor PET studies require 60-120 minutes to complete and head motion of the subject during the PET scan increases the uncertainty in measured activity. In this study, we investigated the effects of the data-driven head mutton correction on the evaluation of endogenous dopamine release (DAR) in the striatum during the motor task which might have caused significant head motion artifact. Materials and Methods: $[^{11}C]raclopride$ PET scans on 4 normal volunteers acquired with bolus plus constant infusion protocol were retrospectively analyzed. Following the 50 min resting period, the participants played a video game with a monetary reward for 40 min. Dynamic frames acquired during the equilibrium condition (pre-task: 30-50 min, task: 70-90 min, post-task: 110-120 min) were realigned to the first frame in pre-task condition. Intra-condition registrations between the frames were performed, and average image for each condition was created and registered to the pre-task image (inter-condition registration). Pre-task PET image was then co-registered to own MRI of each participant and transformation parameters were reapplied to the others. Volumes of interest (VOI) for dorsal putamen (PU) and caudate (CA), ventral striatum (VS), and cerebellum were defined on the MRI. Binding potential (BP) was measured and DAR was calculated as the percent change of BP during and after the task. SPM analyses on the BP parametric images were also performed to explore the regional difference in the effects of head motion on BP and DAR estimation. Results: Changes in position and orientation of the striatum during the PET scans were observed before the head motion correction. BP values at pre-task condition were not changed significantly after the intra-condition registration. However, the BP values during and after the task and DAR were significantly changed after the correction. SPM analysis also showed that the extent and significance of the BP differences were significantly changed by the head motion correction and such changes were prominent in periphery of the striatum. Conclusion: The results suggest that misalignment of MRI-based VOI and the striatum in PET images and incorrect DAR estimation due to the head motion during the PET activation study were significant, but could be remedied by the data-driven head motion correction.

Study on the Herb Remedies of ENT, Eyes, Teeth and Skin Problems (이비인후, 안, 치아 및 피부증상의 민간요법에 관한 고찰)

  • Cho, Kyoul-Ja;Kang, Hyun-Sook
    • Journal of East-West Nursing Research
    • /
    • v.1 no.1
    • /
    • pp.50-71
    • /
    • 1997
  • The intention of this study is to apprehend the con. tents and methods of herb remedies that are commonly conducted when there are health-problem cases of ENT, eyes, teeth and skin. Methods of this study are divided into two stages : 1) For a period of six months from December 1994 to June 1995, some 40 persons who are believed to be well versed with herb remedies have been randomly chosen, and we made a survey on herb remedies by symptoms: and 2) we have endeavored to make their grounds evident through the studies on literatures with the focus on the basic data collected. Their results are as follows: 1) When one feels a pain in ears, such herb remedies are employed as pouring the vapor into ears, which is made by steaming Alaska pollack, or as applying or wiping with the juices of radish or the ginkgo, or' alum. Applying the radish juice is effective for sterilization and fever removal: and applying the ginkgo juice is effective for cleanliness. But, plastering alum, sesame oil or castor oil, or pouring the vapor of Alaska pollack into ears are perhaps effective but do not have any pharmacologic grounds. 2) When one bleeds at the nose, such kinds of herb remedies are applied as stimulating nose or head with cold water, pressing nose or ridge of nose, or filling up nares with mashed mugworts. In addition, they have utilized garlic or leeks. Such methods as stimulating with cold water or just pressing nose and ridge of nose is based on reasonable grounds, i.e. vasoconstriction and vascular compression ; and applying mashed garlic on the sole of foot is good for the circulation of Qui ; and the use of mugworts and leeks is based upon the pharmacological function of hemostasis. 3) When one feels a sore throat such kinds of herb remedies are employed as gargling or rinsing throat with brine, drinking hot gruel or water, or drinking the juice of mugwort, radish, ginger or Chinese quince. Gargling with brine or drinking the juice of mugwort, radish or ginger is based upon the pharmacological function of pain alleviation, fever removal, and detoxication. 4) When a boil is formed in mouth, such herb remedies are applied as spreading honey, brine or alum water, and taking gall nut, Chinese matrimony vine, lotus root, etc, for drugs. Spreading honey, brine or water that is made by infusing gallnut, Chinese matrimony vine, lotus root is based upon such functions as hematosis, astriction, antibacterial, and antiphlogistic, Alum, eggplant and licorice are said to be effective, but their pharmacological effects have no grounds. 5) When one has conjunctivitis such herb remedies are commonly applied as irrigation with brine and dropping breast milk in eyes. Moreover, such other drugs are used as plantain. shepherd's purse, and purslane, etc. The use of brine, breast milk, plantain, shepherd's purse and purslane is based upon such functions as sterilization, antiphlogistic, disinfection and pain relieving. Eriocaulon sieboldianum, bean stem, bean pod and narcissus leaves are said to be effective, but their pharmacological action have no basis. When one has a stye, such herb remedies are applied as extracting eyelashes, stimulating by a massage of middle finger, third finger or big toe, as well as sear ing with a heated bamboo comb that is fine-toothed. Other than these, plantain and nightshade's nuts are used as drugs for it. Extracting eyelashes corresponds with exclusing suppurative node and draining the stye of pus ; and the use of plantain is based upon disinfection: and nightshade's nuts are said to be effective, however, their pharmacological action has no grounds. 6) For a treatment of toothache, such herb remedies are commonly employed as rinsing mouth with brine and holding cold water or gasoline in the mouth ; and as the drugs that are believed to be effective have been Welsh onion, ginger and castor-oil, plant, etc. The use of Welsh onion is based upon pain killing, antiinflammatory actions, and the use of ginger is based upon detoxication and disinfection ; and seeds of castor-oil plants are said to be effective, but they have no pharmacological basis. 7) When one has hives, such herb remedies are commonly applied as rubbing burned straw in affected parts, exposing to its smoke, rubbing with salt, sweeping down with a broom, and spreading and drinking boiled water of trifoliate orange. The use of cassia tora seeds, walnut, aloe and radish is said to be effective. The use of cassia tor a seeds has the functions of intestinal order, anti-paralysis, etc. The use of walnut has resulted in an increase of blood by invigorating spirits ; and the use of aloe is based upon disinfection, antibiotic, anti-salt, antihistamine and detoxication action. But, the effects of radish juice and straw's smoke have no pharmacological grounds. 8) When one gets a boil, such herb remedies are commonly used as applying a plaster, paste of flour mixed with yolk, soy sauce or honey, as well as spreading pounded elm tree. Other remedies that have been said to be effective are ; heating with mugwort, brine, wild rocambole, aloe, onion, squid's bone, etc. The use of mugwort is based upon pain killing, astringent antiinflammatory and tranquility. Wild rocambole is based upon the generation and maintenance functions of cell-joining textures ; elm tree upon antiphlogistic ; aloe upon fever removal and antiphlogistic ; onion on pain killing, fever removal, antiphlogistic and tranquility ; squid's bone on astriction: and brine or vinegar on sterilization. Pine resin and gardenia seed are said to be effective, but they have no pharmacological basis. 9) When one cuts his skin, such herb remedies are commonly employed as spreading mugwort's juice or squid's bone powder, or pressing the wounds. In addition, kalopanax, onion and fine soil are employed. The use of mugwort, kalopanax and squid's bone is based upon such functions as hemostasis, sedation, pain killing, antibacterial ; and fine soil is said to be effective, but it has no pharmacological basis. 10) When one suffers from whitlow, such herb remedies are commonly utilized as heating with boiled soy sauce, spreading soybean paste, or dipping into eggs, etc. Other drugs that have been employed are onion root, brine, eggplant, potato, loach, etc. The use of onion is based upon pain killing and antiphlogistic functions ; and that of brine upon antiphlogistic function. The use of soy sauce or soybean paste, fomentation, eggplant, potato and loach is said to be effective, but it has no pharmacblogic ground. 11) For the treatment of frostbite, such herb remedies are commonly used as dipping the affected part into frozen soybean sack, using boiled water of eggplant stem, garlic caulis, onion, hot pepper, caulis. Onion is based upon antiphlogistic and tranquility actions garlic upon disintection, metabolic exacerbation, tonic and aphrodisiac actions and the use of eggplant and hot pepper is based upon help blood circulation, dissolution and excretion of waste matters in vein. 12) For the treatment of burn, such herb remedies or drugs are commonly used as cleansing with Korean gin, spreading eggs, cleansing with cold water and soap water ; and as brine, cactus, moss, soybean paste, oil, etc. The cleansing with Korean gin, cold water, soap water, brine, vinegar is based upon cleaning and sterilizing functions ; and the use of cucumber is based upon nu. trition provision, and strengthening of resisting power by adjustment of metabolism. The use of potato, cactus, moss, oil and eggs is said to be effective, but their phamacological functions are not clarified. In view of the above results, we can realize that the drugs that have been employed in herb remedies are quite diverse. However, in regard to majority of herb remedies that have been employed by symptoms, the pharmacological functions of their drugs have not been clarified, and they are merely known as effective. Furthermore, they have not been recorded in the literature as yet ; and we confirm that there have been many herb remedies that were executed without the proper knowlege of their effects. It is now our view that the results of this survey may be utilized for consulting data in regard to the use of herb remedies.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

A Study on the Sasang Constitutional Distribution Among the People in the United States of America (북미지역주민(北美地域住民)의 사상체질(四象體質) 분포(分布)에 관(關)한 연구(硏究))

  • Koh, Byung-hee;Kim, Seon-ho;Park, Byung-gwan;Lavelle, Jonathan D;Tecun, Marianne;Anthony Jr., Ross;Hobbs, Ron;Zolli, Frank;Chin, Kyung-hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.11 no.2
    • /
    • pp.119-150
    • /
    • 1999
  • In spite of recent remarkable recent development in both western and oriental medical sciences, there is still only a shallow understanding of individual differences for various prognoses of incurable diseases and immunopathy diseases. Nevertheless, the care, cure and prevention methods of Sasang Constitutional Medicine are broadly used as an effective treatment of incurable diseases like immunopathy diseases and stress-related diseases and diseases due to aging. In this sense, the establishment of classification norms is urgent and essential for the worldwide application of Sasang Constitutional Medicine(SCM). This study began with the confirmation process of whether Sasang Constitutional types exist in Americans. To accomodate for cultural differences, the distinguishing tool was readjusted so that Sasang Constitutional Types in Americans could be determined. Hence, the selected tool is the new QSCCII+, which is a newly revised English version of the QSCCII. QSCCII was made and standardized by Dept. of SCM in Kyung Hee Medical Center and Dr. Kim7). The evaluation methods of the old version were improved in the new QSCCII+ through necessary statistical manipulation. The original QSCCII was officially authorized by the Korean Society of Sasang Constitutional Medicine as the only computerized version of Sasang diagnostics. This study is the first attempt to design a new diagnostic tool for the classification of Sasang Constitutional types in North Americans with the revision of QSCCII. The subjects of this study were selected from the cooperative people among the students and staffs of the University of Bridgeport and the patients who visited the Clinic in the Health Science Center. This study takes for about 1 year from 1998. 8 to 1999. 8 The conclusions of the study can be summarized as follows: 1. Sasang constitutional types also exist in Americans. It can also naturally be inferred that Sasang Constitutional types exist in all human beings, for there are many different human races in America. 2. There are more So-Yang In's than any other types in American white people. This result confirms the hypothesis that there also exist Sasang Constitutional types in westerners. 3. The result of repetitive tests suggests that the new QSCCII+ is an effective diagnostic tool for westerners when we consider the constant diagnostic results of the QSCCII+. 4. Sasang Constitutional types exit in the sample group regardless of racial difference. 5. The question items that were not often checked by Americans need to be modified into more understandable expressions. 6. The standardization of diagnosis for Americans should be established by use of the QSCCII+ 7. It can be guessed that there are many Tae-yang In's among the 71 persons who could not be clearly classified by the QSCCII+. Due to the scarcity of Tae-yang-In in general, it is important to improve upon the discernability of the QSCC II+. 8. The results of the Sasang Constitutional distribution in North Americans are as follows: The percentage of So-yang In distribution in the sample group is 36.25%(87persons), that of Tae-eum In is 13.75%(33persons), and that of So-eum In is 20.41%(49persons).

  • PDF

Relationship Between Usage Needs Satisfaction and Commitment to Apparel Brand Communities: Moderator Effect of Apparel Brand Image (의류 브랜드 커뮤니티의 이용욕구 충족과 커뮤니티 몰입의 관계: 의류 브랜드 이미지의 조절효과)

  • Hong, Hee-Sook;Ryu, Sung-Min;Moon, Chul-Woo
    • Journal of Global Scholars of Marketing Science
    • /
    • v.17 no.4
    • /
    • pp.51-89
    • /
    • 2007
  • INTRODUCTION Due to the high broadband internet penetration rate and its group-oriented culture, various types of online communities operate in Korea. This study use 'Uses and Gratification Approach, and argue that members' usage-needs satisfaction with brand community is an important factor for promoting community commitment. Based on previous studies identifying the effect of brand image on consumers' responses to various marketing stimuli, this study hypothesizes that brand image can be a moderate variable affecting the relationship between usage-needs satisfaction with brand community and members' commitment to brand community. This study analyzes the influence of usage-needs satisfaction on brand community commitment and how apparel brand image affects the relationships between usage-needs satisfactions and community commitments. The hypotheses of this study are proposed as follows. H1-3: The usage-needs satisfaction of apparel brand community (interest, transaction, relationship needs) influences emotional (H1), continuous (H2), and normative (H3) commitments to apparel brand communities. H4-6: Apparel brand image has a moderating effect on the relationship between usage-needs satisfaction and emotional (H4), continuous (H5), and normative (H6) commitments to apparel brand communities. METHODS Brand communities founded by non-company affiliates were excluded and emphasis was placed instead on communities created by apparel brand companies. Among casual apparel brands registered in 6 Korean portal sites in August 2003, a total of 9 casual apparel brand online communities were chosen, depending on the level of community activity and apparel brand image. Data from 317 community members were analyzed by exploratory factor analysis, moderated regression analysis, ANOVA, and scheffe test. Among 317 respondents answered an online html-type questionnaire, 80.5% were between 16 to 25 years old. There were a total of 150 respondents from apparel brand communities(n=3) recording higher-than-average brand image scores (Mean > 3.75) and a total of 162 respondents from apparel brand communities(n=6) recording lower-than-average brand image scores(Mean < 3.75). In this study, brand community commitment was measured by a 5-point Likert scale: emotional, continuous and normative commitment. The degree of usage-needs satisfaction (interest, transaction, relationship needs) was measured on a 5-point Likert scale. The level of brand image was measured by a 5-point Likert scale: strength, favorability, and uniqueness of brand associations. RESULTS In the results of exploratory factor analysis, the three usage-needs satisfactions with brand community were classified as interest, transaction, and relationship needs. Brand community commitment was also divided into the multi-dimensional factors: emotional, continuous, and normative commitments. The regression analysis (using a stepwise method) was used to test the influence of 3 independent variables (interest-needs satisfaction, transaction-needs, and relationship-needs satisfactions) on the 3 dependent variables (emotional, continuous and normative commitments). The three types of usage-needs satisfactions are positively associated with the three types of commitments to apparel brand communities. Therefore, hypothesis 1, 2, and 3 were significantly supported. Moderating effects of apparel brand image on the relationship between usage-needs satisfaction and brand community commitments were tested by moderated regression analysis. The statistics result showed that the influence of transaction-needs on emotional commitment was significantly moderated by apparel brand image. In addition, apparel brand image had moderating effects on the relationship between relationship-needs satisfaction and emotional, continuous and normative commitments to apparel brand communities. However, there were not significant moderate effects of apparel brand image on the relationships between interest-needs satisfaction and 3 types of commitments (emotional, continuous and normative commitments) to apparel brand communities. In addition, the influences of transaction-needs satisfaction on 2 types of commitments (continuous and normative commitments) were not significantly moderated by apparel brand image. Therefore, hypothesis 4, 5 and 6 were partially supported. To explain the moderating effects of apparel brand image, four cross-tabulated groups were made by averages of usage-needs satisfaction (interest-needs satisfaction avg. M=3.09, transaction-needs satisfaction avg. M=3.46, relationship-needs satisfaction M=1.62) and the average apparel brand image (M=3.75). The average scores of commitments in each classified group are presented in Tables and Figures. There were significant differences among four groups. As can be seen from the results of scheffe test on the tables, emotional commitment in community group with high brand image was higher than one in community group with low brand image when transaction-needs satisfaction was high. However, when transaction-needs satisfaction was low, there was not any difference between the community group with high brand image and community group with low brand image regarding emotional commitment to apparel brand communities. It means that emotional commitment didn't increase significantly without high satisfaction of transaction-needs, despite the high apparel brand image. In addition, when apparel brand image was low, increase in transaction-needs did not lead to the increase in emotional commitment. Therefore, the significant relationship between transaction-needs satisfaction and emotional commitment was found in only brand communities with high apparel brand image, and the moderating effect of apparel brand image on this relationship between two variables was found in the communities with high satisfaction of transaction-needs only. Statistics results showed that the level of emotional commitment is related to the satisfaction level of transaction-needs, while overall response is related to the level of apparel brand image. We also found that the role of apparel brand image as a moderating factor was limited by the level of transaction-needs satisfaction. In addition, relationship-needs satisfaction brought significant increase in emotional commitment in both community groups (high and low levels of brand image), and the effect of apparel brand image on emotional commitment was significant in both community groups (high and low levels of relationship-needs satisfaction). Especially, the effect of brand image was greater when the level of relationship-needs satisfaction was high. in contrast, increase in emotional commitment responding to increase in relationship-needs satisfaction was greater when apparel brand image is high. The significant influences of relationship-needs satisfaction on community commitments (continuous and normative commitments) were found regardless of apparel brand image(in both community groups with low and high brand image). However, the effects of apparel brand image on continuous and normative commitments were found in only community group with high satisfaction level of relationship-needs. In the case of communities with low satisfaction levels of relationship needs, apparel brand image marginally increases continuous and normative commitments. Therefore, we could not find the moderating effect of apparel brand image on the relationship between relationship-needs satisfaction and continuous and normative commitments in community groups with low satisfaction levels of relationship needs, CONCLUSIONS AND IMPLICATIONS From the results of this study, we draw several conclusions; First, the increases in usage-needs satisfactions through apparel brand communities result in the increases in commitments to apparel brand communities, wheres the degrees of such relationship depends on the level of apparel brand image. That is, apparel brand image is a moderating factor strengthening the relationship between usage-needs satisfaction and commitment to apparel brand communities. In addition, the effect of apparel brand image differs, depending on the level and types of community usage-needs satisfactions. Therefore, marketers of apparel brand companies must determine the appropriate usage-needs, depending on the type of commitment they wish to increase and the level of their apparel brand image, to promote member's commitments to apparel brand communities. Especially, relationship-needs satisfaction was very important factor for increasing emotional, continuous and normative commitments to communities. However the level of relationship-needs satisfaction was lower than interest-needs and transaction-needs. satisfaction. According to previous study on apparel brand communities, relationship-need satisfaction was strongly related to member's intention of participation in their communities. Therefore, marketers need to develope various strategies in order to increase the relationship- needs as well as interest and transaction needs. In addition, despite continuous commitment was higher than emotional and normative commitments, all types of commitments to apparel brand communities had scores lower than 3.0 that was mid point in 5-point scale. A Korean study reported that the level of members' commitment to apparel brand community influenced customers' identification with a brand and brand purchasing behavior. Therefore, marketers should try to increase members' usage-needs satisfaction and apparel brand image as the necessary conditions for bringing about community commitments. Second, marketers should understand that they should keep in mind that increasing the level of community usage needs (transaction and relationship) is most effective in raising commitment when the level of apparel brand image is high, and that increasing usage needs (transaction needs) satisfaction in communities with low brand image might not be as effective as anticipated. Therefore, apparel companies with desirable brand image such as luxury designer goods firms need to create formal online brand communities (as opposed to informal communities with rudimentary online contents) to satisfy transaction and relationship needs systematically. It will create brand equity through consumers' increased emotional, continuous and normative commitments. Even though apparel brand is very famous, emotional commitment to apparel brand communities cannot be easily increased without transaction-needs satisfaction. Therefore famous fashion brand companies should focus on developing various marketing strategies to increase transaction-needs satisfaction.

  • PDF

The Biochemical Studies on Stored Soy-sauce (저장(貯藏)간장의 생화학적(生化學的) 연구(硏究))

  • Chang, Chi-Hyun
    • Applied Biological Chemistry
    • /
    • v.9
    • /
    • pp.9-27
    • /
    • 1968
  • Studies were carried out in order to elucidate chemical components and microflora in three types of soy-sauce, 12-year aged soy-sauce prepared by improved method. 7-year aged and 20-year aged soy-sauce prepared by ordinary method. They results are summarized as follows: 1. The followings are found to be the important factors affecting the quality of soy sauce. a. Organic acids, reducing sugars and free amino acids were increased in the course of storage. b. In the aged soy-sauces under study non-volatile organic acid increased while volatile organic acid decreased and the total acidity was dependent only upon tie latter. c. It was found that suit concentration decreased during the storage. 2. The results of investigation of microflora in the stored soy-sauce are shown as follows. Soy-sauce Improved Ordinary Microbe 12-Y. 20-Y. 7-Y. Aerobic bacteria colony/1ml. 6 123 2 Halophilic lactic acid bacteria colony/1ml. 4 6 10 Osmophilic yeast colony/1ml. $828{\times}10^4$ 248 - b. In the stored soy-sauces, aerobic bacteria are incapable of growing due to drop in pH value and the influence of salt concentration. c. Halophilic lactic acid bacteria are incapable of growing due to drop in pH value, even the salt concentrations decreased during the storage. d. Osmophilic yeast are still growing in low pH value and in the decreasing salt concentration during the strage. 3. The results of amino acid analysis by paper partition chromatographic and calorimetric methods are shown as follows. a. Fourteen kinds of amino acid and thirteen amino acids were detected in the soy-sauce of 12-year aged improved soy-sauce and 7-year aged and 20-year aged ordinary one, respectively. b. The contents of aspartic acid, glutamic acid, serine, valine, leucine, lysine, histidine and methionine increased in the 20-year aged ordinary soy-sauce compared to the 7-year aged one. On the other hand those of alanine, tyrosine, phenylalanine and cystine decreased. 4. The results of sugar analysis by paper chromatography are as follows. a. In the 12-year aged improved soy-sauce, galactose, glucose, arabinose, xylose, rhamnose, maltose and an unknown were detected, and their amounts were in the above order except maltose and an unknown. b. Both in the 7 and 12-year aged ordinary soy-sauces, galactose, arabinose, xylose, glucose and rhamnose were detected and the amounts of the sugars were in the above order. c. In the non-aged ordinary soy-sauce, glucose was not detected but detected from 7-year and 20-year aged ordinary soy-sauce. 5. The results of organic acid analysis by paper chromatography were as follows. a. As volatile acids, acetic, propionic and butyric acids were detected in the 7-year aged ordinary soy-sauce. On the other hand in both the 20-year aged ordinary soy-sauce and the 12-year aged improved ones, only acetic acid was abundant while propionic and butyric acids were round in trace. It was found that propionic and butyric acids, as the unpleasant flavor components, decreased during the storage. b. In the ordinary soy-sauce, citric acid were produced during the storage and lack, malic and tartaric acids increased in the course of aging while succinic, glycolic, fumaric and malonic acids were shown to decrease. Glutaric and oxalic acids disappeared. Citric acid was produced also in the improved soy-sauce, but lactic, tartaric, succinic, malic, and glycolic acids decreased, while both malonic and glutaric acids disappeared. From the above results the citric acid production was considered to be a favorable factor for the taste. c. In the aged soy-sauces, pyruvic, α-ketoglutaric and probably acetoacetic and oxaloacetic acids (both in trace) were present and their amounts were in the above order. All of the α-keto acid abruptly decreased during the storage.

  • PDF