• Title/Summary/Keyword: 2-D Wedge

Search Result 121, Processing Time 0.027 seconds

Cell Wall Deterioration of the Tripitaka Koreana Wooden Plates (팔만대장경판의 세포벽 열화)

  • Park, So-Yoon;Kang, Ae-Kyung;Park, Sang-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.55-60
    • /
    • 1996
  • Tripitaka Koreana were made during Coryo Dynasty from 1236 to 1251 A.D. Buddhist scriptures were engraved on 81.340 wooden plates. Some plates were varnished with Rhus lacquer, but most of them were uncoated. Macroscopically, most of the plates appeared intact due to the storage in a well-ventilated wooden house. Because, they were irregularly used for printings with ink, it can be assumed that they were repeatedly exposed to ink-water and drying processes. The present were made to examine the changes of wood cell structures occurred during long-term aging deterioration processes in these dry archaeological wooden plates. Light, scanning and transmission electron microscopes were employed for this study. Wedge-shaped cracks and delamilations were found from the lumen side toward the compound middle lamellae and they progressed toward primary or secondary walls. A large amount of hypae in vessels and the degradation of vessel-ray pit walls by the fungal hyphae were observed. When compared to the recent wood, the birefringence of wood fibers was considerably lower or completly disappeared, suggesting the degradation of crystalline cellulose in these wood samples. The degradation of the cell wall could be also revealed the calculation of crystallinity with X-ray diffraction and the size of crystalline region was estimated.

  • PDF

A Geometric Derivation of the Craig Representation for the Two-Dimensional Gaussian Q-Function (이변량 가우시안 Q-함수의 Craig 표현에 대한 기하학적인 유도)

  • Park, Seung-Keun;Lee, Il-Kyoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.4A
    • /
    • pp.325-328
    • /
    • 2011
  • In this paper, we present a new and simple derivation of the Craig representation for the two-dimensional (2-D) Gaussian Q-function in the viewpoint of geometry. The geometric derivation also leads to an alternative Craig form for the 2-D Gaussian Q-function. The derived Craig form is newly obtained from the geometry of two wedge-shaped regions generated by the rotation of Cartesian coordinates over two correlated Gaussian noises. The presented Craig form can play a important role in computing the probability represented by the 2-D Gaussian Q-function.

Study on 3D Printer Producing of Assistive Devices for Vertical Incidence of Law Method (Law법 수직입사를 위한 보조기구의 3D 프린터 제작 연구)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.489-494
    • /
    • 2020
  • The Law method is observing the temporal bone. There are two types of methods: the double angle method, which manipulates the center ray angle of the tube twice, and the single angle method, which manipulates once. The purpose is to increase the reproducibility of the image by making vertical incidence by making an assistive device using a 3D printer. Two assistive devices with a wedge-shaped 8.5 × 10 × 2.3 cm, an inclined surface of 7.5 cm, and an inclination angle of 15° were fabricated. Assistive devices can be combined with each other in the form of grooves, and PLA (Poly Lactic Acid) is used as a material. In the first experiment, 10 examiners operated the tube 15° in the caudad direction and 15° in the anterior direction, and measured it with a protractor to conduct a reproducibility experiment. Second, two examiners acquired vertically incidence images using the existing law method and assistive devices, and measured the distance between each measurement point to evaluate the reproducibility. The tube center ray angle reproducibility experiment was not statistically significant, but the angle difference was up to 9° between examiners. The reproducibility experiment of radiographic images was not statistically significant with the conventional method, and the method using an assistive device was statistically significant. Therefore, regardless of skill level, an image capable of securing reproducibility, which is the advantage of vertical incidence, could be obtained.

A Study of a Non-commercial 3D Planning System, Plunc for Clinical Applicability (비 상업용 3차원 치료계획시스템인 Plunc의 임상적용 가능성에 대한 연구)

  • Cho, Byung-Chul;Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.16 no.1
    • /
    • pp.71-79
    • /
    • 1998
  • Purpose : The objective of this study is to introduce our installation of a non-commercial 3D Planning system, Plunc and confirm it's clinical applicability in various treatment situations. Materials and Methods : We obtained source codes of Plunc, offered by University of North Carolina and installed them on a Pentium Pro 200MHz (128MB RAM, Millenium VGA) with Linux operating system. To examine accuracy of dose distributions calculated by Plunc, we input beam data of 6MV Photon of our linear accelerator(Siemens MXE 6740) including tissue-maximum ratio, scatter-maximum ratio, attenuation coefficients and shapes of wedge filters. After then, we compared values of dose distributions(Percent depth dose; PDD, dose profiles with and without wedge filters, oblique incident beam, and dose distributions under air-gap) calculated by Plunc with measured values. Results : Plunc operated in almost real time except spending about 10 seconds in full volume dose distribution and dose-volume histogram(DVH) on the PC described above. As compared with measurements for irradiations of 90-cm 550 and 10-cm depth isocenter, the PDD curves calculated by Plunc did not exceed $1\%$ of inaccuracies except buildup region. For dose profiles with and without wedge filter, the calculated ones are accurate within $2\%$ except low-dose region outside irradiations where Plunc showed $5\%$ of dose reduction. For the oblique incident beam, it showed a good agreement except low dose region below $30\%$ of isocenter dose. In the case of dose distribution under air-gap, there was $5\%$ errors of the central-axis dose. Conclusion : By comparing photon dose calculations using the Plunc with measurements, we confirmed that Plunc showed acceptable accuracies about $2-5\%$ in typical treatment situations which was comparable to commercial planning systems using correction-based a1gorithms. Plunc does not have a function for electron beam planning up to the present. However, it is possible to implement electron dose calculation modules or more accurate photon dose calculation into the Plunc system. Plunc is shown to be useful to clear many limitations of 2D planning systems in clinics where a commercial 3D planning system is not available.

  • PDF

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS (수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가)

  • Lee, Eun-Hye;Choi, Hang-Moon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.188-197
    • /
    • 2010
  • The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of $10{\times}10$ pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.

Analysis of Rock Slope Stability for Natural Slope and Cut Slope of Gneiss Area in Andong, Korea (편마암지역 자연사면.절취사면의 안정성 분석 사례)

  • Kim, Man-Il;Bae, Du-Won;Kim, Jong-Tae;Chae, Byung-Gon;Jeong, Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.17 no.2 s.52
    • /
    • pp.289-297
    • /
    • 2007
  • Slope failure that is occurred by rainfall generates a lot of property damages and loss of lives. Slope stability management and reinforcement countermeasure can be attained through continuous monitoring about various slope types that adjoin in human's life for reducing slope failure from natural and artificial cut slope hazards. The study area is rock slope that is consisted of gneiss, and large scale joint set is ranging by fault activity. This rock mass is exposed during long period and has lithological weathering property of weathered rock or soft rock. In-situ investigation carried out after divide by natural slope and cut slope. As a result, the natural slope appeared to high possibility of planar failure and wedge failure in few joint points that main joint set is formed. On the other hand, slope failure conformation in cut slope was superior only wedge failure occurrence possibility in eight joint points. In result of numerical analysis using SLIDE 2D, the minimum safety factor was analyzed slope stability for cut slope relatively low than natural slope in this study.

Feasibility of 3D Dipole-Dipole Electrical Resistivity Method to a Vein-Type Ore Deposit (국내 맥상광체조사를 위한 3차원 쌍극자-쌍극자 전기비저항 탐사의 적용성 분석)

  • Min, Dong-Joo;Jung, Hyun-Key;Lee, Hyo-Sun;Park, Sam-Gyu;Lee, Ho-Yong
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.3
    • /
    • pp.268-277
    • /
    • 2009
  • Recently as the interest in the development of domestic ore deposits has increased, we can easily find some studies on exploration geophysics-based ore deposit survey in literature. Geophysical surveys have been applied to the investigation of both metallic and non-metallic ore deposit. For metallic ore-deposit survey, the 2D electrical resistivity method has been popularly used, because metallic mineral deposits are generally more conductive than surrounding media. However, geological structures are 3D rather than 2D structures, which may lead to misinterpretation in 2D inversion section. In this study, 3D effects are examined for several 3D structures such as a width-varying dyke model and a wedge-shaped model. We also investigate the effects of the direction of survey line. Numerical results show that the width-varying dyke model yields some low resistivity zone in the deep part, which is independent of real ore-body location. For the wedge-shaped model, even though the survey line is located apart from the ore body, the 2D inversion section still shows low resistivity zone in the deep part. When the survey line is not perpendicular to the strike of the ore body, the low resistivity zone is slightly broader but shallower than that obtained along the survey line perpendicular to the strike. For the survey lines that have an angle smaller than $45^{\circ}$ with the strike of the ore body, the inversion results are totally distorted. From these results, we conclude that 2-D survey and interpretation can lead to misinterpretation of subsurface structures, which may be linked to economical loss. Eventually, we recommend to apply 3-D rather than 2-D electrical resistivity survey for ore-deposit survey.

Current Status of Clinical Practice for Gastric Cancer Patients in Korea -A Nationwide Survey- (전국 위암 환자 진료 현황에 관한 설문조사 결과)

  • ;Yang Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.4 no.2
    • /
    • pp.95-108
    • /
    • 2004
  • This nationwide survey was conducted to evaluate the current status of clinical practice for gastric cancer patients in Korea. The Information Committee of the Korean Gastric Cancer Association (KGCA) sent questionnaires containing 45 items about the preoperative diagnosis, medical and surgical treatment, and postoperative follow-up for gastric cancer patients to all 298 KGCA members in 108 institutes. Response rates were $32.6\%$ (97/298) for individuals and $59.3\%$ (64/108) for institutes. Most university hospitals responded (response rate of university hospitals: $71.6\%$, 48/67). The preoperative staging work up was performed primarily by abdominal CT, followed by bone scans, abdominal ultrasound, endoscopic ultrasound, and so on. Gastric cancer patients with stages II, III, and IV usually received adjuvant chemotherapy after a curative operation. About half of the surgeons regarded 2 cm as a safe resection margin in early gastric cancer and 5 cm in advanced gastric cancer. More than half of surgeons usually performed a D2 lymph node dissection in early gastric cancer and D2+$\alpha$ lymph node dissection in advanced gastric cancer. About $20\%$ of surgeons performed less invasive surgery and/or function-preserving surgery, such as a pylorus-preserving gastrectomy, a laparoscopic wedge resection, or a laparoscopy-assisted distal gastrectomy.

  • PDF

Evaluation of Application of 3D Printing Phantom According to Manufacturing Method (구성 물질에 따른 3D 프린팅 팬텀의 적용 평가)

  • Young Sang Kim;Ju Young Lee;Hoon Hee Park
    • Journal of Radiation Industry
    • /
    • v.17 no.2
    • /
    • pp.173-181
    • /
    • 2023
  • 3D printing is a technology that can transform and process computerized data obtained through modeling or 3D scanning via CAD. In the medical field, studies on customized 3D printing technology for clinical use or patients and diseases continue. The importance of research on filaments and molding methods is increasing, but research on manufacturing methods and available raw materials is not being actively conducted. In this study, we compare the characteristics of each material according to the manufacturing method of the phantom manufactured with 3D printing technology and evaluate its usefulness. We manufactured phantoms of the same size using poly methyl meta acrylate (PMMA), acrylonitrile butadiene styrene (ABS), and Poly Lactic Acid (PLA) based on the international standard phantom of aluminum step wedge. We used SITEC's radiation generator (DigiRAD-FPC R-1000-150) and compared the shielding rate and line attenuation coefficient through the average after shooting 10 times. As a result, in the case of the measured dose transmitted through each phantom, it was confirmed that the appearance of the dose measured for phantoms decreased linearly as the thickness increased under each condition. The sensitivity also decreased as the steps increased for each phantom and confirmed that it was different depending on the thickness and material. Through this study, we confirmed that 3D printing technology can be usefully used for phantom production in the medical field. If further development of printing technology and studies on various materials are conducted, it is believed that they will contribute to the development of the medical research environment.