• Title/Summary/Keyword: 2차 공기 주입 조건

Search Result 13, Processing Time 0.024 seconds

Experimental Study on Thermal NOx and CO Emission in a Laboratory-Scale Incinerator with Reversed Secondary Air Jet Injection (역방향 2차 공기 주입 방식을 적용한 소각 연소로의 Thermal NOx 및 CO 배출특성에 대한 축소모형실험 연구)

  • Choi, Chonggun;Choi, Woosung;Shin, Donghoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.8
    • /
    • pp.503-510
    • /
    • 2016
  • Incinerators generally emit pollutants such as NOx and CO during the combustion process. In this paper, pollutant emissions and temperature distributions were studied in a simulated incinerator with a reversed (relative to the flue gas flow) secondary air injection system. The experiments were performed by using a lab-scale furnace in order to evaluate the effects of the injection location, direction and flow rate of secondary air jets. The emission of NOx was lower in the case of reversed secondary air injection than in the case of cross injection, due to the recirculation and mixing of the exhaust gas. In the reversed air injection cases, thermal NOx emissions decreased as secondary air ratio increased from 30 to 60 and slightly increased at secondary air ratios higher than 60. In most cases, CO emissions were not detected except for a few reversed secondary air injection cases, in which cases CO concentrations below 2ppm were observed.

Analysis of the Gas Flow Field of Primary Combustion Chamber with the Conditions of Secondary Air Injection (2차 공기 주입 조건 변화에 따른 소형 소각로 내부의 유동장 분석)

  • Choi, Byung-Dae;Kim, Sung-Joon
    • Journal of Industrial Technology
    • /
    • v.22 no.A
    • /
    • pp.9-17
    • /
    • 2002
  • This analysis is aimed to find out how the conditions of secondary air injection affects the residence time and the turbulence energy of flue gas and flow field in a small incinerator. A commercial code, PHOENICS, is used to simulate the flow field of an Incinerator. The computational grid system is constructed in a cartesian coordinate system In this numerical experiment, an independent numerical variable is the conditions of secondary air injection and dependants are the residence time of flue gas and the mean value of turbulence energy in a primary combustion chamber. The flow field and the distribution of turbulence energy are analysed to evaluate the residence time of flue gas and the turbulence energy The computational results say that the tangential injection of secondary air make the residence time much longer than the radial injection and that the radial injection of secondary make turbulence much stronger than the tangential injection.

  • PDF

Enhancement of combustion efficiency of a air-cooled combustor system with single F.D. Fan Using CFD (전산유체역학을 이용한 단일 송풍기가 적용된 공냉식 연소설비의 효율개선)

  • Kim, Min-Choul;Shon, Byung-Hyun;Lee, Jae-Jeong;Park, Hung-Suck
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.460-468
    • /
    • 2021
  • This study investigated the enhanced combustion efficiency of an "air-cooled combustion system" with single F.D. fan, and performed a numerical analysis for the operation and design conditions to increase the combustion efficiency. The combustion efficiency in an actual combustor was compared before and after the structure modification. Numerical analysis for application of a single fan revealed the difficulty of forming a turbulence for circular combustion conditions. This is because the supply ratio of combustion air supplied into 2 flow paths becomes irregular in the combustion furnace due to a change in friction force and pressure in each flow path. Subsequently, two methods of supplying air into the combustion furnace were analyzed numerically to obtain the optimal combustion conditions of an air-cooled combustion system. The first method involved injecting the preheated combustion air after a 180~360 degree rotation from the outer wall, whereas in the second method, the combustion air was injected into the combustion furnace in a tangential direction after primary heat exchange outside the combustion furnace, by applying a rotatable vane structure in the combustion furnace. Results reveal that application of a single F.D. fan to the air injection into a rotatable combustion furnace is desirable for optimization of the combustion conditions for applying a duct structure having a dual cooling wall for the cooling of the outer wall of the combustion furnace, and for maintaining perfect mixing in the combustion furnace. We therefore confirmed enhanced combustion efficiency by comparing the actual combustion efficiency before and after structure modification.

Analysis of Heat Transmission Characteristics through Air-Inflated Double Layer Film by Using Thermal Resistance Equation (열저항식을 이용한 공기막 이중필름의 관류전열량 특성 분석)

  • Kim, Hyung-Kweon;Jeon, Jong-Gil;Paek, Yee;Lee, Sang-Ho;Yun, Nam-Kyu;Yoo, Ju-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.22 no.4
    • /
    • pp.316-321
    • /
    • 2013
  • This study was carried out to analyze heat transfer characteristics and heat flow through air-inflated double layer PO film with thermal resistance method. The experiments was conducted in the laboratory controlled air temperature between 258.0 K and 278.0 K. The experimental materials were made up two layers PO film and an inflated-air layer. The thickness of air-inflated layer was fixed at 3 types of 110, 175, 225 mm. The electrical circuit analogy for heat transfer by conduction, radiation and convection was introduced. Experimental data shows that the dominant thermal resistance in heat transfer through the air-inflated double layer film was convection. Calculation errors were 1.1~18.5 W for heat flow. In result, the method of thermal resistance could be introduced for analysis of heat flow characteristics through air-inflated double layer film.

SCR facility design for the selective catalyst performance of mixed gas

  • Woohyeon, Hwang;Kyung-Ok, Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.1
    • /
    • pp.121-127
    • /
    • 2023
  • In this study, the design conditions and CFD analysis results are compared and reviewed in SCR that can optimally reduce nitrogen compounds. To this end, it was analyzed and compared using CFD to see if the design criteria were satisfied for the shell and tube areas of the boiler. In the SCR system, the analysis area is the gas/air heat exchanger on the shell side, and eight tubes of the gas/air heat exchanger on the tube side. Through CFD analysis, the gas velocity distribution on the primary catalyst side of the SCR system was designed to be 2.4%, and the NH3/NOx molar ratio distribution was 3.7%, which satisfied the design criteria. In addition, the uniformity of the temperature distribution was confirmed and the required condition of 260℃ or higher was satisfied. The angle of the gas entering the catalyst met the design conditions at 2.9 degrees, and the pressure loss that occurred also satisfied the design requirements. Through this CFD analysis, it was confirmed that it was designed and operated by satisfying the design conditions required for each area.

Study on Computational Fluid Dynamics(CFD) Simulation for De-NOx in the incinerator at Taebaek city (태백시 소각로 내 NOx 제거를 위한 전산유체역학(CFD) simulation 연구)

  • Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.320-332
    • /
    • 2013
  • The feed air to MSW incinerator influences on the residence time of combustion gas, removal of unburnt ash and exiting gas temperature. Thus the secondary air volume could present sufficient residence time which can maintain the exiting temperature over $850^{\circ}C$. The secondary air also relates directly with the turbulence in the inside of combustion chamber, which finally provide the stable combustion condition. The present study designed a modern incinerator for a field scale, and evaluation of the potential amount of primary air based on the daily combustible quantity. From the evaluated primary air volume, the secondary air flow rate could be estimated, and its dynamic behavior was verified. In addition, the obtained air volume enables to find an optimum operation condition of the combustion. As a result of the CFD simulation, the air ratio 75 : 25 between primary and secondary air amount was optimum ratio than design criteria 72 : 28. And the flow velocity ratio of front-back of secondary air jet nozzle was found excellent at 1 : 3. In addition, the result of applied to the plant, the removal efficiency of NOx and CO generation would concentration of CO.

Studies on Oxidation Modification of Polyethylene Wax (폴리에틸렌 왁스의 산화변성에 관한 연구)

  • Choi, Byung-Ryul;Park, Yang-Jun
    • Applied Chemistry for Engineering
    • /
    • v.8 no.5
    • /
    • pp.837-843
    • /
    • 1997
  • In oxidized polyethylene wax preparation, the effects of main parameters such as the property of used wax, oxidation time, oxidation temperature, air feed rates on the change of acid-numbers were investigated. The change in polymer property was also investigated. The results showed under given reaction conditions, the acid numbers with oxidation temperature increased upto $160^{\circ}C$, but at higher temperature, it decreased. The base resin which was lower molecular weight had higher acid number. The result showed molecular weight as a experimental parameter was more effective than density in oxidation experiment. In milder condition, free radical initiator was used for catalyst to get higher acid-numbers, which was successful in comparison to the non-catalyst system. Also the catalyst with longer half-life was efficient, in order of DCPO, HOPO and BPO.

  • PDF

A Study of Staged Swirling Combustion of Natural gas (천연가스 다단연소기술 연구)

  • 이진홍;목영일
    • Journal of Energy Engineering
    • /
    • v.4 no.1
    • /
    • pp.115-125
    • /
    • 1995
  • 본“천연가스 다단연소기술 연구”는, 공업적으로 널리 쓰이는 선회확산 방식으로 천연가스를 연소시킬 때 그 연소 특성과 발생되는 환경오염물질인 일산화탄소(CO)와 질소산화물(NOX)의 저감에 대한 연구로서, 천연가스의 난류확산화염과 선회확산화염의 유동장, 온도장, 농도장을 실험과 수치해석을 통하여 분석하여 각각 연소방식의 화염구조와 특성을 규명하고 해석하였다. 그리고 그 결과를 토대로하여 다단확산 연소실험 장치를 제작 다단확산연소의 중요한 인자인 1차당량비, 2차공기주입위치, 유속, 선회도 등을 변화시켜 질소산화물 저감과 높은 연소효율을 얻을 수 있는 최적의 연소조건을 찾아 내었다. 본고에서는 실험부분만을 간추려 발표하고 수치해석 부분은 다음 기회로 미루고자 한다.

  • PDF

Changes of Physico-chemical Characteristic on Swine Manure Using Different Suction Strength in Composting System (돈분 퇴비화 시 공기 흡입 강도에 따른 이화학적 특성변화)

  • Lee, Dong-Jun;Kim, Jung Kon;Jeong, Kwang-Hwa;Kawg, Jung-Hoon;Ravindran, B.;Lee, Ji-Woong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.25 no.2
    • /
    • pp.59-67
    • /
    • 2017
  • The aim of this experiment was to investigate the effect of air suction rate (SR) during the composting process of swine manure mixed with sawdust used as a bulking agent. In the 25 L composting reactors, the suction rate (SR) was at four different treatment levels (100%, 200%, 300%, 400%), and were fixed on the based on constant aeration rate into the composting mixtures. The temperature reached to thermophilic phase within 2 days and it was maintained up to the $5^{th}$ day of the composting process in all reactors and then gradually decreased to room temperature at the end of the composting process. The moisture content (MC, %) of the initial mixtures was 64.27%, and it was reduced to 38.4, 33.08, 14.59 and 11.93 in the different suction rate of 100%, 200%, 300%, 400%, respectively in the end process. During the composting, the level of pH was increased from 6.83 to 8.67 and it gradually decreased to 7.56 in 100% and 200%(SR). At the same time, the pH values were reduced only up to 8.19 at 300%, and 8.08 at 400%(SR), showing that suction strengths of 100% and 200% were the better option for composting than those of 300% and 400%. The total Kjeldahl nitrogen (TKN) of initial composts mixtures was 2.3% and were changed in 3.3, 3.1, 2.5, and 2.3% at the end of the composting period from the 100%-400% (SR) variations respectively. These results also indicated that 100% and 200% (SR) were more affected by the dry mass loss as $CO_2$ and water evaporation. The initial value of C/N ratio was 25.17 and were significantly reduced to 11.88, 11.97, 14.31, and 14.72 at the end of the experiment, respectively from the 100%-400% (SR) variations. These results suggest that the suction rate (SR) of 100% and 200% relative to constant air supply would be the optimal conditions to produce high-quality compost.

A Basic Study on Composting of Organic Household Waste using Small Vessels (소형 퇴비화 용기를 이용한 유기성 주방폐기물의 퇴비화에 관한 기초연구)

  • Song, Jun-Sang;Choi, Hun-Keun;Kim, Kyu-Yeon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.1 no.2
    • /
    • pp.227-235
    • /
    • 1993
  • This study was carried out to evaluate the possibility of composting for organic solid waste from restaurants and domestics. Small three vessels were prepared which were conditioned to semianaerobic, convectional and air-blowed type. During the experiment period for 4 months, the values of volatile solid(VS) %, moisture % and carbon/nitrogen (C/N) ratio of the wastes in the vessels were stabilized, 80 % to 40-50 %, 80 % to 48-55 % and 18 to 8-10, respectively. On the basis of VS % and C/N ratio, the reactions were more adaptable to 2nd order formula than to 1st order one, Reaction rate constant of the 3 vessels were estimated, $4.96{\times}10^{-5}(day^{-1})$ in the semianaerobic type, $5.82{\times}10^{-5}(day^{-1})$ in the convectional type and $8.42{\times}10^{-5}(day^{-1})$ in the air-blowed type on VS. Compared reaction rate constants(k), it can be said that composting period shorten if air is supplied artificially and that vessels simular to those of this study are useful for household organic waste at the backyards.

  • PDF