• Title/Summary/Keyword: 2차미분스펙트럼

Search Result 24, Processing Time 0.024 seconds

Determination of Degree of Retrogradation of Cooked Rice by Near-Infrared Reflectance Spectroscopy (근적외 분광분석법에 의한 밥의 노화도측정)

  • Cho, Seung-Yong;Choi, Sung-Gil;Rhee, Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.579-584
    • /
    • 1994
  • Near infrared reflectance(NIR) spectroscopy was used to determine the degree of retrogradation of cooked rice. Cooked rice samples were stored at $4^{\circ}C$ for 120 hours, and the degree of retrogradation was measured at every 6 hour during the storage time. Stored cooked rices were freeze-dried, milled and passed through a 100 mesh sieve. Enzymatic method using glucoamylase was used as reference method for the determination of the degree of retrogradation. Spectral differences due to retrogradation of cooked rice were observed at 1434, 1700, 1928, 2100, 2284 and 2320 nm. 32 samples of which moisture content were below 5% were used for calibration set, and 16 samples were used for validation set. High correlations were achieved between degree of retrogradation determined by conventional enzymatic method and by NIR with multiple correlation coefficient of 0.9753, and a standard error of calibration(SEC) of 3.64%. Comparable results were obtained with 3.91% of standard error of prediction(SEP), when the calibration equation was applied to independent group of samples of which moisture contents were in the range of calibration set. But when the calibration equation was applied to samples of which moisture contents were outer range of calibration set, SEP and bias were increased and correlation coefficient was decreased. The determination of degree of retrogradation was affected by sample moisture content. To determine degree of retrogradation of cooked rice by NIR using this calibration equation, it was suggested that sample moisture content should be controlled to below 5%.

  • PDF

The Technology for On-line Measurement of Coal Properties by using Near-Infrared (근적외선을 이용한 온라인 석탄 성상분석 방법)

  • Kim, Dong-Won;Lee, Jong-Min;Kim, Jae-Sung;Kim, Hak-Jong
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.596-603
    • /
    • 2007
  • Rapid or on-line coal analysis is of great interest in coal industry as it would allow efficient plant operation. Multivariate analysis has been applied to near-infrared(NIR) spectra coal for investigating the relationship between coal properties(%) (moisture, ash, volatile matter, fixed carbon, carbon, hydrogen, nitrogen, oxygen, sulfur), heating value(kcal/kg) and corresponding near-infrared spectral data. The quantitative analysis was carried out by applying PLS(partial least squares regression) to determine a methodology able to establish a relationship between coal properties and NIR spectral data being applied mathematical pre-treatments for minimizing the physical features of the samples. As a results of the analysis, this technique is able to classify the species of coals and to predict the all coal properties except ash, nitrogen and sulfur. The efficient operation of coal fired power plant is expected owing to real time on-line coal analysis of moisture and heating value.

Study of Feasibility Test: FT-NIR Spectrometer for Discrimination Analysis of Agrochemical Products (농약 제품의 동일성 판별을 위한 FT-NIR 분석 사례 연구)

  • Jin, Jung-Hwa;Baek, Oh-Hyen;Shin, Jae-Yeon;Ha, Huen-Young;Choi, Dal-Soon;Park, Sung-Eun;lhm, Yangbin;Hong, Jin-Whan
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.3
    • /
    • pp.241-247
    • /
    • 2015
  • This study has been conducted to verify the applicability of FT-NIR (Fourier Transform Near Infrared) to prove coidentity between market agrochemical products and registered prescriptions. The spectrum correlations were investigated on 83 registered samples and there market products, 23 products which had same formulation and active ingredients and 68 products which had different active ingredients. In 83 samples/products, the primary differentiated spectrum correlation values were 95.86~100%, which mean that all samples qualified over 95% threshold. In 23 products which had same active ingredients and formulations, correlation values were 29.09~99.83%. 3 products over 99.0% were proved to have same active/inert ingredients and formulations although they're from different manufacturers. The rest products except the 3 items were under 95%. In 68 products had different active ingredients, correlation values varied from 2.00% to 93.70%. Higher correlation is supposed to come from similarity of inert ingredients despite different active ingredients. They can be decided to unqualify under 95% threshold. So applicability of FT-NIR has been verified on qualitative distinction of coidentity between registered market agrochemicals.

Estimation of Nitrate Nitrogen Concentration in Liquid Fertilizer Contaminated Areas using Hyperspectral Images (초분광 영상을 이용한 액비 오염지역의 질산성질소 농도 추정)

  • Lim, Eun Sung;Kim, I Seul;Han, Soo Jeong;Lim, Tai Yang;Song, Wonkyong
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.3
    • /
    • pp.542-549
    • /
    • 2020
  • Purpose: As nitrate nitrogen produced during fermentation of liquid fertilizer is a pollution indicator of water, in this study, four research areas where liquid fertilizer was sprayed were selected, and a model was designed to estimate the concentration of nitrate nitrogen pollution. Method: Prior to shooting on site, a spectrum library was constructed by dividing the ratio of liquid fertilizer into 5 groups: 0%, 25%, 50%, 75%, and 100%. PLSR (Partial least squares regression) method was applied to hyperspectral images acquired in the study area based on the aspect of spectrum. Result: The behavior of nitrate nitrogen was confirmed by 1st and 2nd differentiation of the spectrum of the constructed liquid fertilizer. PLSR concentration estimation modeling was implemented using images from field experiments and compared with actual concentration of nitrate nitrogen. Conclusion: When comparing the PLSR concentration estimation model with the actual concentration of nitrate nitrogen, it was measured that the detection is possible in high concentration areas where the concentration of nitrate nitrogen is 70mg/kg or more.

Determination of Color Value (L, a, b) in Green Tea Using Near-Infrared Reflectance Spectroscopy (근적외 분광분석법을 이용한 녹차의 색도 분석)

  • Lee, Min-Seuk;Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.spc
    • /
    • pp.108-114
    • /
    • 2008
  • Near infrared spectroscopy (NIRS) is a rapid and accurate analytical method for determining the composition of agricultural products and feeds. The applicability of near infrared reflectance spectroscopic method was tested to determine the color value (L, a, b) of green tea. A total of 162 green tea calibration samples and 82 validation samples were used for NIRS equation development and validation, respectively. In the developed NIRS equation for analysis of the color value (L, a, b), the most accurate equation for L value was obtained at 2, 8, 6, 1 (2nd derivative, 8 nm gap, 6 points smoothing, and 1pointsecond smoothing), and for a, and b value were obtained at 1, 4, 4, 1 (1st derivative, 4 nm gap, 4points smoothing, and 1 point second smoothing) math treatment condition with SNVD (Standard Normal Variate and Detrend) scatter correction method and entire spectrum ($400{\sim}2,500\;nm$) by using MPLS (Modified Partial Least Squares) regression. Validation results of these NIRS equations showed very low bias (L: 0.005%, a: 0.003%, b: -0.013%) and standard error of prediction (SEP, L: 0.361%, a: 0.141%, b: 0.306%) as well as high coefficient of determination ($R^2$, L: 0.905, a: 0.986, b: 0.931). Therefore, these NIRS equations can be applicable and reliable for determination of color value (L, a, b) of green tea, and NIRS method could be used as a mass screening technique for breeding programs and quality control in the green tea industry.

Observation for drying non-uniformity of allium vegetables using NIR spectroscopy (근적외 분광법을 이용한 양념 야채의 건조 불균일성 관찰)

  • Cho, Hyeong Ho;Lee, Seon Mi;Park, Sang Wook;Cho, Rae Kwang
    • Food Science and Preservation
    • /
    • v.21 no.6
    • /
    • pp.838-843
    • /
    • 2014
  • In this study, near-infrared spectroscopy was used to observe the drying non-uniformity of vegetables such as spring onions, onions, and garlic, which are commonly used for seasoning. For the warm-air convection drying method, the vegetables showed drying non-uniformity, which is due to the unevenness of the wind temperature and humidity depending on the height and position of the drying tray. The second derivative spectra between the vegetable samples with different drying degrees were compared. The peak at around 1,390~1,400 nm, which is assigned to weak hydrogen bonds of water, was changed during drying whereas the peak near 1,420 nm, which represents strong hydrogen (H-) bonds of water, was not changed, indicating that water with weak H-bonds evaporates first during drying, and that water with strong H-bonds remains after drying. The hyperspectral NIR imaging technique combined with principal-component analysis made it possible to discriminate the dried vegetables according to their drying degree.

Quantification of Tocopherol and Tocotrienol Content in Rice Bran by Near Infrated Reflectance Spectroscopy (근적외선분광분석기를 이용한 미강의 Tocopherol과 Tocotrienol 함량 분석)

  • 김용호;강창성;이영상
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.3
    • /
    • pp.211-215
    • /
    • 2004
  • Near infrared reflectance spectroscopy (NIRS) is a rapid and accurate analytical method for determining the composition of agricultural products and feeds. This study was conducted to determine tocopherol and tocotrienol contents in rice bran by using NIRS system. Total 80 rice bran samples previously analyzed by HPLC were scanned by NIRS and over 60 samples were selected for calibration and validation equation. A calibration equation calculated by MPLS(modified partial least squares) regression technique was developed and coefficient of determination for tocopheyol and tocotyienol content were 0.975 and 0.984, respectively, in calibration sets. Each calibration equation was fitted to validation set that was performed with the remaining samples not included is the calibration set, which showed high positive correlation both in tocopherol and tocotrienol content file. This results demonstrate that the developed NIRS equation can be practically used as a rapid screening method for quantification of tocopherol and tocotrienol contents in rice bran.

Prediction of Internal Quality for Cherry Tomato using Hyperspectral Reflectance Imagery (초분광 반사광 영상을 이용한 방울토마토 내부품질 인자 예측)

  • Kim, Dae-Yong;Cho, Byoung-Kwan;Kim, Young-Sik
    • Food Engineering Progress
    • /
    • v.15 no.4
    • /
    • pp.324-331
    • /
    • 2011
  • Hyperspectral reflectance imaging technology was used to predict internal quality of cherry tomatoes with the spectral range of 400-1000 nm. Partial least square (PLS) regression method was used to predict firmness, sugar content, and acid content. The PLS models were developed with several preprocessing methods, such as normalization, standard normal variate (SNV), multiplicative scatter correction (MSC), and derivative of Savitzky Golay. The performance of the prediction models were investigated to find the best combination of the preprocessing and PLS models. The coefficients of determination ($R^{2}_{p}$) and standard errors of prediction (SEP) for the prediction of firmness, sugar content, and acid content of cherry tomatoes from green to red ripening stages were 0.876 and 1.875kgf with mean of normalization, 0.823 and $0.388^{\circ}Bx$ with maximum of normalization, and 0.620 and 0.208% with maximum of normalization, respectively.

Development of Prediction Model for Capsaicinoids Content in Red-Pepper Powder Using Near-Infrared Spectroscopy - Particle Size Effect (근적외선 스펙트럼을 이용한 고춧가루의 캡사이신 함량 예측 모델 개발 - 입자의 영향)

  • Mo, Changyeun;Kang, Sukwon;Lee, Kangjin;Lim, Jong-Guk;Cho, Byoung-Kwan;Lee, Hyun-Dong
    • Food Engineering Progress
    • /
    • v.15 no.1
    • /
    • pp.48-55
    • /
    • 2011
  • In this research, the near-infrared absorption from 1,100-2,300 nm was used to measure the content of capsaicinoids in the red-pepper powder by using the Acousto-optic tunable filters (AOTF) spectrometer with sample plate and sample rotating unit. Non-spicy red-pepper samples from one location (Younggwang-gun. Korea) were mixed with spicy one (var. Chungyang) to make samples separated by particle size (below 0.425 mm, 0.425-0.71 mm, and 0.71- 1.4 mm). The Partial Least Squares Regression (PLSR) model to predict the capsaicinoid content on particle sizes was developed with measured spectra by AOTF spectrometer and used to analyze the amount of capsaicinoids by HPLC. The PLSR Model of red-pepper powder of below 0.425 mm, 0.425-0.71 mm, and 0.71-1.4 mm with cross validation had ${R_V}^2$ = 0.948-0.979 and Standard Error of Prediction (SEP) = 6.56-7.94 mg%. The prediction error of smaller particle size of red-pepper powder was low. The best PLSR model was found in pretreatment of Range Normalization, Standard Normal Variate, and 1st Derivatives of red-pepper powder of below 1.4 mm with cross validation, having ${R_V}^2$ = 0.959 and SEP = 8.82 mg%.

The study of nondestructive method for measuring the acidity of the recent record paper in Hanji by using FT-NIR spectroscopy and Integrating sphere (푸리에 변환 근적외선 분광분석기(FT-NIR)와 적분구를 이용한 근대 한지 기록물의 산성도 비파괴 평가방법에 대한 연구)

  • Shin, Yong-Min;Park, Soung-Be;Kim, Chan-Bong;Lee, Seong-Uk;Cho, Won-Bo;Kim, Hyo-Jin
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.10a
    • /
    • pp.255-269
    • /
    • 2011
  • The purpose of study has to analyze with non destructive method for researching the tool that could be measured with the status of record written on Hanji speedily. Because the original record should be destructed for analyzing with previous method in the case of the paper record, it was to develop the tool based on non destructive method for overcoming such limit. The study was used with FT NIR (Fourier transform NIR) for analyzing the Hanji for being written and preserved. The FT NIR spectrometer that of NIR spectrometer has the better performance of precision and accuracy than dispersive NIR spectrometer was used. Also the wavelength of FT-NIR was measured with 12,500 to 4,000 $cm^{-1}$, and the integrating sphere as diffuse reflectance type was used for analyzing Hanji. The moisture and acidity (pH) of chemical factors as quality evaluated factor of Hanji was studied for the correlation of NIR spectrum. And then The NIR spectrum was pretreated for showing the coefficients of optimum correlation. MSC and First derivative of Savitzky - Golay was used as pretreated method, and the coefficients of optimum correlation were shown by PLSR(Partial least square regression). And the coefficients of optimum correlation were calculated by PLSR(Partial least square regression). The correlation coefficients of acidity had 0.92 on NIR spectra without pretreatment. Also the SEP of acidity was 0.24. And then The NIR spectra with pretreatment would have more good correlation coefficients ($R^2=0.98$) and more good SEP(=019) on acidity. Therefore the data of correlation coefficients ($R^2$) and SEP with pretreatment was shown to be superior. And NIR spectra data of first derivative had best linearity on the correlation coefficients ($R^2=0.99$) and also SEP(=0.45) was superior. Therefore the correlation coefficients and SEP of first derivative had better than those of NIR spectra of no pretreatment. As such result, it was possible to evaluate the record status of Hanji speedily with integrated sphere and NIR analyzer as non destructive method.

  • PDF