• Title/Summary/Keyword: 2진 영상

Search Result 631, Processing Time 0.035 seconds

Contrast-Enhanced Magnetic Resonance Angiography for Evaluation of the Steno-occlusive Disease of the Supraaortic Arteries: Comparison with Computed Tomography Angiography and Digital Subtraction Angiography (조영증강 자기공명 혈관조영술을 이용한 대동맥궁 위 혈관의 협착 및 페쇄 질환 평가: 전산화 단층 혈관조영술 및 디지털 감산혈관조영술과의 비교)

  • Jeh, Su-Kyung;Kim, Bum-Soo;Jung, So-Lyung;Ahn, Kook-Jin;Shin, Yong-Sam;Lee, Kwan-Sung;Kim, Young-In;Lee, Kwang-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.152-160
    • /
    • 2009
  • Purpose : To intra-individually compare diagnostic accuracy of high-resolution contrast-enhanced magnetic resonance angiography (CE-MRA) with computed tomography angiography (CTA) and digital subtraction angiography (DSA) for the assessment of supraaortic steno-occlusive disease. Materials and Methods : Twenty-eight patients (20 men, 8 women, 53-79 years of age) underwent supraaortic CE-MRA, CTA and DSA. CE-MRA was performed on two 1.5T MR scanners (voxel dimension: $0.66{\times}0.66{\times}1.1$ or $1.2\;mm^3$), and CTA on 64-slice CT scanners (voxel dimension: $0.42{\times}0.42{\times}0.63\;mm^3$). All the three examinations were completed within 40 days (median 19 days; range 1-40 days). Retrospective evaluation and measurement of diameter of 6 extracranial and 9 intracranial arterial segments was done by 2 experienced radiologists. Results: A total of 420 arterial segments were examined by CE-MRA, CTA and DSA. On DSA, 34 stenoocclusive lesions were noted at extracranial (n= 19) and intracranial (n = 15) vessels. For extracranial stenosis greater than 70%, sensitivity, specificity, positive predictive value (PPV) and negative predictive values (NPV) were 94.7%, 98.7%, 90.0% and 99.3% on CE-MRA, and 94.7%, 99.3%, 94.7% and 99.3% on CTA. For intracranial stenosis greater than 50%, sensitivity; specificity, PPV and NPV were 93.3%, 98.3%, 77.8%and 99.6% on CE-MRA, and 86.7%, 97.9%, 72.2% and 99.1 % on CTA, with DSA as the standard of reference. Conclusion : Supraaortic CE-MRA is as reliable as CTA in depicting the arterial stenosis, and is effective in screening of significant stenosis of both extracranial and intracranial arterial stenosis.

  • PDF

Neuroimaging Findings of First-Visit Headache Patients (두통 초진 환자에서 신경영상검사 소견)

  • Kim, Byung-Su;Kim, Soo-Kyoung;Kim, Jae-Moon;Moon, Heui-Soo;Park, Kwang-Yeol;Park, Jeong Wook;Sohn, Jong-Hee;Song, Tae-Jin;Chu, Min Kyung;Cha, Myoung-Jin;Kim, Byung-Kun;Cho, Soo-Jin
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.294-301
    • /
    • 2018
  • Background: Neuroimaging can play a crucial role in discovering potential abnormalities to cause secondary headache. There has been a progress in the fields of headache diagnosis and neuroimaging in the past two decades. We sought to investigate neuroimaging findings according to headache disorders, age, sex, and imaging modalities in first-visit headache patients. Methods: We used data of consecutive first-visit headache patients from 9 university and 2 general referral hospitals. The International Classification of Headache Disorders, third edition, beta version was used in headache diagnosis. We finally enrolled 1,080 patients undertook neuroimaging in this study. Results: Among 1,080 patients (mean age: $47.7{\pm}14.3$, female: 60.8%), proportions of headache diagnosis were as follows: primary headaches, n=926 (85.7%); secondary headaches, n=110 (10.2%); and cranial neuropathies and other headaches, n=43 (4.1%). Of them, 591 patients (54.7%) received magnetic resonance imaging (MRI). Neuroimaging abnormalities were found in 232 patients (21.5%), and their proportions were higher in older age groups and male sex. Chronic cerebral ischemia was the most common finding (n=88, 8.1%), whereas 76 patients (7.0%) were found to have clinically significant abnormalities such as primary brain tumor, cancer metastasis, and headache-relevant cerebrovascular disease. Patients underwent MRI were four times more likely to have neuroimaging abnormalities than those underwent computed tomography (33.3% vs. 7.2%, p<0.001). Conclusions: In this study, the findings of neuroimaging differed according to headache disorders, age, sex, and imaging modalities. MRI can be a preferable neuroimaging modality to identify potential causes of headache.

Sensitivity Analysis for CAS500-4 Atmospheric Correction Using Simulated Images and Suggestion of the Use of Geostationary Satellite-based Atmospheric Parameters (모의영상을 이용한 농림위성 대기보정의 주요 파라미터 민감도 분석 및 타위성 산출물 활용 가능성 제시)

  • Kang, Yoojin;Cho, Dongjin;Han, Daehyeon;Im, Jungho;Lim, Joongbin;Oh, Kum-hui;Kwon, Eonhye
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_1
    • /
    • pp.1029-1042
    • /
    • 2021
  • As part of the next-generation Compact Advanced Satellite 500 (CAS500) project, CAS500-4 is scheduled to be launched in 2025 focusing on the remote sensing of agriculture and forestry. To obtain quantitative information on vegetation from satellite images, it is necessary to acquire surface reflectance through atmospheric correction. Thus, it is essential to develop an atmospheric correction method suitable for CAS500-4. Since the absorption and scattering characteristics in the atmosphere vary depending on the wavelength, it is needed to analyze the sensitivity of atmospheric correction parameters such as aerosol optical depth (AOD) and water vapor (WV) considering the wavelengths of CAS500-4. In addition, as CAS500-4 has only five channels (blue, green, red, red edge, and near-infrared), making it difficult to directly calculate key parameters for atmospheric correction, external parameter data should be used. Therefore, thisstudy performed a sensitivity analysis of the key parameters (AOD, WV, and O3) using the simulated images based on Sentinel-2 satellite data, which has similar wavelength specifications to CAS500-4, and examined the possibility of using the products of GEO-KOMPSAT-2A (GK2A) as atmospheric parameters. The sensitivity analysisshowed that AOD wasthe most important parameter with greater sensitivity in visible channels than in the near-infrared region. In particular, since AOD change of 20% causes about a 100% error rate in the blue channel surface reflectance in forests, a highly reliable AOD is needed to obtain accurate surface reflectance. The atmospherically corrected surface reflectance based on the GK2A AOD and WV was compared with the Sentinel-2 L2A reflectance data through the separability index of the known land cover pixels. The result showed that two corrected surface reflectance had similar Seperability index (SI) values, the atmospheric corrected surface reflectance based on the GK2A AOD showed higher SI than the Sentinel-2 L2A reflectance data in short-wavelength channels. Thus, it is judged that the parameters provided by GK2A can be fully utilized for atmospheric correction of the CAS500-4. The research findings will provide a basis for atmospheric correction of the CAS500-4 in the future.

Elevation of Plasma NT-proBNP Concentration in a Korean Jindo Dog Infected with Dirofilaria immitis (심장사상충 감염 진도견에서 혈장 NT-proBNP 농도 증가 증례)

  • Hwang, Soo-Hyen;Park, Hyung-Jin;Seo, Kyoung-Won;Lee, Sang-Eun;Song, Kun-Ho
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.496-498
    • /
    • 2013
  • The aim of this study is to report the observed elevation of plasma N-terminal pro-B-type natriuretic peptide (NT proBNP) concentration in a Korean Jindo Dog infected with Dirofilaria immitis. Evaluation of the animal included physical examination, thoracic radiography, ELISA kit ($PetCheck^{(R)}$, IDEXX Laboratories, USA) test and plasma NT-proBNP evaluation. The infected animal's NT-proBNP concentration was compared with those of 5 normal dogs of the same age, sex, and breed; the affected Korean Jindo dog had increased plasma NT-proBNP. To the best our knowledge, this is the first report of NT-proBNP elevation in a Korean Jindo dog with dirofilariasis.

IRRADIATION EFFECT ON SECRETING FUNCTION, AMYLASE ACTIVITY AND NUCLEIC ACID CONTENTS OF RAT PAROTID GLAND (방사선 조사가 이하선 기능에 미치는 영향에 관한 연구)

  • Cho Yong Jin;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.53-62
    • /
    • 1990
  • This experiment was performed to clarify the effects of /sup 60/Co gamma irradiation on secretory function, amylase activity and contents of nucleic acids of parotid gland in rat. Experimental animals were divided into 6th hours, 3rd, 7th, 14th and 28th days after irradiation and control. The experimental animals are singly irradiated with 20Gy (2,000rad) through protective lead block. Secretory function of parotid gland was evaluted by uptake and clearance of /sup 99m/TcO₄. /sup 99m/TcO₄. 0.2μ ci/gm, was injected into peritonium in uptake groups. Rats were sacrified with cervical dislocation after 30 minutes and gland was excised. In the clearance group. pilocarpine nitrate (8㎎/㎏) was intraperitoneally injected at 30 minutes after /sup 99m/TcO₄ injection and rats were sacrified 30 minutes after pilocarpine injection. Radioactivity of excised parotid gland was measured by using of gamma counter and stimulation-secretion coefficients, uptake radioactivity divided by clearance radioactivity, was calculated. Amylase activity and contents of DNA and RNA were determined by spectrophotometry. The results obtained were as follows: 1. In the uptake test, the radioactivity of /sup 99m/TcO₄ per unit weight increase in experimental group except 6th hours group, compared with control groups and showed a peak at 3rd days after irradiation. 2. In the clearance test, the radioactivity of /sup 99m/cO₄per unit weight rose to a peak at 3rd days after irradiation and gradually recovered thereafter. 3. Stimulation-secretion coefficient of parotid gland decreased at 6th hours, 3rd and 7th days after irradiation, and gradually increased. 4. Amylase activity of parotid gland decreased in 3rd and 7th days group, and especially lowest in 3rd days after irradiation. 5. The contents of DNA showed no definite difference in all the experimental groups, but RNA was seemed to decrease with time after irradiation.

  • PDF

Study on the extraction of ocean wind, wave and current using SAR (SAR를 이용한 해풍, 파랑, 해류 추출 기법 연구)

  • Kang, Moon-Kyung;Park, Yong-Wook;Lee, Moon-Jin;Lee, Hoon-Yol
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.187-194
    • /
    • 2006
  • Recently satellite SAR techniques have become essential observation tools for various ocean phenomena such as wind, wave, and current. The CMOD4 and CMOD-IFR2 models are used to calculate the magnitude of wind at SAR resolution with no directional information. Combination of the wave-SAR spectrum analysis and the inter-look cross-spectra techniques provides amplitude and direction of the ocean wave over a square-km sized imagette, The Doppler shift measurement of SAR image yields surface speed of the ocean current along the rador looking direction, again at imagette resolution. In this paper we report the development of a SAR Ocean processor (SOP) incorporating all of these techniques. We have applied the SOP to several RADARSAT-1 images of the coast of Korean peninsula and compared the results with oceanographic data, which showed reliability of spaceborne SAR-based oceanographic research.

  • PDF

Study on the Extraction of Ocean Wind, Wave and Current using SAR (SAR를 이용한 해풍, 파랑, 해류 추출 기법 연구)

  • Kang, Moon-Kyung;Park, Yong-Wook;Lee, Moon-Jin;Lee, Hoon-Yol
    • Journal of Navigation and Port Research
    • /
    • v.31 no.1 s.117
    • /
    • pp.35-42
    • /
    • 2007
  • Recently satellite SAR techniques have become essential observation tools for various ocean phenomena such as wind, wave, and current. The CMOD4 and CMOD-IFR2 models are used to calculate the magnitude of wind at SAR resolution with no directional information. Combination of the wave-SAR spectrum analysis and the inter-look cross-spectra techniques provides amplitude and direction of the ocean wave over a square-km sized imagette, The Doppler shift measurement of SAR image yields surface speed of the ocean current along the radar looking direction, again at imagette resolution. In this paper we report the development of a SAR Ocean processor(SOP) incorporating all of these techniques. We have applied the SOP to several RADARSAT-1 images of the coast of Korean peninsula and compared the results with oceanographic data, which showed reliability of spaceborne SAR-based oceanographic research.

Fast Intra Mode Selection Algorithm for H.264/AVC Using Constraints of Frequency Characteristics (주파수 특성의 제약 조건들을 이용한 H.264/AVC를 위한 고속 화면 내 모드 선택 방법)

  • Jin, Soon-Jong;Park, Sang-Jun;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.4C
    • /
    • pp.321-329
    • /
    • 2008
  • H.264/AVC video coding standard enables a considerably higher improvement in coding efficiency compared with previous standards such as MPEG-2, H.263 and MPEG-4. To achieve this, for each macro-block in H.264/AVC, Rate-Distortion Optimization (RDO) technique is employed to select the best motion vector, reference frame, and macro-block mode. As a result, computational complexity is increased significantly whereas RDO achieve higher improvement. This paper presents fast intra mode selection algorithm based on constraints of frequency characteristics which are derived from intra coding modes of H.264/AVC. First of all, we observe the features of each intra mode through the frequency analysis of image. And then proposed Frequency Error Costs (FECs) are calculated to select the best mode which has minimum cost. Computational complexity is considerably reduced because rate-distortion costs only calculate the candidate modes which are set of best mode and its neighbouring two modes. Experimental results show that proposed algorithm reduces the complexity dramatically maintaining the rate-distortion performance compared with H.264/AVC reference software.

Geometry Padding for Segmented Sphere Projection (SSP) in 360 Video (360 비디오의 SSP를 위한 기하학적 패딩)

  • Kim, Hyun-Ho;Myeong, Sang-Jin;Yoon, Yong-Uk;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.24 no.1
    • /
    • pp.25-31
    • /
    • 2019
  • 360 video is attracting attention as immersive media, and is also considered in VVC (Versatile Video Coding), which is being developed in JVET (Joint Video Expert Team) as a new video coding standard of post-HEVC. A 2D image projected from 360 video for its compression may has discontinuities between the projected faces and inactive regions, and they may cause the visual artifacts in the reconstructed video as well as decrease of coding efficiency. In this paper, we propose a method of efficient geometric padding to reduce these discontinuities and inactive regions in the projection format of SSP (Segmented Sphere Projection). Experimental results show that the proposed method improves subjective quality compared to the existing padding of SSP that uses copy padding with minor loss of coding gain.

Radioiodine Therapy of Liver Cancer Cell Following Tissue Specific Sodium Iodide Symporter Gene Transfer and Assessment of Therapeutic Efficacy with Optical Imaging (조직 특이 발현 Sodium Iodide Symporter 유전자 이입에 의한 방사성옥소 간암세포 치료와 광학영상을 이용한 치료효과 평가)

  • Jang, Byoung-Kuk;Lee, You-La;Lee, Yong-Jin;Ahn, Sohn-Joo;Ryu, Min-Jung;Yoon, Sun-Mi;Lee, Sang-Woo;Yoo, Jeong-Soo;Cho, Je-Yeol;Lee, Jae-Tae;Ahn, Byeong-Cheol
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.383-393
    • /
    • 2008
  • Purpose: Cancer specific killing can be achieved by therapeutic gene activated by cancer specific promotor. Expression of sodium iodide symporter (NIS) gene causes transportation and concentration of iodide into the cell, therefore radioiodine treatment after NIS gene transfer to cancer cell could be a form of radionuclide gene therapy. luciferase (Luc) gene transfected cancer cell can be monitored by in vivo optical imaging after D-luciferin injection. Aims of the study are to make vector with both therapeutic NIS gene driven by AFP promoter and reporter Luc gene driven by CMV promoter, to perform hepatocellular carcinoma specific radiodiodine gene therapy by the vector, and assessment of the therapy effect by optical imaging using luciferase expression. Materials and Methods: A Vector with AFP promoter driven NIS gene and CMV promoter driven Luc gene (AFP-NIS-CMV-Luc) was constructed. Liver cancer cell (HepG2, Huh-7) and non liver cancer cell (HCT-15) were transfected with the vector using liposome. Expression of the NIS gene at mRNA level was elucidated by RT-PCR. Radioiodide uptake, perchlorate blockade, and washout tests were performed and bioluminescence also measured by luminometer in these cells. In vitro clonogenic assay with 1-131 was performed. In vivo nuclear imaging was obtained with gamma camera after 1-131 intraperitoneal injection. Results: A Vector with AFP-NIS-CMV-Luc was constructed and successfully transfected into HepG2, Huh-7 and HCT-15 cells. HepG2 and Huh-7 cells with AFP-NIS-CMV-Luc gene showed higher iodide uptake than non transfected cells and the higher iodide uptake was totally blocked by addition of perchlorate. HCT-15 cell did not showed any change of iodide uptake by the gene transfection. Transfected cells had higher light output than control cells. In vitro clonogenic assay, transfected HepG2 and Huh-7 cells showed lower colony count than non transfected HepG2 and Huh-7 cells, but transfected HCT-15 cell did not showed any difference than non transfected HCT-15 cell. Number of Huh-7 cells with AFP-NIS-CMV-Luc gene transfection was positively correlated with radioidine accumulation and luciferase activity. In vivo nuclear imaging with 1-131 was successful in AFP-NIS-CMV-Luc gene transfected Huh-7 cell xenograft on nude mouse. Conclusion: A Vector with AFP promoter driven NIS and CMV promoter driven Luc gene was constructed. Transfection of the vector showed liver cancer cell specific enhancement of 1-131 cytotoxicity by AFP promoter, and the effect of the radioiodine therapy can be successfully assessed by non-invasive luminescence measurement.