• Title/Summary/Keyword: 2중 파장법

Search Result 127, Processing Time 0.034 seconds

Predicting Calcium and Phosphorus Concentrations in Imported Hay by near Infrared Reflectance Spectroscopy (근적외선분광법을 이용한 수입건초의 Ca과 P 함량 예측)

  • Lee, Bae Hun;Kim, Ji Hye;Oh, Mirae;Lee, Ki Won;Park, Hyung Soo
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.41 no.1
    • /
    • pp.29-34
    • /
    • 2021
  • Near infrared reflectance spectroscopy (NIRS) is routinely used for the determination of nutrient components of forages. However, little is known about the impact of sample preparation and wavelength on the accuracy of the calibration to predict minerals. This study was conducted to assess the effect of sample preparation and wavelength of near infrared spectrum for the improvement of calibration and prediction accuracy of Calcium (Ca) and Phosphorus (P) in imported hay using NIRS. The samples were scanned in reflectance in a monochromator instrument (680-2,500 nm). Calibration models (n = 126) were developed using partial least squares regression (PLS) based on cross-validation. The optimum calibrations were selected based on the highest coefficients of determination in cross validation (R2) and the lowest standard error of cross-validation (SECV). The highest R2 and the lowest SECV were obtained using oven-dry grinded sample preparation and 1,100-2,500 nm wavelength. The calibration (R2) and SECV were 0.99 (SECV: 468.6) for Ca and 0.91 (SECV: 224.7) for P in mg/kg DM on a dry weight, respectively. Results of this experiment showed the possibility of NIRS method to predict mineral (Ca and P) concentration of imported hay in Korea for routine analysis method to evaluate the feed value.

Determination of carbaryl in aqueous solution by fluorescence spectrometry (형광분광법을 이용한 수용액 중의 carbaryl의 정량)

  • Kim, Wook Hyun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.307-312
    • /
    • 2009
  • A spectrofluorimetric methods has been developed for the determination of carbaryl in an aqueous solution. The effects of excitation wavelength, concentration of surfactant, concentration of ethanol as cosurfactant and emission wavelength on the fluorescence intensity were investigated to find the optimum experimental conditions to determine carbaryl. The emission intensity of the carbayl was increased with addition of sodium dodecyl sulfate (SDS) as a surfactant. The emission intensity of the carbaryl was further increased with addition of ethanol as a co-surfactant. The optimum conditions were 281 nm for excitation wavelength, $1.0{\times}10^{-2}mol/L$ SDS, 20% (v/v) ethanol and 349 nm for emission wavelength. Under the optimum conditions, the emission intensity increased with the carbaryl concentration in the range of $5{\times}10^{-7}$ to $1.0{\times}10^{-4}mol/L$ with a detection limit ($3{\sigma}$) of $1.1{\times}10^{-8}mol/L$. The resulting correlation coefficient of the working curve was 0.9996.

Treatment of the dyestuff solution using photocatalyst membrane system (분리막ㆍ광촉매 시스템을 이용한 염료 수용액의 처리)

  • 곽민욱;민병렬;탁태문;정건용
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05b
    • /
    • pp.184-187
    • /
    • 2004
  • 고급산화법 중 하나인 광촉매인 TiO$_2$를 이용한 시스템은 300~400nm 파장의 UV영역에서 비교적 적은 에너지로 유기 오염 물질을 $CO_2$$H_2O$로 산화시킨다[1]. 따라서 폐수용액 중 오염물질을 제거한 경우에도 슬러리로 인한 2차 오염의 문제가 없다. 최근에는 난분해성 물질이나 독성을 가진 물질을 포함된 폐수처리 시설의 고도처리를 위하여 분리막을 도입하는 추세이다.(중략)

  • PDF

Rapid Evaluation of Chemical Components of Rice Grain Using Near Infrared Spectroscopy (근적외분광분석법에 의한 미질관련 성분 측정)

  • 황흥구;조래광;손재근;이수관
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.39 no.1
    • /
    • pp.7-14
    • /
    • 1994
  • This study was conducted to establish the rapid evaluation method of chemical components of rice grain on the basis of non-destructive method. A near-infrared reflectance spectroscopic(NIRS) method was utilized, for the determination of amylose, protein, magnesium, and potassium content of rice. A multiple linear regression analysis for the data obtained by standard laboratory methods and NIRS method was carried out to make a calibration. The standard error of prediction for amylose, protein, magneisum and potassium content were 0.88%, 0.28%, 12.62mg and 10.79mg, respectively. It was concluded that the NlRS method can be useful the rapid determination of amylose, protein, magnesium and potassium content instead of the existing laboratory method.

  • PDF

Optical Gain of AIGaN/GaN DH at Room-Temperature (실온에서 AIGaN/GaN DH의 광학이득)

  • ;;H. Amano;I. Akasaki
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1994.11a
    • /
    • pp.97-97
    • /
    • 1994
  • Wide gap 반도체 중 하나인 GaN 에너지갭이 실온에서 3.4eV 이고 직접천이형 에너지대 구조를 가지므로 청색 및 자외영역의 파장을 발광하는 발광다이오드와 바도체 레이저 다이오드의 제작에유용한 재료이다. GaN계 III족 질화물반도체가 다파장용 광원으로서 유망함을 보인 것은 1970년대 초방의기초적 연구이다. 이로부터 약 25년이 경고한 현재 청색발광다이오드가 실용화당계에 이르게 되었지만 아직까지 전류주입에 의한 레이저발진은 보고되고있지 않다. 이 논문에서는 ALGaN/GaN이중이종접합(DH) 구조의 광여기에 의한 유도방출과 광학적 이득을 측정하므로서 전류주입에의한 레이저발진의 가능성을 조사하였다. 유기금속기상에피텍셜(MOVPE)법으로 성장한 ALGaN/GaN DH구조의 표면에 수직으로 펄스발진 질소레이저(파장:337.1nm, 주기:10Hz, 폭: 8nsec) 빔의 공출력밀도를 변화시키어 조사하고 시료의단면 혹은 표면으로부터 방출되는 광 스펙트럼을 측정하였다. 입상광밀도가 증가함에 따라 자연방출에 의한 발광피크보다 낮은 에너지에서 발광강도가 큰 유도방출에 의한 피크가 370nm의 파장에서 현저하게 나타났으며 실온에서 유동방출에 필요한 입사공밀도의 임계치는 약 89㎾/$\textrm{cm}^2$이었다. 이는 GaN 단독층에 대한 유동방출의 임계치 700㎾/$\textrm{cm}^2$ 에 비하여 약 1/8정도 낮은 것이며, 이를 전류밀도로 환산하면 약 27㎄/$\textrm{cm}^2$ 정도로서 전류주입에 의하여서도 레이저발진을 실현할 수 있는 현실적인 값이다. 한편 광여기 방법으로 측정한 광학적 이득은 입사광의 밀도가 각각 100㎾/$\textrm{cm}^2$과 200㎾/$\textrm{cm}^2$일 때 34$cm^{-1}$ / 과 160 $cm^{-1}$ / 이었다. 이와 같은 결과는 GaN의밴드단 부근의 파장영역에서 AIGaN 흔정의 굴절율이 GaN의 굴절율보다 작으므로 DH구조의 채택의 의한 광의 몰입이 가능하여 임계치가 저하된 것으로 여겨진다. 또한 광학적 이득의 존재는 이 구조에 의한 극단파장 반도체 레이저다이오드의 실현 가능성을 나타내는 것이다.

  • PDF

Studies on the Development of Photoreceptor in the Nonchromatophore Organisms (V) - Effects of FAD and $FADH_2$ on Light-Induced Mitochondrial ATPase and ATP Synthase in Lentinus edodes - (무흡광색소 생물의 감광수용체 개발연구(V) - 표고버섯 중의 광감응성 Mitochondrial ATPase 및 ATP synthase에 대한 FAD 및 $FADH_2$의 효과 -)

  • Park, Sang-Shin;Min, Tae-Jin
    • The Korean Journal of Mycology
    • /
    • v.17 no.3
    • /
    • pp.161-168
    • /
    • 1989
  • Mitochondria in L. edodes were separated and purified by stepped sucrose density gradient centrifugation. In our previous work, we have found that the activation wavelengths of the mitochondrial ATPase and ATP synthase were 680 nm and 470 nm within the range of 400-700 nm, respectively. The activities of the above enzymes with wavelengths of 300-400 nm region were investigated. The mitochondrial ATPase and ATP synthase were stimulated at 380 nm and 330 nm, respectively, for 30 min illumination compared with dark control group. They, however, were inhibited at 330 nm and 350 nm, respectively. The presence of FAD resulted in inhibition of the activity of the ATPase and stimulation of the activity of the ATP synthase by the activation and inhibition wavelengths. However, the activities of these enzymes were not changed by NADH for the above wavelengths. In the spectral properties, the oxidation of $FADH_2$ into FAD occurs in the presence of the enzymes for illumination of the activation and inhibition wavelengths. Therefore, we can predict that the mitochondrial ATPase and ATP synthase may function as oxidant in the redox reaction by the light illumination and that the light-induced pigment of the mitochondrial ATP synthase should be an oxidized form of a flavoprotein.

  • PDF

A Study on the Calibration of Shape Measurement System Using Digital moire (Digital moire 형상측정 시스템의 보정에 관한 연구)

  • 김도훈;유원재;박낙규;강영준
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.255-259
    • /
    • 2003
  • Moire topography method isa well-known non-contacting 3-D measurement method as afast non-contact test for three-dimension shape measuring method. Recently, it's important to study the automatic three-dimension measurement by moire topography because it is frequently applied to the reverse engineering , the medical , the entertainment fields. Three-dimension measurement using projection of moire topography is very attractive because of its high measuring speed and high sensitivity. In this paper, the classical moire method is computerized-so called digital moire when a virtual grating pattern is projected on a surface, the captured image by the CCD camera has three-dimension information of the objects. The moire image can be obtained through a simple image processing and a reference grating pattern. and it provides similar results without physical grating pattern. digital projection moire topography turn out to be very effective for the three-dimension measurement of objects. Using different N-bucket algorithm method of digital projection moire topography is tested to measuring object with the 2-ambiguity problem. Experimental results prove that the proposed scheme is capable of finding measurement errors that decreased more by using the four-three step algorithm method instead of the same step in the phase shifting of different pitch.

  • PDF

Photo-Acoustic Signal Detection of Water using FIR Light Source (원적외선 광원을 이용한 Water에서의 Photo Acoustic Signal의 검출)

  • 김건식;김태우;전계진;윤길원;최중길;박승한
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.252-253
    • /
    • 2002
  • 원적외선 영역에서 혈중성분들의 분광 특성이 존재함이 확인되면서 이 영역의 빛을 이용한 혈중 성분의 정량 분석을 통한 진단기술 개발이 활발히 진행되고 있다1). 특히 원적외선 영역에서 특정 파장에서의 반응성을 이용한 여러 방법들 중 photo-Acoustic을 이용한 방법이 여러 가지로 연구되어지고 있다. (2) 현재 수용액 상태의 혈중 성분들의 원적외선 분광 특성을 연구하였으며, 이를 이용한 혼합 성분들의 흡수 spectrum 정량-정성 분석이 가능하며, 이러한 특성을 이용하여 non-invasive로 이용 가능한 분광법을 연구 진행 중이다. (중략)

  • PDF

Determination of terbutaline in human plasma by coupled column chromatography (커플드칼럼크로마토그래피에 의한 사람 혈장 중 테르부탈린의 정량)

  • Ko, Mi Young;Jeon, Sang-Seol;Kim, Kyeong Ho
    • Analytical Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.125-131
    • /
    • 2015
  • A method was developed and fully validated for the determination of terbutaline, a β2-receptor agonist, in human plasma. Plasma samples were prepared by solid-phase extraction with Sep-Pak silica, followed by high-performance liquid chromatography (HPLC). The terbutaline was pre-separated from the interfering components in plasma on a Luna C18 (2) column, and terbutaline and salbutamol as an internal standard were resolved and determined on a Luna Silica column. The two columns were connected by a switching valve equipped with silica pre-column. The pre-column was used to concentrate the terbutaline in the eluent from the C18 column before back-flushing onto the silica column with fluorescence detection at an excitation/emission wavelength of 276/306 nm. The method was shown to be specific by testing six different human plasma sources. Linearity was established for a concentration range of 0.4-20.0 ng/mL with a correlation coefficient of 0.9999. The lower limit of quantitation was 0.4 ng/mL with a precision of 10.1% as C.V.%.

Determination and confirmation of the carbendazim residue in soybean sprout (콩나물중 살균제 carbendazim 잔류분의 정량 및 확인)

  • Kim, Young-Gook;Park, Jong-Tae;Hong, Suk-Soon
    • The Korean Journal of Pesticide Science
    • /
    • v.2 no.3
    • /
    • pp.79-84
    • /
    • 1998
  • Tandem HPLC and atmospheric pressure chemical ionization(APcI) LC/MS method was used for the determination and confirmation of carbendazim residues in soybean sprout. Fluorescence(FL) detector was connected in tandem with the ultraviolet(UV) detector for dual detection of the carbendazim residue at the excitation and emission wavelength of 280 nm and 310 nm, respectively. The limit of detection for carbendazim was $0.1{\mu}g/kg$ sample. Recoveries of carbendazim from fortified soybean sprout at 0.5, 1.0 and 2.0 ppm were averaged 89.1%. Mass spectrometry using a APcI source confirmed the carbendazim residue in the soybean sprout sample. Fragmentation pattern on the APcI LC/MS spectrum of carbendazim was simpler than that from electron impact(EI) mass spectrum. Carbendazim produced 3 major ions including m/z 133, m/z 159 and m/z 191($M^{+}$). This method was sensitive enough to provide reliable and reproducible results for practical applications.

  • PDF