• Title/Summary/Keyword: 2원 사이클

Search Result 77, Processing Time 0.025 seconds

An Experimental Study on the Performance of a Sea Water Heat Source Cascade Heat Pump (해수열원 캐스케이드 열펌프시스템의 운전 특성에 관한 실험적 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Chang, Ki-Chang;Park, Seong-Ryong;Ra, Ho-Sang;Lee, Jea-Hun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1969-1973
    • /
    • 2007
  • The purpose of this study is to investigate the performance of a sea water heat source cascade heat pump system. R717(Ammonia) is used for a low-stage working fluid while R134a is for a high-stage. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. In this study, two experiments were carried out. One is a system starting test from the low load temperature of $10^{\circ}C$. The other is a system performance investigation over the R717 compressor capacity changes. Experimental results show that when it starts from the low load temperature, the suction temperature of the low-stage compressor is higher than that of a high-stage. The system performance increases when a water source temperature or a low-stage compressor rotational frequency goes higher.

  • PDF

The Cooling Performance Enhancement of a Variable Speed Heat Pump Using Gas Injection Technique (가스인젝션 기술을 적용한 공기열원 가변속 열펌프의 냉방성능 향상에 관한 연구)

  • Jeong, Min-Woo;Heo, Jae-Hhyeok;Jung, Hae-Won;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.425-432
    • /
    • 2009
  • In this study, the improvement of cooling capacity by applying gas injection technique in a two-stage heat pump using R410A was experimentally investigated. A twin rotary type compressor with gas injection was applied to the heat pump system. The optimum refrigerant charge for the injection and the non-injection cycles was selected to achieve the maximum COP at the cooling standard condition. The injection cycle showed less optimum refrigerant charge than that of the non-injection cycle. The cooling performances of the injection and the non-injection cycles were measured and compared by varying compressor frequency from 40 to 90 Hz. The cooling capacity of the gas injection cycle was 1.6% -11.3% higher than that of the non-injection cycle. The COP of the gas injection cycle was 13.7% to 28.9% higher than that of the non-injection cycle at the same cooling capacity. The heat pump system showed stable operation after 30% of the injection valve opening.

Battery Equalization Circuit using Charge Control Scheme (전하 제어법을 이용한 배터리 균등화 회로)

  • Chun, Chang-Yoon;Shin, Jong-Won;Kim, Jong-Hoon;Cho, Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.422-423
    • /
    • 2010
  • 직렬 연결된 배터리는 각 셀의 내부 화학적 특성 차이로 인해 동일 전류로 충전 및 방전 과정을 진행하여도 셀 간에 미세한 전압 차이가 발생한다. 이러한 셀 간 전압 불균형은 배터리 셀에 해로운 영향을 끼치게 되는데, 2차 전지의 경우 배터리 용량의 변화를 야기한다. 이러한 문제를 해결하기 위해서 배터리 운용 범위를 제한하는 보호회로가 있지만 보호회로는 직렬 연결된 배터리 셀 중 가장 전압이 높거나 가장 낮은 셀을 기준으로 충전과 방전 사이클을 종료시키므로 배터리 팩의 용량을 최대한으로 사용하지 못하게 하는 문제를 발생시킨다. 배터리 균등화 회로는 셀 간의 전압 차이를 줄여 배터리의 최대 용량을 사용하고자 하는 목적을 가진다. 저항을 기반으로 하는 수동적인 방법과는 달리 스위칭 소자를 이용하는 능동적인 방법에서는 스위칭으로 인해 입출력 전압 변동이 발생하여 컨버터 내부에 흐르는 전류가 수시로 변하는 문제가 생긴다. 위 문제를 해결하기 위한 방법으로 본 논문에서는 배터리 균등화 회로에 전하 제어(Charge control)기법을 제안하고, 그에 따른 회로 설계 요소를 제시한다.

  • PDF

A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer (가속도 센서를 이용한 실시간 스포츠 동작 분류.모니터링에 관한 연구)

  • Kang, Dong-Won;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.59-64
    • /
    • 2008
  • D. W. KANG, J. S. CHOI, and G. R. TACK, A Study on Real-Time Sports Activity Classification & Monitoring Using a Tri-axial Accelerometer. Korean Jouranl of Sport Biomechanics, Vol. 18, No. 2, pp. 59-64, 2008. This study was conducted to study the real-time sports activity classification and monitoring using single waist mounted tri-axial accelerometer. This monitoring system detects events of sports activities such as walking, running, cycling, transitions between movements, resting and emergency event of falls. Accelerometer module was developed small and easily attachable on waist using wireless communication system which does not constrain sports activities. The sensor signal was transferred to PC and each movement pattern was classified using the developed algorithm in real-time environment. To evaluate proposed algorithm, experiment was performed with several sports activities such as walking, running, cycling movement for 100sec each and falls, transition movements(sit to stand, lie to stand, stand to sit, lie to sit, stand to lie and sit to lie) for 20 times each with 5 healthy subjects. The results showed that successful detection rate of the system for all activities was 95.4%. In this study, through sports activity monitoring. it was possible to classify accurate sports activities and to notify emergency event such as falls. For further study, the accurate energy consumption algorithm for each sports activity is under development.

Influence of Precooling Cooling Air on the Performance of a Gas Turbine Combined Cycle (냉각공기의 예냉각이 가스터빈 복합발전 성능에 미치는 영향)

  • Kwon, Ik-Hwan;Kang, Do-Won;Kang, Soo-Young;Kim, Tong-Seop
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.2
    • /
    • pp.171-179
    • /
    • 2012
  • Cooling of hot sections, especially the turbine nozzle and rotor blades, has a significant impact on gas turbine performance. In this study, the influence of precooling of the cooling air on the performance of gas turbines and their combined cycle plants was investigated. A state-of-the-art F-class gas turbine was selected, and its design performance was deliberately simulated using detailed component models including turbine blade cooling. Off-design analysis was used to simulate changes in the operating conditions and performance of the gas turbines due to precooling of the cooling air. Thermodynamic and aerodynamic models were used to simulate the performance of the cooled nozzle and rotor blade. In the combined cycle plant, the heat rejected from the cooling air was recovered at the bottoming steam cycle to optimize the overall plant performance. With a 200K decrease of all cooling air stream, an almost 1.78% power upgrade due to increase in main gas flow and a 0.70 percent point efficiency decrease due to the fuel flow increase to maintain design turbine inlet temperature were predicted.

Numerical Simulation of a Two-Stage Hybrid Heat Pump (2단 압축 하이브리드 히트펌프의 특성 시뮬레이션)

  • Jeong, Si-Young;Yun, Han-Gu;Park, Ki-Woong;Park, Seong-Ryong;Kim, Min-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • Hybrid heat pumps, which combine the vapor compression and absorption heat pump cycle, can efficiently produce hot water of $80^{\circ}-90^{\circ}C$ from the low temperature of ${\sim}50^{\circ}C$. In this study, the performance of a two-stage hybrid heat pump (HHP) was compared with a single-stage hybrid heat pump using EES (Engineering Equation Solver). For the same operating conditions, the two-stage HHP showed a slightly higher COP (Coefficient Of Performance) and more stable operating conditions than the single-stage HHP. Moreover, the maximum working fluid temperature of the two-stage HHP was found to be lower than that of the single-stage HHP by about 40 K, which makes the working conditions of the lubricating oil safer. The COPs of both systems decreased with increasing UA-values. However, the heat output of the HHP was increased at the same time.

핵융합로용 플라즈마 대향부품 개발을 위해 제작된 텅스텐/FM강 HIP 접합 목업의 수명 평가 해석

  • Lee, Dong-Won;Sin, Gyu-In;Kim, Seok-Gwon;Jin, Hyeong-Gon;Lee, Eo-Hwak;Yun, Jae-Seong;Mun, Se-Yeon;Hong, Bong-Geun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.452-452
    • /
    • 2014
  • 블랑켓 일차벽이나 디버터와 같은 핵융합로 플라즈마 대향부품은 플라즈마로부터 입사되는 중성자 및 입자들을 차폐하여 구조물을 보호하고, 발생열을 에너지로 변환하기 위해 냉각재를 활용한 열제거 기능을 담당한다. 특히, 고속중성자와 입사 열부하 및 여러 입자들로부터 블랑켓 및 내부 구조물을 보호하기 위해 차폐체와 구조물로 구성된다. 세계적으로 차폐체로서는 텅스텐 혹은 텅스텐 합금, 구조물용 재료로는 저방사화 Ferritic Martensitic (FM) 강이 유력한 후보재료로 개발, 연구 중에 있다. 국내에서는 국제핵융합로(ITER) 사업을 통해 고온등방가압(HIP, Hot Isostatic Pressing)을 이용한 이종금속간 접합기술과 한국형 저방사화 고온구조재료인 ARAA (Advanced Reduced Activation Alloy)가 개발되고 있으며, 이를 활용한 설계, 접합법 개발, 제작목업의 건전성 평가 등이 수행되고 있다. 한국원자력연구원에서는 핵융합 기초사업의 일환으로 전북대와 공동으로 수행 중인 건전성 평가체계 개발을 위해, 기 개발된 접합법을 활용한 $45mm(H){\times}45mm(W){\times}2mm(T)$의 W/FM강 목업을 제작한 바 있으며, 이를 국내 구축된 고열부하 시험 장비인 KoHLT-EB (Electron Beam)를 활용한 고열부하 인가 건전성 평가시험을 준비 중에 있다. 이종금속간 접합 특성은 기계적 평가를 위한 파괴시험을 통해 검증, 이를 활용한 목업이 제작되었으며, 제작된 목업에 대한 초음파를 이용한 접합면의 비파괴 검사를 통해 결함이 없음을 확인하였다. 최종적으로 실제 사용되는 핵융합 운전조건과 유사 혹은 가혹한 조건에서 고열부하를 인가하여, 그 건전성을 평가가 이루어질 것이다. 고열부하 시험을 위해서는 냉각조건, 인가 열부하, 수명평가를 통한 반복 고열부하 인가 횟수 등이 사전에 결정되어야 한다. 이를 위해 상업용 열수력, 구조해석 코드인 ANSYS-CFX와 -mechanical을 이용한 시험조건 모의 및 수명 평가가 수행되었다. 구축 장비의 냉각계통을 고려하여 냉각수의 온도 및 속도는 $25^{\circ}C$, 0.15 kg/sec로, 열부하는 0.5 및 $1.0MW/m^2$에 대해 모의를 수행하였다. 정상상태 시 텅스텐의 최대 온도는 각 열부하 조건에 따라 $285.3^{\circ}C$$546.8^{\circ}C$였으며, 이에 도달하는 시간을 구하기 위해 천이해석을 수행하였고, 이를 통해 30초에 최대온도 95 %이상의 정상상태 온도에 도달함을 확인하였다. 또한, 목업의 초기 온도에 도달하는 냉각시간도 동일한 천이해석을 통해 30초로 가능함을 확인하였고, 최종 시험 조건을 30초 가열, 30초 냉각으로 결정하였다. 결정된 반복 열부하 인가 조건에서 이종금속 접합체가 받는 다른 열팽창 정도에 따른 응력을 계산하여 목업의 수명을 도출하였고, 이를 시험해야 할 반복 횟수로 결정하였다. 각 열부하 조건에 따른 온도조건을 ANSYS-mechanical 코드를 활용하여 열팽창과 이에 따른 접합면의 응력분포로 계산하였다. 0.5 및 $1.0MW/m^2$에 대해, 목업이 받는 최대 응력은 334.3 MPa와 588.0 MPa 였으며, 이 때 텅스텐과 FM강이 받는 strain을 도출하여 물성치로 알려진 cycle to failure 값을 도출하였다. 열부하에서 예상되는 수명은 0.5 및 $1.0MW/m^2$에 대해, 100,000 사이클 이상과 2,655 사이클로 계산되었으며, 시간적 제약을 고려 최종 평가는 $1.0MW/m^2$에 대해, 3,000사이클 정도의 실험을 통해 그 수명까지 접합건전성이 유지되는 지 실험을 통해 평가할 예정이다.

  • PDF

Research of Effective Method for Pellet Using Jubak (주박을 활용한 펠릿화의 효율적인 방법 연구)

  • Kim, Dae-Nyeon;Lee, Jung-Bok;Kim, Deok-Hyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.247-247
    • /
    • 2010
  • 본 연구는 주류 제조과정에서 발생하는 생전분발효 부산물을 펠릿(pellet)연료로 전환하는 과정에서 효율적인 방법에 대해 기술한다. 술을 정제하는 과정에서 발생하는 주박을 펠릿화하고 재생청정에너지인 폐자원의 효율성을 높이기 위한 방법을 제안한다. 술을 정제하고 남은 지게미를 주박(酒粕, 술지게미)이라 하고 흔히 부드러운 것을 단단하게 뭉친 알갱이를 펠릿이라 한다. 현재 펠릿화는 폐목재를 분쇄후 성형, 가공하여 목재펠릿을 만들어 상용화하고 있다. 목재펠릿은 성형, 가공하는데 비용이 주박보다 많이 들고 열량도 더 낮음을 확인하였다. 목재소에서 나온 나무(톱밥)와 주박을 열량측정기를 이용하여 측정한 결과로 나무는 약 1850 Kcal이고 주박은 약 1989 Kcal가 측정되었다. 나무는 일반 목재소 세 곳에서 채취한 것이고 주박은 막걸리, 약주 및 청주의 술지게미를 실험에 사용한다. 주류업체에서도 술을 정제하고 남은 주박을 처리하는데 많은 곤란과 비용이 든다. 또한 주박을 해양에 투척하여 처리해 왔으나 2012년부터 해양투기가 금지되어 더욱 처리에 곤란을 겪게 된다. 최근 주박을 토양개량제(비료)로 개발하여 사용하기도 하나 본 연구에서 제안하는 장점은 농산물을 재배해서 주류제조시 발생되는 주박을 펠릿화하여 연료로 사용하고 남은 재를 토양개량제로 사용하는 장점이 있다. 제품의 전체 라이프 사이클을 통해 환경으로 방출되는 모든 것을 가능한 한 0(zero)으로 하는 활동인 제로-이미션(zero-emision)이 된다. 이는 단순히 배출량만을 줄이는 것이 아니라 폐기물을 유용한 자원으로 활용한다는 측면이 가장 큰 이점이 된다. 주박의 효율성을 높이기 위해 주박을 종류별로 주박과 목재를 섞는 방법으로 열량을 측정하였다. 먼저 열량이 높은 순서로 막걸리 주박과 약주 주박의 비율을 1:1, 1:0.5, 1:0.2, 두 번째 막걸리 주박과 청주 주박의 비율을 1:1, 1:0.5, 1:0.2, 세 번째 막걸리 주박과 나무 톱밥의 비율을 1:1, 1:0.5, 1:0.2로 섞어서 열량을 측정하였다. 열량이 높은 순서는 세 번째(2015Kcal), 두 번째(1995Kcal), 첫 번째(1868Kcal)의 순이었다. 가장 열량이 높은 막걸리 주박과 나무 톱밥을 섞은 것이 가장 효율성이 높다. 주박 펠릿의 장점은 친환경적인 소재이고 지속적으로 재생이 가능한 에너지원이다. 더욱이 주박 펠릿은 발열량이 높고 다른 바이오매스 원료에 비해 청정하다는 큰 장점을 지니고 있다. 또한 사용에 소요되는 유지 관리비용을 최소화할 수 있고 자동화가 가능하여 사용에 편리하다. 가격면에서 화석연료에 비해 안정적이고 체적 또한 작아 이송의 큰 장점을 가지고 있다. 현재 펠릿의 경우는 목재펠릿이 제품화되어 있지만 주박을 이용하여 제품의 펠릿화를 통한 연료원으로 사용하는 경우는 전 세계 전무한 상태로 폐자원을 재사용하는 효율성이 제시된다. 향후 과제로 주박을 이용한 펠릿 연료원의 기술이 개발되고 기계적인 시스템을 개발하면 저탄소 녹색성장 신재생에너지 연료의 획기적인 미래형 에너지시스템이 될 것이다.

  • PDF

Relationship between Lower -Limb Joint Angle and Muscle Activity due to Saddle Height during Cycle Pedaling (사이클 페달링 시 안장높이에 따른 하지관절 각도와 근육활성화의 상관관계)

  • Seo, Jeong-Woo;Choi, Jin-Seung;Kang, Dong-Won;Bae, Jae-Hyuk;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study was to investigate the effects of different saddle heights on lower-limb joint angle and muscle activity. Six elite cyclists(age: $32.2{\pm}5.2years$, height: $171.0{\pm}3.5cm$, weight: $79.7{\pm}5.6kg$, cycle career: $13{\pm}6.2years$) participated in three min. submaximal(90 rpm) pedaling tests with the same load and cadence based on saddle heights where subject's saddle height was determined by his knee flexion angle when the pedal crank was at the 6 o'clock position. Joint angles(hip, knee, ankle joints) and the activity of lower limb muscles(biceps femoris(BF), vastus lateralis(VL), tibialis anterior(TA) and gastrocnemius medial(GM)) were compared by measuring 3D motion and electromyography(EMG) data. Results showed that there were significant differences in minimum hip & knee joint angle and range of motion of hip and knee joint between saddle heights. Onset timing and integrated EMG of only BF among 4 muscles were significantly different between saddle heights. Especially there was a negative relationship between minimum hip joint angle and onset timing of BF in most subject, which means that onset timing of BF became fast as the degree of bending of the hip joint became larger by saddle height. Optimal pedaling will be possible through increased amount of muscle activation due to the appropriate burst onset timing by proper pedaling posture with adjusted saddle height.

Conceptual Study of an Exhaust Nozzle of an Afterburning Turbofan Engine (후기연소기 장착 터보팬엔진의 배기노즐 개념연구)

  • Choi, Seongman;Myong, Rhoshin;Kim, Woncheol
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.3
    • /
    • pp.62-69
    • /
    • 2014
  • This paper presents a preliminary study of a convergent divergent nozzle in an afterburning turbofan engine of a supersonic aircraft engine. In order to design a convergent divergent nozzle, cycle model of a low bypass afterburning turbofan engine of which thrust class is 29,000 lbf at a sea level static condition is established. The cycle analysis at the design point is conducted by Gasturb 12 software and one dimensional gas properties at a downstream direction of the turbine are obtained. The dimension and configuration of an model turbofan engine are derived from take-off operation with wet reheat condition. The off-design cycle calculation is conducted at the all flight envelope on the maximum flight Mach number of 2.0 and maximum flight altitude of 15,000 m.