• 제목/요약/키워드: 2단 망간모래여과

검색결과 2건 처리시간 0.016초

2단 망간모래여과에 의한 고농도 망간 처리 (Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration)

  • 김충환;윤종섭;임재림;김성수
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.

철 및 망간코팅사를 분리 충진시킨 파일럿 여과시스템에 의한 3가 비소 제거 (Removal of As(III) by Pilot-Scale Filtration System Separately Packed with Iron-Coated Sand and Manganese-Coated Sand)

  • 김광섭;송기훈;양재규;장윤영
    • 대한환경공학회지
    • /
    • 제28권8호
    • /
    • pp.878-883
    • /
    • 2006
  • 망간코팅모래(MCS)와 철코팅모래(ICS) 21.5 kg씩 동량을 하부 및 상부층으로 2단 충진시킨 파일럿 규모의 여과시스템을 구성하여 3가 비소 함유 인공오염수 처리효율을 조사하였다. 파일럿 장치는 높이 200 cm와 내경 15 cm로 구성되어 있으며, 3가 비소함유 인공 오염수의 반응기 칼럼내 유입은 peristaltic pump를 사용하여 선속도 $5{\times}10^{-3}$ cm/s로 상향류로 시켰으며 148일 동안 여과실험을 실시하였다. MCS 통과지점(중간유출수)과 ICS 통과지점(최종 유출수)에서의 총 비소의 파과는 각각 18일 및 44일 경과 후에 이루어졌고 그 이후 파과가 급격히 진행되었으며 148일이 지났을 때 완전파과가 발생하였다. 비록 MCS 층을 통과한 유출수에서의 총 비소파과는 18일 경과 후에 나타났지만 유출수내의 3가 비소 농도는 61일 동안 50 ppb 이하로 나타났으며 이후에는 급격히 증가되어 나타났다. 이것은 칼럼에 충진된 MCS가 61일 동안 효과적으로 3가 비소에 대한 산화력을 나타내기 때문에 기인한 것이며 MCS 1 kg당 3가 비소 92 mg을 산화처리 함을 나타낸다. 그리고 완전파과가 발생할 때 까지 MCS에 의해서 흡착된 총 비소의 양은 MCS 단위 kg 당 79.0 mg에 해당하였다. 운전기간 동안 반응탑내의 각 지점에서의 시간에 따른 수두의 변화는 크게 나타나지 않아서 ICS 및 MCS를 갖춘 여과시스템은 큰 수두손실 없이 오염수를 장기간 처리할 수 있음을 알 수 있었다.