• 제목/요약/키워드: 1m distance

검색결과 2,667건 처리시간 0.034초

CODES OVER $Z_m$

  • Abualrub, Taher
    • Journal of applied mathematics & informatics
    • /
    • 제5권1호
    • /
    • pp.99-110
    • /
    • 1998
  • In this paper we study cyclic codes in $Z_m$. i.e., ideals in $Z_mG$, G afinite abelian group and we give a classification of such codes. We also sgtudy the minimum Hamming distance and the generalized Hamming weight of BCH codes over $Z_m$.

가선집재작업에서의 작업 생산성 및 비용 분석 (Comparison of Harvesting Productivity and Cost of Cable Yarding Systems)

  • 한원성;한한섭;김남훈;차두송;조구현;민도홍;권기철
    • 한국산림과학회지
    • /
    • 제103권1호
    • /
    • pp.87-97
    • /
    • 2014
  • 본 연구에서는 임목수확작업에 사용되는 집재기계의 작업효율성을 분석하여 경사가 급한($20^{\circ}$ 이상) 작업조건에 적합한 가선계 집재기계를 선정하는데 기초 정보를 제공하고자, 타워야더(RME-300T), 트랙터부착형 집재기(일명 : 춘천집재기), 트랙터윈치(FARMI) 등에 의한 집재작업에서의 작업생산성 및 비용을 비교 분석하였다. 평균 흉고직경이 20 cm, 집재거리 60 m, 가로집재거리 10 m, 그리고 기계이용률이 70%인 동일한 작업 조건에서 작업이 이루어질 경우, 타워야더의 1일 집재작업 생산성은 $33.04m^3$/일, 트랙터부착형 집재기는 $38.47m^3$/일, 그리고 트랙터윈치는 $14.17m^3$/일으로 분석되었으며, 이에 따른 집재작업비용은 각각 25,105원/$m^3$, 20,520원/$m^3$, 37,835원/$m^3$으로 나타났다. 동일한 작업조건에서 집재거리에 따른 각 집재기계별 작업효율성을 비교하였을 경우, 집재거리가 40 m 이내로 짧을 경우에는 트랙터윈치에 의한 집재작업이 효율적이며, 40~140 m의 집재거리에서는 춘천집재기가, 140 m 이상의 장거리 집재작업에서는 타워야더가 가장 효율적인 것으로 나타났다.

광학렌즈 AR 코팅에 따른 폴리머애자에서의 방전 자외선 강도 비교 (Comparison of Discharge UV Intensity Due to AR Coating of Optic Lens on Polymer Insulator)

  • 김영석;송길목;방선배;김종민;최명일
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.35-40
    • /
    • 2012
  • In this study, the ultraviolet (UV) intensity of polymer insulator was measured using the Anti-Reflective (AR) coating lens on the occurrence of corona discharge. The UV intensity was compared before and after the AR coating. Under the 200-260[nm] of UV lens, the reflection rate before AR coating was 7.5~5.5[%] with 85-89[%] of transmission rate. After AR coating, however, the reflection rate decreased to 1.3~1.22[%] with improved transmission (97.4~97.6[%]). Then, the UV intensity by distance was measured in the polymer insulator. According to the measurement, the UV intensity increased 6.5 times at 37.5[%] of Vm/Vbd with 5[m] of distance. As distance increased, the growth rate declined. As high voltage increased, in addition, AR coating was less effective due to the count error caused by the UV sensor pulse signal overlap. Therefore, it appears that it would be more effective to detect corona discharge with 5[m] or less of distance at diagnosis of power facilities by AR coating and UV sensor sensitivity.

괴산지역 대야산 화강암체 주변 접촉변성대(황강리층)에서의 투휘석 결정 크기분포 (Diopside DSD (crystal size distribution) in the Contact Metamorphic Aureole (Hwanggangni Formation) near the Daeyasan Granite Goesan, Korea)

  • Kim, Sangmyung;Kim, Hyung-Shik
    • 암석학회지
    • /
    • 제5권2호
    • /
    • pp.161-167
    • /
    • 1996
  • The CSD (crystal size distribution) of diopside crystals in the calc-silicate hornfels of the Hwanggangni Formation intruded by the Cretaceous Daeyasan granite shows the patterns of continuous nucleation and growth. There is correlation between the distance from the intrusion contact and the slopes from the linear part of log(population density) vs. size diagrams. In the log(population density) vs. size diagrams of the samples systematically collected from the intrusion contact, two different groups are recognized; the slopes for the samples near the intrusion contact (horizontal distance from the contact less than 50m) are gentler (1500$cm^{-1}$) than those for the samples away from the intrusion contact (2500$cm^{-1}$, distance from the contact greater than 100 m). These differences may reflect the differences in growth rates and crystallization time, or the differences in diopside-forming reactions. All of the log(population density) vs. size diagrams show depletion of smaller crystals. The observed depletion may be due to Ostwald ripening or the changes in nucleation rates as the reactant phases diminishes. Similar grouping is also possible for the observed degree of depletion of smaller crystals; the depletion decreases with increasing distance from the intrusion contact, suggesting temperature-dependent rates of Ostwald ripening.

  • PDF

Passive Ranging Based on Planar Homography in a Monocular Vision System

  • Wu, Xin-mei;Guan, Fang-li;Xu, Ai-jun
    • Journal of Information Processing Systems
    • /
    • 제16권1호
    • /
    • pp.155-170
    • /
    • 2020
  • Passive ranging is a critical part of machine vision measurement. Most of passive ranging methods based on machine vision use binocular technology which need strict hardware conditions and lack of universality. To measure the distance of an object placed on horizontal plane, we present a passive ranging method based on monocular vision system by smartphone. Experimental results show that given the same abscissas, the ordinatesis of the image points linearly related to their actual imaging angles. According to this principle, we first establish a depth extraction model by assuming a linear function and substituting the actual imaging angles and ordinates of the special conjugate points into the linear function. The vertical distance of the target object to the optical axis is then calculated according to imaging principle of camera, and the passive ranging can be derived by depth and vertical distance to the optical axis of target object. Experimental results show that ranging by this method has a higher accuracy compare with others based on binocular vision system. The mean relative error of the depth measurement is 0.937% when the distance is within 3 m. When it is 3-10 m, the mean relative error is 1.71%. Compared with other methods based on monocular vision system, the method does not need to calibrate before ranging and avoids the error caused by data fitting.

Sizes and Structures of Micelles of Cationic Octadecyl Trimethyl Ammonium Chloride and Anionic Ammonium Dodecyl Sulfate Surfactants in Aqueous Solutions

  • Kim, Hong-Un;Lim, Kyung-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권3호
    • /
    • pp.382-388
    • /
    • 2004
  • The sizes and structures of micelles formed in aqueous solutions of cationic octadecyl trimethyl ammonium chloride (OTAC) and anionic ammonium dodecyl sulfate (ADS) surfactants were investigated using smallangle neutron scattering (SANS), self-diffusion coefficients by pulsed-gradient spin-echo (PGSE) NMR, and dynamic light scattering (DLS) methods. SANS and DLS data indicate that their structures are spherical at concentrations as high as 300 mM. As the total surfactant concentration increases, the peaks of SANS spectra shift to higher scattering vector and become sharper, indicating that the intermicellar distance decreases and its distribution becomes narrower. This is due to more compact packing of surfactant molecules at high concentrations. The intermicellar distance of around 100 ${\AA}$ above 200 mM corresponds approximately to the diameter of one micelle. The sizes of spherical micelles are 61 ${\AA}$ and 41 ${\AA}$ for 9 mM OTAC and 10 mM ADS, respectively. Also the self-diffusion coefficients by PGSE-NMR yield the apparent sizes 96 ${\AA}$ and 31 ${\AA}$ for micelles of 1 mM OTAC and 10 mM ADS, respectively. For ADS solutions of high concentrations (100-300 mM), DLS data show that the micelle size remains constant at $25{\pm}2{\AA}$. This indicates that the transition in micellar shape does not take place up to 300 mM, which is consistent with the SANS results.

DEPENDENCY OF SINGLE-PHASE FAC OF CARBON AND LOW-ALLOY STEELS FOR NPP SYSTEM PIPING ON PH, ORIFICE DISTANCE AND MATERIAL

  • Moon, Jeong-Ho;Chung, Hung-Ho;Sung, Ki-Woung;Kim, Uh-Chul;Rho, Jae-Seong
    • Nuclear Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.375-384
    • /
    • 2005
  • To investigate the flow-accelerated corrosion (FAC) dependency of carbon steel (A106 Gr. B) and low-alloy steels (1Cr-1/2Mo, 21/4Cr-1Mo) on pH, orifice distance, and material, experiments were carried out. These experiments were performed using a flow velocity of 4 m/sec (partly 9 m/sec) at pH $8.0\~10.0$ in an oxygen-free aqueous solution re-circulated in an Erosion-Corrosion Test Loop at $130^{\circ}\;{\ldots}$ for 500 hours. The weight loss of the carbon steel specimens appeared to be positively dependent on the flow velocity. That of the carbon and low-alloy steel specimens also showed to be distinguishably dependent on the pH. At pH levels of $8.0\~9.5$ it decreased, but increased from 9.5 to 10.0. Utility water chemistry personnel should carefully consider this kind of pH dependency to control the water system pH to mitigate FAC of the piping system material. The weight loss of the specimens located further from the orifice in the distance range of $6.8\~27.2$ mm was shown to be greater, except for 21/4Cr-1Mo, which showed no orifice distance dependency. Low alloy steel specimens exhibited a factor of two times better resistance to FAC than that of the carbon steel. Based on this kind of FAC dependency of the carbon and low-alloy steels on the orifice distance and material, we conclude that it is necessary to alternate the composition of the secondary piping system material of NPPs, using low-alloy steels, such as 21/4Cr-1Mo, particularly when the system piping has to be replaced.

전라남도 내의 백로류 집단번식지 특성에 관한 연구 (Study on the Characteristics of Mixed heronries in Jeollanam-do)

  • 이두표;김상진;황인천;임동옥
    • 한국환경생태학회:학술대회논문집
    • /
    • 한국환경생태학회 2006년도 임시총회 및 학술논문발표회
    • /
    • pp.86-96
    • /
    • 2006
  • 본 연구는 백로류 집단번식지의 보호 및 관리에 대한 기초자료를 제공하기 위하여 2005년도 번식기에 전라남도 전역을 대상으로 번식지의 분포, 번식조류 종류 및 개체수에 대한 센서스를 실시하고 백로류 생태에 중요한 번식지 특성을 파악하였다. 센서스 결과 집단번식지는 총 17개소, 번식종류는 6종이 확인되었으며 왜가리와 중대백로가 가장 많은 지역(각각 92%)에서, 가장 많은 수(36.3%, 31.0%)가 번식하는 것으로 나타났다. 번식지 식생은 대나무 군락이 53.3%로 가장 많았다. 번식지 면적은 평균 $2,346m^2(500{\sim}7,000m^2$), 가까운 두 번식지간 거리는 평균 18.1km($5.6{\sim}40.4km$), 번식지와 마을간 거리는 평균 297m($10{\sim}2000m$), 번식지 경사도는 평균 $18^{\circ}(2^{\circ}{\sim}40^{\circ})$ 이었으며 번식지 사면방향은 동쪽이 40.0%로 가장 많았다.

  • PDF

CHAID분석을 이용한 서울시 지하철 역세권 지가 영향모형 개발 (Development of Selection Model of Subway Station Influence Area (SIA) in Seoul City using Chi-square Automatic Interaction Detection (CHAID))

  • 최유란;김태호;박정수
    • 한국철도학회논문집
    • /
    • 제11권5호
    • /
    • pp.504-512
    • /
    • 2008
  • 본 연구는 합리적인 역세권 범위를 설정하고 이에 미치는 요인을 규명하기 위해 CHAID분석을 이용하여 서울시의 강남 강북지역에 대해 SIA모형을 개발하였으며, 그 결과를 요약하면 다음과 같다. 첫째, 지하철 역세권에 영향을 미치는 변수를 중심으로 상관관계를 분석한 결과, 역세권 지가에 영향을 미치는 주요요인이 도보거리로 나타났으며, 두 관계를 이용하여 SIA모형을 개발하였다. 둘째, SIA모형식(선형식, 2차 다항식)을 비교분석한 결과, 강남 북의 역세권의 범위는 지하철역사로부터 도보거리기준으로 강남지역이 767m, 강북지역이 452m로 각각 다르게 나타났다. 셋째, 강남지역의 구간 1(0$\leq$175m)의 경우 역으로부터 거리와 가격과의 관계가 선형이 아닌 2차 다항식의 형태를 나타내고 있다 따라서 현행 도시철도법상 역세권 범위 반경 500m의 기준을 획일적으로 적용하기 보다는 도시의 지역적 특성을 고려하여 재설정하는 것이 바람직하다고 판단된다.

헬멧형 뇌자도 장치로의 활용을 위한 Pb 초전도 차폐의 특성 (Characteristics of Superconductive Pb shield for a Whole Head MEG System)

  • 유권규;김기웅;이용호
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.30-35
    • /
    • 2009
  • We have investigated the characteristics of a superconductive Pb shield for hemispherical shape and plate to improving signal-to-noise ratio(SNR) of biomagnetism. We measured the shielding factor for the position of helmet shape Pb and for changing the distance from Pb surface. To make a uniform magnetic field, a $1.5m{\times}1.5m$ set of the helmholtz coils activated at several frequencies. The shielding factor of hemispherical shape Pb was from 20 to 57 dB and of Pb plate was about $6{\sim}26dB$ as a function of distance from the lead surface. The shielding factor was rapidly reduced as increasing the distance from Pb surface. The white noise of superconductive quantum interference device(SQUID) with a superconductive shield was about $12fT/Hz^{1/2}$ at 1 Hz, $7fT/Hz^{1/2}$ at 100 Hz. The white noise was more increased about two times than conventional SQUID system without Pb shielding. An auditory signal was measured by first order gradiometer and magnetometer with Pb superconductive shield and compared the SNR. The SQUID system with Pb shield had better performance at low frequency noise level.

  • PDF