• Title/Summary/Keyword: 1kW급

Search Result 383, Processing Time 0.026 seconds

Design of the Hydro-Mechanical Transmission for a 55kW-Class Agricultural Tractor (55kW급 농업용 트랙터 정유압 기계식 변속기 설계)

  • Baek, Seung Min;Kim, Wan Soo;Kim, Yeon Soo;Baek, Seung Yun;Kim, Yong Joo
    • Journal of Drive and Control
    • /
    • v.17 no.2
    • /
    • pp.19-27
    • /
    • 2020
  • The purpose of this study was to suggest design criteria for the HMT (hydro-mechanical transmission) of a 55 kW-class agricultural tractor, develop a simulation model, and evaluate its performance such as axle rotational speed, tractor speed, and power transmission efficiency. In this study, the HMT comprised a compound planetary gear and a HSU (hydro-static unit), and the compound planetary gear comprised two planetary gear sets. The HMT has three gear stages, and the maximum tractor speed was selected as 40 km/h. The simulation time was set at 2736 hours considering the lifetime of the tractor, and the simulation was performed for each gear stage at the engine-rated power conditions. As a result of the simulation, the axle rotational speeds for each gear stage were 39, 77, and 158 rpm, respectively. The range of tractor speed for each gear stage were 1.05-10.22 km/h, 10.74-20.17 km/h, and 20.70-41.40 km/h, respectively. The APE (absolute percentage gear) for the tractor's maximum speed between target value and simulation results were 2.20%, 0.85%, and 3.50%, respectively. Also, the power transmission efficiency for each gear stage were 0-75%, 72-81%, and 69-81%, respectively. The simulation results for the power transmission efficiency of the HMT were similar with the results of the previous research. This was a basic study on the development of the HMT for an agricultural tractor. In future studies, it is necessary to develop a tractor platform and evaluate the performance. The comparison between the simulation model and the HMT tractor should be performed.

A Study on Applicability to Dual-Fuel Engine of Low Caloric Gas (저발열량 가스의 혼소엔진 적용에 관한 연구)

  • Park, Cheol-Woong;Lee, Sun-Youp;Kim, Chang-Gi;Won, Sang-Yeon;Lee, Jang-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.1
    • /
    • pp.15-20
    • /
    • 2010
  • The interest on the utilization of landfill gases and biogases for energy production has been increasing due to environment concerns and global warming caused by burning fossil fuels, renewable nature of these gases. Using those synthesis gases to generate energy with engine encourages more efficient collection reducing emissions into the atmosphere and generates revenues for the operators. However the lower calorific value of synthesis gases than that of LPG or CNG affects the combustion stability and power output. Thus it becomes necessary to address disadvantages involved by studying synthesis gases in technological perspective. This paper discussed synthesis gas as a fuel for 60kW dual-fuel engine to produce power in an effective way. The methane diluted with $N_2$ was used as a fuel and developed ECU and injector driver facilitated the investigations with diesel fuel.

A Study on the Optimal Solar Power System for 10kW Wind Power in the Mokpo Seaside (목포해안지역의 10kW급 풍력과 최적의 태양광 복합발전시스템에 관한 연구)

  • Cho, Dong-Hoon;Bae, Cherl-O;Park, Young-San
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.13 no.1 s.28
    • /
    • pp.69-73
    • /
    • 2007
  • As the interest in environmental pollution increases, the use of renewable energy is uprising. Among the renewable energy resources, wind and solar energy have no environmental impact and they can be used as unlimited resources. The two power systems are mutual supplementary systems. So the two systems are usually combined for generation. We have measured several data about wind and solar. These data can be used the foundation data for the construction of wind and solar power generation plants. Also we analyzed the possible optimal solar power system for 10[kW] wind power.

  • PDF

Thermal Characteristics of 20 W LED Module on Light Thermal Conductive Plastic Heat Sink: Comparison with that on Aluminum Die Casting Alloy (ADC-12) (경량화 열전도성 플라스틱 Heat Sink기반 20 W급 LED Module의 열 특성: 다이캐스팅합금 (ADC-12)과 비교 연구)

  • Yeo, Jung-Kyu;Her, In-Sung;Lee, Seung-Min;Choi, Hee-Lack;Yu, Young-Moon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.6
    • /
    • pp.380-385
    • /
    • 2016
  • Thermal characteristics of 20 W LED module on light thermal conductive plastic (TCP) heat sink were investigated in comparison with that on aluminum die casting alloy (ADC-12). Thermal simulations of the heat sinks were conducted by using flow simulation of SolidWorks with the following input parameters: density is 1.70 and $2.82kg/m^2$, thermal conductivity is 20 and $92W/(m{\cdot}K)$ for TCP and ADC-12, respectively. The simulated and measured temperatures of the LED modules on TCP heat sink were consistent with its measured temperature, which was $3^{\circ}C$ higher that on ADC-12. The fabricated LED module on TCP heat sink with a weight of 120.5 g was 30% lighter in weight than that of the ADC-12 reference with 171.0 g.

An Analysis of Wideband and High Efficiency Class-J Power Amplifier for Multiband RRH (다중대역 RRH를 위한 Class-J 전력증폭기의 광대역과 고효율 특성분석)

  • Choi, Sang-Il;Lee, Sang-Rok;Rhee, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.3
    • /
    • pp.276-282
    • /
    • 2015
  • Until recently, power amplifiers using LDMOS were Class-AB and Doherty type, and showed 55 % efficiency for narrowband of 60 MHz bandwidth. However, owing to the RRH application of base stations power amplifier module, a bandwidth expansion of at least 100 MHz and high efficiency power amplifiers of at least 60 % power efficiency are required. In this study, a Class-J power amplifier was designed by optimizing an output matching circuit so that the second harmonic load will contain a pure reactance element only and have broadband characteristics by using GaN HEMT. The measurements showed that a 45 W Class-J power amplifier with a power added efficiency of 60~75 % was achieved when continuous wave signals were input at 1.6~2.3 GHz, including W-CDMA application.

A New Pulse Frequency Modulation(PFM) Series Boost Capacitor(SBC) Full Bridge DC/DC Converter (새로운 주파수 가변형(PFM) 직렬 부스트 캐패시터(SBC) 풀 브리지 DC/DC 컨버터)

  • Shin, Yong-Saeng;Jang, Young-Su;Roh, Chung-Wook;Hong, Sung-Soo;Lee, Hyo-Bum;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.2
    • /
    • pp.120-127
    • /
    • 2009
  • This paper proposes a new Pulse Frequency Modulation(PFM)-Series Boost Capacitor(SBC) full bridge DC/DC Converter which features a high efficiency and high power density. The proposed converter controls the output voltage by varying the voltage across the series boost capacitor according to switching frequency and has no freewheeling period due to 50% fixed duty operation. As a result, its conduction loss is lower than that of the conventional phase shift full bridge converter. Moreover, ZVS of all power switches can be ensured along wide load ranges and output current ripple is very small. Therefore, it has very desirable merits such as a small output inductor, high efficiency, and improved heat generation. This paper performs a rationale and PSIM simulation of the proposed converter. Finally, experimental results from a 1.2kW(12V, 100A) prototype are presented to confirm the operation, validity and features of the proposed converter.

High Power Density and Low Cost Photovoltaic Power Conditioning System with Energy Storage System (에너지 저장장치를 갖는 고 전력밀도 및 저가격형 태양광 인버터 시스템)

  • Keum, Moon-Hwan;Jang, Du-Hee;Hong, Sung-Soo;Han, Sang-Kyoo;SaKong, Suk-Chin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.587-593
    • /
    • 2011
  • A new high power density and low cost Photovoltaic Power Conditioning System (PV PCS) with energy storage system is proposed. Its high power density and cost effectiveness can be achieved through the unification of the maximum power point tracker and battery charger/discharger. Despite of the reduced power stage, the proposed system can achieve the same performances of maximum power point tracking and battery charging/discharging as the conventional system. Moreover, the high voltage stress across the link-capacitor can be relieved through the series-connected link-capacitor with the battery. Therefore, a large number of series/parallel-connected link-capacitors can be reduced by 4-times. Especially, when the utility power failure happens, both photovoltaic and battery energies can be supplied to the load with only one power stage. Therefore, it features a simpler structure, less mass, lower cost, and fewer devices. Finally, to confirm the operation, validity, and features of the proposed system, theoretical analysis and experimental results from a single phase AC 220Vrms/1.5kW prototype are presented.

Three-Phase ZVS DC-DC Converter with Low Transformer Turn Ratio for High Step-up and High Power Applications (낮은 변압기 턴비를 갖는 고승압.대전력용 3상 ZVS DC-DC컨버터)

  • Kim, Joon-Geun;Park, Chan-Soo;Choi, Se-Wan;Park, Ga-Woo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.242-249
    • /
    • 2011
  • The proposed converter has easy device selection for high step-up and high power applications since boost half bridge and voltage doubler cells are connected, respectively, in parallel and series in order to increase output power and voltage. Especially, optimized design of high frequency transformers is possible owing to reduced turn ratio and eliminated dc offset, and distributed power through three cores is beneficial to low profile and thermal distribution. The proposed converter does not necessitate start-up circuit and additional clamp circuit due to the use of whole duty range between 0 and 1 and is suitable for applications with wide input voltage range. Also, high efficiency can be achieved since ZVS turn on of switches are achieved in wide duty cycle range and ZCS turn on and off of diodes are achieved. The proposed converter was validated through 5 kW prototype.

Supercapacitor Energy Storage System for the Compensation of Fuel Cell Response Characteristics (연료전지 응답특성 보상용 슈퍼커패시터 에너지 저장 시스템)

  • Song, Woong-Hyub;Jung, Jae-Hun;Kim, Jin-Young;Nho, Eui-Cheol;Kim, In-Dong;Kim, Heung-Geun;Chun, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.440-447
    • /
    • 2011
  • This paper deals with supercapacitor energy storage system for the compensation of the slow response characteristics of a fuel cell generation system for grid connection. A bidirectional dc/dc converter is used for the charging and discharging of the supercapacitor. The conventional converters use additional clamping circuit, etc. to reduce a voltage spike at the instant of switching and to provide wide range of soft switching. The proposed method provides simplified hardware implementation without any clamping circuit, and soft switching condition for both charging and discharging mode with proper switching patterns. The usefulness of the proposed scheme is verified through simulation and experimental results with 1 kW system.

A Study on Steady State Characteristics of LLC Resonant Half Bridge Converter Considering Internal Losses (내부 손실이 고려된 LLC 공진형 하프브릿지 컨버터의 정상상태 특성에 관한 연구)

  • Ahn, Tae-Young
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.985-991
    • /
    • 2018
  • In this paper, an equivalent circuit reflecting the internal loss of the LLC resonant half bridge converter was proposed and a steady state characteristic equation including the loss factors was derived. Using the results, the frequency characteristics of I/O voltage gain and input impedance were compared with the lossless model In order to verify the proposed model and the derived equation, the main components of the 1kW class LLC resonant half bridge converter were selected under the same conditions and the steady state characteristics such as voltage gain and input impedance were compared. In particular, to compare more closely the steady state error of the two models, we observed the change in switching frequency with respect to the load current, which is considered to be the most important in the actual circuit design stage. As a result, it is confirmed that the error of the operating frequency is significantly improved from the proposed model and the analysis result.