가스절연개폐장치(GIS) 철공진(Ferroresonance) EMTP해석 (EMTP Analysis for Ferroresonsnce of Gas Insulated Switchgear)

  • 정영환;이동수;김정배;이학성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.366-367
    • /
    • 2008
  • This paper deal with the study of the phenomenon of Ferroresonance in the 170kV Gas Insulated Switchgear(GIS). The Electromagnetic Transient Program(EMTP) was used to simulate the phenomenon of Ferroresonance and conducted the study of the transient over-voltage. An example power system, used in this study, have an accident that the ferroresonance phenomenon happens at MOFVT(Voltage Transformer). The simulation results notices that the secondary part of VT has to be connected by ferroresonance suppressor when the circuit breaker connected with grading capacitor is switched off.

  • PDF

가스절연개폐장치의 스페이서 내장형 전자식 변압기의 설계 및 제작 (Design and Fabrication of an Electronic Voltage Transformer (EVT) Embedded in a Spacer of Gas Insulated Switchgears)

  • 임승현;김남훈;김동언;김선규;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제35권4호
    • /
    • pp.353-358
    • /
    • 2022
  • Bulky iron-core potential transformers (PT) are installed in a tank of gas insulated switchgears (GIS) for a system voltage measurement in power substations. In this paper, we studied an electronic voltage transformer (EVT) embedded in a spacer for miniaturization, eco-friendliness, and performance improvement of GIS. The prototype EVT consists of a capacitive probe (CP) that can be embedded in a spacer and a voltage Follower with a high input and a low output impedance. The CP was fabricated in the form of a Flexible-PCB to acquire the insulation performance and to withstand vibration and shock during operation. Voltage ratio of the prototype EVT is about 42,270, and the frequency bandwidth of -3 dB ranges from 0.33 Hz to 3.9 MHz. The voltage ratio error evaluated at about 6%, 12% and 18% of the rated voltage of 170 kV was 0.32%, and the phase error was 12.9 minutes. These results were within the accuracy for the class 0.5 specified in IEC 60044-7 and satisfy even in ranges from 80% to 120% of the rated voltage. If the prototype EVT replaces the conventional iron-core potential transformer, it is expected that the height of the GIS could be reduced by 11% and the amount of SF6 will be reduced by at least 10%.

입사편광에 따른 광섬유형 광 CT의 최적화 (The Optimization of Optical Current Transformer owing to Incident Polarization)

  • 김덕래;김병태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권9호
    • /
    • pp.407-413
    • /
    • 2005
  • The optical current transformer was developed for 170 kV GIS using optical fiber. The sensor optimized on the optical CT was wound 3 turns and twisted 4 times per a turn at the pipe with a diameter of 130 m. To optimize the optical CT, the output signal was measured according to the setting angle of polarizer and analyzer, The asymmetry and distortion of the output signals were improved when the parallel polarized light was incident to the fiber sensor and under the angle of analyzer was $45^{o}$. The measurement error for the linearity was only $\pm{0.42}\;\%$ to 1,000 A in the case of reflection type.

부분방전 예방진단 시스템의 로컬유닛 기능 향상을 위한 Digital Signal Processor(DSP) 응용 (The Application of Digital Signal Processor(DSP) for Improvement of Local Unit for a Partial Discharge Online Monitoring System)

  • 연만승;이재호;구자윤;강창원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1861-1863
    • /
    • 2003
  • 최근 국내 전력시장은 초고압 대전력기기 사용이 현저히 증가하고 있어 이에 따라 부분방전 예방진단 시스템의 필요성은 절대적이며 이러한 시스템의 국산화가 절실히 요구되고 있다. 예방 진단 시스템의 국산화에 있어 부분방전 신호 측정시 신호 대 잡음비(Signal to Noise ratio)를 높이기 위해 측정용 센서의 검출가능 주파수 대역을 높게 설정하여 설계되고 있는데, 따라서 센서에서 검출된 신호를 처리하기 위한 로컬유닛 또한 국산화시 외국 시스템보다 더욱 신뢰성을 가질 수 있도록 설계되어야 한다. 이를 위해서는 기존의 마이크로프로세서를 채용한 저속 시스템을 대체할 수 있도록 더욱 빠르고 높은 신뢰성의 디지털 신호처리 기술이 요구된다. 본 논문에서는 검출 센서의 아날로그 신호를 빠르게 디지털화 한 후 보다 정확한 데이터와 독립적 신호처리 그리고 네트워크를 통한 실시간 전송을 수행할 수 있는 부분방전 예방진단 시스템 로컬유닛의 프로토타입을 Digital Signal Processor (DSP)를 이용하여 구현하였다. 제작된 DSP 로컬유닛을 시험하기 위해 Real-Scale 170kV GIS Mock-up에서 부분방전 신호를 발생 시키고 센서를 통해 검출된 신호를 DSP가 처리하여 사용자의 네트워크를 통한 명령에 따른 실시간 전송모드, ${\Phi}$-q-n 진단모드로 자체 네트워크 기능을 이용하여 사용자에게 데이터를 실시간 전송하도록 하였다. 본 논문에서 구현한 DSP 로컬유닛은 대전력기기 부분방전 예방진단 시스템의 국산화에 있어 기존의 외국 시스템의 로컬유닛보다 구성이 간단하며, 실시간 신호처리 및 원거리 데이터 전송기능에서 우수한 성능을 보였다. 향후 연구에서는 다양한 분석 알고리즘을 탑재한 DSP를 개발하여 더욱 향상된 실시간 데이터 전송 및 분석기능이 우수한 DSP 로컬유닛을 개발하고자 한다.

  • PDF