• Title/Summary/Keyword: 14 MeV

Search Result 152, Processing Time 0.022 seconds

The Relative Effectiveness of Various Radiation Sources on the Resistivity Change in n-Type Silicon

  • Jung, Wun
    • Nuclear Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.91-101
    • /
    • 1969
  • Resistivity changes of n-type float-zone silicon crystals with 6.4$\times$10$^{14}$ to 1.25$\times$10$^{17}$ phosphorus atoms/㎤ due to irradiation by (1) 1 MeV electrons, (2) two types of research reactors, and (3) $Co^{60}$ ${\gamma}$-ray sources were investigated. The results were analyzed on the basis of a simple exponential formula derived by Buehler. While the formula gave a fair fit in the low fluence range in most cases, the deviation was quite appreciable in the case of 1 MeV electron irradiation, and a linear change gave better fit in some cases. The large change in the carrier removal rate in electron-irradiated samples in the high fluence range was analyzed in detail in terms of the Fermi level cross-over of the defect levels. Based on the damage constants evaluated from the initial portion of data where the formula was applicable, the relative effectiveness of various radiation sources in causing the resistivity change in n-type silicon was compared. The TRIGA Mark II reactor neutrons, for example, were found to be about 40 times more effective than 1 MeV electrons. The dependence of the damage constant on the initial carrier concentration was also examined. The physical basis of the exponential law and the effect of the Fermi level cross-over of the defect levels on the resistivity change in the high fluence ranges are discussed.

  • PDF

Dosimetric characteristics of an independent collimator system using measurements performed quarter fields. (Tungsten eyeball shield block의 임상적용에 관한 고찰)

  • Jeong, Deok-Yang;Lee, Byoung-Koo;Hwang, Woong-Koo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.89-94
    • /
    • 2002
  • During radiation therapy with electron beam to eyelid, we must keep the minimal dose on eyeball as possible. especially in the treatment of Sebaceous gland carcinoma, Squamouse cell ca., and basal cell ca. of eyelid and low grade MALToma etc. But if radiation field covered the upper & lower eyelid, it makes a cataract on lens of treated eye, in late complications. Now we reports the advantages of Tungsten eyeball shielding block compare to previously used lead block. with BOLX-I material, we made a eyeball model and measured the absorbed dose of 6MeV & 9MeV electron hem at 6 point of eyeball model with TLD chip. And compare the absorbed dose to previously lead block and other types of Tungsten eyeball shielding block.

  • PDF

The Synthesis and Crystal Structure of (${\eta}^5-Cp^*$)(Ir-B3)(1,2-S,S($CH_2SiMe_3$)-o-carborane)($C_{16}H_{35}B_{10}IrS_2Si$) ((${\eta}^5-Cp^*$)(Ir-B3)(1,2-S,S($CH_2SiMe_3$)-o-carborane) ($C_{16}H_{35}B_{10}IrS_2Si$)의 합성 및 결정구조)

  • Cho, Sung-Il
    • Korean Journal of Crystallography
    • /
    • v.18 no.1_2
    • /
    • pp.1-6
    • /
    • 2007
  • An Organometallic compound, $C_{16}H_{35}B_{10}IrS_2Si$, was synthesized from o-carborane, $Cp^*Ir(S_2C_2B{10}H_{10})$, and $Me_3SiCHN_2$. The molecular structure of this complex has been determined by X-ray diffraction. Crystallographic data : monoclinic, space group $P2_1/n$, $a=10.1986(12)\;{\AA}$, $b=14.834(5)\;{\AA}$, $c=17.139\;{\AA}$, ${\beta}=92.24(2)^{\circ}$, Z=4, $V=2591.0(14)\;{\AA}^3$. The structure was solved by direct methods and refined by full-matrix leat-squares methods to give a model with a reliability factor R=0.053 for 5080 reflections.

Synthesis and Crystal Structure of $Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$ ($Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$의 합성 및 결정 구조)

  • Cho Sung Il;Kang Sang Ook;Chang K.
    • Korean Journal of Crystallography
    • /
    • v.15 no.2
    • /
    • pp.83-87
    • /
    • 2004
  • An organometallic complex. $Me_2Pt(PPh_2CH_2C(t-Bu)=N-N=CMe(2-py)-\kappa^2N,P)$ was synthesized from phosphinohydrazone $Ph_2PCH_2C(t-Bu)=NNH_2$, 2-acetylpyridine, and $[PtMe2({\mu}-SMe_2)]_2$. The molecular structure of this complex has been determined by X-ray diffraction. Crystallographic data: monoclinic, space group $P2_1/n,\;a=11.6926(7)\;{\AA},\;b=15.6607(19)\;{\AA},\; c=14.6125(6)\;{\AA},\;\beta=93.018(4)^{\circ},\;Z=4,\;V=2672.0(4)\;{\AA}^3$. The structure was solved by direct methods and refined by full-matrix least-squares methods to give a model with a reliability factor R = 0.0363 for 5238 reflections.

Electrical Properties of Ultra-shallow$p^+-n$ Junctions using $B_{10}H_{14}$ ion Implantation ($B_{10}H_{14}$ 이온 주입을 통한 ultra-shallow $p^+-n$ junction 형성 및 전기적 특성)

  • 송재훈;김지수;임성일;전기영;최덕균;최원국
    • Journal of the Korean Vacuum Society
    • /
    • v.11 no.3
    • /
    • pp.151-158
    • /
    • 2002
  • Fabricated were ultra-shallow $p^+-n$ junctions on n-type Si(100) substrates using decaborane $(B_{10}H_{14})$ ion implantation. Decaborane ions were implanted at the acceleration voltages of 5 kV to 10 kV and at the dosages of $1\times10^{12}\textrm{cm}^2$.The implanted specimens were annealed at $800^{\circ}C$, $900^{\circ}C$ and $1000^{\circ}C$ for 10 s in $N_2$ atmosphere through a rapid thermal process. From the measurement of the implantation-induced damages through $2MeV^4 He^{2+}$ channeling spectra, the implanted specimen at the acceleration voltage of 15 kV showed higher backscattering yield than those of the bare n-type Si wafer and the implanted specimens at 5 kV and 10 kV. From the channeling spectra, the calculated thicknesses of amorphous layers induced by the ioin implantation at the acceleration voltages of 5 kV, 10 kV and 15 kV were 1.9 nm, 2.5 nm and 4.3 nm, respectively. After annealing at $800^{\circ}C$ for 10 s in $N_2$ atmosphere, most implantation-induced damages of the specimens implanted at the acceleration voltage of 10 kV were recovered and they exhibited the same channeling yield as the bare Si wafer. In this case, the calculated thickness of the amorphous layer was 0.98 nm. Hall measurements and sheet resistance measurements showed that the dopant activation increased with implantation energy, ion dosage and annealing temperature. From the current-voltage measurement, it is observed that leakage current density is decreased with the increase of annealing temperature and implantation energy.

A study on (n, α) reaction cross sections using a new empirical systematic

  • Sema Kucuksucu;Mustafa Yigit
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4026-4031
    • /
    • 2023
  • In this article, we report a new empirical formula for quick calculation of cross sections of (n, α) reactions with 14-15 MeV neutrons. Cross sections are analysed in terms of the compound nucleus model. A systematic trend for 14-15 MeV neutrons is found in the variation of (n, α) reaction cross sections with the parameters (N - Z + 1), (En + Q)0.5 and N/Z. The empirical relation between the cross sections and these parameters has been obtained, which give fairly good fits with the experimental data. We have also investigated the odd-even effects on (n, α) cross sections considering binding energy systematic of the shell model. The present formula is very useful in predicting of the (n, α) cross sections, where the measurements are not available as well as in testing new experimental data.

Evaluation of Mulberry Germplasm (Morns spp.) for Leaf Yield and Quality through Bioassay

  • Tikader, A.;Kamble, C. K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.14 no.2
    • /
    • pp.87-92
    • /
    • 2007
  • Twenty - four elite mulberry germplasm each of indigenous and exotics were studied for their leaf yield and compared with commercial check ($V_1$ and Kosen). Accession MI-0416 and ME-0169 out yielded the check accession in leaf yield/plant. The other few mulberry germplasm were also performed at par with the checks. For quality test and bioassay were conducted with the leaves of selected mulberry germplasm. Among the selected twelve mulberry accessions used for bioassay, MI-0376 and ME-033 performed better than check ($V_1$, Kosen). Other mulberry accessions i.e., MI-0310 and MI-0437 are on par with the check as far as the bioassay is concerned. MI-0376 and ME-0033 out yielded in rearing parameters and qualified for 11 and 10 rearing and related traits. Other mulberry accessions i.e., MI-0310 and MI-0437 were also qualified for eight rearing traits along with check ($V_1$). The mulberry accessions tested after selection from the preliminary characterization seems to be better and equally good in rearing and leaf yield compared to check ($V_1$, Kosen), which provides scope for selection and further evaluation. The selected mulberry accession may be included in crop improvement programme.

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

말단선량계의 광자에 대한 선량환산인자의 이론적 계산

  • 김광표;이원근;이상윤;윤석철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.883-888
    • /
    • 1995
  • 본 연구에서 말단선량계에 대한 선량평가시 선량환산인자를 산출하기 위해 1995년의 ANSI N13.32 기준인 “말단선량계의 성능평가를 위한 기준”에서 제안된 기준 팬덤을 가지고 MCNP 전산코드를 이용하여 커마근사법에 의해 수행하였다. ANSI N13.32의 기준팬텀은 손·발 그리고 손가락을 대표하는 원통형으로서 특히 손·발 팬텀에 대해서는 뼈등가물질로 알루미늄을 삽입한 것을 제안함에 따라 본 계산 목적을 위하여 팬텀설계를 똑같이 모사하였으며 사용된 광자빔 에너지는 20keV에서부터 1.5MeV에 걸쳐 14개의 단일에너지를 선택하여 수행하였다. 본 연구에서 전산수행한 결과를 ANSI N13.32의 실험적 결과와 비교해 볼 때 50keV에서부터 1.5 MeV까지의 에너지 영역에서는 최대오차 6% 이내에서 거의 일치함을 보였다.

  • PDF

Restriction of Metabolizable Energy in Broiler Growers and Its Impact on Grower and Breeder Performance

  • Sunder, G. Skyam;Kumar, Ch. Vijaya;Panda, A.K.;Raju, M.V.L.N.;Rao, S.V. Rama;Gopinath, N.C.S.;Reddy, M.R.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.8
    • /
    • pp.1258-1265
    • /
    • 2007
  • Metabolizable energy (ME) required for basal metabolism, activity and growth was considered as the criterion for targeting specific increases in body weight (100 g/week) of broiler chicks during the grower phase (5-20 weeks) and its impact was evaluated on breeder performance. Broiler female chicks (460) from a synthetic dam line were randomly distributed to 4 test groups with 23 replicates of 5 birds each and housed in cages. The first group (ME-100) was offered a calculated amount of ME by providing a measured quantity of grower diet (160 g protein and 2,600 kcal ME/kg) which increased with age and weight gain (133-294 kcal/bird/day). The other three groups were offered 10 or 20% less ME (ME-90 and ME-80, respectively) and 10% excess ME (ME-110) over the control group (ME-100). From 21 weeks of age, a single breeder diet (170 g protein and 2,600 kcal ME/kg) was uniformly fed to all groups and the impact of grower ME restriction on breeder performance evaluated up to 58 weeks. The targeted body weight gain of 1,600 g in a 16-week period was achieved by pullets of the ME-100 group almost one week earlier by gaining 8.7 g more weight per week. However, pullets in the ME-90 group gained 1,571 g during the same period, which was closer to the targeted weight. At 20 weeks of age, the conversion efficiency of feed (5.21-5.37), ME (13.9-14.1 kcal/g weight gain) and protein (0.847-0.871 g/g weight gain), eviscerated meat yield, giblet and tibia weights were not influenced by ME restriction, but the weights of abdominal fat and liver were higher with increased ME intake. Reduction of ME by 10% in the grower period significantly delayed sexual maturity (169.3 d), but increased egg production (152.5 /bird) with better persistency. Improved conversion efficiency of feed, ME and protein per g egg content were also observed in this group up to 56 weeks. The fertility and hatchability at 58 weeks of age were higher in the ME-90 group compared to the control and 10% excess ME feeding. In conclusion, the present study revealed the possibility of achieving targeted weight gain in broiler growers by feeding measured quantities of ME during the rearing period with consequential benefits in breeder performance.