• Title/Summary/Keyword: 14세기

Search Result 575, Processing Time 0.033 seconds

Study on Chinese poems written by Gusadang Kim, Nak-Haeng (구사당(九思堂) 김낙행(金樂行)의 한시(漢詩) 연구(硏究))

  • Jeong, Si-youl
    • (The)Study of the Eastern Classic
    • /
    • no.57
    • /
    • pp.407-435
    • /
    • 2014
  • Gusadang Kim, Nak-Haeng is a scholar of 18th century in Yeongnam region who wrote about 130 Chinese poems. In this study, I searched Gusadang's inner world by interpreting his Chinese poems. His life is closely related to his father Jesan Kim, Seong-Tak who was exiled. The fact that he devoted himself to his father for 10 years shows he had strong standards in making decisions in life. In short, Gusadang was a person who looked gentle but was tough inside and he remained firm in his faith even with outside pressure. He could not achieve glory because he spent time serving his father in his thirties. Although he heard compliments from others that he was talented enough to succeed as a scholar, he lacked time and mental energy to study. Also, he was a moralist and wrote some poems about impressive events in his life even though he did not fully devote himself to writing poems. In this study, I searched his inner world focusing on how he felt and thought about outside world by analyzing his poems. In conclusion, I found three characteristics from his poems. Firstly, depressed feelings are shown based on excessive self-consciousness in the poems related to his father. Secondly, his will to keep balance in life is shown because he wanted a harmonious life as a seeker after truth. Thirdly, a sense of isolation is shown because he had to keep a distance from outside world.

Indoor Positioning System using Geomagnetic Field with Recurrent Neural Network Model (순환신경망을 이용한 자기장 기반 실내측위시스템)

  • Bae, Han Jun;Choi, Lynn;Park, Byung Joon
    • The Journal of Korean Institute of Next Generation Computing
    • /
    • v.14 no.6
    • /
    • pp.57-65
    • /
    • 2018
  • Conventional RF signal-based indoor localization techniques such as BLE or Wi-Fi based fingerprinting method show considerable localization errors even in small-scale indoor environments due to unstable received signal strength(RSS) of RF signals. Therefore, it is difficult to apply the existing RF-based fingerprinting techniques to large-scale indoor environments such as airports and department stores. In this paper, instead of RF signal we use the geomagnetic sensor signal for indoor localization, whose signal strength is more stable than RF RSS. Although similar geomagnetic field values exist in indoor space, an object movement would experience a unique sequence of the geomagnetic field signals as the movement continues. We use a deep neural network model called the recurrent neural network (RNN), which is effective in recognizing time-varying sequences of sensor data, to track the user's location and movement path. To evaluate the performance of the proposed geomagnetic field based indoor positioning system (IPS), we constructed a magnetic field map for a campus testbed of about $94m{\times}26$ dimension and trained RNN using various potential movement paths and their location data extracted from the magnetic field map. By adjusting various hyperparameters, we could achieve an average localization error of 1.20 meters in the testbed.

An Epidemiologic study on the Orthodontic Patients Who Visited Department of Orthodontics, Chosun University Dental Hospital Last 10 Years(1990${\sim}$1999) (최근 10년간 조선대학교 부속치과병원 교정과에 내원한 부정교합 환자에 관한 역학적 연구(1990${\sim}$1999))

  • Yoon, Young-Jooh;Kim, Kwang-Won;Hwang, Mee-Sun
    • The korean journal of orthodontics
    • /
    • v.31 no.2 s.85
    • /
    • pp.283-300
    • /
    • 2001
  • With socioeconomic development and change of esthetic recognition, the demand for orthodontic treatment and number of orthodontic patients has been increasing so rapidly. And frequency of malocclusion was changed. So this study was done in an attempt to provide an epidemiologic study so that we can accomodate their orthodontic needs adequately and to obtain the reliable quantitative information regarding the characteristics of orthodontic patients. Distribution and trends were examined in 3,070 malocclusion patients who had been examined and diagnosed at Department of Orthodontics, Dental Hospital, Chosun University over 10 year-period from 1990 to 1999. The results were as follows : 1. The number of patients per year was increasing trend and higher visiting rate in female(56.5%) than in male(43.5%). 2. Age distribution had shown 7${\sim}$ 12 year-old group being the largest(37.9%) and each percentage of 13${\sim}$18, 19${\sim}$24, above-19, 0${\sim}$6 year${\sim}$old group was 32.0%, 19.6%, 7.1%, 3.4%. 3. Hellman dental age IVa which is completion of the permanent dentition showed the highest percentage in male and female. 4. Geographic distribution showed a majority of patients in Kwang Ju(71.0%). Group within the distance 10km from Chosun Dental Hospital was 56.3% and group within 20km was 14.7%. 5. Anterior cross bite showed the highest percentage in chief complaints and percentage of Mn. prognathism and protrusion of Mx. teeth was 12.6%, 12.2%. 6. Distribution in the types of malocclusion according to the Angle's classification had shown; 38.9% for Class I, 20.7% for Class II division 1, 2.0% for Class III division 2, 38.4% for Class III. 7. In the dental vertical dysplasia according to the Angle's classification, deep bite was the most frequent in Class II div.1 and div. 2(24.3%, 56.7%) and open bite in Class III(21.4%). 8. In the skeletal sagittal dysplasia, 39.3% of skeletal Class II was due to the undergrowth of the mandible and 46.3% of skeletal Class III was due to the overgrowth of the mandible. 9. Distribution in orthodontic treatment acceding to the extraction and nonextraction had shown 66.9% for nonextraction case, 33.1% for extraction case, and four first bicuspids have been extracted in the highest percentage(38.6%). 10. Patients who had orthognathic surgery comprised 7.9%, with an increasing trend.

  • PDF

Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators (Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가)

  • Han Youngyih;Cho Jae Ho;Park Hee Chul;Chu Sung Sil;Suh Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.24-33
    • /
    • 2002
  • Purpose : In order to improve dose homogeneity and to reduce acute toxicity in tangential whole breast radiotherapy, we evaluated two treatment techniques using multiple static fields or universal compensators. Materials and Methods : 1) Multistatic field technique : Using a three dimensional radiation treatment planning system, Adac Pinnacle 4.0, we accomplished a conventional wedged tangential plan. Examining the isodose distributions, a third field which blocked overdose regions was designed and an opposing field was created by using an automatic function of RTPS. Weighting of the beams was tuned until an ideal dose distribution was obtained. Another pair of beams were added when the dose homogeneity was not satisfactory. 2) Universal compensator technique : The breast shapes and sizes were obtained from the CT images of 20 patients who received whole breast radiation therapy at our institution. The data obtained were averaged and a pair of universal physical compensators were designed for the averaged data. DII (Dose Inhomogeneity Index : percentage volume of PTV outside $95\~105\%$ of the prescribed dose) $D_{max}$ (the maximum point dose in the PTV) and isodose distributions for each technique were compared. Results : The multistatic field technique was found to be superior to the conventional technique, reducing the mean value of DII by $14.6\%$ (p value<0.000) and the $D_{max}$ by $4.7\%$ (p value<0.000). The universal compensator was not significantly superior to the conventional technique since it decreased $D_{max}$ by $0.3\%$ (p value=0.867) and reduced DII by $3.7\%$ (p value=0.260). However, it decreased the value of DII by maximum $18\%$ when patients' breast shapes fitted in with the compensator geometry. Conclusion : The multistatic field technique is effective for improving dose homogeneity for whole breast radiation therapy and is applicable to all patients, whereas the use of universal compensators is effective only in patients whose breast shapes fit inwith the universal compensator geometry, and thus has limited applicability.

Clinical significance of codetection of the causative agents for acute respiratory tract infection in hospitalized children (급성 호흡기 감염으로 입원한 소아에서 호흡기 감염의 원인: 중복검출의 임상적 의미)

  • Roh, Eui Jung;Chang, Young Pyo;Kim, Jae Kyung;Rheem, In Soo;Park, Kwi Sung;Chung, Eun Hee
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.6
    • /
    • pp.661-666
    • /
    • 2009
  • Purpose : To determine the prevalence and clinical features of codetected respiratory etiological agents for acute respiratory infection in hospitalized children. Methods : Nasopharyngeal aspirates were obtained from hospitalized children with acute respiratory infection at Dankook University Hospital from September 2003 through June 2005. Immunofluorescent staining and culture were used for the detection of respiratory viruses (influenza virus [IFV] types A, B; parainfluenza virus [PIV] types 1, 2, 3; respiratory syncytial virus [RSV]; adenovirus [AdV]). Polymerase chain reaction (PCR) assays were used for Mycoplasma pneumoniae (MP) and Chlamydia trachomatis (CT) detection, and PCR and culture were performed for enterovirus detection. Acid-fast staining and culture were performed for tuberculosis detection. The demographic and clinical characteristics were reviewed retrospectively from the patients medical records. Results : Evidence of two or more microbes was found in 28 children: RSV was detected in 14, PIV 3 in 10, AdV in 10, MP in 8, PIV 2 in 8, CT in 4, and PIV 1 in 3. Codetected agents were found as follows: RSV+PIV 2, 6 patients; AdV+MP, 4 patients; AdV+PIV, 3 patients; RSV+MP, 3 patients; PIV 1+PIV 3, 3 patients. Distinct peaks of codetected agents were found in epidemics of MP and each respiratory virus. Conclusion : The codetected infectious agents were RSV, PIV, AdV, and MP, with distinct peaks found in epidemics of MP and each respiratory virus. Although advances in diagnostic methods have increased the prevalence of codetection, its clinical significance should be interpreted cautiously.

Radiotherapy for Nasopharyngeal Carcinoma (비인강암의 방사선치료 성적)

  • Lee, Myung-Za;Chun, Ha-Chung
    • Radiation Oncology Journal
    • /
    • v.21 no.4
    • /
    • pp.269-275
    • /
    • 2003
  • Purpose: To evaluate the results of radiation management on recurrence, survival and prognostic factors of patients with nasopharyngeal cancer Materials and Methods: Forty-nine patients, treated for nasopharyngeal cancer by radiotherapy between January 1984 and June 2000, were retrospectively studied. All patients were followed up for at least 2.5 years. Their median age was 52 years (range 17$\~$78). The histological types were 21 squamous cell carcinoma, 25 undifferentiated carcinoma, and 3 adenoid cystic carcinoma. The tumor stages were as follows: T1 in 14 patients, T2 in 24, T3 in 3, and T4 in 8, and N0 in 17 patients, Nl in 15, N2 in 4 and N3 in 13. Stages I, IIa, IIb ,III, IV and IVb were 4, 7, 12, 5, 8, and 13 patients respectively. Radiation doses of 58$\~$70 Gy (median 68.7 Gy) were given to the nasopahryngeal and involved lymphatic areas and of 46 $\~$ 50 Gy to the uninvolved neck areas. Results: The overall 5 and 10-year actuarial and disease free survival rates were 54.53$\%$ and 47$\%$ and 55.7$\%$ and 45.3$\%$, respectively The overall five-year survival rates were 100$\%$ in stage I , 80$\%$ in stage IIa, 59.5$\%$ in stage IIIb, 40$\%$ in stage III, and 42.2$\%$ in stage IV tumors. Twenty-three patients fatted either loco-regionally or distantly. Incidences of local failure, regional failure and distant metastasis for the first failure were 20.4$\%$, 8.2$\%$ and 20.4$\%$, respectively. Local recurrences were 4.3$\%$ in T1, 12.5$\%$ in T2, 0$\%$ in T3, and 62.5$\%$ in T4 lesions. Distant metastasis was seen in 41.2$\%$ of N2-3 lesions. Fifty percent of local recurrence appeared within 2 years of treatment at the primary lesion, whereas 70$\%$ of distant metastasis appeared within 2 years following treatment. Young age, female, early T stage, N0 stage; and poorly differentiated carcinoma were all related with good survival. However only stage showed statistically significance. Conclusionn: Based on the results of this study, radiation therapy to nasopharyngeal cancer showed high local recurrence in T4 and increased metastasis in N2-3 lesions. To improve local failure, further radiation doses, such as stereotactic radiation or IMRT radiation, are necessary especially in T4 lesions. The high incidence of distant metastasis in positive lymph node patients, indicates that combined radiation and effective chemotherapeutic agents with appropriated schedule are necessary.

A study on the crystallographic and magnetic Properties of Ce doped Garnet (Ce이 치환된 YIG garnet의 결정학적 및 자기적 성질 연구)

  • Kum, Jun-Sig;Kim, Sam-Jin;Shim, In-Bo;Kim, Chul-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.46-50
    • /
    • 2004
  • Compounds of $Y_{3-x}Ce_{x}Fe{5}O_{12}$(x=0.0, 0.1, 0.2, and 0.3) were prepared using the sol-gel method. The XRD measurements show that these samples have only a single phase of the garnet structure regardless of the amount of Ce substitution. The lattice constants of x = 0.0 and x = 0.3 were found to be a$_0$ = 12.3758 ${\pm}$0.0005 ${\AA}$ and 12.4062 ${\pm}$0.0005 ${\AA}$, respectively. The lattice constant increases linearly with increasing Ce concentration. The saturation magnetization was not changed flirty, with increasing Ce concentration, but coercivity decreased form 18.3 Oe to 5.8 Oe as x increased form x = 0.0 to x = 0.1. Mossbauer spectra of $Y_{3-x}Ce_{x}Fe{5}O_{12}$ were measured at various absorber temperatures from 13 K to Neel temperature. The Mossbauer spectra were fitted by least-squares technique with two subpatterns of Fe sites in the structure and corresponding to the 16a and 24d site. The temperature dependence of the magnetic hyperfine field in $^{57}$/Fe nuclei at the tetrahedral 240 and octahedral 16a sites were analyzed based on the Neel theory of ferrirnagnetism. The result of the Debye temperatures indicated that the inter-atomic binding force for the 24d site was larger than that for the 16a site.

A Definition of Korean Heat Waves and Their Spatio-temporal Patterns (우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.527-544
    • /
    • 2006
  • This study provides a definition of heat waves, which indicate the conditions of strong sultriness in summer, appropriate to Korea and intends to clarify long term(1973-2006) averaged spatial and temporal patterns of annual frequency of heat waves with respect to their intensity. Based on examination of the Korean mortality rate changes due to increase of apparent temperature under hot and humid summer conditions, three consecutive days with at least $32.5^{\circ}C,\;35.5^{\circ}C,\;38.5^{\circ}C,\;and\;41.5^{\circ}C$ of daily maximum Heat Index are defined as the Hot Spell(HS), the Heat Wave(HW), the Strong Heat Wave(SHW), and the Extreme Heat Wave(EHW), respectively. The annual frequency of all categories of heat waves is relatively low in high-elevated regions or on islands adjacent to seas. In contrast, the maximum annual frequency of heat waves during the study period as well as annual average frequency are highest in interior, low-elevated regions along major rivers in South Korea, particularly during the Changma Break period(between late July and mid-August). There is no obvious increasing or decreasing trend in the annual total frequency of all categories of heat waves for the study period However, the maximum annual frequencies of HS days at each weather station were recorded mainly in the 1970s, while most of maximum frequency records of both the HW and the SHW at individual weather stations were observed in the 1990s. It is also revealed that when heat waves occur in South Korea high humidity as well as high temperature contributes to increasing the heat wave intensity by $4.3-9.5^{\circ}C$. These results provide a useful basis to help develop a heat wave warning system appropriate to Korea.

Evaluation of Absorbed Dose and Skin Dose with MDCT Using Ionization Chamber and TLD (이온 전리함 및 TLD 법을 이용한 Multi-Detector Computed Tomography의 흡수선량 및 체표면 선량 평가)

  • Jeon, Kyung Soo;Oh, Young Kee;Baek, Jong Geun;Kim, Ok Bae;Kim, Jin Hee;Choi, Tae Jin;Jeong, Dong Hyeok;Kim, Jeong Kee
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • Recently, the uses of Multi-Detector Computed Tomography (MDCT) for radiation treatment simulation and planning which is used for intensity modulated radiation therapy with high technique are increasing. Because of the increasing uses of MDCT, additional doses are also increasing. The objective of this study is to evaluate the absorbed dose of body and skin undergoing in MDCT scans. In this study, the exposed dose at the surface and the center of the cylindrical water phantom was measured using an pencil ionization chamber, 30 cc ionization chamber and TL Powder. The results of MDCT were 31.84 mGy, 33.58 mGy and 32.73 mGy respectively. The absorbed dose at the surface showed that the TL reading value was 33.92 mGy from MDCT. These results showed that the surface dose was about 3.5% from the MDCT exposure higher than a dose which is located at the center of the phantom. These results mean that the total exposed dose undergoing MDCT 4 times (diagnostic, radiation therapy planning, follow-up et al.), is about 14 cGy, and have to be considered significantly to reduce the exposed dose from CT scan.

Gaussian Filtering Effects on Brain Tissue-masked Susceptibility Weighted Images to Optimize Voxel-based Analysis (화소 분석의 최적화를 위해 자화감수성 영상에 나타난 뇌조직의 가우시안 필터 효과 연구)

  • Hwang, Eo-Jin;Kim, Min-Ji;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.275-285
    • /
    • 2013
  • Purpose : The objective of this study was to investigate effects of different smoothing kernel sizes on brain tissue-masked susceptibility-weighted images (SWI) obtained from normal elderly subjects using voxel-based analyses. Materials and Methods: Twenty healthy human volunteers (mean $age{\pm}SD$ = $67.8{\pm}6.09$ years, 14 females and 6 males) were studied after informed consent. A fully first-order flow-compensated three-dimensional (3D) gradient-echo sequence ran to obtain axial magnitude and phase images to generate SWI data. In addition, sagittal 3D T1-weighted images were acquired with the magnetization-prepared rapid acquisition of gradient-echo sequence for brain tissue segmentation and imaging registration. Both paramagnetically (PSWI) and diamagnetically (NSWI) phase-masked SWI data were obtained with masking out non-brain tissues. Finally, both tissue-masked PSWI and NSWI data were smoothed using different smoothing kernel sizes that were isotropic 0, 2, 4, and 8 mm Gaussian kernels. The voxel-based comparisons were performed using a paired t-test between PSWI and NSWI for each smoothing kernel size. Results: The significance of comparisons increased with increasing smoothing kernel sizes. Signals from NSWI were greater than those from PSWI. The smoothing kernel size of four was optimal to use voxel-based comparisons. The bilaterally different areas were found on multiple brain regions. Conclusion: The paramagnetic (positive) phase mask led to reduce signals from high susceptibility areas. To minimize partial volume effects and contributions of large vessels, the voxel-based analysis on SWI with masked non-brain components should be utilized.