• Title/Summary/Keyword: 128-dual source CT

Search Result 3, Processing Time 0.019 seconds

Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient (64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교)

  • Kang, Yeong-Han
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • The purpose of this study was to estimate radiation doses from 64-slice single source Computed Tomography(SSCT) coronary angiography(CA) and 128-slice dual source Computed Tomography(DSCT). With SSCT CA, the effective dose averaged approximately 13.86 mSv when two dose modulation was not. The mean effective dose for DSCT CA with retrospectively gated helical(RGH) technique was 11.87 mSv, when prospective ECG gating transverse(PGT) without dose modulation technique was 5.61 mSv. The one with dose modulation in PGT technique and flash mode were 3.04 mSv and flash mode was 0.98 mSv respectively. The lifetime attributable risk(LAR) of cancer incidence from SSCT RGH mode averaged approximately 1 for 1,176, and DSCT averaged 1 for 1,960(RGH mode), 1 for 3,030(PGT without modulation), 1 for 5,882(PGT with modulation). Because of CTCA is associated with non-negligible risk of cancer. Doses can be reduced by application PGT, FLASH than RGH using DSCT.

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.

Effects of Advanced Modeled Iterative Reconstruction on Coronary Artery Calcium (CAC) Scores (ADMIRE가 관상동맥 칼슘(CAC) 점수에 미치는 영향)

  • Lee, Sang-Heon;Lee, Hyo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.603-612
    • /
    • 2021
  • The effect of Advanced Modeled Iterative Reconstruction (ADMIRE) on the coronary artery calcium (CAC) score of computed tomography was evaluated. Coronary artery calcium images (348 calcium, 6 groups, total of 2088 calcium) were acquired by 128-slice dual-source CT of 89 patients.Volume score and Agatston score were measured from images reconstructed with filtered back projection (FBP) and ADMIRE (1-5). The difference between FBP and ADMIRE Strength (1-5) was confirmed through the Kruskal-Wallis test, and the post-hoc analysis was performed using the Mann-Whitney U test based on FBP. Both volume score and Agatston score showed statistically significant differences between FBP and ADMIRE (1-5) (P=0.015, P=0.0.38). As a result of post hoc analysis, the volume score decreased to 9.5% in ADMIRE 4 (Z=-2.359, P=0.018) and 13.2% in ADMIRE 5 (Z=-3.113, P=0.002) based on FBP. Agatston score decreased to 10.4% in ADMIRE 4 (Z=-2.051, P=0.040) and 14.0% in ADMIRE 5 (Z=-2.718, P=0.007) based on FBP. High ADMIRE strength affected the volume score and Agatston score due to the decrease in calcium area. In addition, the change in the Density factor due to the decrease in Maximum HU may affect the calculation of the Agatston score.